Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CX10S-CHD0AB-P-A-DK00000 | - | 8310 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-CHD0AB-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 785W | 6 | 93% | 24V | 5V | 24V | 48V | 5V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 6 A | 3 A | 4.17 A | 21 A | 15 A | |||
CX10S-CGBHCG-P-A-DK00000 | - | 9126 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-CGBHCG-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 920W | 9 | 93% | 24V | 24V | 24V | 12V | 5V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 3 A | 3 A | 15 A | 6 A | 3 A | |||
CX10S-AADHCA-P-A-DK00000 | - | 9859 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AADHCA-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 815W | 7 | 93% | 5V | 5V | 48V | 5V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 21 A | 4.17 A | 6 A | 3 A | 8.3 A | |||
CX10S-HBD0DG-P-A-DK00000 | - | 2974 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-HBD0DG-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 800W | 7 | 93% | 5V | 24V | 12V | 48V | 48V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 15 A | 4.17 A | 4.17 A | 3 A | |||
CX10S-CGBHCD-P-A-DK00000 | - | 4982 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-CGBHCD-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 1000W | 8 | 93% | 24V | 24V | 24V | 12V | 5V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 3 A | 3 A | 15 A | 6 A | 3 A | |||
CX10S-0DBCGH-P-A-DK00000 | - | 6541 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0DBCGH-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 800W | 7 | 93% | 48V | 12V | 24V | 24V | 24V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 4.17 A | 15 A | 8.3 A | 3 A | 3 A | 6 A | |||
CX10S-AACCBA-P-A-DK00000 | - | 5594 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AACCBA-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 895W | 6 | 93% | 5V | 5V | 24V | 24V | 12V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 21 A | 8.3 A | 8.3 A | 15 A | 21 A | |||
CX10S-DC0ACG-P-A-DK00000 | - | 5603 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-DC0ACG-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 625W | 6 | 93% | 48V | 24V | 5V | 24V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 4.17 A | 8.3 A | 21 A | 8.3 A | 3 A | 3 A | |||
CX10S-GB0AG0-P-A-DK00000 | - | 5735 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-GB0AG0-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 525W | 6 | 93% | 24V | 24V | 12V | 5V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 3 A | 3 A | 15 A | 21 A | 3 A | 3 A | |||
CX10S-CDHH0B-P-A-DK00000 | - | 5729 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-CDHH0B-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 780W | 7 | 93% | 24V | 48V | 5V | 24V | 5V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 4.17 A | 6 A | 3 A | 6 A | 3 A | |||
CX10S-GBH0C0-P-A-DK00000 | - | 8888 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-GBH0C0-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 600W | 6 | 93% | 24V | 24V | 12V | 5V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 3 A | 3 A | 15 A | 6 A | 3 A | 8.3 A | |||
CX10S-CGHGCB-P-A-DK00000 | - | 3645 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-CGHGCB-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 920W | 9 | 93% | 24V | 24V | 24V | 5V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 3 A | 3 A | 6 A | 3 A | 3 A | |||
CX10S-GCHAHC-P-A-DK00000 | - | 6953 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-GCHAHC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 825W | 9 | 93% | 24V | 24V | 24V | 5V | 24V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 3 A | 3 A | 8.3 A | 6 A | 3 A | 21 A | |||
CX10S-C0DCAH-P-A-DK00000 | - | 5463 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-C0DCAH-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 805W | 6 | 93% | 24V | 48V | 24V | 5V | 5V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 4.17 A | 8.3 A | 21 A | 6 A | 3 A | |||
CX10S-DHCGAH-P-A-DK00000 | - | 3280 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-DHCGAH-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 825W | 9 | 93% | 48V | 5V | 24V | 24V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 4.17 A | 6 A | 3 A | 8.3 A | 3 A | 3 A | |||
CX10S-CDGC0H-P-A-DK00000 | - | 1568 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-CDGC0H-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 820W | 7 | 93% | 24V | 48V | 24V | 24V | 24V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 4.17 A | 3 A | 3 A | 8.3 A | 6 A | |||
CX10S-AHGB0C-P-A-DK00000 | - | 1443 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AHGB0C-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 705W | 7 | 93% | 5V | 5V | 24V | 24V | 24V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 6 A | 3 A | 3 A | 3 A | 15 A | |||
CX10S-GCHAHA-P-A-DK00000 | - | 1543 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-GCHAHA-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 730W | 9 | 93% | 24V | 24V | 24V | 5V | 24V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 3 A | 3 A | 8.3 A | 6 A | 3 A | 21 A | |||
CX10S-DCH0AH-P-A-DK00000 | - | 6536 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-DCH0AH-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 505W | 7 | 93% | 48V | 24V | 5V | 24V | 5V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 4.17 A | 8.3 A | 6 A | 3 A | 21 A | 6 A | |||
CX10S-0GGCGH-P-A-DK00000 | - | 2257 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0GGCGH-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 660W | 9 | 93% | 24V | 24V | 24V | 24V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 3 A | 3 A | 3 A | 3 A | 8.3 A | 3 A | |||
CX10S-G0HHDA-P-A-DK00000 | - | 4822 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-G0HHDA-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 625W | 8 | 93% | 24V | 24V | 5V | 24V | 5V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 3 A | 3 A | 6 A | 3 A | 6 A | 3 A | |||
CX10S-GABGGD-P-A-DK00000 | - | 3503 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-GABGGD-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 845W | 9 | 93% | 24V | 24V | 5V | 12V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 3 A | 3 A | 21 A | 15 A | 3 A | 3 A | |||
CX10S-A00B0H-P-A-DK00000 | - | 3184 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-A00B0H-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 385W | 4 | 93% | 5V | 12V | 5V | 24V | - | - | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 15 A | 6 A | 3 A | |||||
CX10S-GCHB0C-P-A-DK00000 | - | 4270 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-GCHB0C-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 600W | 7 | 93% | 24V | 24V | 24V | 5V | 24V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 3 A | 3 A | 8.3 A | 6 A | 3 A | 15 A | |||
CX10S-CDBCCC-P-A-DK00000 | - | 6069 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-CDBCCC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 1000W | 6 | 93% | 24V | 48V | 12V | 24V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 4.17 A | 15 A | 8.3 A | 8.3 A | 8.3 A | |||
CX10S-DBBHBC-P-A-DK00000 | - | 6582 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-DBBHBC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 1000W | 7 | 93% | 48V | 12V | 12V | 5V | 24V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 4.17 A | 15 A | 15 A | 6 A | 3 A | 15 A | |||
CX10S-AGCBBC-P-A-DK00000 | - | 5666 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AGCBBC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 985W | 7 | 93% | 5V | 24V | 24V | 24V | 12V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 3 A | 3 A | 8.3 A | 15 A | 15 A | |||
CX10S-CC0H0H-P-A-DK00000 | - | 9634 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-CC0H0H-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 600W | 6 | 93% | 24V | 24V | 5V | 24V | 5V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 8.3 A | 6 A | 3 A | 6 A | 3 A | |||
CX10S-CA0BCC-P-A-DK00000 | - | 6815 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-CA0BCC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 885W | 5 | 93% | 24V | 5V | 12V | 24V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 21 A | 15 A | 8.3 A | 8.3 A | ||||
CX10S-A0DH0A-P-A-DK00000 | - | 9765 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-A0DH0A-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 510W | 5 | 93% | 5V | 48V | 5V | 24V | 5V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 4.17 A | 6 A | 3 A | 21 A |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse