Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Package / Case | Type | Features | Base Product Number | Approval Agency | Voltage - Input | Weight | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Current - Output (Max) | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Standard Number | Line Regulation | Load Regulation |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
TML 15124 | - | ![]() |
9619 | 0.00000000 | Traco Power | TML | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 2.91" L x 2.13" W x 0.87" H (74.0mm x 54.0mm x 22.0mm) | Through Hole | 8-DIP Module, 5 Leads | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 85 ~ 370 VDC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TML15124 | EAR99 | 8504.40.9510 | 10 | 15 W | 1 | 625mA | 80% | 24V | - | - | - | - | - | ||||
![]() |
TMP 30115 | 60.8900 | ![]() |
7296 | 0.00000000 | Traco Power | TMP (30W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.50" L x 2.50" W x 0.85" H (88.9mm x 63.5mm x 21.7mm) | Through Hole | 7-DIP Module, 5 Leads | Enclosed | Universal Input | TMP 30 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 30 W | 1 | 2A | 80% | 15V | - | - | - | - | - | ||||
![]() |
TMG 30115 | 60.6300 | ![]() |
10 | 0.00000000 | Traco Power | TMG (30W) | Box | Active | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 2.52" L x 1.77" W x 0.93" H (64.0mm x 45.0mm x 23.5mm) | Through Hole | 5-DIP Module, 4 Leads | Enclosed | Universal Input | TMG 30 | CE, cURus | 90 ~ 305 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 30 W | 1 | 2A | 86% | 15V | - | - | - | - | - | ||||
![]() |
TMG 30105 | 60.6300 | ![]() |
10 | 0.00000000 | Traco Power | TMG (30W) | Box | Active | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 2.52" L x 1.77" W x 0.93" H (64.0mm x 45.0mm x 23.5mm) | Through Hole | 5-DIP Module, 4 Leads | Enclosed | Universal Input | TMG 30 | CE, cURus | 90 ~ 305 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 25 W | 1 | 5A | 84% | 5V | - | - | - | - | - | ||||
![]() |
TMT 10115 | - | ![]() |
5825 | 0.00000000 | Traco Power | TMT (10W) | Box | Obsolete | -25°C ~ 50°C (With Derating) | ITE (Commercial), Medical | 2.00" L x 1.30" W x 0.85" H (50.8mm x 33.0mm x 21.6mm) | Through Hole | 4-DIP Module | Enclosed | Universal Input | TMT 10 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 85 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | TMT10115 | EAR99 | 8504.40.9510 | 5 | 10 W | 1 | 670mA | 83% | 15V | - | - | - | - | 50mV | |||
![]() |
TMLM 04103 | 18.6000 | ![]() |
8 | 0.00000000 | Traco Power | TMLM (4W) | Box | Active | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 1.44" L x 1.06" W x 0.67" H (36.5mm x 27.0mm x 17.1mm) | Through Hole | 7-DIP Module | Enclosed | Universal Input | TMLM 04 | CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1156 | EAR99 | 8504.40.9510 | 10 | 4 W | 1 | 1.2A | 67% | 3.3V | - | - | - | 0.3% | ±1% | |||
![]() |
TOM 12212 | - | ![]() |
4447 | 0.00000000 | Traco Power | TOM (12W) | Box | Obsolete | -10°C ~ 70°C (With Derating) | ITE (Commercial) | 2.56" L x 1.26" W x 0.91" H (65.0mm x 32.0mm x 23.0mm) | Through Hole | 6-DIP Module | Open Frame | Universal Input | CE, cURus | 85 ~ 264 VAC | - | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | TOM12212 | EAR99 | 8504.40.9510 | 10 | 12 W | 2 | 500mA, 500mA | 80% | 12V | - | - | - | - | 50mV | ||||
![]() |
TML 10215 | - | ![]() |
1098 | 0.00000000 | Traco Power | TML | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 2.52" L x 1.77" W x 0.81" H (64.0mm x 45.0mm x 20.5mm) | Through Hole | 6-DIP Module | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 85 ~ 370 VDC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TML10215 | EAR99 | 8504.40.9510 | 10 | 9 W | 2 | 300mA, 300mA | 80% | 15V | - | - | - | - | - | ||||
![]() |
TMP 30316 | 75.7580 | ![]() |
3212 | 0.00000000 | Traco Power | TMP (30W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.50" L x 2.50" W x 0.85" H (88.9mm x 63.5mm x 21.7mm) | Through Hole | 7-DIP Module | Enclosed | Universal Input | TMP 30 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 24 W | 3 | 4A, 1.5A, 250mA | 71% | 3.3V | - | - | - | - | - | ||||
![]() |
TML 10112 | - | ![]() |
1030 | 0.00000000 | Traco Power | TML | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 2.52" L x 1.77" W x 0.81" H (64.0mm x 45.0mm x 20.5mm) | Through Hole | 6-DIP Module | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 85 ~ 370 VDC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TML10112 | EAR99 | 8504.40.9510 | 10 | 10 W | 1 | 833mA | 80% | 12V | - | - | - | - | - | ||||
![]() |
TMW 24-124P | 51.1400 | ![]() |
18 | 0.00000000 | Traco Power | TMW 24P (24W) | Box | Active | -20°C ~ 80°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 2.09" L x 2.01" W x 0.96" H (53.0mm x 51.0mm x 24.5mm) | Through Hole | 4-DIP Module | Enclosed | - | CE, cURus, EAC, UKCA | 85 ~ 264 VAC | - | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TMW24-124P | EAR99 | 8504.40.9510 | 10 | 24 W | 1 | 1A | 90% | 24V | - | - | - | 60335-1; 60601-1; 62368-1 | - | ±1% | ||
![]() |
TML 05105 | - | ![]() |
2604 | 0.00000000 | Traco Power | TML | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 2.17" L x 1.77" W x 0.81" H (55.0mm x 45.0mm x 20.5mm) | Through Hole | 6-DIP Module | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 85 ~ 370 VDC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TML05105 | EAR99 | 8504.40.9510 | 10 | 5 W | 1 | 1A | 80% | 5V | - | - | - | - | - | ||||
![]() |
TPP 65-136E-D | 71.5600 | ![]() |
1 | 0.00000000 | Traco Power | TPP 65E-D (65W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 3.20" L x 2.20" W x 1.20" H (81.3mm x 55.9mm x 30.5mm) | Through Hole | 6-DIP Module, 5 Leads | Enclosed | DC Input Capable, Universal Input | CB, CE, CSA, cURus, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | - | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP65-136E-D | EAR99 | 8504.40.9520 | 1 | 65 W | 1 | 1.81A | 93% | 36V | - | - | - | 60601-1; 62368-1 | 0.2% | 0.5% | ||
![]() |
TMP 10105 | - | ![]() |
1112 | 0.00000000 | Traco Power | TMP (10W) | Box | Obsolete | -25°C ~ 50°C | ITE (Commercial) | 2.52" L x 1.77" W x 0.76" H (64.0mm x 45.0mm x 19.2mm) | Through Hole | 5-DIP Module | Enclosed | Universal Input | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 10 W | 1 | 2A | 73% | 5V | - | - | - | - | - | |||||
![]() |
TMLM 05103 | - | ![]() |
9233 | 0.00000000 | Traco Power | TMLM (5W) | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 2.00" L x 1.00" W x 0.60" H (50.8mm x 25.4mm x 15.2mm) | Through Hole | 4-DIP Module | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 4.1 W | 1 | 1.25A | 68% | 3.3V | - | - | - | - | - | |||||
![]() |
TMPM 04215 | - | ![]() |
9451 | 0.00000000 | Traco Power | TMPM (4W) | Box | Obsolete | -25°C ~ 60°C | ITE (Commercial) | 1.44" L x 1.06" W x 0.67" H (36.5mm x 27.0mm x 17.1mm) | Through Hole | 7-DIP Module | Enclosed | Universal Input | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1172 | EAR99 | 8504.40.9510 | 10 | 4 W | 2 | 133mA, 133mA | 77% | 15V | - | - | - | 1%, 3% | 1% | ||||
![]() |
TMPS 05-148 | 19.1400 | ![]() |
34 | 0.00000000 | Traco Power | TMPS 05 (5W) | Box | Active | -25°C ~ 70°C (With Derating) | Household Appliances, ITE (Commercial) | 1.00" L x 1.00" W x 0.64" H (25.4mm x 25.4mm x 16.3mm) | Through Hole | 5-DIP Module | Enclosed | Universal Input | TMPS 05 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 5 W | 1 | 104mA | 85% | 48V | - | - | - | - | - | ||||
![]() |
TPP 30-103-D | 68.0400 | ![]() |
5571 | 0.00000000 | Traco Power | TPP 30-D (30W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 2.89" L x 1.50" W x 1.01" H (73.3mm x 38.1mm x 25.6mm) | Through Hole | 5-DIP Module | Enclosed | Adjustable Output, Universal Input | TPP 30 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-2864 | EAR99 | 8504.40.9510 | 1 | 20 W | 1 | 6A | 84% | 3.3V | - | - | - | - | 0.70% | |||
![]() |
TMLM 04115 | 18.5800 | ![]() |
5233 | 0.00000000 | Traco Power | TMLM (4W) | Box | Active | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 1.44" L x 1.06" W x 0.67" H (36.5mm x 27.0mm x 17.1mm) | Through Hole | 7-DIP Module | Enclosed | Universal Input | TMLM 04 | CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1286 | EAR99 | 8504.40.9510 | 10 | 4 W | 1 | 267mA | 74% | 15V | - | - | - | 0.3% | ±0.5% | |||
![]() |
TMP 07124 | 31.1500 | ![]() |
50 | 0.00000000 | Traco Power | TMP (7W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 2.00" L x 1.00" W x 0.77" H (50.8mm x 25.4mm x 19.5mm) | Through Hole | 4-DIP Module | Enclosed | Universal Input | TMP 07 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1298 | EAR99 | 8504.40.9510 | 10 | 7 W | 1 | 291mA | 78% | 24V | - | - | - | 1% | ±1% | |||
![]() |
TMG 15124 | 41.2300 | ![]() |
8822 | 0.00000000 | Traco Power | TMG (15W) | Box | Active | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 1.62" L x 1.07" W x 0.75" H (41.2mm x 27.2mm x 19.1mm) | Through Hole | 4-DIP Module | Enclosed | Universal Input | TMG 15 | CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1152 | EAR99 | 8504.40.9510 | 10 | 15 W | 1 | 625mA | 85% | 24V | - | - | - | 0.5% | ±1% | |||
![]() |
TML 30105 | - | ![]() |
2951 | 0.00000000 | Traco Power | TML | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 3.50" L x 2.50" W x 0.98" H (88.9mm x 63.5mm x 25.0mm) | Through Hole | 7-DIP Module, 5 Leads | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 100 ~ 370 VDC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TML30105 | EAR99 | 8504.40.9510 | 10 | 30 W | 1 | 6A | 80% | 5V | - | - | - | - | - | ||||
![]() |
TPP 30-112A-D | 44.5600 | ![]() |
1507 | 0.00000000 | Traco Power | TPP 30A-D (30W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 2.74" L x 1.36" W x 0.95" H (69.7mm x 34.6mm x 24.1mm) | Through Hole | 5-DIP Module | Open Frame | Adjustable Output, Universal Input | TPP 30 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-2859 | EAR99 | 8504.40.9510 | 1 | 30 W | 1 | 2.5A | 90.5% | 12V | - | - | - | - | 0.5% | |||
![]() |
TML 30215 | - | ![]() |
6739 | 0.00000000 | Traco Power | TML | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 3.50" L x 2.50" W x 0.98" H (88.9mm x 63.5mm x 25.0mm) | Through Hole | 7-DIP Module, 5 Leads | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 100 ~ 370 VDC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TML30215 | EAR99 | 8504.40.9510 | 10 | 30 W | 2 | 1A, 1A | 80% | 15V | -15V | - | - | - | - | ||||
![]() |
TPP 30-148A-D | 42.7500 | ![]() |
3 | 0.00000000 | Traco Power | TPP 30A-D (30W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 2.74" L x 1.36" W x 0.95" H (69.7mm x 34.6mm x 24.1mm) | Through Hole | 5-DIP Module | Open Frame | Adjustable Output, Universal Input | TPP 30 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-2863 | EAR99 | 8504.40.9510 | 1 | 30 W | 1 | 630mA | 91.5% | 48V | - | - | - | - | 0.5% | |||
![]() |
TMF 10115 | 35.9800 | ![]() |
5631 | 0.00000000 | Traco Power | TMF (10W) | Box | Active | -25°C ~ 70°C (With Derating) | Medical | 2.06" L x 1.06" W x 0.75" H (52.2mm x 26.8mm x 19.0mm) | Through Hole | 4-DIP Module | Enclosed | Universal Input | TMF 10 | - | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 10 W | 1 | 666mA | 84% | 15V | - | - | - | - | - | ||||
![]() |
TMP 30215 | 63.6100 | ![]() |
131 | 0.00000000 | Traco Power | TMP (30W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.50" L x 2.50" W x 0.85" H (88.9mm x 63.5mm x 21.7mm) | Through Hole | 7-DIP Module, 5 Leads | Enclosed | Universal Input | TMP 30 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1168 | EAR99 | 8504.40.9510 | 5 | 30 W | 2 | 1A, 1A | 80% | 15V | - | - | - | 1%, 3% | ±1% | |||
![]() |
TMF 30112 | 54.9100 | ![]() |
1 | 0.00000000 | Traco Power | TMF (30W) | Box | Active | -25°C ~ 70°C (With Derating) | Medical | 2.52" L x 1.80" W x 0.93" H (64.1mm x 45.6mm x 23.5mm) | Through Hole | 5-DIP Module, 4 Leads | Enclosed | Universal Input | TMF 30 | - | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 30 W | 1 | 2.5A | 88% | 12V | - | - | - | - | - | ||||
![]() |
TMLM 05105 | - | ![]() |
3607 | 0.00000000 | Traco Power | TMLM (5W) | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 2.00" L x 1.00" W x 0.60" H (50.8mm x 25.4mm x 15.2mm) | Through Hole | 4-DIP Module | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1288 | EAR99 | 8504.40.9510 | 10 | 5 W | 1 | 1A | 71% | 5V | - | - | - | 0.3% | ±0.5% | ||||
![]() |
TMF 10105 | 35.9800 | ![]() |
4 | 0.00000000 | Traco Power | TMF (10W) | Box | Active | -25°C ~ 70°C (With Derating) | Medical | 2.06" L x 1.06" W x 0.75" H (52.2mm x 26.8mm x 19.0mm) | Through Hole | 4-DIP Module | Enclosed | Universal Input | TMF 10 | - | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 10 W | 1 | 2A | 79% | 5V | - | - | - | - | - |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse