Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Features | Base Product Number | Input Type | Approval Agency | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Current - Output (Max) | Efficiency | AC Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | DC Voltage - Input (Min) | DC Voltage - Input (Max) | Voltage - Isolation |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
TSP 090-148 | 157.7200 | ![]() |
15 | 0.00000000 | Traco Power | TSP (90-96W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 4.33" L x 1.38" W x 4.33" H (110.0mm x 35.1mm x 110.0mm) | Adjustable Output, IP20, Remote On/Off, Universal Input | TSP 090 | AC | CB, CE, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1108 | EAR99 | 8504.40.9520 | 10 | 96W | 1 | 2A | 87% | 85 ~ 264 VAC | 48V | - | - | - | - | - | - | ||||
![]() |
TBLC 50-124 | 78.6700 | ![]() |
34 | 0.00000000 | Traco Power | TBLC (50W) | Box | Active | -25°C ~ 70°C (With Derating) | Household Appliances, Industrial, ITE (Commercial) | 2.15" L x 2.13" W x 3.52" H (54.6mm x 54.1mm x 89.4mm) | Adjustable Output, IP20, Universal Input | TBLC 50 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 50W | 1 | 2.1A | 89% | 85 ~ 264 VAC | 24V | - | - | - | - | - | - | 3 kV | ||||
![]() |
TBL 030-124 | 79.3400 | ![]() |
8 | 0.00000000 | Traco Power | TBL (30W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 2.15" L x 2.07" W x 3.52" H (54.5mm x 52.6mm x 89.4mm) | Adjustable Output, IP20, Universal Input | TBL 030 | AC | CB, CE, CSAus, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1237 | EAR99 | 8504.40.9510 | 10 | 30W | 1 | 1.25A | 83% | 85 ~ 264 VAC | 24V | - | - | - | - | - | - | ||||
![]() |
TIB 480-148 | 260.3100 | ![]() |
8 | 0.00000000 | Traco Power | TIB 480 (480W) | Box | Active | -40°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 4.50" L x 3.23" W x 4.89" H (114.2mm x 82.0mm x 124.2mm) | Adjustable Output, PFC, Remote On/Off, Universal Input | TIB 480 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-3319 | EAR99 | 8504.40.9530 | 10 | 480W | 1 | 10A | 95% | 85 ~ 264 VAC | 48V | - | - | - | - | - | - | 4.25 kV | |||
![]() |
TIS 600-148 SIG | - | ![]() |
8338 | 0.00000000 | Traco Power | TIS (600W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 9.57" L x 3.25" W x 6.98" H (243.1mm x 82.6mm x 177.3mm) | Adjustable Output, IP20, Remote On/Off | AC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 2 | 576W | 1 | 12A | 90% | 93 ~ 132 VAC, 187 ~ 264 VAC | 48V | - | - | - | - | - | - | ||||||
TIB 120-148 | 136.6600 | ![]() |
13 | 0.00000000 | Traco Power | TIB 120 (120W) | Box | Active | -40°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 4.50" L x 1.42" W x 4.89" H (114.2mm x 36.0mm x 124.2mm) | Adjustable Output, PFC, Universal Input | TIB 120 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-3317 | EAR99 | 8504.40.9520 | 10 | 120W | 1 | 2.5A | 94% | 85 ~ 264 VAC | 48V | - | - | - | - | - | - | 4.25 kV | ||||
![]() |
TIB 080-124EX | 96.2000 | ![]() |
102 | 0.00000000 | Traco Power | TIB 080EX (80W) | Box | Active | -40°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 3.71" L x 1.26" W x 4.50" H (94.2mm x 32.0mm x 114.2mm) | Adjustable Output, PFC, Universal Input | TIB 080 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-3305 | EAR99 | 8504.40.9520 | 10 | 82W | 1 | 3.4A | 90% | 85 ~ 264 VAC | 24V | - | - | - | - | - | - | 4.25 kV | |||
![]() |
TIB 480-124 | 230.5700 | ![]() |
4607 | 0.00000000 | Traco Power | TIB 480 (480W) | Box | Active | -40°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 4.50" L x 3.23" W x 4.89" H (114.2mm x 82.0mm x 124.2mm) | Adjustable Output, PFC, Universal Input | TIB 480 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9530 | 10 | 480W | 1 | 20A | 94.7% | 85 ~ 264 VAC | 24V | - | - | - | - | - | - | 4.25 kV | ||||
![]() |
TBL 150-124 | 165.0200 | ![]() |
3 | 0.00000000 | Traco Power | TBL (150W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 6.89" L x 2.15" W x 3.52" H (175.0mm x 54.5mm x 89.4mm) | Adjustable Output, IP20 | TBL 150 | AC | CB, CE, CSAus, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1093 | EAR99 | 8504.40.9520 | 10 | 150W | 1 | 6.25A | 87% | 85 ~ 132 VAC, 187 ~ 264 VAC | 24V | - | - | - | - | - | - | ||||
![]() |
TCL 012-124 DC | 89.5300 | ![]() |
13 | 0.00000000 | Traco Power | TCL-DC (24 ~ 60W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.94" L x 1.06" W x 2.95" H (100.1mm x 26.9mm x 74.9mm) | Adjustable Output, IP20 | TCL 012 | DC | CB, cULus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 10 | 24W | 1 | 1A | 86% | 24V | - | - | - | - | - | - | 9.5V | 18V | 1.5 kV | |||
![]() |
TPC 030-105 | 70.5800 | ![]() |
2 | 0.00000000 | Traco Power | TPC (30W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.80" L x 1.04" W x 3.54" H (96.5mm x 26.4mm x 89.9mm) | Adjustable Output, IP20, Universal Input | TPC 030 | AC or DC | CB, CE, cCSAus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 20W | 1 | 4A | 79% | 85 ~ 264 VAC | 5V | - | - | - | - | - | - | 90V | 375V | |||
![]() |
TCL 240-124 | 235.1500 | ![]() |
11 | 0.00000000 | Traco Power | TCL (240W) | Box | Active | -10°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 4.92" L x 3.35" W x 4.33" H (125.0mm x 85.1mm x 110.0mm) | Adjustable Output, IP20 | TCL 240 | AC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1095 | EAR99 | 8504.40.9530 | 10 | 240W | 1 | 10A | 88% | 85 ~ 132 VAC, 187 ~ 264 VAC | 24V | - | - | - | - | - | - | 3 kV | |||
![]() |
TSP 070-112 | 161.8100 | ![]() |
7 | 0.00000000 | Traco Power | TSP (72W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 4.33" L x 1.38" W x 4.33" H (110.0mm x 35.1mm x 110.0mm) | Adjustable Output, IP20, Remote On/Off, Universal Input | TSP 070 | AC | CB, CE, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1106 | EAR99 | 8504.40.9520 | 10 | 72W | 1 | 6A | 87% | 85 ~ 264 VAC | 12V | - | - | - | - | - | - | ||||
![]() |
TPC 080-124 | 94.7000 | ![]() |
10 | 0.00000000 | Traco Power | TPC (80W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.80" L x 2.48" W x 3.54" H (96.5mm x 63.0mm x 89.9mm) | Adjustable Output, IP20, Universal Input | TPC 080 | AC or DC | CB, CE, cCSAus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 10 | 79W | 1 | 3.3A | 87% | 85 ~ 264 VAC | 24V | - | - | - | - | - | - | 90V | 375V | |||
![]() |
TIS 150-148 RED | - | ![]() |
1010 | 0.00000000 | Traco Power | TIS (150W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 6.18" L x 2.23" W x 4.51" H (157.0mm x 56.6mm x 114.6mm) | Adjustable Output, IP20, Load Sharing | AC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 2 | 144W | 1 | 3A | 85% | 93 ~ 132 VAC, 187 ~ 264 VAC | 48V | - | - | - | - | - | - | ||||||
![]() |
TSP 140-112 EX | 208.2100 | ![]() |
40 | 0.00000000 | Traco Power | TSP-EX (144W) | Box | Active | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 4.33" L x 2.13" W x 4.33" H (110.0mm x 54.1mm x 110.0mm) | Adjustable Output, IP20, Remote On/Off, Universal Input | TSP 140 | AC | CB, CE, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 10 | 144W | 1 | 12A | 87% | 85 ~ 132 VAC, 187 ~ 264 VAC | 12V | - | - | - | - | - | - | |||||
![]() |
TSP960-124-3PAC400 | - | ![]() |
5344 | 0.00000000 | Traco Power | TSP-3P (960W) | Box | Obsolete | -25°C ~ 60°C | Hazardous Locations, Industrial, ITE (Commercial) | 6.50" L x 5.18" W x 4.92" H (165.1mm x 131.6mm x 125.0mm) | IP20 | AC | CB, CE, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 10 | 960W | 1 | 40A | 92% | 320 ~ 440 VAC (3 Phase) | 24V | - | - | - | - | - | - | ||||||
![]() |
TSPC 240-148 | 180.2400 | ![]() |
4 | 0.00000000 | Traco Power | TSPC (240W) | Box | Active | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 4.33" L x 2.36" W x 4.33" H (110.0mm x 59.9mm x 110.0mm) | Adjustable Output, IP20, Universal Input | TSPC 240 | AC | CB, CE | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9530 | 10 | 240W | 1 | 5A | 93% | 85 ~ 132 VAC, 187 ~ 264 VAC | 48V | - | - | - | - | - | - | |||||
![]() |
TSP 140-112 | 197.4300 | ![]() |
3 | 0.00000000 | Traco Power | TSP (144W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 4.33" L x 2.13" W x 4.33" H (110.0mm x 54.1mm x 110.0mm) | Adjustable Output, IP20, Remote On/Off, Universal Input | TSP 140 | AC | CB, CE, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1109 | EAR99 | 8504.40.9520 | 10 | 144W | 1 | 12A | 87% | 85 ~ 132 VAC, 187 ~ 264 VAC | 12V | - | - | - | - | - | - | ||||
![]() |
TIB 080-124 | 86.8400 | ![]() |
98 | 0.00000000 | Traco Power | TIB 080 (80W) | Box | Active | -40°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.71" L x 1.26" W x 4.50" H (94.2mm x 32.0mm x 114.2mm) | Adjustable Output, PFC, Universal Input | TIB 080 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1096 | EAR99 | 8504.40.9520 | 10 | 82W | 1 | 3.4A | 90% | 85 ~ 264 VAC | 24V | - | - | - | - | - | - | 4.25 kV | |||
![]() |
TSP 360-124 WR | 402.5400 | ![]() |
6572 | 0.00000000 | Traco Power | TSP-WR (360W) | Box | Active | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 4.92" L x 3.15" W x 4.92" H (125.0mm x 80.0mm x 125.0mm) | Adjustable Output, IP20, Remote On/Off, Universal Input | TSP 360 | AC | CB, CE, cCSAus, GS | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9530 | 10 | 360W | 1 | 15A | 88% | 85 ~ 132 VAC, 187 ~ 550 VAC | 24V | - | - | - | - | - | - | |||||
![]() |
TBLC 06-124 | 48.2000 | ![]() |
4 | 0.00000000 | Traco Power | TBLC (6W) | Box | Active | -25°C ~ 70°C (With Derating) | Household Appliances, Industrial, ITE (Commercial) | 2.15" L x 0.71" W x 3.52" H (54.6mm x 18.0mm x 89.4mm) | Adjustable Output, IP20, Universal Input | TBLC 06 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 6W | 1 | 250mA | 79% | 85 ~ 264 VAC | 24V | - | - | - | - | - | - | 3 kV | ||||
![]() |
TCL 120-124 | 146.8900 | ![]() |
6 | 0.00000000 | Traco Power | TCL (120W) | Box | Active | -10°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.94" L x 3.35" W x 2.95" H (100.1mm x 85.1mm x 74.9mm) | Adjustable Output, IP20 | TCL 120 | AC or DC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1246 | EAR99 | 8504.40.9520 | 10 | 120W | 1 | 5A | 88% | 85 ~ 264 VAC | 24V | - | - | - | - | - | - | 85V | 375V | 3 kV | |
![]() |
TCL 024-124 | 84.1900 | ![]() |
10 | 0.00000000 | Traco Power | TCL (24W) | Box | Active | -10°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.94" L x 1.06" W x 2.95" H (100.1mm x 26.9mm x 74.9mm) | Adjustable Output, IP20 | TCL 024 | AC or DC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1345 | EAR99 | 8504.40.9510 | 10 | 24W | 1 | 1A | 88% | 85 ~ 264 VAC | 24V | - | - | - | - | - | - | 85V | 375V | 3 kV | |
![]() |
TIB 480-148EX | 273.6200 | ![]() |
17 | 0.00000000 | Traco Power | TIB 480EX (480W) | Box | Active | -40°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 4.50" L x 3.23" W x 4.89" H (114.2mm x 82.0mm x 124.2mm) | Adjustable Output, PFC, Remote On/Off, Universal Input | TIB 480 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-3313 | EAR99 | 8504.40.9530 | 10 | 480W | 1 | 10A | 95% | 85 ~ 264 VAC | 48V | - | - | - | - | - | - | 4.25 kV | |||
![]() |
TIS 300-124 UDS | - | ![]() |
5820 | 0.00000000 | Traco Power | TIS (300W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 8.15" L x 3.27" W x 4.51" H (207.0mm x 83.1mm x 114.6mm) | Adjustable Output, IP20, Remote On/Off | AC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9530 | 2 | 288W | 1 | 12A | 85% | 93 ~ 132 VAC, 187 ~ 264 VAC | 24V | - | - | - | - | - | - | ||||||
![]() |
TPC 055-124 | 84.0800 | ![]() |
10 | 0.00000000 | Traco Power | TPC (55W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.80" L x 1.77" W x 3.54" H (96.5mm x 45.0mm x 89.9mm) | Adjustable Output, IP20, Universal Input | TPC 055 | AC or DC | CB, CE, cCSAus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1105 | EAR99 | 8504.40.9520 | 10 | 55W | 1 | 2.3A | 87% | 85 ~ 264 VAC | 24V | - | - | - | - | - | - | 90V | 375V | ||
![]() |
TBLC 15-105 | 59.8100 | ![]() |
10 | 0.00000000 | Traco Power | TBLC (15W) | Box | Active | -25°C ~ 70°C (With Derating) | Household Appliances, Industrial, ITE (Commercial) | 2.15" L x 1.06" W x 3.52" H (54.6mm x 26.9mm x 89.4mm) | Adjustable Output, IP20, Universal Input | TBLC 15 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 12W | 1 | 2.4A | 81% | 85 ~ 264 VAC | 5V | - | - | - | - | - | - | 3 kV | ||||
![]() |
TIS 300-172 | - | ![]() |
9010 | 0.00000000 | Traco Power | TIS (300W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 8.15" L x 3.27" W x 4.51" H (207.0mm x 83.1mm x 114.6mm) | Adjustable Output, IP20 | AC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | TIS300-172 | EAR99 | 8504.40.9530 | 2 | 302W | 1 | 4.2A | 85% | 93 ~ 132 VAC, 187 ~ 264 VAC | 72V | - | - | - | - | - | - | |||||
![]() |
TIS 500-124-115 | - | ![]() |
3466 | 0.00000000 | Traco Power | TIS (500W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 8.66" L x 3.27" W x 5.12" H (220.0mm x 83.1mm x 130.0mm) | Adjustable Output, IP20 | AC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9530 | 2 | 480W | 1 | 20A | 90% | 93 ~ 132 VAC | 24V | - | - | - | - | - | - |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse