Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Features | Base Product Number | Input Type | Approval Agency | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Current - Output (Max) | Efficiency | AC Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | DC Voltage - Input (Min) | DC Voltage - Input (Max) | Voltage - Isolation | Standard Number |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
TCL 060-124C | 97.0400 | ![]() |
1 | 0.00000000 | Traco Power | TCL (60W) | Box | Active | -10°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.94" L x 1.77" W x 2.95" H (100.1mm x 45.0mm x 74.9mm) | Adjustable Output, IP20 | TCL 060 | AC or DC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1244 | EAR99 | 8504.40.9520 | 1 | 58W | 1 | 2.5A | 88% | 85 ~ 264 VAC | 24V | - | - | - | - | - | - | 85V | 375V | 3 kV | ||
![]() |
TCL 060-112C | 121.4100 | ![]() |
10 | 0.00000000 | Traco Power | TCL (60W) | Box | Active | -10°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.94" L x 1.77" W x 2.95" H (100.1mm x 45.0mm x 74.9mm) | Adjustable Output, Universal Input | AC or DC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 1 | 48W | 1 | 4A | 88% | 85 ~ 264 VAC | 12V | - | - | - | - | - | - | 85V | 375V | 3 kV | ||||
![]() |
TIS 300-148 RED | - | ![]() |
3828 | 0.00000000 | Traco Power | TIS (300W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 8.15" L x 3.27" W x 4.51" H (207.0mm x 83.1mm x 114.6mm) | Adjustable Output, IP20, Load Sharing | AC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9530 | 2 | 288W | 1 | 6A | 85% | 93 ~ 132 VAC, 187 ~ 264 VAC | 48V | - | - | - | - | - | - | |||||||
![]() |
TCL 060-148 | 112.8900 | ![]() |
20 | 0.00000000 | Traco Power | TCL (60W) | Box | Active | -10°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.94" L x 1.77" W x 2.95" H (100.1mm x 45.0mm x 74.9mm) | Adjustable Output, IP20 | TCL 060 | AC or DC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1245 | EAR99 | 8504.40.9520 | 10 | 60W | 1 | 1.25A | 88% | 85 ~ 264 VAC | 48V | - | - | - | - | - | - | 85V | 375V | 3 kV | ||
![]() |
TSP 360-124 | 270.2000 | ![]() |
35 | 0.00000000 | Traco Power | TSP (360W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 4.92" L x 3.15" W x 4.92" H (125.0mm x 80.0mm x 125.0mm) | Adjustable Output, IP20, Remote On/Off, Universal Input | TSP 360 | AC | CB, CE, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1009 | EAR99 | 8504.40.9530 | 10 | 360W | 1 | 15A | 87% | 85 ~ 264 VAC | 24V | - | - | - | - | - | - | |||||
![]() |
TSP 600-124 EX | 428.7700 | ![]() |
10 | 0.00000000 | Traco Power | TSP-EX (600W) | Box | Active | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 6.50" L x 4.92" W x 4.92" H (165.1mm x 125.0mm x 125.0mm) | Adjustable Output, IP20, Remote On/Off, Universal Input | TSP 600 | AC | CB, CE, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 10 | 600W | 1 | 25A | 87% | 85 ~ 132 VAC, 187 ~ 264 VAC | 24V | - | - | - | - | - | - | ||||||
![]() |
TSP 090-124 | 126.9700 | ![]() |
45 | 0.00000000 | Traco Power | TSP (90-96W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 4.33" L x 1.38" W x 4.33" H (110.0mm x 35.1mm x 110.0mm) | Adjustable Output, IP20, Remote On/Off, Universal Input | TSP 090 | AC | CB, CE, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1348 | EAR99 | 8504.40.9520 | 10 | 90W | 1 | 3.75A | 87% | 85 ~ 264 VAC | 24V | - | - | - | - | - | - | |||||
![]() |
TPC 055-148 | 86.7000 | ![]() |
1 | 0.00000000 | Traco Power | TPC (55W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.80" L x 1.77" W x 3.54" H (96.5mm x 45.0mm x 89.9mm) | Adjustable Output, IP20, Universal Input | TPC 055 | AC or DC | CB, CE, cCSAus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 10 | 55W | 1 | 1.15A | 87% | 85 ~ 264 VAC | 48V | - | - | - | - | - | - | 90V | 375V | ||||
![]() |
TIS 300-124 | - | ![]() |
1799 | 0.00000000 | Traco Power | TIS (300W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 8.15" L x 3.27" W x 4.51" H (207.0mm x 83.1mm x 114.6mm) | Adjustable Output, IP20 | AC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1101 | EAR99 | 8504.40.9530 | 2 | 288W | 1 | 12A | 85% | 93 ~ 132 VAC, 187 ~ 264 VAC | 24V | - | - | - | - | - | - | ||||||
![]() |
TBLC 25-105 | 69.5900 | ![]() |
6583 | 0.00000000 | Traco Power | TBLC (25W) | Box | Active | -25°C ~ 70°C (With Derating) | Household Appliances, Industrial, ITE (Commercial) | 2.15" L x 1.42" W x 3.52" H (54.6mm x 36.1mm x 89.4mm) | Adjustable Output, IP20, Universal Input | TBLC 25 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 20W | 1 | 4A | 82% | 85 ~ 264 VAC | 5V | - | - | - | - | - | - | 3 kV | |||||
![]() |
TIS 500-124-230 | - | ![]() |
3419 | 0.00000000 | Traco Power | TIS (500W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 8.66" L x 3.27" W x 5.12" H (220.0mm x 83.1mm x 130.0mm) | Adjustable Output, IP20 | AC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9530 | 2 | 480W | 1 | 20A | 90% | 187 ~ 264 VAC | 24V | - | - | - | - | - | - | |||||||
![]() |
TSPC 050-112 | 92.4800 | ![]() |
1806 | 0.00000000 | Traco Power | TSPC (50W) | Box | Active | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 3.56" L x 1.45" W x 4.33" H (90.4mm x 36.8mm x 110.0mm) | Adjustable Output, IP20, Universal Input | TSPC 050 | AC | CB, CE | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 48W | 1 | 4A | 93% | 85 ~ 264 VAC | 12V | - | - | - | - | - | - | ||||||
![]() |
TSP 600-124 | 359.2100 | ![]() |
9 | 0.00000000 | Traco Power | TSP (600W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 6.50" L x 4.92" W x 4.92" H (165.1mm x 125.0mm x 125.0mm) | Adjustable Output, IP20, Remote On/Off, Universal Input | TSP 600 | AC | CB, CE, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1258 | EAR99 | 8504.40.9540 | 10 | 600W | 1 | 25A | 87% | 85 ~ 132 VAC, 187 ~ 264 VAC | 24V | - | - | - | - | - | - | |||||
![]() |
TIB 240-148EX | 186.2600 | ![]() |
8724 | 0.00000000 | Traco Power | TIB 240EX (240W) | Box | Active | -40°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 4.50" L x 1.89" W x 4.89" H (114.2mm x 48.0mm x 124.2mm) | Adjustable Output, PFC, Universal Input | TIB 240 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-3311 | EAR99 | 8504.40.9530 | 10 | 240W | 1 | 5A | 95% | 85 ~ 264 VAC | 48V | - | - | - | - | - | - | 4.25 kV | ||||
![]() |
TIB 240-124BCMU | 273.8700 | ![]() |
5 | 0.00000000 | Traco Power | TIB-BCMU (240W) | Box | Active | 0°C ~ 60°C | ITE (Commercial), Laboratory | 4.50" L x 1.89" W x 4.89" H (114.2mm x 48.0mm x 124.2mm) | Adjustable Output | DC | CB, CE, cURus, UKCA | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TIB240-124BCMU | EAR99 | 8504.40.9530 | 10 | 240W | 1 | 10A | 98% | - | 24V | - | - | - | - | - | - | 24V | 28.5V | 500 V | 61010-1; 62368-1 | ||
![]() |
TIS 75-112 | - | ![]() |
4229 | 0.00000000 | Traco Power | TIS (75W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 3.54" L x 2.23" W x 4.51" H (89.9mm x 56.6mm x 114.6mm) | Adjustable Output, IP20 | AC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 2 | 72W | 1 | 6A | 85% | 93 ~ 132 VAC, 187 ~ 264 VAC | 12V | - | - | - | - | - | - | |||||||
![]() |
TBL 015-124 | 62.8700 | ![]() |
6 | 0.00000000 | Traco Power | TBL (15W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 2.15" L x 1.04" W x 3.52" H (54.5mm x 26.4mm x 89.4mm) | Adjustable Output, IP20, Universal Input | TBL 015 | AC | CB, CE, CSAus, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1342 | EAR99 | 8504.40.9510 | 10 | 15W | 1 | 630mA | 81% | 85 ~ 264 VAC | 24V | - | - | - | - | - | - | |||||
![]() |
TIB 120-112EX | 141.6500 | ![]() |
8 | 0.00000000 | Traco Power | TIB 120EX (120W) | Box | Active | -40°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 4.50" L x 1.42" W x 4.89" H (114.2mm x 36.0mm x 124.2mm) | Adjustable Output, PFC, Universal Input | TIB 120 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 10 | 120W | 1 | 10A | 94% | 85 ~ 264 VAC | 12V | - | - | - | - | - | - | 4.25 kV | |||||
![]() |
TBLC 75-112 | 100.0500 | ![]() |
9 | 0.00000000 | Traco Power | TBLC (75W) | Box | Active | -25°C ~ 70°C (With Derating) | Household Appliances, Industrial, ITE (Commercial) | 2.15" L x 2.83" W x 3.52" H (54.6mm x 71.9mm x 89.4mm) | Adjustable Output, IP20, Universal Input | TBLC 75 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 10 | 72W | 1 | 6A | 89% | 85 ~ 264 VAC | 12V | - | - | - | - | - | - | 3 kV | |||||
![]() |
TSPC 120-124 | 141.1600 | ![]() |
7254 | 0.00000000 | Traco Power | TSPC (120W) | Box | Active | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 4.33" L x 1.81" W x 4.33" H (110.0mm x 46.0mm x 110.0mm) | Adjustable Output | TSPC 120 | AC | CB, CE | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1114 | EAR99 | 8504.40.9520 | 10 | 120W | 1 | 5A | 93% | 85 ~ 132 VAC, 187 ~ 264 VAC | 24V | - | - | - | - | - | - | |||||
![]() |
TSP 360-148 EX | 332.6150 | ![]() |
9614 | 0.00000000 | Traco Power | TSP-EX (360W) | Box | Active | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 4.92" L x 3.15" W x 4.92" H (125.0mm x 80.0mm x 125.0mm) | Adjustable Output, IP20, Remote On/Off, Universal Input | TSP 360 | AC | CB, CE, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9530 | 10 | 360W | 1 | 7.5A | 87% | 85 ~ 132 VAC, 187 ~ 264 VAC | 48V | - | - | - | - | - | - | ||||||
![]() |
TBLC 90-124 | 92.9400 | ![]() |
10 | 0.00000000 | Traco Power | TBLC (90W) | Box | Active | -25°C ~ 70°C (With Derating) | Household Appliances, Industrial, ITE (Commercial) | 2.15" L x 3.54" W x 3.52" H (54.6mm x 89.9mm x 89.4mm) | Adjustable Output, IP20, Universal Input | TBLC 90 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 10 | 90W | 1 | 3.75A | 90% | 85 ~ 264 VAC | 24V | - | - | - | - | - | - | 3 kV | |||||
![]() |
TSPC 080-124 | 97.6100 | ![]() |
3871 | 0.00000000 | Traco Power | TSPC (80W) | Box | Active | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 4.33" L x 1.57" W x 4.33" H (110.0mm x 39.9mm x 110.0mm) | Adjustable Output | TSPC 080 | AC | CB, CE | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1113 | EAR99 | 8504.40.9520 | 10 | 79W | 1 | 3.3A | 93% | 85 ~ 132 VAC, 187 ~ 264 VAC | 24V | - | - | - | - | - | - | |||||
![]() |
TIS 150-124 SIG | - | ![]() |
4242 | 0.00000000 | Traco Power | TIS (150W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 6.18" L x 2.23" W x 4.51" H (157.0mm x 56.6mm x 114.6mm) | Adjustable Output, IP20, Remote On/Off | AC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 2 | 144W | 1 | 6A | 85% | 93 ~ 132 VAC, 187 ~ 264 VAC | 24V | - | - | - | - | - | - | |||||||
![]() |
TSP 180-124 WR | 264.3000 | ![]() |
6 | 0.00000000 | Traco Power | TSP-WR (180-192W) | Box | Active | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 4.33" L x 2.13" W x 4.33" H (110.0mm x 54.1mm x 110.0mm) | Adjustable Output, Hot Swappable, IP20, Remote On/Off | TSP 180 | AC | CB, CE, cCSAus, GS | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1256 | EAR99 | 8504.40.9530 | 10 | 180W | 1 | 7.5A | 88% | 85 ~ 132 VAC, 187 ~ 550 VAC | 24V | - | - | - | - | - | - | |||||
![]() |
TSP 360-148 | 332.4400 | ![]() |
25 | 0.00000000 | Traco Power | TSP (360W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 4.92" L x 3.15" W x 4.92" H (125.0mm x 80.0mm x 125.0mm) | Adjustable Output, IP20, Remote On/Off, Universal Input | TSP 360 | AC | CB, CE, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9530 | 10 | 360W | 1 | 7.5A | 87% | 85 ~ 132 VAC, 187 ~ 264 VAC | 48V | - | - | - | - | - | - | ||||||
![]() |
TIB 120-124 | 118.8700 | ![]() |
12 | 0.00000000 | Traco Power | TIB 120 (120W) | Box | Active | -40°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 4.50" L x 1.42" W x 4.89" H (114.2mm x 36.0mm x 124.2mm) | Adjustable Output, PFC, Universal Input | TIB 120 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1097 | EAR99 | 8504.40.9520 | 10 | 120W | 1 | 5A | 93.5% | 85 ~ 264 VAC | 24V | - | - | - | - | - | - | 4.25 kV | ||||
![]() |
TBL 015-112 | 62.8700 | ![]() |
7 | 0.00000000 | Traco Power | TBL (15W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 2.15" L x 1.04" W x 3.52" H (54.5mm x 26.4mm x 89.4mm) | Adjustable Output, IP20, Universal Input | TBL 015 | AC | CB, CE, CSAus, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1235 | EAR99 | 8504.40.9510 | 10 | 15W | 1 | 1.25A | 79% | 85 ~ 264 VAC | 12V | - | - | - | - | - | - | |||||
![]() |
TIB 080-148EX | 109.4100 | ![]() |
8887 | 0.00000000 | Traco Power | TIB 080EX (80W) | Box | Active | -40°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 3.71" L x 1.26" W x 4.50" H (94.2mm x 32.0mm x 114.2mm) | Adjustable Output, PFC, Universal Input | TIB 080 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-3306 | EAR99 | 8504.40.9520 | 10 | 82W | 1 | 1.7A | 90% | 85 ~ 264 VAC | 48V | - | - | - | - | - | - | 4.25 kV | ||||
![]() |
TPC 055-112 | 86.7000 | ![]() |
10 | 0.00000000 | Traco Power | TPC (55W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.80" L x 1.77" W x 3.54" H (96.5mm x 45.0mm x 89.9mm) | Adjustable Output, IP20, Universal Input | TPC 055 | AC or DC | CB, CE, cCSAus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 42W | 1 | 3.5A | 87% | 85 ~ 264 VAC | 12V | - | - | - | - | - | - | 90V | 375V |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse