SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-DAAHDD-P-A-DK00000 Advanced Energy CX10S-DAAHDD-P-A-DK00000 -
RFQ
ECAD 6849 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DAAHDD-P-A-DK00000 EAR99 8504.40.9540 1 910W 7 93% 48V 5V 5V 5V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 21 A 6 A 3 A 4.17 A
CX10S-GA0CHB-P-A-DK00000 Advanced Energy CX10S-GA0CHB-P-A-DK00000 -
RFQ
ECAD 4703 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GA0CHB-P-A-DK00000 EAR99 8504.40.9540 1 705W 7 93% 24V 24V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 8.3 A 6 A 3 A
CX10S-DGBGC0-P-A-DK00000 Advanced Energy CX10S-DGBGC0-P-A-DK00000 -
RFQ
ECAD 7895 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DGBGC0-P-A-DK00000 EAR99 8504.40.9540 1 820W 7 93% 48V 24V 24V 12V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 15 A 3 A 3 A
CX10S-DC0CC0-P-A-DK00000 Advanced Energy CX10S-DC0CC0-P-A-DK00000 -
RFQ
ECAD 8841 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DC0CC0-P-A-DK00000 EAR99 8504.40.9540 1 800W 4 93% 48V 24V 24V 24V - - No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 8.3 A 8.3 A
CX10S-GD0ACG-P-A-DK00000 Advanced Energy CX10S-GD0ACG-P-A-DK00000 -
RFQ
ECAD 5307 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GD0ACG-P-A-DK00000 EAR99 8504.40.9540 1 745W 7 93% 24V 24V 48V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 21 A 8.3 A 3 A
CX10S-G0H0D0-P-A-DK00000 Advanced Energy CX10S-G0H0D0-P-A-DK00000 -
RFQ
ECAD 9576 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0H0D0-P-A-DK00000 EAR99 8504.40.9540 1 420W 5 93% 24V 24V 5V 24V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 4.17 A
CX10S-GA0AGD-P-A-DK00000 Advanced Energy CX10S-GA0AGD-P-A-DK00000 -
RFQ
ECAD 3217 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GA0AGD-P-A-DK00000 EAR99 8504.40.9540 1 650W 7 93% 24V 24V 5V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 21 A 3 A 3 A
CX10S-DA00HD-P-A-DK00000 Advanced Energy CX10S-DA00HD-P-A-DK00000 -
RFQ
ECAD 5947 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DA00HD-P-A-DK00000 EAR99 8504.40.9540 1 605W 5 93% 48V 5V 5V 24V 48V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 6 A 3 A 4.17 A
CX10S-GG000A-P-A-DK00000 Advanced Energy CX10S-GG000A-P-A-DK00000 -
RFQ
ECAD 9757 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GG000A-P-A-DK00000 EAR99 8504.40.9540 1 345W 5 93% 24V 24V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 21 A
CX10S-DA0CAB-P-A-DK00000 Advanced Energy CX10S-DA0CAB-P-A-DK00000 -
RFQ
ECAD 2789 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DA0CAB-P-A-DK00000 EAR99 8504.40.9540 1 790W 5 93% 48V 5V 24V 5V 12V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 8.3 A 21 A 15 A
CX10S-G0H0CA-P-A-DK00000 Advanced Energy CX10S-G0H0CA-P-A-DK00000 -
RFQ
ECAD 6854 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0H0CA-P-A-DK00000 EAR99 8504.40.9540 1 525W 6 93% 24V 24V 5V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 8.3 A 21 A
CX10S-DCHBDB-P-A-DK00000 Advanced Energy CX10S-DCHBDB-P-A-DK00000 -
RFQ
ECAD 2347 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DCHBDB-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 48V 24V 5V 24V 12V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 6 A 3 A 15 A 4.17 A
CX10S-DB0CBG-P-A-DK00000 Advanced Energy CX10S-DB0CBG-P-A-DK00000 -
RFQ
ECAD 2348 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DB0CBG-P-A-DK00000 EAR99 8504.40.9540 1 880W 6 93% 48V 12V 24V 12V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 15 A 8.3 A 15 A 3 A 3 A
CX10S-GA0CHA-P-A-DK00000 Advanced Energy CX10S-GA0CHA-P-A-DK00000 -
RFQ
ECAD 5638 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GA0CHA-P-A-DK00000 EAR99 8504.40.9540 1 630W 7 93% 24V 24V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 8.3 A 6 A 3 A
CX10S-GDD0H0-P-A-DK00000 Advanced Energy CX10S-GDD0H0-P-A-DK00000 -
RFQ
ECAD 7721 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GDD0H0-P-A-DK00000 EAR99 8504.40.9540 1 620W 6 93% 24V 24V 48V 48V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 4.17 A 6 A 3 A
CX10S-GGC0HC-P-A-DK00000 Advanced Energy CX10S-GGC0HC-P-A-DK00000 -
RFQ
ECAD 8740 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GGC0HC-P-A-DK00000 EAR99 8504.40.9540 1 740W 8 93% 24V 24V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 8.3 A 6 A
CX10S-D0C0C0-P-A-DK00000 Advanced Energy CX10S-D0C0C0-P-A-DK00000 -
RFQ
ECAD 3865 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-D0C0C0-P-A-DK00000 EAR99 8504.40.9540 1 600W 3 93% 48V 24V 24V - - - No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 8.3 A
CX10S-GG0000-P-A-DK00000 Advanced Energy CX10S-GG0000-P-A-DK00000 -
RFQ
ECAD 7023 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GG0000-P-A-DK00000 EAR99 8504.40.9540 1 240W 4 93% 24V 24V 24V 24V - - No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A
CX10S-GAGA0G-P-A-DK00000 Advanced Energy CX10S-GAGA0G-P-A-DK00000 -
RFQ
ECAD 6301 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GAGA0G-P-A-DK00000 EAR99 8504.40.9540 1 570W 8 93% 24V 24V 5V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 3 A 3 A 21 A
CX10S-DAHBGH-P-A-DK00000 Advanced Energy CX10S-DAHBGH-P-A-DK00000 -
RFQ
ECAD 9496 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DAHBGH-P-A-DK00000 EAR99 8504.40.9540 1 805W 9 93% 48V 5V 5V 24V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 6 A 3 A 15 A 3 A
CX10S-DCBGA0-P-A-DK00000 Advanced Energy CX10S-DCBGA0-P-A-DK00000 -
RFQ
ECAD 2063 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DCBGA0-P-A-DK00000 EAR99 8504.40.9540 1 705W 6 93% 48V 24V 12V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 15 A 3 A 3 A 21 A
CX10S-DDHCDD-P-A-DK00000 Advanced Energy CX10S-DDHCDD-P-A-DK00000 -
RFQ
ECAD 1932 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DDHCDD-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 48V 48V 5V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 6 A 3 A 8.3 A 4.17 A
CX10S-DCCGBB-P-A-DK00000 Advanced Energy CX10S-DCCGBB-P-A-DK00000 -
RFQ
ECAD 2412 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DCCGBB-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 48V 24V 24V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 8.3 A 3 A 3 A 15 A
CX10S-GCBAGG-P-A-DK00000 Advanced Energy CX10S-GCBAGG-P-A-DK00000 -
RFQ
ECAD 5943 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GCBAGG-P-A-DK00000 EAR99 8504.40.9540 1 845W 9 93% 24V 24V 24V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 15 A 21 A 3 A
CX10S-DCCGDG-P-A-DK00000 Advanced Energy CX10S-DCCGDG-P-A-DK00000 -
RFQ
ECAD 1854 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DCCGDG-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 48V 24V 24V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 8.3 A 3 A 3 A 4.17 A
CX10S-DAH0GG-P-A-DK00000 Advanced Energy CX10S-DAH0GG-P-A-DK00000 -
RFQ
ECAD 8008 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DAH0GG-P-A-DK00000 EAR99 8504.40.9540 1 645W 8 93% 48V 5V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 6 A 3 A 3 A 3 A
CX10S-CHDH0A-P-A-DK00000 Advanced Energy CX10S-CHDH0A-P-A-DK00000 -
RFQ
ECAD 8046 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CHDH0A-P-A-DK00000 EAR99 8504.40.9540 1 705W 7 93% 24V 5V 24V 48V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 4.17 A 6 A 3 A
CX10S-CHGGCG-P-A-DK00000 Advanced Energy CX10S-CHGGCG-P-A-DK00000 -
RFQ
ECAD 6186 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CHGGCG-P-A-DK00000 EAR99 8504.40.9540 1 860W 10 93% 24V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 3 A 3 A 3 A
CX10S-DB0CCH-P-A-DK00000 Advanced Energy CX10S-DB0CCH-P-A-DK00000 -
RFQ
ECAD 9424 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DB0CCH-P-A-DK00000 EAR99 8504.40.9540 1 880W 6 93% 48V 12V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 15 A 8.3 A 8.3 A 6 A 3 A
CX10S-G0AGDG-P-A-DK00000 Advanced Energy CX10S-G0AGDG-P-A-DK00000 -
RFQ
ECAD 9093 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0AGDG-P-A-DK00000 EAR99 8504.40.9540 1 665W 8 93% 24V 24V 5V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 3 A 3 A 4.17 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse