SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-DCC0GA-P-A-DK00000 Advanced Energy CX10S-DCC0GA-P-A-DK00000 -
RFQ
ECAD 3613 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DCC0GA-P-A-DK00000 EAR99 8504.40.9540 1 825W 6 93% 48V 24V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 8.3 A 3 A 3 A 21 A
CX10S-CBCBBG-P-A-DK00000 Advanced Energy CX10S-CBCBBG-P-A-DK00000 -
RFQ
ECAD 1138 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CBCBBG-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 24V 12V 24V 12V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 15 A 8.3 A 15 A 15 A 3 A
CX10S-H0CHHD-P-A-DK00000 Advanced Energy CX10S-H0CHHD-P-A-DK00000 -
RFQ
ECAD 1634 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-H0CHHD-P-A-DK00000 EAR99 8504.40.9540 1 700W 8 93% 5V 24V 24V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 8.3 A 6 A 3 A 6 A
CX10S-HBBGBD-P-A-DK00000 Advanced Energy CX10S-HBBGBD-P-A-DK00000 -
RFQ
ECAD 4869 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HBBGBD-P-A-DK00000 EAR99 8504.40.9540 1 960W 8 93% 5V 24V 12V 12V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 15 A 15 A 3 A 3 A
CX10S-DHBGCG-P-A-DK00000 Advanced Energy CX10S-DHBGCG-P-A-DK00000 -
RFQ
ECAD 1444 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DHBGCG-P-A-DK00000 EAR99 8504.40.9540 1 920W 9 93% 48V 5V 24V 12V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 15 A 3 A 3 A
CX10S-DHCHDA-P-A-DK00000 Advanced Energy CX10S-DHCHDA-P-A-DK00000 -
RFQ
ECAD 4782 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DHCHDA-P-A-DK00000 EAR99 8504.40.9540 1 905W 8 93% 48V 5V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 8.3 A 6 A 3 A
CX10S-DHDADA-P-A-DK00000 Advanced Energy CX10S-DHDADA-P-A-DK00000 -
RFQ
ECAD 9616 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DHDADA-P-A-DK00000 EAR99 8504.40.9540 1 910W 7 93% 48V 5V 24V 48V 5V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 4.17 A 21 A 4.17 A
CX10S-G0C0AG-P-A-DK00000 Advanced Energy CX10S-G0C0AG-P-A-DK00000 -
RFQ
ECAD 2147 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0C0AG-P-A-DK00000 EAR99 8504.40.9540 1 545W 6 93% 24V 24V 24V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 21 A 3 A 3 A
CX10S-GHCAH0-P-A-DK00000 Advanced Energy CX10S-GHCAH0-P-A-DK00000 -
RFQ
ECAD 6015 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GHCAH0-P-A-DK00000 EAR99 8504.40.9540 1 625W 8 93% 24V 24V 5V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 8.3 A 21 A
CX10S-DAC0GD-P-A-DK00000 Advanced Energy CX10S-DAC0GD-P-A-DK00000 -
RFQ
ECAD 5498 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DAC0GD-P-A-DK00000 EAR99 8504.40.9540 1 825W 6 93% 48V 5V 24V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 8.3 A 3 A 3 A 4.17 A
CX10S-CDBBDG-P-A-DK00000 Advanced Energy CX10S-CDBBDG-P-A-DK00000 -
RFQ
ECAD 5098 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CDBBDG-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 24V 48V 12V 12V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 4.17 A 15 A 15 A 4.17 A 3 A
CX10S-CBB0GG-P-A-DK00000 Advanced Energy CX10S-CBB0GG-P-A-DK00000 -
RFQ
ECAD 8205 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CBB0GG-P-A-DK00000 EAR99 8504.40.9540 1 800W 7 93% 24V 12V 12V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 15 A 15 A 3 A 3 A 3 A
CX10S-ABCBDC-P-A-DK00000 Advanced Energy CX10S-ABCBDC-P-A-DK00000 -
RFQ
ECAD 9398 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ABCBDC-P-A-DK00000 EAR99 8504.40.9540 1 1000W 6 93% 5V 12V 24V 12V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 8.3 A 15 A 4.17 A 8.3 A
CX10S-0BBG0B-P-A-DK00000 Advanced Energy CX10S-0BBG0B-P-A-DK00000 -
RFQ
ECAD 6397 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0BBG0B-P-A-DK00000 EAR99 8504.40.9540 1 660W 5 93% 12V 12V 24V 24V 12V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 15 A 3 A 3 A 15 A
CX10S-0CGHBC-P-A-DK00000 Advanced Energy CX10S-0CGHBC-P-A-DK00000 -
RFQ
ECAD 9646 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0CGHBC-P-A-DK00000 EAR99 8504.40.9540 1 800W 7 93% 24V 24V 24V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 6 A 3 A 15 A
CX10S-00BCB0-P-A-DK00000 Advanced Energy CX10S-00BCB0-P-A-DK00000 -
RFQ
ECAD 9365 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00BCB0-P-A-DK00000 EAR99 8504.40.9540 1 560W 3 93% 12V 24V 12V - - - No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 15 A
CX10S-0BBGAD-P-A-DK00000 Advanced Energy CX10S-0BBGAD-P-A-DK00000 -
RFQ
ECAD 8258 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0BBGAD-P-A-DK00000 EAR99 8504.40.9540 1 785W 6 93% 12V 12V 24V 24V 5V 48V No 4 kV 60601-1; 60950-1; 62368-1 15 A 15 A 3 A 3 A 21 A 4.17 A
CX10S-0HBBHH-P-A-DK00000 Advanced Energy CX10S-0HBBHH-P-A-DK00000 -
RFQ
ECAD 2412 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0HBBHH-P-A-DK00000 EAR99 8504.40.9540 1 660W 8 93% 5V 24V 12V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 15 A 15 A 6 A 3 A
CX10S-0DCCBH-P-A-DK00000 Advanced Energy CX10S-0DCCBH-P-A-DK00000 -
RFQ
ECAD 8466 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DCCBH-P-A-DK00000 EAR99 8504.40.9540 1 880W 6 93% 48V 24V 24V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 8.3 A 15 A 6 A 3 A
CX10S-00BCAH-P-A-DK00000 Advanced Energy CX10S-00BCAH-P-A-DK00000 -
RFQ
ECAD 5287 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00BCAH-P-A-DK00000 EAR99 8504.40.9540 1 585W 5 93% 12V 24V 5V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 21 A 6 A 3 A
CX10S-00G0G0-P-A-DK00000 Advanced Energy CX10S-00G0G0-P-A-DK00000 -
RFQ
ECAD 7739 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00G0G0-P-A-DK00000 EAR99 8504.40.9540 1 240W 4 93% 24V 24V 24V 24V - - No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A
CX10S-0HGCA0-P-A-DK00000 Advanced Energy CX10S-0HGCA0-P-A-DK00000 -
RFQ
ECAD 2450 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0HGCA0-P-A-DK00000 EAR99 8504.40.9540 1 525W 6 93% 5V 24V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 3 A 3 A 8.3 A 21 A
CX10S-ABHCDD-P-A-DK00000 Advanced Energy CX10S-ABHCDD-P-A-DK00000 -
RFQ
ECAD 6928 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ABHCDD-P-A-DK00000 EAR99 8504.40.9540 1 985W 7 93% 5V 12V 5V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 6 A 3 A 8.3 A 4.17 A
CX10S-ADCHCG-P-A-DK00000 Advanced Energy CX10S-ADCHCG-P-A-DK00000 -
RFQ
ECAD 9761 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ADCHCG-P-A-DK00000 EAR99 8504.40.9540 1 925W 8 93% 5V 48V 24V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 8.3 A 6 A 3 A 8.3 A
CX10S-AAHACG-P-A-DK00000 Advanced Energy CX10S-AAHACG-P-A-DK00000 -
RFQ
ECAD 1180 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AAHACG-P-A-DK00000 EAR99 8504.40.9540 1 735W 8 93% 5V 5V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 6 A 3 A 21 A 8.3 A
CX10S-0AA0GA-P-A-DK00000 Advanced Energy CX10S-0AA0GA-P-A-DK00000 -
RFQ
ECAD 9232 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0AA0GA-P-A-DK00000 EAR99 8504.40.9540 1 435W 5 93% 5V 5V 24V 24V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 3 A 3 A 21 A
CX10S-ADGCDD-P-A-DK00000 Advanced Energy CX10S-ADGCDD-P-A-DK00000 -
RFQ
ECAD 7825 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ADGCDD-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 5V 48V 24V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 3 A 3 A 8.3 A 4.17 A
CX10S-0HAAGH-P-A-DK00000 Advanced Energy CX10S-0HAAGH-P-A-DK00000 -
RFQ
ECAD 8194 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0HAAGH-P-A-DK00000 EAR99 8504.40.9540 1 530W 8 93% 5V 24V 5V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 21 A 3 A 3 A
CX10S-00GA0C-P-A-DK00000 Advanced Energy CX10S-00GA0C-P-A-DK00000 -
RFQ
ECAD 5979 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00GA0C-P-A-DK00000 EAR99 8504.40.9540 1 425W 4 93% 24V 24V 5V 24V - - No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 8.3 A
CX10S-00GA0G-P-A-DK00000 Advanced Energy CX10S-00GA0G-P-A-DK00000 -
RFQ
ECAD 8323 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00GA0G-P-A-DK00000 EAR99 8504.40.9540 1 345W 5 93% 24V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 3 A 3 A