Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 | Current - Output 3 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
TMPW 25-115-J | 33.2900 | ![]() |
9 | 0.00000000 | Traco Power | TMPW 25-J (25W) | Box | Active | -40°C ~ 70°C (With Derating) | Household Appliances, ITE (Commercial) | 3.48" L x 1.50" W x 0.95" H (88.4mm x 38.1mm x 24.1mm) | Chassis Mount | Enclosed | - | TMPW 25 | CB, cURus | 90 ~ 305 VAC, 100 ~ 250 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TMPW25-115-J | EAR99 | 8504.40.9510 | 10 | 25W | 1 | 88% | 15V | - | - | - | - | - | No | 4 kV | 60335-1; 62368-1 | 1.666 A | |||
![]() |
TOP 60112 | - | ![]() |
5576 | 0.00000000 | Traco Power | TOP 60 (60W) | Box | Obsolete | -10°C ~ 70°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.18" H (101.6mm x 50.8mm x 30.0mm) | Chassis Mount | Open Frame | Universal Input | CB, cTUVus | 90 ~ 264 VAC, 110 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | TOP60112 | EAR99 | 8504.40.9520 | 2 | 60W | 1 | 88% | 12V | - | - | - | - | - | No | 4 kV | 5 A | |||||
![]() |
TMW 24-105 | 49.1500 | ![]() |
24 | 0.00000000 | Traco Power | TMW 24 (24W) | Box | Active | -20°C ~ 80°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 2.09" L x 2.01" W x 0.97" H (53.0mm x 51.0mm x 24.5mm) | Chassis Mount | Enclosed | - | CE, cURus, EAC, UKCA | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TMW24-105 | EAR99 | 8504.40.9510 | 10 | 20W | 1 | 85% | 5.1V | - | - | - | - | - | No | 4 kV | 60335-1; 60601-1; 62368-1 | 4 A | ||||
![]() |
TMW 24-112 | 49.1500 | ![]() |
1 | 0.00000000 | Traco Power | TMW 24 (24W) | Box | Active | -20°C ~ 80°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 2.09" L x 2.01" W x 0.97" H (53.0mm x 51.0mm x 24.5mm) | Chassis Mount | Enclosed | - | CE, cURus, EAC, UKCA | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TMW24-112 | EAR99 | 8504.40.9510 | 10 | 24W | 1 | 88% | 12V | - | - | - | - | - | No | 4 kV | 60335-1; 60601-1; 62368-1 | 2 A | ||||
![]() |
TML 100-148C | 165.4500 | ![]() |
1 | 0.00000000 | Traco Power | TML 100C (85-100W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 5.60" L x 2.48" W x 1.46" H (142.2mm x 63.0mm x 37.1mm) | Chassis Mount | Enclosed | Adjustable Output, PFC, Remote On/Off, Universal Input | TML 100 | CB, CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 1 | 101W | 1 | 93% | 48V | - | - | - | - | - | Yes | 3 kV | 2.1 A | |||||
![]() |
TML 20115C | 65.9600 | ![]() |
9 | 0.00000000 | Traco Power | TML (20W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.15" W x 1.09" H (96.0mm x 54.6mm x 27.7mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TML 20115 | CB, CE, cURus | 90 ~ 264 VAC, 100 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 20W | 1 | 84% | 15V | - | - | - | - | - | No | 3 kV | 1.34 A | |||||
![]() |
TML 20124C | 65.9600 | ![]() |
2 | 0.00000000 | Traco Power | TML (20W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.15" W x 1.09" H (96.0mm x 54.6mm x 27.7mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TML 20124 | CB, CE, cURus | 90 ~ 264 VAC, 100 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 20W | 1 | 84% | 24V | - | - | - | - | - | No | 3 kV | 840 mA | |||||
![]() |
TML 20215C | 68.2400 | ![]() |
6 | 0.00000000 | Traco Power | TML (20W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.15" W x 1.09" H (96.0mm x 54.6mm x 27.7mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TML 20215 | CB, CE, cURus | 90 ~ 264 VAC, 100 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 20W | 2 | 84% | 15V | -15V | - | - | - | - | No | 3 kV | 667 mA | 667 mA | ||||
![]() |
TML 40105C | 95.8200 | ![]() |
5 | 0.00000000 | Traco Power | TML (40W) | Box | Active | -40°C ~ 60°C (With Derating) | ITE (Commercial) | 4.41" L x 2.50" W x 1.28" H (112.0mm x 63.5mm x 32.5mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TML 40105 | CB, CE, cURus | 90 ~ 264 VAC, 100 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 40W | 1 | 84% | 5V | - | - | - | - | - | Yes | 3 kV | 8 A | |||||
![]() |
TMM 24105C | 80.4600 | ![]() |
4 | 0.00000000 | Traco Power | TMM 24 (24W) | Box | Active | -40°C ~ 80°C (With Derating) | Industrial, ITE (Commercial), Medical | 3.78" L x 2.13" W x 0.92" H (96.0mm x 54.1mm x 23.4mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TMM 24105 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 15W | 1 | 77% | 5V | - | - | - | - | - | No | 4 kV | 3 A | |||||
![]() |
TMM 24212C | 82.5500 | ![]() |
16 | 0.00000000 | Traco Power | TMM 24 (24W) | Box | Active | -40°C ~ 80°C (With Derating) | Industrial, ITE (Commercial), Medical | 3.78" L x 2.13" W x 0.92" H (96.0mm x 54.1mm x 23.4mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TMM 24212 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 24W | 2 | 84% | 12V | -12V | - | - | - | - | No | 4 kV | 1 A | 1 A | ||||
![]() |
TMM 40124C | 93.8600 | ![]() |
50 | 0.00000000 | Traco Power | TMM 40 (40W) | Box | Active | -40°C ~ 80°C (With Derating) | Industrial, ITE (Commercial), Medical | 4.41" L x 2.51" W x 1.34" H (112.0mm x 63.8mm x 34.0mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TMM 40124 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 40W | 1 | 84% | 24V | - | - | - | - | - | No | 4 kV | 1.66 A | |||||
![]() |
TMM 60112C | 110.0600 | ![]() |
2 | 0.00000000 | Traco Power | TMM 60 (60W) | Box | Active | -40°C ~ 75°C (With Derating) | Industrial, ITE (Commercial), Medical | 4.41" L x 2.57" W x 1.50" H (112.0mm x 65.3mm x 38.1mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TMM 60112 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 5 | 60W | 1 | 87% | 12V | - | - | - | - | - | No | 4 kV | 5 A | |||||
![]() |
TMM 60124C | 110.0600 | ![]() |
7575 | 0.00000000 | Traco Power | TMM 60 (60W) | Box | Active | -40°C ~ 75°C (With Derating) | Industrial, ITE (Commercial), Medical | 4.41" L x 2.57" W x 1.50" H (112.0mm x 65.3mm x 38.1mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TMM 60124 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 5 | 60W | 1 | 87% | 24V | - | - | - | - | - | No | 4 kV | 2.5 A | |||||
![]() |
TMP 15115C | 50.7100 | ![]() |
9856 | 0.00000000 | Traco Power | TMP (15W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.78" L x 2.13" W x 0.92" H (96.0mm x 54.1mm x 23.4mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TMP 15115 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 15W | 1 | 79% | 15V | - | - | - | - | - | Yes | 3 kV | 1 A | |||||
![]() |
TMP 15512C | 59.4300 | ![]() |
32 | 0.00000000 | Traco Power | TMP (15W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.78" L x 2.13" W x 0.92" H (96.0mm x 54.1mm x 23.4mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TMP 15512 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 15W | 3 | 74% | 5V | 12V | -12V | - | - | - | Yes | 3 kV | 2 A | 200 mA | 200 mA | |||
![]() |
TMP 30317C | 88.4500 | ![]() |
3 | 0.00000000 | Traco Power | TMP (30W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 4.41" L x 2.51" W x 1.01" H (112.0mm x 63.8mm x 25.7mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TMP 30317 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 29W | 3 | 71% | 5V | 3.3V | 12V | - | - | - | Yes | 3 kV | 4.5 A | 1 A | 250 mA | |||
![]() |
TMP 30522C | 88.4500 | ![]() |
4 | 0.00000000 | Traco Power | TMP (30W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 4.41" L x 2.51" W x 1.01" H (112.0mm x 63.8mm x 25.7mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TMP 30522 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 30W | 3 | 76% | 5V | 12V | -12V | - | - | - | Yes | 3 kV | 3 A | 1 A | 250 mA | |||
![]() |
TPI 150-136A-J | 83.4100 | ![]() |
2 | 0.00000000 | Traco Power | TPI 150A (150W) | Box | Active | -40°C ~ 80°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.16" H (101.6mm x 50.8mm x 29.5mm) | Chassis Mount | Open Frame | Adjustable Output, PFC, Universal Input | TPI 150 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 1 | 150W | 1 | 92% | 36V | - | - | - | - | - | No | 3 kV | 4.17 A | |||||
![]() |
TPP 150-115 | 121.4200 | ![]() |
2 | 0.00000000 | Traco Power | TPP 150 (150W) | Box | Active | -25°C ~ 80°C (With Derating) | ITE (Commercial), Medical | 4.60" L x 2.44" W x 1.94" H (116.8mm x 62.0mm x 49.3mm) | Chassis Mount | Enclosed | Adjustable Output, PFC, Universal Input | TPP 150 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 1 | 150W | 1 | 92% | 15V | - | - | - | - | - | No | 4 kV | 10 A | |||||
![]() |
TPP 150-124 | 121.4200 | ![]() |
20 | 0.00000000 | Traco Power | TPP 150 (150W) | Box | Active | -25°C ~ 80°C (With Derating) | ITE (Commercial), Medical | 4.60" L x 2.44" W x 1.94" H (116.8mm x 62.0mm x 49.3mm) | Chassis Mount | Enclosed | Adjustable Output, PFC, Universal Input | TPP 150 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 1 | 150W | 1 | 92% | 24V | - | - | - | - | - | No | 4 kV | 6.25 A | |||||
![]() |
TPP 150-128 | 121.4200 | ![]() |
4286 | 0.00000000 | Traco Power | TPP 150 (150W) | Box | Active | -25°C ~ 80°C (With Derating) | ITE (Commercial), Medical | 4.60" L x 2.44" W x 1.94" H (116.8mm x 62.0mm x 49.3mm) | Chassis Mount | Enclosed | Adjustable Output, PFC, Universal Input | TPP 150 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 1 | 150W | 1 | 92% | 28V | - | - | - | - | - | No | 4 kV | 5.36 A | |||||
![]() |
TPP 40-221 | 90.1000 | ![]() |
9957 | 0.00000000 | Traco Power | TPP 40 (40W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 4.03" L x 2.38" W x 1.36" H (102.4mm x 60.5mm x 34.5mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TPP 40 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 60W | 2 | 89% | 12V | 5V | - | - | - | - | No | 4 kV | 3.34 A | 4 A | ||||
![]() |
TPP 65-105 | 73.6100 | ![]() |
6949 | 0.00000000 | Traco Power | TPP 65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.53" L x 2.38" W x 1.31" H (89.7mm x 60.5mm x 33.3mm) | Chassis Mount | Enclosed | Universal Input | TPP 65 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 50W | 1 | 90% | 5V | - | - | - | - | - | No | 4 kV | 10 A | |||||
![]() |
TXH 480-112 | - | ![]() |
4708 | 0.00000000 | Traco Power | TXH 480 (480W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 7.98" L x 4.19" W x 1.77" H (202.8mm x 106.5mm x 45.0mm) | Chassis Mount | Enclosed | Adjustable Output, Remote On/Off, Universal Input | CB, CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9530 | 10 | 480W | 1 | 88% | 12V | - | - | - | - | - | No | 3 kV | 40 A | ||||||
![]() |
TXH 600-112 | - | ![]() |
2466 | 0.00000000 | Traco Power | TXH 600 (600W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 9.00" L x 4.13" W x 1.73" H (228.5mm x 105.0mm x 44.0mm) | Chassis Mount | Enclosed | Adjustable Output, PFC, Remote On/Off, Universal Input | CB, CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 10 | 540W | 1 | 90% | 12V | - | - | - | - | - | Yes | 3 kV | 45 A | ||||||
![]() |
TXL 015-15S | - | ![]() |
7052 | 0.00000000 | Traco Power | TXL 05 (15W) | Box | Obsolete | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 2.44" L x 2.01" W x 1.10" H (62.0mm x 51.1mm x 27.9mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | CE, cURus | 85 ~ 264 VAC, 120 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 15W | 1 | 84% | 15V | - | - | - | - | - | Yes | 3 kV | 1 A | ||||||
![]() |
TXL 100-15S | - | ![]() |
4712 | 0.00000000 | Traco Power | TXL 100 (100W) | Box | Obsolete | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 7.80" L x 3.74" W x 1.50" H (198.1mm x 95.0mm x 38.1mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | CE, cURus | 85 ~ 264 VAC, 120 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 2 | 105W | 1 | 84% | 15V | - | - | - | - | - | Yes | 3 kV | 7 A | ||||||
![]() |
TXL 100-48S | - | ![]() |
7789 | 0.00000000 | Traco Power | TXL 100 (100W) | Box | Obsolete | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 7.80" L x 3.74" W x 1.50" H (198.1mm x 95.0mm x 38.1mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | CE, cURus | 85 ~ 264 VAC, 120 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 2 | 110W | 1 | 84% | 48V | - | - | - | - | - | Yes | 3 kV | 2.3 A | ||||||
![]() |
TXL 230-12S | - | ![]() |
5174 | 0.00000000 | Traco Power | TXL 230 (230W) | Box | Obsolete | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 7.80" L x 3.90" W x 1.77" H (198.1mm x 99.1mm x 45.0mm) | Chassis Mount | Enclosed | Adjustable Output, Remote On/Off, Remote Sense, Universal Input | CE, cURus | 85 ~ 264 VAC, 120 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9530 | 2 | 230W | 1 | 84% | 12V | - | - | - | - | - | Yes | 3 kV | 19.2 A |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse