Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-0ABDDG-P-A-DK00000 Advanced Energy CX10S-0ABDDG-P-A-DK00000 -
RFQ
ECAD 2599 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0ABDDG-P-A-DK00000 EAR99 8504.40.9540 1 805W 6 93% 5V 12V 48V 48V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 4.17 A 4.17 A 3 A 3 A
CX10S-AHBB0G-P-A-DK00000 Advanced Energy CX10S-AHBB0G-P-A-DK00000 -
RFQ
ECAD 6901 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AHBB0G-P-A-DK00000 EAR99 8504.40.9540 1 685W 7 93% 5V 5V 24V 12V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 6 A 3 A 15 A 15 A 3 A
CX10S-0BC0GH-P-A-DK00000 Advanced Energy CX10S-0BC0GH-P-A-DK00000 -
RFQ
ECAD 5583 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0BC0GH-P-A-DK00000 EAR99 8504.40.9540 1 600W 6 93% 12V 24V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 3 A 3 A 6 A 3 A
CX10S-AH0BCD-P-A-DK00000 Advanced Energy CX10S-AH0BCD-P-A-DK00000 -
RFQ
ECAD 4141 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AH0BCD-P-A-DK00000 EAR99 8504.40.9540 1 785W 6 93% 5V 5V 24V 12V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 21 A 6 A 3 A 15 A 8.3 A 4.17 A
CX10S-AGDCCG-P-A-DK00000 Advanced Energy CX10S-AGDCCG-P-A-DK00000 -
RFQ
ECAD 9275 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AGDCCG-P-A-DK00000 EAR99 8504.40.9540 1 945W 8 93% 5V 24V 24V 48V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 3 A 3 A 4.17 A 8.3 A 8.3 A
CX10S-0C0CC0-P-A-DK00000 Advanced Energy CX10S-0C0CC0-P-A-DK00000 -
RFQ
ECAD 9280 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0C0CC0-P-A-DK00000 EAR99 8504.40.9540 1 600W 3 93% 24V 24V 24V - - - No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 8.3 A
CX10S-A0ACC0-P-A-DK00000 Advanced Energy CX10S-A0ACC0-P-A-DK00000 -
RFQ
ECAD 5227 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-A0ACC0-P-A-DK00000 EAR99 8504.40.9540 1 610W 4 93% 5V 5V 24V 24V - - No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 8.3 A 8.3 A
CX10S-A0H0BH-P-A-DK00000 Advanced Energy CX10S-A0H0BH-P-A-DK00000 -
RFQ
ECAD 1079 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-A0H0BH-P-A-DK00000 EAR99 8504.40.9540 1 485W 6 93% 5V 5V 24V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 6 A 3 A 15 A 6 A 3 A
CX10S-0HACHC-P-A-DK00000 Advanced Energy CX10S-0HACHC-P-A-DK00000 -
RFQ
ECAD 9348 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0HACHC-P-A-DK00000 EAR99 8504.40.9540 1 705W 7 93% 5V 24V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 8.3 A 6 A 3 A
CX10S-ADABBB-P-A-DK00000 Advanced Energy CX10S-ADABBB-P-A-DK00000 -
RFQ
ECAD 2941 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ADABBB-P-A-DK00000 EAR99 8504.40.9540 1 950W 6 93% 5V 48V 5V 12V 12V 12V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 21 A 15 A 15 A 15 A
CX10S-A000DC-P-A-DK00000 Advanced Energy CX10S-A000DC-P-A-DK00000 -
RFQ
ECAD 3721 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-A000DC-P-A-DK00000 EAR99 8504.40.9540 1 505W 3 93% 5V 48V 24V - - - No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 8.3 A
CX10S-0DHCDG-P-A-DK00000 Advanced Energy CX10S-0DHCDG-P-A-DK00000 -
RFQ
ECAD 3236 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DHCDG-P-A-DK00000 EAR99 8504.40.9540 1 820W 7 93% 48V 5V 24V 24V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 8.3 A 4.17 A 3 A
CX10S-A000GC-P-A-DK00000 Advanced Energy CX10S-A000GC-P-A-DK00000 -
RFQ
ECAD 3750 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-A000GC-P-A-DK00000 EAR99 8504.40.9540 1 425W 4 93% 5V 24V 24V 24V - - No 4 kV 60601-1; 60950-1; 62368-1 21 A 3 A 3 A 8.3 A
CX10S-AAAGCA-P-A-DK00000 Advanced Energy CX10S-AAAGCA-P-A-DK00000 -
RFQ
ECAD 7048 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AAAGCA-P-A-DK00000 EAR99 8504.40.9540 1 740W 7 93% 5V 5V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 21 A 3 A 3 A 8.3 A
CX10S-0CCBDH-P-A-DK00000 Advanced Energy CX10S-0CCBDH-P-A-DK00000 -
RFQ
ECAD 9802 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0CCBDH-P-A-DK00000 EAR99 8504.40.9540 1 880W 6 93% 24V 24V 12V 48V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 15 A 4.17 A 6 A 3 A
CX10S-AADGAA-P-A-DK00000 Advanced Energy CX10S-AADGAA-P-A-DK00000 -
RFQ
ECAD 5360 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AADGAA-P-A-DK00000 EAR99 8504.40.9540 1 740W 7 93% 5V 5V 48V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 4.17 A 3 A 3 A 21 A
CX10S-ABBAHD-P-A-DK00000 Advanced Energy CX10S-ABBAHD-P-A-DK00000 -
RFQ
ECAD 2424 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ABBAHD-P-A-DK00000 EAR99 8504.40.9540 1 870W 7 93% 5V 12V 12V 5V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 15 A 21 A 6 A 3 A
CX10S-ADBHB0-P-A-DK00000 Advanced Energy CX10S-ADBHB0-P-A-DK00000 -
RFQ
ECAD 5241 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ADBHB0-P-A-DK00000 EAR99 8504.40.9540 1 765W 6 93% 5V 48V 12V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 15 A 6 A 3 A 15 A
CX10S-0HACGA-P-A-DK00000 Advanced Energy CX10S-0HACGA-P-A-DK00000 -
RFQ
ECAD 1555 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0HACGA-P-A-DK00000 EAR99 8504.40.9540 1 630W 7 93% 5V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 8.3 A 3 A 3 A
CX10S-ABCG0D-P-A-DK00000 Advanced Energy CX10S-ABCG0D-P-A-DK00000 -
RFQ
ECAD 4878 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ABCG0D-P-A-DK00000 EAR99 8504.40.9540 1 805W 6 93% 5V 12V 24V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 8.3 A 3 A 3 A 4.17 A
CX10S-AGC0HD-P-A-DK00000 Advanced Energy CX10S-AGC0HD-P-A-DK00000 -
RFQ
ECAD 5027 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AGC0HD-P-A-DK00000 EAR99 8504.40.9540 1 725W 7 93% 5V 24V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 3 A 3 A 8.3 A 6 A 3 A
CX10S-0GGBGC-P-A-DK00000 Advanced Energy CX10S-0GGBGC-P-A-DK00000 -
RFQ
ECAD 3627 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0GGBGC-P-A-DK00000 EAR99 8504.40.9540 1 740W 8 93% 24V 24V 24V 24V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 15 A 3 A
CX10S-0BH0GB-P-A-DK00000 Advanced Energy CX10S-0BH0GB-P-A-DK00000 -
RFQ
ECAD 8409 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0BH0GB-P-A-DK00000 EAR99 8504.40.9540 1 580W 6 93% 12V 5V 24V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 6 A 3 A 3 A 3 A 15 A
CX10S-0BDGB0-P-A-DK00000 Advanced Energy CX10S-0BDGB0-P-A-DK00000 -
RFQ
ECAD 9657 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0BDGB0-P-A-DK00000 EAR99 8504.40.9540 1 680W 5 93% 12V 48V 24V 24V 12V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 4.17 A 3 A 3 A 15 A
CX10S-AH0CBB-P-A-DK00000 Advanced Energy CX10S-AH0CBB-P-A-DK00000 -
RFQ
ECAD 2984 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AH0CBB-P-A-DK00000 EAR99 8504.40.9540 1 765W 6 93% 5V 5V 24V 24V 12V 12V No 4 kV 60601-1; 60950-1; 62368-1 21 A 6 A 3 A 8.3 A 15 A 15 A
CX10S-ACHGCA-P-A-DK00000 Advanced Energy CX10S-ACHGCA-P-A-DK00000 -
RFQ
ECAD 7541 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ACHGCA-P-A-DK00000 EAR99 8504.40.9540 1 830W 8 93% 5V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 6 A 3 A 3 A 3 A
CX10S-ABHHBC-P-A-DK00000 Advanced Energy CX10S-ABHHBC-P-A-DK00000 -
RFQ
ECAD 1841 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ABHHBC-P-A-DK00000 EAR99 8504.40.9540 1 865W 8 93% 5V 12V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 6 A 3 A 6 A 3 A
CX10S-0AABH0-P-A-DK00000 Advanced Energy CX10S-0AABH0-P-A-DK00000 -
RFQ
ECAD 7770 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0AABH0-P-A-DK00000 EAR99 8504.40.9540 1 490W 5 93% 5V 5V 12V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 15 A 6 A 3 A
CX10S-A0CA00-P-A-DK00000 Advanced Energy CX10S-A0CA00-P-A-DK00000 -
RFQ
ECAD 4662 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-A0CA00-P-A-DK00000 EAR99 8504.40.9540 1 410W 3 93% 5V 24V 5V - - - No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 21 A
CX10S-0C0CG0-P-A-DK00000 Advanced Energy CX10S-0C0CG0-P-A-DK00000 -
RFQ
ECAD 5999 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0C0CG0-P-A-DK00000 EAR99 8504.40.9540 1 520W 4 93% 24V 24V 24V 24V - - No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 3 A 3 A