Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-D0GDCB-P-A-DK00000 Advanced Energy CX10S-D0GDCB-P-A-DK00000 -
RFQ
ECAD 9742 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-D0GDCB-P-A-DK00000 EAR99 8504.40.9540 1 900W 6 93% 48V 24V 24V 48V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 4.17 A 8.3 A 15 A
CX10S-GAHGGA-P-A-DK00000 Advanced Energy CX10S-GAHGGA-P-A-DK00000 -
RFQ
ECAD 7377 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GAHGGA-P-A-DK00000 EAR99 8504.40.9540 1 670W 10 93% 24V 24V 5V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 6 A 3 A 3 A
CX10S-D0G0DD-P-A-DK00000 Advanced Energy CX10S-D0G0DD-P-A-DK00000 -
RFQ
ECAD 8423 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-D0G0DD-P-A-DK00000 EAR99 8504.40.9540 1 720W 5 93% 48V 24V 24V 48V 48V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 4.17 A 4.17 A
CX10S-BGCDBH-P-A-DK00000 Advanced Energy CX10S-BGCDBH-P-A-DK00000 -
RFQ
ECAD 1926 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BGCDBH-P-A-DK00000 EAR99 8504.40.9540 1 980W 8 93% 12V 24V 24V 24V 48V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 3 A 3 A 8.3 A 4.17 A 15 A
CX10S-G0ACAG-P-A-DK00000 Advanced Energy CX10S-G0ACAG-P-A-DK00000 -
RFQ
ECAD 9095 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0ACAG-P-A-DK00000 EAR99 8504.40.9540 1 650W 7 93% 24V 24V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 8.3 A 21 A 3 A
CX10S-DHHBG0-P-A-DK00000 Advanced Energy CX10S-DHHBG0-P-A-DK00000 -
RFQ
ECAD 4084 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DHHBG0-P-A-DK00000 EAR99 8504.40.9540 1 700W 8 93% 48V 5V 24V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 6 A 3 A 15 A
CX10S-DHDHDB-P-A-DK00000 Advanced Energy CX10S-DHDHDB-P-A-DK00000 -
RFQ
ECAD 4442 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DHDHDB-P-A-DK00000 EAR99 8504.40.9540 1 980W 8 93% 48V 5V 24V 48V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 4.17 A 6 A 3 A
CX10S-GGAHHB-P-A-DK00000 Advanced Energy CX10S-GGAHHB-P-A-DK00000 -
RFQ
ECAD 3708 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GGAHHB-P-A-DK00000 EAR99 8504.40.9540 1 725W 10 93% 24V 24V 24V 24V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 21 A 6 A
CX10S-DDGGGB-P-A-DK00000 Advanced Energy CX10S-DDGGGB-P-A-DK00000 -
RFQ
ECAD 9224 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DDGGGB-P-A-DK00000 EAR99 8504.40.9540 1 940W 9 93% 48V 48V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 3 A 3 A 3 A 3 A
CX10S-BCDCDH-P-A-DK00000 Advanced Energy CX10S-BCDCDH-P-A-DK00000 -
RFQ
ECAD 4046 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BCDCDH-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 12V 24V 48V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 4.17 A 8.3 A 4.17 A 6 A
CX10S-GCACGD-P-A-DK00000 Advanced Energy CX10S-GCACGD-P-A-DK00000 -
RFQ
ECAD 1021 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GCACGD-P-A-DK00000 EAR99 8504.40.9540 1 945W 8 93% 24V 24V 24V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 21 A 8.3 A 3 A
CX10S-GGCBDD-P-A-DK00000 Advanced Energy CX10S-GGCBDD-P-A-DK00000 -
RFQ
ECAD 7536 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GGCBDD-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 24V 24V 24V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 8.3 A 15 A
CX10S-C0C0GH-P-A-DK00000 Advanced Energy CX10S-C0C0GH-P-A-DK00000 -
RFQ
ECAD 2047 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C0C0GH-P-A-DK00000 EAR99 8504.40.9540 1 620W 6 93% 24V 24V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 3 A 3 A 6 A 3 A
CX10S-GH0CGA-P-A-DK00000 Advanced Energy CX10S-GH0CGA-P-A-DK00000 -
RFQ
ECAD 1018 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GH0CGA-P-A-DK00000 EAR99 8504.40.9540 1 645W 8 93% 24V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 8.3 A 3 A
CX10S-GABC0D-P-A-DK00000 Advanced Energy CX10S-GABC0D-P-A-DK00000 -
RFQ
ECAD 4427 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GABC0D-P-A-DK00000 EAR99 8504.40.9540 1 805W 6 93% 24V 24V 5V 12V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 15 A 8.3 A 4.17 A
CX10S-DGCA00-P-A-DK00000 Advanced Energy CX10S-DGCA00-P-A-DK00000 -
RFQ
ECAD 2120 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DGCA00-P-A-DK00000 EAR99 8504.40.9540 1 625W 5 93% 48V 24V 24V 24V 5V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 8.3 A 21 A
CX10S-GGCHDA-P-A-DK00000 Advanced Energy CX10S-GGCHDA-P-A-DK00000 -
RFQ
ECAD 4040 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GGCHDA-P-A-DK00000 EAR99 8504.40.9540 1 845W 9 93% 24V 24V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 8.3 A 6 A
CX10S-G0CDCG-P-A-DK00000 Advanced Energy CX10S-G0CDCG-P-A-DK00000 -
RFQ
ECAD 5385 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0CDCG-P-A-DK00000 EAR99 8504.40.9540 1 840W 7 93% 24V 24V 24V 48V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 4.17 A 8.3 A 3 A
CX10S-GG0HDA-P-A-DK00000 Advanced Energy CX10S-GG0HDA-P-A-DK00000 -
RFQ
ECAD 5509 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GG0HDA-P-A-DK00000 EAR99 8504.40.9540 1 645W 8 93% 24V 24V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 6 A 3 A
CX10S-CH0GBH-P-A-DK00000 Advanced Energy CX10S-CH0GBH-P-A-DK00000 -
RFQ
ECAD 9127 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CH0GBH-P-A-DK00000 EAR99 8504.40.9540 1 700W 8 93% 24V 5V 24V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 3 A 3 A 15 A
CX10S-GGBDAA-P-A-DK00000 Advanced Energy CX10S-GGBDAA-P-A-DK00000 -
RFQ
ECAD 3671 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GGBDAA-P-A-DK00000 EAR99 8504.40.9540 1 830W 8 93% 24V 24V 24V 24V 12V 48V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 15 A 4.17 A
CX10S-G0ABCC-P-A-DK00000 Advanced Energy CX10S-G0ABCC-P-A-DK00000 -
RFQ
ECAD 3167 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0ABCC-P-A-DK00000 EAR99 8504.40.9540 1 805W 6 93% 24V 24V 5V 12V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 15 A 8.3 A 8.3 A
CX10S-G0HHH0-P-A-DK00000 Advanced Energy CX10S-G0HHH0-P-A-DK00000 -
RFQ
ECAD 4514 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0HHH0-P-A-DK00000 EAR99 8504.40.9540 1 420W 8 93% 24V 24V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 6 A 3 A
CX10S-G000CB-P-A-DK00000 Advanced Energy CX10S-G000CB-P-A-DK00000 -
RFQ
ECAD 9069 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G000CB-P-A-DK00000 EAR99 8504.40.9540 1 500W 4 93% 24V 24V 24V 12V - - No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 15 A
CX10S-BHBDCH-P-A-DK00000 Advanced Energy CX10S-BHBDCH-P-A-DK00000 -
RFQ
ECAD 7195 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BHBDCH-P-A-DK00000 EAR99 8504.40.9540 1 960W 8 93% 12V 5V 24V 12V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 6 A 3 A 15 A 4.17 A 8.3 A
CX10S-DACGGG-P-A-DK00000 Advanced Energy CX10S-DACGGG-P-A-DK00000 -
RFQ
ECAD 4570 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DACGGG-P-A-DK00000 EAR99 8504.40.9540 1 865W 9 93% 48V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 8.3 A 3 A 3 A 3 A
CX10S-DDBAC0-P-A-DK00000 Advanced Energy CX10S-DDBAC0-P-A-DK00000 -
RFQ
ECAD 9016 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DDBAC0-P-A-DK00000 EAR99 8504.40.9540 1 885W 5 93% 48V 48V 12V 5V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 15 A 21 A 8.3 A
CX10S-DDBAAD-P-A-DK00000 Advanced Energy CX10S-DDBAAD-P-A-DK00000 -
RFQ
ECAD 4894 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DDBAAD-P-A-DK00000 EAR99 8504.40.9540 1 990W 6 93% 48V 48V 12V 5V 5V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 15 A 21 A 21 A 4.17 A
CX10S-CDHDCB-P-A-DK00000 Advanced Energy CX10S-CDHDCB-P-A-DK00000 -
RFQ
ECAD 8582 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CDHDCB-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 24V 48V 5V 24V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 4.17 A 6 A 3 A 4.17 A 8.3 A
CX10S-DDG0BG-P-A-DK00000 Advanced Energy CX10S-DDG0BG-P-A-DK00000 -
RFQ
ECAD 3012 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DDG0BG-P-A-DK00000 EAR99 8504.40.9540 1 820W 7 93% 48V 48V 24V 24V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 3 A 3 A 15 A 3 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse