Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Package / Case | Type | Features | Base Product Number | Approval Agency | Voltage - Input | Weight | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Current - Output (Max) | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Standard Number | Line Regulation | Load Regulation |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TMPS 03-103 | 17.7400 | ![]() |
2382 | 0.00000000 | Traco Power | TMPS 03 (3W) | Box | Active | -25°C ~ 70°C (With Derating) | Household Appliances, ITE (Commercial) | 1.00" L x 1.00" W x 0.64" H (25.4mm x 25.4mm x 16.3mm) | Through Hole | 5-DIP Module | Enclosed | Universal Input | TMPS 03 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1175 | EAR99 | 8504.40.9510 | 10 | 3 W | 1 | 900mA | 70% | 3.3V | - | - | - | 1% | ±1% | ||||
![]() |
TMW 24-105P | 50.9600 | ![]() |
19 | 0.00000000 | Traco Power | TMW 24P (24W) | Box | Active | -20°C ~ 80°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 2.09" L x 2.01" W x 0.96" H (53.0mm x 51.0mm x 24.5mm) | Through Hole | 4-DIP Module | Enclosed | - | CE, cURus, EAC, UKCA | 85 ~ 264 VAC | - | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TMW24-105P | EAR99 | 8504.40.9510 | 10 | 20 W | 1 | 4A | 85% | 5.1V | - | - | - | 60335-1; 60601-1; 62368-1 | - | ±2% | ||
![]() |
TMPW 10-112 | 17.9800 | ![]() |
16 | 0.00000000 | Traco Power | TMPW 10 (10W) | Box | Active | -40°C ~ 70°C (With Derating) | Household Appliances, ITE (Commercial) | 1.46" L x 1.08" W x 0.79" H (37.0mm x 27.5mm x 20.0mm) | Through Hole | 5-DIP Module | Enclosed | - | TMPW 10 | CB, cURus | 90 ~ 305 VAC, 100 ~ 250 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TMPW10-112 | EAR99 | 8504.40.7001 | 10 | 10 W | 1 | 833mA | 85% | 12V | - | - | - | - | - | |||
![]() |
TMPW 50-124 | 35.5800 | ![]() |
28 | 0.00000000 | Traco Power | TMPW 50 (50W) | Box | Active | -40°C ~ 70°C (With Derating) | Household Appliances, ITE (Commercial) | 2.92" L x 1.85" W x 0.91" H (74.2mm x 47.0mm x 23.1mm) | Through Hole | 4-DIP Module | Enclosed | - | TMPW 50 | CB, cURus | 90 ~ 305 VAC, 100 ~ 250 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TMPW50-124 | EAR99 | 8504.40.9510 | 10 | 50 W | 1 | 2.083A | 88% | 24V | - | - | - | - | - | |||
![]() |
TMLM 04112 | 18.5800 | ![]() |
1 | 0.00000000 | Traco Power | TMLM (4W) | Box | Active | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 1.44" L x 1.06" W x 0.67" H (36.5mm x 27.0mm x 17.1mm) | Through Hole | 7-DIP Module | Enclosed | Universal Input | TMLM 04 | CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1352 | EAR99 | 8504.40.9510 | 10 | 4 W | 1 | 333mA | 70% | 12V | - | - | - | 0.3% | ±0.5% | |||
![]() |
TMT 30112 | - | ![]() |
3475 | 0.00000000 | Traco Power | TMT (30W) | Box | Obsolete | -25°C ~ 50°C (With Derating) | ITE (Commercial), Medical | 2.99" L x 2.01" W x 1.10" H (76.0mm x 51.0mm x 28.0mm) | Through Hole | 5-DIP Module, 4 Leads | Enclosed | Universal Input | TMT 30 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 85 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | TMT30112 | EAR99 | 8504.40.9510 | 5 | 30 W | 1 | 2.5A | 83% | 12V | - | - | - | - | 50mV | |||
![]() |
TOM 12112 | - | ![]() |
4068 | 0.00000000 | Traco Power | TOM (12W) | Box | Obsolete | -10°C ~ 70°C (With Derating) | ITE (Commercial) | 2.56" L x 1.26" W x 0.91" H (65.0mm x 32.0mm x 23.0mm) | Through Hole | 5-DIP Module | Open Frame | Universal Input | CE, cURus | 85 ~ 264 VAC | - | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | TOM12112 | EAR99 | 8504.40.9510 | 10 | 12 W | 1 | 1A | 80% | 12V | - | - | - | - | 50mV | ||||
![]() |
TMLM 05112 | 40.5800 | ![]() |
6 | 0.00000000 | Traco Power | TMLM (5W) | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 2.00" L x 1.00" W x 0.60" H (50.8mm x 25.4mm x 15.2mm) | Through Hole | 4-DIP Module | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 5 W | 1 | 420mA | 75% | 12V | - | - | - | - | - | |||||
![]() |
TMPS 10-103 | 27.2100 | ![]() |
10 | 0.00000000 | Traco Power | TMPS 10 (10W) | Tube | Active | -25°C ~ 70°C (With Derating) | Household Appliances, ITE (Commercial) | 1.50" L x 1.00" W x 0.62" H (38.1mm x 25.4mm x 15.7mm) | Through Hole | 4-DIP Module | Enclosed | Universal Input | TMPS 10 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-3263 | EAR99 | 8504.40.9510 | 10 | 8.6 W | 1 | 2.6A | 77% | 3.3V | - | - | - | - | ±1% | |||
![]() |
TML 15115 | - | ![]() |
4891 | 0.00000000 | Traco Power | TML | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 2.91" L x 2.13" W x 0.87" H (74.0mm x 54.0mm x 22.0mm) | Through Hole | 8-DIP Module, 5 Leads | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 85 ~ 370 VDC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TML15115 | EAR99 | 8504.40.9510 | 10 | 15 W | 1 | 1A | 80% | 15V | - | - | - | - | - | ||||
![]() |
TMSB 2-2143 | - | ![]() |
6923 | 0.00000000 | Traco Power | TMSB 2 (2W) | Box | Obsolete | -30°C ~ 70°C (With Derating) | Household Appliances, ITE (Commercial) | 1.35" L x 1.12" W x 0.58" H (34.2mm x 28.4mm x 14.8mm) | Through Hole | 7-DIP Module | Enclosed | Universal Input | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 2.2 W | 2 | 143mA, 70mA | 70% | 14V | - | - | - | - | - | |||||
![]() |
TML 30124 | - | ![]() |
2967 | 0.00000000 | Traco Power | TML | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 3.50" L x 2.50" W x 0.98" H (88.9mm x 63.5mm x 25.0mm) | Through Hole | 7-DIP Module, 5 Leads | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 100 ~ 370 VDC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TML30124 | EAR99 | 8504.40.9510 | 10 | 30 W | 1 | 1.25A | 80% | 24V | - | - | - | - | - | ||||
![]() |
TML 30112 | - | ![]() |
3877 | 0.00000000 | Traco Power | TML | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 3.50" L x 2.50" W x 0.98" H (88.9mm x 63.5mm x 25.0mm) | Through Hole | 7-DIP Module, 5 Leads | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 100 ~ 370 VDC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TML30112 | EAR99 | 8504.40.9510 | 10 | 30 W | 1 | 2.5A | 80% | 12V | - | - | - | - | - | ||||
![]() |
TML 05115 | - | ![]() |
4758 | 0.00000000 | Traco Power | TML | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 2.17" L x 1.77" W x 0.81" H (55.0mm x 45.0mm x 20.5mm) | Through Hole | 6-DIP Module | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 85 ~ 370 VDC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TML05115 | EAR99 | 8504.40.9510 | 10 | 5 W | 1 | 333mA | 80% | 15V | - | - | - | - | - | ||||
![]() |
TML 10105 | - | ![]() |
8406 | 0.00000000 | Traco Power | TML | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 2.52" L x 1.77" W x 0.81" H (64.0mm x 45.0mm x 20.5mm) | Through Hole | 6-DIP Module | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 85 ~ 370 VDC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TML10105 | EAR99 | 8504.40.9510 | 10 | 10 W | 1 | 2A | 80% | 5V | - | - | - | - | - | ||||
![]() |
TML 15205 | - | ![]() |
1848 | 0.00000000 | Traco Power | TML | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 2.91" L x 2.13" W x 0.87" H (74.0mm x 54.0mm x 22.0mm) | Through Hole | 8-DIP Module, 6 Leads | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 85 ~ 370 VDC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TML15205 | EAR99 | 8504.40.9510 | 10 | 15 W | 2 | 1.5A, 1.5A | 80% | 5V | -5V | - | - | - | - | ||||
![]() |
TML 30512 | - | ![]() |
9974 | 0.00000000 | Traco Power | TML | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 3.50" L x 2.50" W x 0.98" H (88.9mm x 63.5mm x 25.0mm) | Through Hole | 7-DIP Module | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 100 ~ 370 VDC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TML30512 | EAR99 | 8504.40.9510 | 10 | 30 W | 3 | 3A, 630mA, 630mA | 80% | 5V | 12V | -12V | - | - | - | ||||
![]() |
TML 15215 | - | ![]() |
2269 | 0.00000000 | Traco Power | TML | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 2.91" L x 2.13" W x 0.87" H (74.0mm x 54.0mm x 22.0mm) | Through Hole | 8-DIP Module, 6 Leads | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 85 ~ 370 VDC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TML15215 | EAR99 | 8504.40.9510 | 10 | 15 W | 2 | 500mA, 500mA | 80% | 15V | - | - | - | - | - | ||||
![]() |
TMPW 25-112 | 25.6100 | ![]() |
77 | 0.00000000 | Traco Power | TMPW 25 (25W) | Box | Active | -40°C ~ 70°C (With Derating) | Household Appliances, ITE (Commercial) | 2.07" L x 1.08" W x 0.93" H (52.5mm x 27.5mm x 23.5mm) | Through Hole | 4-DIP Module | Enclosed | - | TMPW 25 | CB, cURus | 90 ~ 305 VAC, 100 ~ 250 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TMPW25-112 | EAR99 | 8504.40.9510 | 10 | 25 W | 1 | 2.083A | 88% | 12V | - | - | - | - | - | |||
![]() |
TMPW 25-105 | 25.6100 | ![]() |
14 | 0.00000000 | Traco Power | TMPW 25 (25W) | Box | Active | -40°C ~ 70°C (With Derating) | Household Appliances, ITE (Commercial) | 2.07" L x 1.08" W x 0.93" H (52.5mm x 27.5mm x 23.5mm) | Through Hole | 4-DIP Module | Enclosed | - | TMPW 25 | CB, cURus | 90 ~ 305 VAC, 100 ~ 250 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TMPW25-105 | EAR99 | 8504.40.9510 | 10 | 20 W | 1 | 3.922A | 84% | 5.1V | - | - | - | - | - | |||
![]() |
TMPW 50-115 | 35.5800 | ![]() |
10 | 0.00000000 | Traco Power | TMPW 50 (50W) | Box | Active | -40°C ~ 70°C (With Derating) | Household Appliances, ITE (Commercial) | 2.92" L x 1.85" W x 0.91" H (74.2mm x 47.0mm x 23.1mm) | Through Hole | 4-DIP Module | Enclosed | - | TMPW 50 | CB, cURus | 90 ~ 305 VAC, 100 ~ 250 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TMPW50-115 | EAR99 | 8504.40.9510 | 10 | 50 W | 1 | 3.333A | 88% | 15V | - | - | - | - | - | |||
![]() |
TMPW 5-112 | 15.1600 | ![]() |
4058 | 0.00000000 | Traco Power | TMPW 5 (5W) | Box | Active | -40°C ~ 70°C (With Derating) | Household Appliances, ITE (Commercial) | 1.46" L x 1.08" W x 0.69" H (37.0mm x 27.5mm x 17.5mm) | Through Hole | 5-DIP Module | Enclosed | - | CB, cURus | 90 ~ 305 VAC, 100 ~ 250 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TMPW5-112 | EAR99 | 8504.40.9510 | 10 | 5 W | 1 | 420mA | 81% | 12V | - | - | - | - | - | ||||
![]() |
TPP 40-115E-D | 70.7400 | ![]() |
18 | 0.00000000 | Traco Power | TPP 40E-D (40W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 3.20" L x 2.20" W x 1.20" H (81.3mm x 55.9mm x 30.5mm) | Through Hole | 6-DIP Module, 5 Leads | Enclosed | DC Input Capable, Universal Input | CB, CE, CSA, cURus, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | - | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP40-115E-D | EAR99 | 8504.40.9510 | 1 | 40 W | 1 | 2.67A | 92% | 15V | - | - | - | 60601-1; 62368-1 | 0.2% | 0.5% | ||
![]() |
TPP 40-148E-D | 67.6900 | ![]() |
16 | 0.00000000 | Traco Power | TPP 40E-D (40W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 3.20" L x 2.20" W x 1.20" H (81.3mm x 55.9mm x 30.5mm) | Through Hole | 6-DIP Module, 5 Leads | Enclosed | DC Input Capable, Universal Input | CB, CE, CSA, cURus, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | - | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP40-148E-D | EAR99 | 8504.40.9510 | 1 | 40 W | 1 | 840mA | 93% | 48V | - | - | - | 60601-1; 62368-1 | 0.2% | 0.5% | ||
![]() |
TPP 40-105E-D | 71.8800 | ![]() |
16 | 0.00000000 | Traco Power | TPP 40E-D (40W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 3.20" L x 2.20" W x 1.20" H (81.3mm x 55.9mm x 30.5mm) | Through Hole | 6-DIP Module, 5 Leads | Enclosed | DC Input Capable, Universal Input | CB, CE, CSA, cURus, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | - | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP40-105E-D | EAR99 | 8504.40.9510 | 1 | 40 W | 1 | 8A | 90% | 5V | - | - | - | 60601-1; 62368-1 | 0.2% | 0.5% | ||
![]() |
TPP 65-105E-D | 78.9100 | ![]() |
10 | 0.00000000 | Traco Power | TPP 65E-D (65W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 3.20" L x 2.20" W x 1.20" H (81.3mm x 55.9mm x 30.5mm) | Through Hole | 6-DIP Module, 5 Leads | Enclosed | DC Input Capable, Universal Input | CB, CE, CSA, cURus, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | - | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP65-105E-D | EAR99 | 8504.40.9510 | 1 | 50 W | 1 | 10A | 90% | 5V | - | - | - | 60601-1; 62368-1 | 0.2% | 0.5% | ||
![]() |
TMPS 15-105 | 33.8400 | ![]() |
8 | 0.00000000 | Traco Power | TMPS 15 (15W) | Box | Active | -25°C ~ 70°C | Household Appliances, ITE (Commercial) | 2.06" L x 1.07" W x 0.93" H (52.4mm x 27.2mm x 23.5mm) | Through Hole | 4-DIP Module | Enclosed | Universal Input | CB, CE, cURus, EAC, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | - | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TMPS15-105 | EAR99 | 8504.40.9510 | 10 | 15 W | 1 | 3A | 79% | 5V | - | - | - | 60335-1; 62368-1 | 0.5% | 1% | ||
![]() |
TMG 50148 | 81.6200 | ![]() |
2169 | 0.00000000 | Traco Power | TMG (50W) | Box | Active | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 2.92" L x 2.13" W x 0.86" H (74.1mm x 54.1mm x 21.8mm) | Through Hole | 4-DIP Module | Enclosed | Universal Input | TMG 50 | CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 50 W | 1 | 1.04A | 89% | 48V | - | - | - | - | - | ||||
![]() |
TML 20103 | 53.2430 | ![]() |
4628 | 0.00000000 | Traco Power | TML (20W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 2.74" L x 1.87" W x 0.85" H (69.5mm x 47.5mm x 21.7mm) | Through Hole | 8-DIP Module, 5 Leads | Enclosed | Universal Input | TML 20 | CB, CE, cURus | 90 ~ 264 VAC, 100 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 15 W | 1 | 4.5A | 84% | 3.3V | - | - | - | - | - | ||||
![]() |
TMLM 10115 | - | ![]() |
7698 | 0.00000000 | Traco Power | TMLM (10W) | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 2.06" L x 1.07" W x 0.93" H (52.4mm x 27.2mm x 23.5mm) | Through Hole | 4-DIP Module | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 10 W | 1 | 667mA | 78% | 15V | - | - | - | - | - |