Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 | Current - Output 3 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
TOP 200-115 | 151.7200 | ![]() |
10 | 0.00000000 | Traco Power | TOP 200 (200W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 5.00" L x 3.00" W x 1.34" H (127.0mm x 76.2mm x 34.0mm) | Chassis Mount | Open Frame | Adjustable Output, Remote On/Off, Universal Input | TOP 200 | CB, CE, cCSAus, GS, SIQ | 85 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9530 | 10 | 195W | 1 | 93% | 15V | - | - | - | - | - | - | 3 kV | 13 A | |||||
![]() |
TXL 060-05S | - | ![]() |
8769 | 0.00000000 | Traco Power | TXL 060 (60W) | Box | Obsolete | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 6.26" L x 3.74" W x 1.50" H (159.0mm x 95.0mm x 38.1mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TXL 060 | CE, cURus | 85 ~ 264 VAC, 120 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 5 | 60W | 1 | 84% | 5V | - | - | - | - | - | Yes | 3 kV | 12 A | |||||
![]() |
TMP 15252C | 59.4300 | ![]() |
8 | 0.00000000 | Traco Power | TMP (15W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.78" L x 2.13" W x 0.92" H (96.0mm x 54.1mm x 23.4mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TMP 15252 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 15W | 2 | 72% | 5V | 12V | - | - | - | - | Yes | 3 kV | 1.5 A | 625 mA | ||||
![]() |
TXM 025-115 | 32.9500 | ![]() |
5 | 0.00000000 | Traco Power | TXM 025 (25W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.11" L x 2.01" W x 1.13" H (79.0mm x 51.0mm x 28.8mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TXM 025 | CE, cURus | 90 ~ 264 VAC, 127 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 24W | 1 | 83% | 15V | - | - | - | - | - | No | 3 kV | 1.6 A | |||||
![]() |
TMT 15112C | - | ![]() |
2755 | 0.00000000 | Traco Power | TMT (15W) | Box | Obsolete | -25°C ~ 50°C (With Derating) | Industrial, ITE (Commercial), Medical | 3.03" L x 1.77" W x 1.04" H (77.0mm x 45.0mm x 26.4mm) | Chassis Mount | Enclosed | Universal Input | TMT 15112 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 85 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | TMT15112C | EAR99 | 8504.40.9510 | 5 | 15W | 1 | 83% | 12V | - | - | - | - | - | - | 4 kV | 1.25 A | ||||
![]() |
TMT 30212C | - | ![]() |
9263 | 0.00000000 | Traco Power | TMT (30W) | Box | Obsolete | -25°C ~ 50°C (With Derating) | Industrial, ITE (Commercial), Medical | 3.78" L x 2.01" W x 1.16" H (96.0mm x 51.0mm x 29.5mm) | Chassis Mount | Enclosed | Universal Input | TMT 30212 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 85 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | TMT30212C | EAR99 | 8504.40.9510 | 5 | 30W | 2 | 83% | 12V | -12V | - | - | - | - | - | 4 kV | 1.25 A | 1.25 A | |||
![]() |
TMT 50105C | - | ![]() |
7256 | 0.00000000 | Traco Power | TMT (50W) | Box | Obsolete | -25°C ~ 50°C (With Derating) | Industrial, ITE (Commercial), Medical | 4.33" L x 2.52" W x 1.32" H (110.0mm x 64.0mm x 33.5mm) | Chassis Mount | Enclosed | Universal Input | TMT 50105 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 85 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | TMT50105C | EAR99 | 8504.40.9510 | 5 | 45W | 1 | 83% | 5V | - | - | - | - | - | - | 4 kV | 9 A | ||||
![]() |
TMT 50112C | - | ![]() |
7589 | 0.00000000 | Traco Power | TMT (50W) | Box | Obsolete | -25°C ~ 50°C (With Derating) | Industrial, ITE (Commercial), Medical | 4.33" L x 2.52" W x 1.32" H (110.0mm x 64.0mm x 33.5mm) | Chassis Mount | Enclosed | Universal Input | TMT 50112 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 85 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | TMT50112C | EAR99 | 8504.40.9510 | 5 | 50W | 1 | 83% | 12V | - | - | - | - | - | - | 4 kV | 4.2 A | ||||
![]() |
TMT 50124C | - | ![]() |
2234 | 0.00000000 | Traco Power | TMT (50W) | Box | Obsolete | -25°C ~ 50°C (With Derating) | Industrial, ITE (Commercial), Medical | 4.33" L x 2.52" W x 1.32" H (110.0mm x 64.0mm x 33.5mm) | Chassis Mount | Enclosed | Universal Input | TMT 50124 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 85 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | TMT50124C | EAR99 | 8504.40.9510 | 5 | 55W | 1 | 83% | 24V | - | - | - | - | - | - | 4 kV | 2.3 A | ||||
![]() |
TOP 200-112C | - | ![]() |
4594 | 0.00000000 | Traco Power | TOP 200 (200W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 5.00" L x 3.00" W x 1.34" H (127.0mm x 76.2mm x 34.0mm) | Chassis Mount | Open Frame | Universal Input | TOP 200 | CB, CE, CSAus, GS, SIQ | 85 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | TOP200-112C | EAR99 | 8504.40.9530 | 10 | 192W | 1 | 93% | 12V | - | - | - | - | - | - | 3 kV | 16 A | ||||
![]() |
TOP 60522 | - | ![]() |
2127 | 0.00000000 | Traco Power | TOP 60 (60W) | Box | Obsolete | -10°C ~ 70°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.18" H (101.6mm x 50.8mm x 30.0mm) | Chassis Mount | Open Frame | Universal Input | CB, cTUVus | 90 ~ 264 VAC, 110 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | TOP60522 | EAR99 | 8504.40.9520 | 2 | 72W | 3 | 88% | 5V | 12V | -12V | - | - | - | Yes | 4 kV | 6 A | 3 A | 500 mA | |||
![]() |
TOP 60533 | - | ![]() |
8527 | 0.00000000 | Traco Power | TOP 60 (60W) | Box | Obsolete | -10°C ~ 70°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.18" H (101.6mm x 50.8mm x 30.0mm) | Chassis Mount | Open Frame | Universal Input | CB, cTUVus | 90 ~ 264 VAC, 110 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | TOP60533 | EAR99 | 8504.40.9520 | 2 | 74W | 3 | 88% | 5V | 15V | -15V | - | - | - | Yes | 4 kV | 6 A | 2.4 A | 500 mA | |||
![]() |
TPP 65-124 | 66.1600 | ![]() |
266 | 0.00000000 | Traco Power | TPP 65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.53" L x 2.38" W x 1.31" H (89.7mm x 60.5mm x 33.3mm) | Chassis Mount | Enclosed | Universal Input | TPP 65 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1005 | EAR99 | 8504.40.9520 | 1 | 65W | 1 | 93.5% | 24V | - | - | - | - | - | No | 4 kV | 2.71 A | ||||
![]() |
TPP 30-103A-J | 50.1400 | ![]() |
3879 | 0.00000000 | Traco Power | TPP 30A-J (30W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 3.34" L x 1.36" W x 0.77" H (84.8mm x 34.5mm x 19.6mm) | Chassis Mount | Open Frame | Adjustable Output, Universal Input | TPP 30 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1078 | EAR99 | 8504.40.9510 | 1 | 20W | 1 | 84% | 3.3V | - | - | - | - | - | No | 4 kV | 6 A | ||||
![]() |
TPP 40-115 | 63.0900 | ![]() |
6 | 0.00000000 | Traco Power | TPP 40 (40W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.53" L x 2.38" W x 1.31" H (89.7mm x 60.5mm x 33.3mm) | Chassis Mount | Enclosed | Universal Input | TPP 40 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1082 | EAR99 | 8504.40.9510 | 1 | 40W | 1 | 92% | 15V | - | - | - | - | - | No | 4 kV | 2.67 A | ||||
![]() |
TOP 200-112 | 151.7200 | ![]() |
8298 | 0.00000000 | Traco Power | TOP 200 (200W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 5.00" L x 3.00" W x 1.34" H (127.0mm x 76.2mm x 34.0mm) | Chassis Mount | Open Frame | Adjustable Output, Remote On/Off, Universal Input | TOP 200 | CB, CE, cCSAus, GS, SIQ | 85 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1104 | EAR99 | 8504.40.9530 | 10 | 192W | 1 | 93% | 12V | - | - | - | - | - | - | 3 kV | 16 A | ||||
![]() |
TPP 150-148 | 119.4800 | ![]() |
2051 | 0.00000000 | Traco Power | TPP 150 (150W) | Box | Active | -25°C ~ 80°C (With Derating) | ITE (Commercial), Medical | 4.60" L x 2.44" W x 1.94" H (116.8mm x 62.0mm x 49.3mm) | Chassis Mount | Enclosed | Adjustable Output, PFC, Universal Input | TPP 150 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1184 | EAR99 | 8504.40.9520 | 1 | 150W | 1 | 92% | 48V | - | - | - | - | - | No | 4 kV | 3.13 A | ||||
![]() |
TPP 30-105A-J | 50.1400 | ![]() |
8163 | 0.00000000 | Traco Power | TPP 30A-J (30W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 3.34" L x 1.36" W x 0.77" H (84.8mm x 34.5mm x 19.6mm) | Chassis Mount | Open Frame | Adjustable Output, Universal Input | TPP 30 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1189 | EAR99 | 8504.40.9510 | 1 | 30W | 1 | 87% | 5V | - | - | - | - | - | No | 4 kV | 6 A | ||||
![]() |
TPP 65-112 | 66.1600 | ![]() |
80 | 0.00000000 | Traco Power | TPP 65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.53" L x 2.38" W x 1.31" H (89.7mm x 60.5mm x 33.3mm) | Chassis Mount | Enclosed | Universal Input | TPP 65 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1198 | EAR99 | 8504.40.9520 | 1 | 65W | 1 | 92.5% | 12V | - | - | - | - | - | No | 4 kV | 5.42 A | ||||
![]() |
TXH 060-115 | 61.5300 | ![]() |
10 | 0.00000000 | Traco Power | TXH 060 (50-60W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial) | 3.00" L x 1.99" W x 1.50" H (76.3mm x 50.6mm x 38.0mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TXH 060 | CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1206 | EAR99 | 8504.40.9520 | 10 | 60W | 1 | 87% | 15V | - | - | - | - | - | No | 4.242 kV | 4 A | ||||
![]() |
TXH 240-112 | 134.5500 | ![]() |
9 | 0.00000000 | Traco Power | TXH 240 (240W) | Box | Active | -10°C ~ 70°C (With Derating) | ITE (Commercial) | 5.91" L x 4.17" W x 1.38" H (150.1mm x 105.9mm x 35.1mm) | Chassis Mount | Enclosed | Adjustable Output, Remote On/Off, Universal Input | TXH 240 | CB, CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1210 | EAR99 | 8504.40.9530 | 10 | 240W | 1 | 90% | 12V | - | - | - | - | - | No | 4 kV | 20 A | ||||
![]() |
TXL 015-24S | - | ![]() |
2450 | 0.00000000 | Traco Power | TXL 05 (15W) | Box | Obsolete | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 2.44" L x 2.01" W x 1.10" H (62.0mm x 51.1mm x 27.9mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | CE, cURus | 85 ~ 264 VAC, 120 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1212 | EAR99 | 8504.40.9510 | 5 | 15W | 1 | 84% | 24V | - | - | - | - | - | - | 3 kV | 630 mA | |||||
![]() |
TXL 060-0534TI | - | ![]() |
9246 | 0.00000000 | Traco Power | TXL 060 (60W) | Box | Obsolete | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 6.26" L x 3.74" W x 1.50" H (159.0mm x 95.0mm x 38.1mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | CE, cURus | 85 ~ 264 VAC, 120 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1218 | EAR99 | 8504.40.9520 | 5 | 60W | 3 | 84% | 5V | 12V | 24V | - | - | - | - | 3 kV | 6 A | 1.5 A | 1.2 A | |||
![]() |
TOP 200-148 | 136.0100 | ![]() |
4133 | 0.00000000 | Traco Power | TOP 200 (200W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 5.00" L x 3.00" W x 1.34" H (127.0mm x 76.2mm x 34.0mm) | Chassis Mount | Open Frame | Adjustable Output, Remote On/Off, Universal Input | TOP 200 | CB, CE, cCSAus, GS, SIQ | 85 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1225 | EAR99 | 8504.40.9530 | 10 | 202W | 1 | 95% | 48V | - | - | - | - | - | - | 3 kV | 4.2 A | ||||
![]() |
TEX 120-124 | 364.9800 | ![]() |
29 | 0.00000000 | Traco Power | TEX (120W) | Box | Active | -40°C ~ 85°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial), Laboratory | 6.85" L x 3.66" W x 2.20" H (174.0mm x 93.0mm x 55.9mm) | Chassis Mount | Enclosed | Adjustable Output, IP67, Universal Input | TEX 120 | CB, CE, cCSAus, cULus, SIQ | 85 ~ 264 VAC, 85 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1247 | EAR99 | 8504.40.9520 | 10 | 120W | 1 | - | 24V | - | - | - | - | - | - | 5 A | |||||
![]() |
TIW 12-112 | 50.7800 | ![]() |
6005 | 0.00000000 | Traco Power | TIW (12W) | Box | Active | -25°C ~ 50°C | Household Appliances, ITE (Commercial) | 2.17" L x 0.93" W x 1.89" H (55.0mm x 23.6mm x 48.0mm) | Chassis Mount | Enclosed | IP67, Universal Input | TIW 12 | CB, CE, cCSAus | 93 ~ 132 VAC, 187 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1248 | EAR99 | 8504.40.9510 | 10 | 12W | 1 | 80% | 12V | - | - | - | - | - | - | 1 A | |||||
![]() |
TXM 015-112 | 26.6000 | ![]() |
24 | 0.00000000 | Traco Power | TXM 015 (15W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.11" L x 2.01" W x 1.13" H (79.0mm x 51.0mm x 28.8mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TXM 015 | CE, cURus | 85 ~ 264 VAC, 127 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1261 | EAR99 | 8504.40.9510 | 5 | 16W | 1 | 82% | 12V | - | - | - | - | - | - | 3 kV | 60950-1; 62368-1 | 1.3 A | |||
![]() |
TML 40112C | 95.8200 | ![]() |
8762 | 0.00000000 | Traco Power | TML (40W) | Box | Active | -40°C ~ 60°C (With Derating) | ITE (Commercial) | 4.41" L x 2.50" W x 1.28" H (112.0mm x 63.5mm x 32.5mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TML 40112 | CB, CE, cURus | 90 ~ 264 VAC, 100 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1283 | EAR99 | 8504.40.9580 | 5 | 40W | 1 | 84% | 12V | - | - | - | - | - | Yes | 3 kV | 3.333 A | ||||
![]() |
TMM 24112C | 80.4600 | ![]() |
43 | 0.00000000 | Traco Power | TMM 24 (24W) | Box | Active | -40°C ~ 80°C (With Derating) | Industrial, ITE (Commercial), Medical | 3.78" L x 2.13" W x 0.92" H (96.0mm x 54.1mm x 23.4mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TMM 24112 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1294 | EAR99 | 8504.40.9510 | 5 | 24W | 1 | 83% | 12V | - | - | - | - | - | No | 4 kV | 2 A | ||||
![]() |
TMP 15515C | 59.4300 | ![]() |
3 | 0.00000000 | Traco Power | TMP (15W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.78" L x 2.13" W x 0.92" H (96.0mm x 54.1mm x 23.4mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TMP 15515 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1306 | EAR99 | 8504.40.9510 | 5 | 15W | 3 | 74% | 5V | 15V | -15V | - | - | - | Yes | 3 kV | 2 A | 150 mA | 150 mA |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse