SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-000BDB-P-A-DK00000 Advanced Energy CX10S-000BDB-P-A-DK00000 -
RFQ
ECAD 8867 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-000BDB-P-A-DK00000 EAR99 8504.40.9540 1 560W 3 93% 12V 48V 12V - - - No 4 kV 60601-1; 60950-1; 62368-1 15 A 4.17 A 15 A
CX10S-AD0HDA-P-A-DK00000 Advanced Energy CX10S-AD0HDA-P-A-DK00000 -
RFQ
ECAD 5327 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AD0HDA-P-A-DK00000 EAR99 8504.40.9540 1 710W 6 93% 5V 48V 5V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 6 A 3 A 4.17 A 21 A
CX10S-AAD0HB-P-A-DK00000 Advanced Energy CX10S-AAD0HB-P-A-DK00000 -
RFQ
ECAD 4863 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AAD0HB-P-A-DK00000 EAR99 8504.40.9540 1 690W 6 93% 5V 5V 48V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 4.17 A 6 A 3 A 15 A
CX10S-G0CDHB-P-A-DK00000 Advanced Energy CX10S-G0CDHB-P-A-DK00000 -
RFQ
ECAD 4408 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0CDHB-P-A-DK00000 EAR99 8504.40.9540 1 800W 7 93% 24V 24V 24V 48V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 4.17 A 6 A 3 A
CX10S-0D0AHD-P-A-DK00000 Advanced Energy CX10S-0D0AHD-P-A-DK00000 -
RFQ
ECAD 8194 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0D0AHD-P-A-DK00000 EAR99 8504.40.9540 1 605W 5 93% 48V 5V 5V 24V 48V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 6 A 3 A 4.17 A
CX10S-A0CHCC-P-A-DK00000 Advanced Energy CX10S-A0CHCC-P-A-DK00000 -
RFQ
ECAD 3014 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-A0CHCC-P-A-DK00000 EAR99 8504.40.9540 1 805W 6 93% 5V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 6 A 3 A 8.3 A 8.3 A
CX10S-0GDHCC-P-A-DK00000 Advanced Energy CX10S-0GDHCC-P-A-DK00000 -
RFQ
ECAD 8359 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0GDHCC-P-A-DK00000 EAR99 8504.40.9540 1 820W 7 93% 24V 24V 48V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 6 A 3 A 8.3 A
CX10S-GGCBCH-P-A-DK00000 Advanced Energy CX10S-GGCBCH-P-A-DK00000 -
RFQ
ECAD 3162 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GGCBCH-P-A-DK00000 EAR99 8504.40.9540 1 920W 9 93% 24V 24V 24V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 8.3 A 15 A
CX10S-AAGH0G-P-A-DK00000 Advanced Energy CX10S-AAGH0G-P-A-DK00000 -
RFQ
ECAD 1421 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AAGH0G-P-A-DK00000 EAR99 8504.40.9540 1 550W 8 93% 5V 5V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 3 A 3 A 6 A 3 A
CX10S-AB0BCC-P-A-DK00000 Advanced Energy CX10S-AB0BCC-P-A-DK00000 -
RFQ
ECAD 8983 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AB0BCC-P-A-DK00000 EAR99 8504.40.9540 1 865W 5 93% 5V 12V 12V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 15 A 8.3 A 8.3 A
CX10S-DG0BBG-P-A-DK00000 Advanced Energy CX10S-DG0BBG-P-A-DK00000 -
RFQ
ECAD 6879 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DG0BBG-P-A-DK00000 EAR99 8504.40.9540 1 800W 7 93% 48V 24V 24V 12V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 15 A 15 A 3 A
CX10S-000DAC-P-A-DK00000 Advanced Energy CX10S-000DAC-P-A-DK00000 -
RFQ
ECAD 4185 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-000DAC-P-A-DK00000 EAR99 8504.40.9540 1 505W 3 93% 48V 5V 24V - - - No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 8.3 A
CX10S-GCGHBB-P-A-DK00000 Advanced Energy CX10S-GCGHBB-P-A-DK00000 -
RFQ
ECAD 9711 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GCGHBB-P-A-DK00000 EAR99 8504.40.9540 1 900W 9 93% 24V 24V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 3 A 3 A 6 A
CX10S-ABGHH0-P-A-DK00000 Advanced Energy CX10S-ABGHH0-P-A-DK00000 -
RFQ
ECAD 2666 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ABGHH0-P-A-DK00000 EAR99 8504.40.9540 1 605W 8 93% 5V 12V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 3 A 3 A 6 A 3 A
CX10S-0AHGHH-P-A-DK00000 Advanced Energy CX10S-0AHGHH-P-A-DK00000 -
RFQ
ECAD 2019 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0AHGHH-P-A-DK00000 EAR99 8504.40.9540 1 525W 9 93% 5V 5V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 6 A 3 A 3 A 3 A 6 A
CX10S-0ABBBB-P-A-DK00000 Advanced Energy CX10S-0ABBBB-P-A-DK00000 -
RFQ
ECAD 3418 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0ABBBB-P-A-DK00000 EAR99 8504.40.9540 1 825W 5 93% 5V 12V 12V 12V 12V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 15 A 15 A 15 A
CX10S-GGDH0G-P-A-DK00000 Advanced Energy CX10S-GGDH0G-P-A-DK00000 -
RFQ
ECAD 9635 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GGDH0G-P-A-DK00000 EAR99 8504.40.9540 1 660W 9 93% 24V 24V 24V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 4.17 A 6 A
CX10S-0GDGDA-P-A-DK00000 Advanced Energy CX10S-0GDGDA-P-A-DK00000 -
RFQ
ECAD 5567 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0GDGDA-P-A-DK00000 EAR99 8504.40.9540 1 745W 7 93% 24V 24V 48V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 3 A 3 A 4.17 A
CX10S-G0BBBA-P-A-DK00000 Advanced Energy CX10S-G0BBBA-P-A-DK00000 -
RFQ
ECAD 4454 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0BBBA-P-A-DK00000 EAR99 8504.40.9540 1 765W 6 93% 24V 24V 12V 12V 12V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 15 A 15 A 21 A
CX10S-0DCBAD-P-A-DK00000 Advanced Energy CX10S-0DCBAD-P-A-DK00000 -
RFQ
ECAD 3219 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DCBAD-P-A-DK00000 EAR99 8504.40.9540 1 885W 5 93% 48V 24V 12V 5V 48V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 15 A 21 A 4.17 A
CX10S-ACCCG0-P-A-DK00000 Advanced Energy CX10S-ACCCG0-P-A-DK00000 -
RFQ
ECAD 3855 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ACCCG0-P-A-DK00000 EAR99 8504.40.9540 1 625W 6 93% 5V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 8.3 A 8.3 A 3 A 3 A
CX10S-G0GAAC-P-A-DK00000 Advanced Energy CX10S-G0GAAC-P-A-DK00000 -
RFQ
ECAD 6566 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0GAAC-P-A-DK00000 EAR99 8504.40.9540 1 650W 7 93% 24V 24V 24V 24V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 21 A 21 A
CX10S-ABC00D-P-A-DK00000 Advanced Energy CX10S-ABC00D-P-A-DK00000 -
RFQ
ECAD 4491 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ABC00D-P-A-DK00000 EAR99 8504.40.9540 1 685W 4 93% 5V 12V 24V 48V - - No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 8.3 A 4.17 A
CX10S-DCBHGD-P-A-DK00000 Advanced Energy CX10S-DCBHGD-P-A-DK00000 -
RFQ
ECAD 2670 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DCBHGD-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 48V 24V 12V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 15 A 6 A 3 A 3 A
CX10S-AGBC0H-P-A-DK00000 Advanced Energy CX10S-AGBC0H-P-A-DK00000 -
RFQ
ECAD 2633 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AGBC0H-P-A-DK00000 EAR99 8504.40.9540 1 705W 7 93% 5V 24V 24V 12V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 3 A 3 A 15 A 8.3 A 6 A
CX10S-0CGGD0-P-A-DK00000 Advanced Energy CX10S-0CGGD0-P-A-DK00000 -
RFQ
ECAD 7443 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0CGGD0-P-A-DK00000 EAR99 8504.40.9540 1 640W 6 93% 24V 24V 24V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 3 A 3 A 4.17 A
CX10S-DBDAGG-P-A-DK00000 Advanced Energy CX10S-DBDAGG-P-A-DK00000 -
RFQ
ECAD 4466 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DBDAGG-P-A-DK00000 EAR99 8504.40.9540 1 925W 8 93% 48V 12V 48V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 15 A 4.17 A 21 A 3 A 3 A
CX10S-ACAGGB-P-A-DK00000 Advanced Energy CX10S-ACAGGB-P-A-DK00000 -
RFQ
ECAD 7077 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ACAGGB-P-A-DK00000 EAR99 8504.40.9540 1 830W 8 93% 5V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 21 A 3 A 3 A 3 A
CX10S-0DDCDC-P-A-DK00000 Advanced Energy CX10S-0DDCDC-P-A-DK00000 -
RFQ
ECAD 4336 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DDCDC-P-A-DK00000 EAR99 8504.40.9540 1 1000W 5 93% 48V 48V 24V 48V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 8.3 A 4.17 A 8.3 A
CX10S-AAABGG-P-A-DK00000 Advanced Energy CX10S-AAABGG-P-A-DK00000 -
RFQ
ECAD 9094 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AAABGG-P-A-DK00000 EAR99 8504.40.9540 1 735W 8 93% 5V 5V 5V 12V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 21 A 15 A 3 A 3 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse