Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CX10S-AABCG0-P-A-DK00000 | - | 3253 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AABCG0-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 710W | 6 | 93% | 5V | 5V | 12V | 24V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 21 A | 15 A | 8.3 A | 3 A | 3 A | |||
CX10S-ADGC0D-P-A-DK00000 | - | 5274 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-ADGC0D-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 825W | 6 | 93% | 5V | 48V | 24V | 24V | 24V | 48V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 4.17 A | 3 A | 3 A | 8.3 A | 4.17 A | |||
CX10S-AGCDHG-P-A-DK00000 | - | 6646 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AGCDHG-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 845W | 9 | 93% | 5V | 24V | 24V | 24V | 48V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 3 A | 3 A | 8.3 A | 4.17 A | 6 A | |||
CX10S-0HA0HG-P-A-DK00000 | - | 8692 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0HA0HG-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 425W | 7 | 93% | 5V | 24V | 5V | 5V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 21 A | 6 A | 3 A | 3 A | |||
CX10S-AAACB0-P-A-DK00000 | - | 2059 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AAACB0-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 695W | 5 | 93% | 5V | 5V | 5V | 24V | 12V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 21 A | 21 A | 8.3 A | 15 A | ||||
CX10S-ABABHA-P-A-DK00000 | - | 5508 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-ABABHA-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 775W | 7 | 93% | 5V | 12V | 5V | 12V | 5V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 15 A | 21 A | 15 A | 6 A | 3 A | |||
CX10S-AGCDHC-P-A-DK00000 | - | 7660 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AGCDHC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 925W | 8 | 93% | 5V | 24V | 24V | 24V | 48V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 3 A | 3 A | 8.3 A | 4.17 A | 6 A | |||
CX10S-00CDBB-P-A-DK00000 | - | 3747 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-00CDBB-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 760W | 4 | 93% | 24V | 48V | 12V | 12V | - | - | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 4.17 A | 15 A | 15 A | |||||
CX10S-AABCDD-P-A-DK00000 | - | 2836 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AABCDD-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 990W | 6 | 93% | 5V | 5V | 12V | 24V | 48V | 48V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 21 A | 15 A | 8.3 A | 4.17 A | 4.17 A | |||
CX10S-0GG0DB-P-A-DK00000 | - | 9137 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0GG0DB-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 620W | 6 | 93% | 24V | 24V | 24V | 24V | 48V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 3 A | 3 A | 3 A | 3 A | 4.17 A | 15 A | |||
CX10S-AADC0B-P-A-DK00000 | - | 4439 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AADC0B-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 790W | 5 | 93% | 5V | 5V | 48V | 24V | 12V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 21 A | 4.17 A | 8.3 A | 15 A | ||||
CX10S-ABAHGB-P-A-DK00000 | - | 8019 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-ABAHGB-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 790W | 8 | 93% | 5V | 12V | 5V | 5V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 15 A | 21 A | 6 A | 3 A | 3 A | |||
CX10S-ACHCBC-P-A-DK00000 | - | 6971 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-ACHCBC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 985W | 7 | 93% | 5V | 24V | 5V | 24V | 24V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 8.3 A | 6 A | 3 A | 8.3 A | 15 A | |||
CX10S-ABCC00-P-A-DK00000 | - | 5725 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-ABCC00-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 685W | 4 | 93% | 5V | 12V | 24V | 24V | - | - | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 15 A | 8.3 A | 8.3 A | |||||
CX10S-0GADGC-P-A-DK00000 | - | 6746 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0GADGC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 745W | 7 | 93% | 24V | 24V | 5V | 48V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 3 A | 3 A | 21 A | 4.17 A | 3 A | 3 A | |||
CX10S-ACGBHD-P-A-DK00000 | - | 6275 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-ACGBHD-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 905W | 8 | 93% | 5V | 24V | 24V | 24V | 12V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 8.3 A | 3 A | 3 A | 15 A | 6 A | |||
CX10S-0AHBGA-P-A-DK00000 | - | 5426 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0AHBGA-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 610W | 7 | 93% | 5V | 5V | 24V | 12V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 6 A | 3 A | 15 A | 3 A | 3 A | |||
CX10S-0CBDBG-P-A-DK00000 | - | 1869 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0CBDBG-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 880W | 6 | 93% | 24V | 12V | 48V | 12V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 15 A | 4.17 A | 15 A | 3 A | 3 A | |||
CX10S-0CDDDB-P-A-DK00000 | - | 6914 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0CDDDB-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 980W | 5 | 93% | 24V | 48V | 48V | 48V | 12V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 4.17 A | 4.17 A | 4.17 A | 15 A | ||||
CX10S-0B0GGH-P-A-DK00000 | - | 4447 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0B0GGH-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 520W | 7 | 93% | 12V | 24V | 24V | 24V | 24V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 15 A | 3 A | 3 A | 3 A | 3 A | 6 A | |||
CX10S-0G0ACD-P-A-DK00000 | - | 3492 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0G0ACD-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 625W | 5 | 93% | 24V | 24V | 5V | 24V | 48V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 3 A | 3 A | 21 A | 8.3 A | 4.17 A | ||||
CX10S-0BBGDB-P-A-DK00000 | - | 7789 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0BBGDB-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 860W | 6 | 93% | 12V | 12V | 24V | 24V | 48V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 15 A | 15 A | 3 A | 3 A | 4.17 A | 15 A | |||
CX10S-AG0GGA-P-A-DK00000 | - | 8057 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AG0GGA-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 570W | 8 | 93% | 5V | 24V | 24V | 24V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 3 A | 3 A | 3 A | 3 A | 3 A | |||
CX10S-A0BGGA-P-A-DK00000 | - | 2729 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-A0BGGA-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 630W | 7 | 93% | 5V | 12V | 24V | 24V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 15 A | 3 A | 3 A | 3 A | 3 A | |||
CX10S-0DCCB0-P-A-DK00000 | - | 8248 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0DCCB0-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 780W | 4 | 93% | 48V | 24V | 24V | 12V | - | - | No | 4 kV | 60601-1; 60950-1; 62368-1 | 4.17 A | 8.3 A | 8.3 A | 15 A | |||||
CX10S-ADHBGC-P-A-DK00000 | - | 7391 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-ADHBGC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 905W | 8 | 93% | 5V | 48V | 5V | 24V | 12V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 4.17 A | 6 A | 3 A | 15 A | 3 A | |||
CX10S-AADC00-P-A-DK00000 | - | 5262 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AADC00-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 610W | 4 | 93% | 5V | 5V | 48V | 24V | - | - | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 21 A | 4.17 A | 8.3 A | |||||
CX10S-AC0AHD-P-A-DK00000 | - | 5781 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AC0AHD-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 510W | 6 | 93% | 5V | 24V | 5V | 5V | 24V | 48V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 8.3 A | 21 A | 6 A | 3 A | 4.17 A | |||
CX10S-ADHH00-P-A-DK00000 | - | 8228 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-ADHH00-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 505W | 6 | 93% | 5V | 48V | 5V | 24V | 5V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 4.17 A | 6 A | 3 A | 6 A | 3 A | |||
CX10S-0HAACA-P-A-DK00000 | - | 8713 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0HAACA-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 615W | 6 | 93% | 5V | 24V | 5V | 5V | 24V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 21 A | 21 A | 8.3 A | 21 A |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse