Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
TPP 40-115E-J | 72.1100 | ![]() |
7 | 0.00000000 | Traco Power | TPP 40E-J (40W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 4.30" L x 2.20" W x 1.20" H (109.2mm x 55.9mm x 30.5mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | CB, CE, CSA, cURus, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP40-115E-J | EAR99 | 8504.40.9510 | 1 | 40W | 1 | 92% | 15V | - | - | - | - | - | No | 4 kV | 60601-1; 62368-1 | 2.67 A | ||
![]() |
TPP 65-105E-J | 80.2800 | ![]() |
1195 | 0.00000000 | Traco Power | TPP 65E-J (65W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 4.30" L x 2.20" W x 1.20" H (109.2mm x 55.9mm x 30.5mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | CB, CE, CSA, cURus, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP65-105E-J | EAR99 | 8504.40.9510 | 1 | 50W | 1 | 90% | 5V | - | - | - | - | - | No | 4 kV | 60601-1; 62368-1 | 10 A | ||
![]() |
TPP 65-112E-J | 75.3800 | ![]() |
15 | 0.00000000 | Traco Power | TPP 65E-J (65W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 4.30" L x 2.20" W x 1.20" H (109.2mm x 55.9mm x 30.5mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | CB, CE, CSA, cURus, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP65-112E-J | EAR99 | 8504.40.9520 | 1 | 65W | 1 | 93% | 12V | - | - | - | - | - | No | 4 kV | 60601-1; 62368-1 | 5.42 A | ||
![]() |
TPP 65-148E-J | 72.9400 | ![]() |
10 | 0.00000000 | Traco Power | TPP 65E-J (65W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 4.30" L x 2.20" W x 1.20" H (109.2mm x 55.9mm x 30.5mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | CB, CE, CSA, cURus, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP65-148E-J | EAR99 | 8504.40.9520 | 1 | 65W | 1 | 93% | 48V | - | - | - | - | - | No | 4 kV | 60601-1; 62368-1 | 1.36 A | ||
![]() |
TPP 40-148E-J | 69.0600 | ![]() |
10 | 0.00000000 | Traco Power | TPP 40E-J (40W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 4.30" L x 2.20" W x 1.20" H (109.2mm x 55.9mm x 30.5mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | CB, CE, CSA, cURus, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP40-148E-J | EAR99 | 8504.40.9510 | 1 | 40W | 1 | 93% | 48V | - | - | - | - | - | No | 4 kV | 60601-1; 62368-1 | 840 mA | ||
![]() |
TPI 180-136A-M | 100.1300 | ![]() |
1866 | 0.00000000 | Traco Power | TPI 180A-M (180W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial) | 3.00" L x 2.00" W x 1.24" H (76.2mm x 50.8mm x 31.5mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, PFC, Standby Output, Universal Input | CB, CE, cURus, EAC, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPI180-136A-M | EAR99 | 8504.40.9520 | 1 | 150W (180W Forced Air) | 1 | 93% | 36V | - | - | - | - | - | No | 3 kV | 62368-1 | 5 A | ||
![]() |
TPI 180-124-M | 116.0200 | ![]() |
3575 | 0.00000000 | Traco Power | TPI 180-M (180W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial) | 3.60" L x 2.44" W x 1.75" H (91.4mm x 62.0mm x 44.5mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, PFC, Standby Output, Universal Input | CB, CE, cURus, EAC, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPI180-124-M | EAR99 | 8504.40.9520 | 1 | 150W (180W Forced Air) | 1 | 94% | 24V | - | - | - | - | - | No | 3 kV | 62368-1 | 7.5 A | ||
![]() |
TPP 180-136-M | 126.5600 | ![]() |
10 | 0.00000000 | Traco Power | TPP 180-M (180W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 3.60" L x 2.44" W x 1.75" H (91.4mm x 62.0mm x 44.5mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, PFC, Standby Output, Universal Input | CB, CE, cURus, EAC, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP180-136-M | EAR99 | 8504.40.9520 | 1 | 150W (180W Forced Air) | 1 | 93% | 36V | - | - | - | - | - | No | 4 kV | 60601-1; 62368-1 | 5 A | ||
![]() |
TPP 180-124-M | 126.5600 | ![]() |
4320 | 0.00000000 | Traco Power | TPP 180-M (180W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 3.60" L x 2.44" W x 1.75" H (91.4mm x 62.0mm x 44.5mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, PFC, Standby Output, Universal Input | CB, CE, cURus, EAC, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP180-124-M | EAR99 | 8504.40.9530 | 1 | 150W (180W Forced Air) | 1 | 94% | 24V | - | - | - | - | - | No | 4 kV | 60601-1; 62368-1 | 7.5 A | ||
![]() |
TPI 180-112-M | 116.0200 | ![]() |
9024 | 0.00000000 | Traco Power | TPI 180-M (180W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial) | 3.60" L x 2.44" W x 1.75" H (91.4mm x 62.0mm x 44.5mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, PFC, Standby Output, Universal Input | CB, CE, cURus, EAC, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPI180-112-M | EAR99 | 8504.40.9530 | 1 | 150W (180W Forced Air) | 1 | 92% | 12V | - | - | - | - | - | No | 3 kV | 62368-1 | 15 A | ||
![]() |
TPP 180-115A-M | 110.4200 | ![]() |
16 | 0.00000000 | Traco Power | TPP 180A-M (180W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 3.00" L x 2.00" W x 1.24" H (76.2mm x 50.8mm x 31.5mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, PFC, Standby Output, Universal Input | CB, CE, cURus, EAC, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP180-115A-M | EAR99 | 8504.40.9520 | 1 | 150W (180W Forced Air) | 1 | 92% | 15V | - | - | - | - | - | No | 4 kV | 60601-1; 62368-1 | 12 A | ||
![]() |
TPP 180-153A-M | 110.4200 | ![]() |
5 | 0.00000000 | Traco Power | TPP 180A-M (180W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 3.00" L x 2.00" W x 1.24" H (76.2mm x 50.8mm x 31.5mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, PFC, Standby Output, Universal Input | CB, CE, cURus, EAC, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP180-153A-M | EAR99 | 8504.40.9520 | 1 | 150W (180W Forced Air) | 1 | 93% | 53V | - | - | - | - | - | No | 4 kV | 60601-1; 62368-1 | 3.4 A | ||
![]() |
TPI 180-115A-M | 100.1300 | ![]() |
20 | 0.00000000 | Traco Power | TPI 180A-M (180W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial) | 3.00" L x 2.00" W x 1.24" H (76.2mm x 50.8mm x 31.5mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, PFC, Standby Output, Universal Input | CB, CE, cURus, EAC, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPI180-115A-M | EAR99 | 8504.40.9520 | 1 | 150W (180W Forced Air) | 1 | 92% | 15V | - | - | - | - | - | No | 3 kV | 62368-1 | 12 A | ||
![]() |
TPI 300-148-M | 162.7300 | ![]() |
5 | 0.00000000 | Traco Power | TPI 300-M (300W) | Box | Active | -40°C ~ 80°C (With Derating) | ITE (Commercial) | 4.60" L x 2.44" W x 2.32" H (116.8mm x 62.0mm x 58.9mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | CB, CE, cURus, EAC, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPI300-148-M | EAR99 | 8504.40.9530 | 1 | 300W | 1 | 93% | 48V | - | - | - | - | - | No | 3 kV | 62368-1 | 6.25 A | ||
![]() |
TPP 300-115A-M | 134.9400 | ![]() |
2 | 0.00000000 | Traco Power | TPP 300A-M (300W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 4.00" L x 2.00" W x 1.26" H (101.6mm x 50.8mm x 32.0mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | CB, CE, cURus, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP300-115A-M | EAR99 | 8504.40.9530 | 1 | 180W (300W Forced Air) | 1 | 92% | 15V | - | - | - | - | - | No | 3 kV | 60601-1; 62368-1 | 20 A | ||
![]() |
TPI 300-115-M | 162.7300 | ![]() |
15 | 0.00000000 | Traco Power | TPI 300-M (300W) | Box | Active | -40°C ~ 80°C (With Derating) | ITE (Commercial) | 4.60" L x 2.44" W x 2.32" H (116.8mm x 62.0mm x 58.9mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | CB, CE, cURus, EAC, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPI300-115-M | EAR99 | 8504.40.9530 | 1 | 300W | 1 | 92% | 15V | - | - | - | - | - | No | 3 kV | 62368-1 | 20 A | ||
![]() |
TPP 300-124A-M | 134.9400 | ![]() |
83 | 0.00000000 | Traco Power | TPP 300A-M (300W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 4.00" L x 2.00" W x 1.26" H (101.6mm x 50.8mm x 32.0mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | CB, CE, cURus, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP300-124A-M | EAR99 | 8504.40.9530 | 1 | 180W (300W Forced Air) | 1 | 93% | 24V | - | - | - | - | - | No | 3 kV | 60601-1; 62368-1 | 12.5 A | ||
![]() |
TPP 300-115-M | 168.3100 | ![]() |
8 | 0.00000000 | Traco Power | TPP 300-M (300W) | Box | Active | -40°C ~ 80°C (With Derating) | ITE (Commercial), Medical | 4.60" L x 2.44" W x 2.32" H (116.8mm x 62.0mm x 58.9mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | CB, CE, cURus, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP300-115-M | EAR99 | 8504.40.9530 | 1 | 300W | 1 | 92% | 15V | - | - | - | - | - | No | 3 kV | 60601-1; 62368-1 | 20 A | ||
![]() |
TPI 300-124-M | 162.7300 | ![]() |
3488 | 0.00000000 | Traco Power | TPI 300-M (300W) | Box | Active | -40°C ~ 80°C (With Derating) | ITE (Commercial) | 4.60" L x 2.44" W x 2.32" H (116.8mm x 62.0mm x 58.9mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | CB, CE, cURus, EAC, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPI300-124-M | EAR99 | 8504.40.9530 | 1 | 300W | 1 | 93% | 24V | - | - | - | - | - | No | 3 kV | 62368-1 | 12.5 A | ||
![]() |
TPP 300-148-M | 168.3100 | ![]() |
2 | 0.00000000 | Traco Power | TPP 300-M (300W) | Box | Active | -40°C ~ 80°C (With Derating) | ITE (Commercial), Medical | 4.60" L x 2.44" W x 2.32" H (116.8mm x 62.0mm x 58.9mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | CB, CE, cURus, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP300-148-M | EAR99 | 8504.40.9530 | 1 | 300W | 1 | 93% | 48V | - | - | - | - | - | No | 3 kV | 60601-1; 62368-1 | 6.25 A | ||
![]() |
TPI 50-148A-J | 40.2600 | ![]() |
15 | 0.00000000 | Traco Power | TPI 50A-J (50W) | Box | Active | -40°C ~ 85°C | ITE (Commercial) | 3.00" L x 1.50" W x 1.30" H (76.2mm x 38.1mm x 33.0mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPI50-148A-J | EAR99 | 8504.40.9510 | 1 | 50W | 1 | 92% | 48V | - | - | - | - | - | No | 3 kV | 62368-1 | 1.045 A | ||
![]() |
TPI 50-112A-J | 40.2600 | ![]() |
25 | 0.00000000 | Traco Power | TPI 50A-J (50W) | Box | Active | -40°C ~ 85°C | ITE (Commercial) | 3.00" L x 1.50" W x 1.30" H (76.2mm x 38.1mm x 33.0mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPI50-112A-J | EAR99 | 8504.40.9510 | 1 | 50W | 1 | 93% | 12V | - | - | - | - | - | No | 3 kV | 62368-1 | 4.17 A | ||
![]() |
TPI 50-124A-J | 41.6900 | ![]() |
17 | 0.00000000 | Traco Power | TPI 50A-J (50W) | Box | Active | -40°C ~ 85°C | ITE (Commercial) | 3.00" L x 1.50" W x 1.30" H (76.2mm x 38.1mm x 33.0mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPI50-124A-J | EAR99 | 8504.40.9510 | 1 | 50W | 1 | 93% | 24V | - | - | - | - | - | No | 3 kV | 62368-1 | 2.085 A | ||
![]() |
TPI 50-153A-J | 40.2600 | ![]() |
20 | 0.00000000 | Traco Power | TPI 50A-J (50W) | Box | Active | -40°C ~ 85°C | ITE (Commercial) | 3.00" L x 1.50" W x 1.30" H (76.2mm x 38.1mm x 33.0mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPI50-153A-J | EAR99 | 8504.40.9510 | 1 | 50W | 1 | 92% | 53V | - | - | - | - | - | No | 3 kV | 62368-1 | 950 mA | ||
![]() |
TMPW 25-124-T | 33.5000 | ![]() |
20 | 0.00000000 | Traco Power | TMPW 25-T (25W) | Box | Active | -40°C ~ 70°C | Household Appliances, ITE (Commercial) | 3.48" L x 1.50" W x 0.95" H (88.4mm x 38.1mm x 24.1mm) | Chassis Mount | Enclosed | - | CB, CE, cURus, EAC, UKCA | 90 ~ 305 VAC, 100 ~ 430 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TMPW25-124-T | 1 | 25W | 1 | 87% | 24V | - | - | - | - | - | No | 4 kV | 60335-1; 62368-1 | 1.042 A | ||||
![]() |
TMPW 5-124-T | 19.4500 | ![]() |
20 | 0.00000000 | Traco Power | TMPW 5-T (5W) | Box | Active | -40°C ~ 70°C | Household Appliances, ITE (Commercial) | 2.17" L x 1.70" W x 0.91" H (55.1mm x 43.2mm x 23.1mm) | Chassis Mount | Enclosed | - | CB, CE, cURus, EAC, UKCA | 90 ~ 305 VAC, 100 ~ 430 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TMPW5-124-T | 1 | 5.04W | 1 | 83% | 24V | - | - | - | - | - | No | 4 kV | 60335-1; 62368-1 | 210 mA | ||||
![]() |
TMPW 25-112-T | 33.5000 | ![]() |
28 | 0.00000000 | Traco Power | TMPW 25-T (25W) | Box | Active | -40°C ~ 70°C | Household Appliances, ITE (Commercial) | 3.48" L x 1.50" W x 0.95" H (88.4mm x 38.1mm x 24.1mm) | Chassis Mount | Enclosed | - | CB, CE, cURus, EAC, UKCA | 90 ~ 305 VAC, 100 ~ 430 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TMPW25-112-T | 1 | 25W | 1 | 88% | 12V | - | - | - | - | - | No | 4 kV | 60335-1; 62368-1 | 2.083 A | ||||
![]() |
TML 20115C | 65.9600 | ![]() |
9 | 0.00000000 | Traco Power | TML (20W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.15" W x 1.09" H (96.0mm x 54.6mm x 27.7mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TML 20115 | CB, CE, cURus | 90 ~ 264 VAC, 100 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 20W | 1 | 84% | 15V | - | - | - | - | - | No | 3 kV | 1.34 A | |||
![]() |
TPP 65-115E-J | 75.3800 | ![]() |
10 | 0.00000000 | Traco Power | TPP 65E-J (65W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 4.30" L x 2.20" W x 1.20" H (109.2mm x 55.9mm x 30.5mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | CB, CE, CSA, cURus, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP65-115E-J | EAR99 | 8504.40.9520 | 1 | 65W | 1 | 94% | 15V | - | - | - | - | - | No | 4 kV | 60601-1; 62368-1 | 4.34 A | ||
![]() |
TMP 30115C | 71.5800 | ![]() |
5865 | 0.00000000 | Traco Power | TMP (30W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 4.41" L x 2.51" W x 1.01" H (112.0mm x 63.8mm x 25.7mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TMP 30115 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 30W | 1 | 80% | 15V | - | - | - | - | - | Yes | 3 kV | 2 A |