Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Package / Case | Type | Features | Base Product Number | Approval Agency | Voltage - Input | Weight | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Current - Output (Max) | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Standard Number | Line Regulation | Load Regulation |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
TML 30103 | - | ![]() |
7582 | 0.00000000 | Traco Power | TML | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 3.50" L x 2.50" W x 0.98" H (88.9mm x 63.5mm x 25.0mm) | Through Hole | 7-DIP Module, 5 Leads | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 100 ~ 370 VDC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TML30103 | EAR99 | 8504.40.9510 | 10 | 20 W | 1 | 6A | 80% | 3.3V | - | - | - | - | - | ||||
![]() |
TMW 36-124P | 58.2300 | ![]() |
10 | 0.00000000 | Traco Power | TMW 36P (36W) | Box | Active | -20°C ~ 80°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 2.09" L x 2.01" W x 1.34" H (53.0mm x 51.0mm x 34.0mm) | Surface Mount | 4-DIP Module | Enclosed | - | CE, cURus, EAC, UKCA | 85 ~ 264 VAC | - | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TMW36-124P | EAR99 | 8504.40.9510 | 10 | 36 W | 1 | 1.5A | 88% | 24V | - | - | - | 60335-1; 60601-1; 62368-1 | - | ±1% | ||
![]() |
TMG 07112 | 32.6500 | ![]() |
56 | 0.00000000 | Traco Power | TMG (7W) | Box | Active | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 1.08" L x 1.08" W x 0.74" H (27.4mm x 27.4mm x 18.7mm) | Through Hole | 4-DIP Module | Enclosed | Universal Input | TMG 07 | CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 7 W | 1 | 583mA | 80% | 12V | - | - | - | - | - | ||||
![]() |
TMG 50115 | 81.6200 | ![]() |
10 | 0.00000000 | Traco Power | TMG (50W) | Box | Active | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 2.92" L x 2.13" W x 0.86" H (74.1mm x 54.1mm x 21.8mm) | Through Hole | 4-DIP Module | Enclosed | Universal Input | TMG 50 | CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 50 W | 1 | 3.333A | 87% | 15V | - | - | - | - | - | ||||
![]() |
TMM 60112 | 100.3500 | ![]() |
4 | 0.00000000 | Traco Power | TMM 60 (60W) | Box | Active | -40°C ~ 75°C (With Derating) | Industrial, ITE (Commercial), Medical | 3.50" L x 2.66" W x 1.35" H (88.9mm x 67.5mm x 34.2mm) | Through Hole | 6-DIP Module, 4 Leads | Enclosed | Universal Input | TMM 60 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 5 | 60 W | 1 | 5A | 87% | 12V | - | - | - | - | - | ||||
![]() |
TMP 10103 | - | ![]() |
5052 | 0.00000000 | Traco Power | TMP (10W) | Box | Obsolete | -25°C ~ 50°C | ITE (Commercial) | 2.52" L x 1.77" W x 0.76" H (64.0mm x 45.0mm x 19.2mm) | Through Hole | 5-DIP Module | Enclosed | Universal Input | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 6.6 W | 1 | 2A | 70% | 3.3V | - | - | - | - | - | |||||
![]() |
TMP 15252 | 48.9600 | ![]() |
5 | 0.00000000 | Traco Power | TMP (15W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 2.91" L x 2.13" W x 0.77" H (74.0mm x 54.0mm x 19.5mm) | Through Hole | 7-DIP Module, 6 Leads | Enclosed | Universal Input | TMP 15 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 15 W | 2 | 1.5A, 625mA | 72% | 5V | - | - | - | - | - | ||||
![]() |
TMP 30112 | 60.8900 | ![]() |
1198 | 0.00000000 | Traco Power | TMP (30W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.50" L x 2.50" W x 0.85" H (88.9mm x 63.5mm x 21.7mm) | Through Hole | 7-DIP Module, 5 Leads | Enclosed | Universal Input | TMP 30 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 30 W | 1 | 2.5A | 80% | 12V | - | - | - | - | - | ||||
![]() |
TMPS 05-103 | 19.1400 | ![]() |
40 | 0.00000000 | Traco Power | TMPS 05 (5W) | Box | Active | -25°C ~ 70°C (With Derating) | Household Appliances, ITE (Commercial) | 1.00" L x 1.00" W x 0.64" H (25.4mm x 25.4mm x 16.3mm) | Through Hole | 5-DIP Module | Enclosed | Universal Input | TMPS 05 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 5 W | 1 | 1.515A | 74% | 3.3V | - | - | - | - | - | ||||
![]() |
TMLM 04109 | 18.5800 | ![]() |
35 | 0.00000000 | Traco Power | TMLM (4W) | Box | Active | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 1.44" L x 1.06" W x 0.67" H (36.5mm x 27.0mm x 17.1mm) | Through Hole | 7-DIP Module | Enclosed | Universal Input | TMLM 04 | CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1157 | EAR99 | 8504.40.9510 | 10 | 4 W | 1 | 444mA | 72% | 9V | - | - | - | 0.3% | ±0.5% | |||
![]() |
TMLM 20112 | 52.3600 | ![]() |
25 | 0.00000000 | Traco Power | TMLM (20W) | Box | Active | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 2.06" L x 1.07" W x 0.93" H (52.4mm x 27.2mm x 23.5mm) | Through Hole | 4-DIP Module | Enclosed | Universal Input | TMLM 20 | CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1159 | EAR99 | 8504.40.9580 | 10 | 20 W | 1 | 1.66A | 82% | 12V | - | - | - | 0.5% | ±1% | |||
![]() |
TMP 10215 | - | ![]() |
7658 | 0.00000000 | Traco Power | TMP (10W) | Box | Obsolete | -25°C ~ 50°C | ITE (Commercial) | 2.52" L x 1.77" W x 0.76" H (64.0mm x 45.0mm x 19.2mm) | Through Hole | 5-DIP Module | Enclosed | Universal Input | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1162 | EAR99 | 8504.40.9510 | 10 | 9 W | 2 | 300mA, 300mA | 77% | 15V | - | - | - | 1%, 3% | ±1% | ||||
![]() |
TML 40124 | 82.4200 | ![]() |
170 | 0.00000000 | Traco Power | TML (40W) | Box | Active | -40°C ~ 60°C (With Derating) | ITE (Commercial) | 3.52" L x 2.52" W x 0.98" H (89.5mm x 64.1mm x 25.0mm) | Through Hole | 8-DIP Module, 5 Leads | Enclosed | Universal Input | TML 40 | CB, CE, cURus | 90 ~ 264 VAC, 100 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1284 | EAR99 | 8504.40.9510 | 10 | 40 W | 1 | 1.667A | 84% | 24V | - | - | - | 0.5% | ±0.5% | |||
![]() |
TMPM 04124 | - | ![]() |
8886 | 0.00000000 | Traco Power | TMPM (4W) | Box | Obsolete | -25°C ~ 60°C | ITE (Commercial) | 1.44" L x 1.06" W x 0.67" H (36.5mm x 27.0mm x 17.1mm) | Through Hole | 7-DIP Module, 6 Leads | Enclosed | Universal Input | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1355 | EAR99 | 8504.40.9510 | 10 | 4 W | 1 | 167mA | 77% | 24V | - | - | - | 1% | 1% | ||||
![]() |
TPP 30-105A-D | 49.3800 | ![]() |
11 | 0.00000000 | Traco Power | TPP 30A-D (30W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 2.74" L x 1.36" W x 0.95" H (69.7mm x 34.6mm x 24.1mm) | Through Hole | 5-DIP Module | Open Frame | Adjustable Output, Universal Input | TPP 30 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-2857 | EAR99 | 8504.40.9510 | 1 | 30 W | 1 | 6A | 87% | 5V | - | - | - | - | 0.70% | |||
![]() |
TPP 30-109A-D | 44.5600 | ![]() |
1 | 0.00000000 | Traco Power | TPP 30A-D (30W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 2.74" L x 1.36" W x 0.95" H (69.7mm x 34.6mm x 24.1mm) | Through Hole | 5-DIP Module | Open Frame | Adjustable Output, Universal Input | TPP 30 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-2858 | EAR99 | 8504.40.9510 | 1 | 30 W | 1 | 3.34A | 88% | 9V | - | - | - | - | 0.5% | |||
![]() |
TPP 15-103-D | 44.6500 | ![]() |
2 | 0.00000000 | Traco Power | TPP 15-D (15W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 1.65" L x 1.14" W x 0.85" H (42.0mm x 28.9mm x 21.5mm) | Through Hole | 5-DIP Module | Enclosed | Adjustable Output, Universal Input | TPP 15 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-2888 | EAR99 | 8504.40.9510 | 1 | 13 W | 1 | 4A | 84% | 3.3V | - | - | - | - | 0.70% | |||
![]() |
TMPM 10105 | 37.4600 | ![]() |
261 | 0.00000000 | Traco Power | TMPM (10W) | Box | Active | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 2.06" L x 1.07" W x 0.93" H (52.4mm x 27.2mm x 23.5mm) | Through Hole | 4-DIP Module | Enclosed | Universal Input | TMPM 10 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1173 | EAR99 | 8504.40.9510 | 10 | 10 W | 1 | 2A | 72% | 5V | - | - | - | 1% | ±1% | |||
![]() |
TMPW 10-115 | 17.9800 | ![]() |
7 | 0.00000000 | Traco Power | TMPW 10 (10W) | Box | Active | -40°C ~ 70°C (With Derating) | Household Appliances, ITE (Commercial) | 1.46" L x 1.08" W x 0.79" H (37.0mm x 27.5mm x 20.0mm) | Through Hole | 5-DIP Module | Enclosed | - | TMPW 10 | CB, cURus | 90 ~ 305 VAC, 100 ~ 250 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TMPW10-115 | EAR99 | 8504.40.9510 | 10 | 10 W | 1 | 667mA | 86% | 15V | - | - | - | - | - | |||
![]() |
TMPS 10-105 | 27.4700 | ![]() |
8481 | 0.00000000 | Traco Power | TMPS 10 (10W) | Tube | Active | -25°C ~ 70°C (With Derating) | Household Appliances, ITE (Commercial) | 1.50" L x 1.00" W x 0.62" H (38.1mm x 25.4mm x 15.7mm) | Through Hole | 4-DIP Module | Enclosed | Universal Input | TMPS 10 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-3264 | EAR99 | 8504.40.9510 | 10 | 10 W | 1 | 2A | 80% | 5V | - | - | - | - | ±1% | |||
![]() |
TPP 30-105-D | 68.0400 | ![]() |
32 | 0.00000000 | Traco Power | TPP 30-D (30W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 2.89" L x 1.50" W x 1.01" H (73.3mm x 38.1mm x 25.6mm) | Through Hole | 5-DIP Module | Enclosed | Adjustable Output, Universal Input | TPP 30 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-2865 | EAR99 | 8504.40.9510 | 1 | 30 W | 1 | 6A | 87% | 5V | - | - | - | - | 0.70% | |||
![]() |
TPP 65-112E-D | 74.0300 | ![]() |
3032 | 0.00000000 | Traco Power | TPP 65E-D (65W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 3.20" L x 2.20" W x 1.20" H (81.3mm x 55.9mm x 30.5mm) | Through Hole | 6-DIP Module, 5 Leads | Enclosed | DC Input Capable, Universal Input | CB, CE, CSA, cURus, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | - | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP65-112E-D | EAR99 | 8504.40.9520 | 1 | 65 W | 1 | 5.42A | 93% | 12V | - | - | - | 60601-1; 62368-1 | 0.2% | 0.5% | ||
![]() |
TMPS 15-124 | 33.8400 | ![]() |
4 | 0.00000000 | Traco Power | TMPS 15 (15W) | Box | Active | -25°C ~ 70°C | Household Appliances, ITE (Commercial) | 2.06" L x 1.07" W x 0.93" H (52.4mm x 27.2mm x 23.5mm) | Through Hole | 4-DIP Module | Enclosed | Universal Input | CB, CE, cURus, EAC, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | - | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TMPS15-124 | EAR99 | 8504.40.9510 | 10 | 15 W | 1 | 625mA | 84% | 24V | - | - | - | 60335-1; 62368-1 | 0.5% | 1% | ||
![]() |
TMT 30505 | - | ![]() |
9263 | 0.00000000 | Traco Power | TMT (30W) | Box | Obsolete | -25°C ~ 50°C (With Derating) | ITE (Commercial), Medical | 3.39" L x 2.28" W x 1.10" H (86.0mm x 58.0mm x 28.0mm) | Through Hole | 8-DIP Module | Enclosed | Universal Input | TMT 30 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 85 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | TMT30505 | EAR99 | 8504.40.9510 | 5 | 31 W | 3 | 5A, 1A, 250mA | 83% | 5V | - | - | - | - | 500mV | |||
![]() |
TPP 15-112A-D | 34.1300 | ![]() |
32 | 0.00000000 | Traco Power | TPP 15A-D (15W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 1.50" L x 1.00" W x 0.82" H (38.1mm x 25.4mm x 20.8mm) | Through Hole | 5-DIP Module | Open Frame | Adjustable Output, Universal Input | TPP 15 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-2883 | EAR99 | 8504.40.9510 | 1 | 15 W | 1 | 1.25A | 87% | 12V | - | - | - | - | 0.5% | |||
![]() |
TMP 15112 | 41.4700 | ![]() |
20 | 0.00000000 | Traco Power | TMP (15W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 2.91" L x 2.13" W x 0.77" H (74.0mm x 54.0mm x 19.5mm) | Through Hole | 7-DIP Module, 4 Leads | Enclosed | Universal Input | TMP 15 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1301 | EAR99 | 8504.40.9510 | 5 | 15 W | 1 | 1.25A | 79% | 12V | - | - | - | 1% | ±1% | |||
![]() |
TMPM 10124 | 37.4600 | ![]() |
13 | 0.00000000 | Traco Power | TMPM (10W) | Box | Active | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 2.06" L x 1.07" W x 0.93" H (52.4mm x 27.2mm x 23.5mm) | Through Hole | 4-DIP Module | Enclosed | Universal Input | TMPM 10 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1174 | EAR99 | 8504.40.9510 | 10 | 10 W | 1 | 417mA | 72% | 24V | - | - | - | 1% | ±1% | |||
![]() |
TML 10115 | - | ![]() |
2142 | 0.00000000 | Traco Power | TML | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 2.52" L x 1.77" W x 0.81" H (64.0mm x 45.0mm x 20.5mm) | Through Hole | 6-DIP Module | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 85 ~ 370 VDC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TML10115 | EAR99 | 8504.40.9510 | 10 | 10 W | 1 | 666mA | 80% | 15V | - | - | - | - | - | ||||
![]() |
TPP 15-109-D | 40.5700 | ![]() |
1 | 0.00000000 | Traco Power | TPP 15-D (15W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 1.65" L x 1.14" W x 0.85" H (42.0mm x 28.9mm x 21.5mm) | Through Hole | 5-DIP Module | Enclosed | Adjustable Output, Universal Input | TPP 15 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-2890 | EAR99 | 8504.40.9510 | 1 | 15 W | 1 | 1.67A | 86% | 9V | - | - | - | - | 0.5% | |||
![]() |
TML 05124 | - | ![]() |
9637 | 0.00000000 | Traco Power | TML | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 2.17" L x 1.77" W x 0.81" H (55.0mm x 45.0mm x 20.5mm) | Through Hole | 6-DIP Module | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 85 ~ 370 VDC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TML05124 | EAR99 | 8504.40.9510 | 10 | 4.8 W | 1 | 200mA | 80% | 24V | - | - | - | - | - |