SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-GDBDAA-P-A-DK00000 Advanced Energy CX10S-GDBDAA-P-A-DK00000 -
RFQ
ECAD 9755 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GDBDAA-P-A-DK00000 EAR99 8504.40.9540 1 910W 7 93% 24V 24V 48V 12V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 15 A 4.17 A 21 A
CX10S-GBHDGH-P-A-DK00000 Advanced Energy CX10S-GBHDGH-P-A-DK00000 -
RFQ
ECAD 3730 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GBHDGH-P-A-DK00000 EAR99 8504.40.9540 1 820W 10 93% 24V 24V 12V 5V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 6 A 3 A 4.17 A
CX10S-DGBDAB-P-A-DK00000 Advanced Energy CX10S-DGBDAB-P-A-DK00000 -
RFQ
ECAD 6005 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DGBDAB-P-A-DK00000 EAR99 8504.40.9540 1 985W 7 93% 48V 24V 24V 12V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 15 A 4.17 A 21 A
CX10S-DHGG0A-P-A-DK00000 Advanced Energy CX10S-DHGG0A-P-A-DK00000 -
RFQ
ECAD 5299 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DHGG0A-P-A-DK00000 EAR99 8504.40.9540 1 645W 8 93% 48V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 3 A 3 A 3 A
CX10S-D0DBB0-P-A-DK00000 Advanced Energy CX10S-D0DBB0-P-A-DK00000 -
RFQ
ECAD 9272 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-D0DBB0-P-A-DK00000 EAR99 8504.40.9540 1 760W 4 93% 48V 48V 12V 12V - - No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 15 A 15 A
CX10S-CHHBA0-P-A-DK00000 Advanced Energy CX10S-CHHBA0-P-A-DK00000 -
RFQ
ECAD 7455 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CHHBA0-P-A-DK00000 EAR99 8504.40.9540 1 685W 7 93% 24V 5V 24V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 6 A 3 A 15 A
CX10S-G00BAA-P-A-DK00000 Advanced Energy CX10S-G00BAA-P-A-DK00000 -
RFQ
ECAD 5002 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G00BAA-P-A-DK00000 EAR99 8504.40.9540 1 510W 5 93% 24V 24V 12V 5V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 21 A 21 A
CX10S-G0DDCA-P-A-DK00000 Advanced Energy CX10S-G0DDCA-P-A-DK00000 -
RFQ
ECAD 8105 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0DDCA-P-A-DK00000 EAR99 8504.40.9540 1 825W 6 93% 24V 24V 48V 48V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 4.17 A 8.3 A 21 A
CX10S-GCBCDG-P-A-DK00000 Advanced Energy CX10S-GCBCDG-P-A-DK00000 -
RFQ
ECAD 6232 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GCBCDG-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 24V 24V 24V 12V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 15 A 8.3 A 4.17 A
CX10S-DA0CGA-P-A-DK00000 Advanced Energy CX10S-DA0CGA-P-A-DK00000 -
RFQ
ECAD 7759 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DA0CGA-P-A-DK00000 EAR99 8504.40.9540 1 730W 6 93% 48V 5V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 8.3 A 3 A 3 A 21 A
CX10S-GBCGBD-P-A-DK00000 Advanced Energy CX10S-GBCGBD-P-A-DK00000 -
RFQ
ECAD 5700 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GBCGBD-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 24V 24V 12V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 8.3 A 3 A 3 A
CX10S-DDGBHD-P-A-DK00000 Advanced Energy CX10S-DDGBHD-P-A-DK00000 -
RFQ
ECAD 4863 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DDGBHD-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 48V 48V 24V 24V 12V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 3 A 3 A 15 A 6 A
CX10S-GACCGH-P-A-DK00000 Advanced Energy CX10S-GACCGH-P-A-DK00000 -
RFQ
ECAD 5550 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GACCGH-P-A-DK00000 EAR99 8504.40.9540 1 845W 9 93% 24V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 8.3 A 8.3 A 3 A
CX10S-CH0BHG-P-A-DK00000 Advanced Energy CX10S-CH0BHG-P-A-DK00000 -
RFQ
ECAD 6353 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CH0BHG-P-A-DK00000 EAR99 8504.40.9540 1 700W 8 93% 24V 5V 24V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 15 A 6 A 3 A
CX10S-GBG0D0-P-A-DK00000 Advanced Energy CX10S-GBG0D0-P-A-DK00000 -
RFQ
ECAD 7415 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GBG0D0-P-A-DK00000 EAR99 8504.40.9540 1 620W 6 93% 24V 24V 12V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 3 A 3 A 4.17 A
CX10S-DDBDAC-P-A-DK00000 Advanced Energy CX10S-DDBDAC-P-A-DK00000 -
RFQ
ECAD 7637 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DDBDAC-P-A-DK00000 EAR99 8504.40.9540 1 1000W 6 93% 48V 48V 12V 48V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 15 A 4.17 A 21 A 8.3 A
CX10S-GCBBDH-P-A-DK00000 Advanced Energy CX10S-GCBBDH-P-A-DK00000 -
RFQ
ECAD 6656 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GCBBDH-P-A-DK00000 EAR99 8504.40.9540 1 980W 8 93% 24V 24V 24V 12V 12V 48V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 15 A 15 A 4.17 A
CX10S-GCCHDA-P-A-DK00000 Advanced Energy CX10S-GCCHDA-P-A-DK00000 -
RFQ
ECAD 8247 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GCCHDA-P-A-DK00000 EAR99 8504.40.9540 1 925W 8 93% 24V 24V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 8.3 A 6 A 3 A
CX10S-D0B0GC-P-A-DK00000 Advanced Energy CX10S-D0B0GC-P-A-DK00000 -
RFQ
ECAD 2406 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-D0B0GC-P-A-DK00000 EAR99 8504.40.9540 1 700W 5 93% 48V 12V 24V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 15 A 3 A 3 A 8.3 A
CX10S-DHGGBD-P-A-DK00000 Advanced Energy CX10S-DHGGBD-P-A-DK00000 -
RFQ
ECAD 3891 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DHGGBD-P-A-DK00000 EAR99 8504.40.9540 1 920W 9 93% 48V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 3 A 3 A 3 A
CX10S-GDABCG-P-A-DK00000 Advanced Energy CX10S-GDABCG-P-A-DK00000 -
RFQ
ECAD 8402 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GDABCG-P-A-DK00000 EAR99 8504.40.9540 1 925W 8 93% 24V 24V 48V 5V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 21 A 15 A 8.3 A
CX10S-CHDDDA-P-A-DK00000 Advanced Energy CX10S-CHDDDA-P-A-DK00000 -
RFQ
ECAD 8174 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CHDDDA-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 24V 5V 24V 48V 48V 48V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 4.17 A 4.17 A 4.17 A
CX10S-DHDBCD-P-A-DK00000 Advanced Energy CX10S-DHDBCD-P-A-DK00000 -
RFQ
ECAD 3676 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DHDBCD-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 48V 5V 24V 48V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 4.17 A 15 A 8.3 A
CX10S-GBG0CG-P-A-DK00000 Advanced Energy CX10S-GBG0CG-P-A-DK00000 -
RFQ
ECAD 8211 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GBG0CG-P-A-DK00000 EAR99 8504.40.9540 1 740W 8 93% 24V 24V 12V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 3 A 3 A 8.3 A
CX10S-G0CAH0-P-A-DK00000 Advanced Energy CX10S-G0CAH0-P-A-DK00000 -
RFQ
ECAD 7648 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0CAH0-P-A-DK00000 EAR99 8504.40.9540 1 525W 6 93% 24V 24V 24V 5V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 21 A 6 A 3 A
CX10S-CH0BHA-P-A-DK00000 Advanced Energy CX10S-CH0BHA-P-A-DK00000 -
RFQ
ECAD 5151 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CH0BHA-P-A-DK00000 EAR99 8504.40.9540 1 685W 7 93% 24V 5V 24V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 15 A 6 A 3 A
CX10S-GBCGCH-P-A-DK00000 Advanced Energy CX10S-GBCGCH-P-A-DK00000 -
RFQ
ECAD 8251 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GBCGCH-P-A-DK00000 EAR99 8504.40.9540 1 920W 9 93% 24V 24V 12V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 8.3 A 3 A 3 A
CX10S-DGAA0G-P-A-DK00000 Advanced Energy CX10S-DGAA0G-P-A-DK00000 -
RFQ
ECAD 9950 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DGAA0G-P-A-DK00000 EAR99 8504.40.9540 1 650W 7 93% 48V 24V 24V 5V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 21 A 21 A 3 A
CX10S-CHAGA0-P-A-DK00000 Advanced Energy CX10S-CHAGA0-P-A-DK00000 -
RFQ
ECAD 5577 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CHAGA0-P-A-DK00000 EAR99 8504.40.9540 1 630W 7 93% 24V 5V 24V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 21 A 3 A 3 A
CX10S-G0AHAH-P-A-DK00000 Advanced Energy CX10S-G0AHAH-P-A-DK00000 -
RFQ
ECAD 3810 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0AHAH-P-A-DK00000 EAR99 8504.40.9540 1 530W 8 93% 24V 24V 5V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 6 A 3 A 21 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse