Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CX10S-ADG0DH-P-A-DK00000 | - | 5002 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-ADG0DH-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 725W | 7 | 93% | 5V | 48V | 24V | 24V | 48V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 4.17 A | 3 A | 3 A | 4.17 A | 6 A | |||
CX10S-0CHGCA-P-A-DK00000 | - | 6976 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0CHGCA-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 725W | 7 | 93% | 24V | 5V | 24V | 24V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 6 A | 3 A | 3 A | 3 A | 8.3 A | |||
CX10S-0GBHGA-P-A-DK00000 | - | 7206 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0GBHGA-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 625W | 8 | 93% | 24V | 24V | 12V | 5V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 3 A | 3 A | 15 A | 6 A | 3 A | 3 A | |||
CX10S-0HCB0A-P-A-DK00000 | - | 2394 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0HCB0A-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 585W | 5 | 93% | 5V | 24V | 24V | 12V | 5V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 8.3 A | 15 A | 21 A | ||||
CX10S-0HGA0D-P-A-DK00000 | - | 7041 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0HGA0D-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 525W | 6 | 93% | 5V | 24V | 24V | 24V | 5V | 48V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 3 A | 3 A | 21 A | 4.17 A | |||
CX10S-0D00HA-P-A-DK00000 | - | 5490 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0D00HA-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 405W | 4 | 93% | 48V | 5V | 24V | 5V | - | - | No | 4 kV | 60601-1; 60950-1; 62368-1 | 4.17 A | 6 A | 3 A | 21 A | |||||
CX10S-ACDHDA-P-A-DK00000 | - | 9268 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-ACDHDA-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 910W | 7 | 93% | 5V | 24V | 48V | 5V | 24V | 48V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 8.3 A | 4.17 A | 6 A | 3 A | 4.17 A | |||
CX10S-AHAAG0-P-A-DK00000 | - | 9346 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AHAAG0-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 535W | 7 | 93% | 5V | 5V | 24V | 5V | 5V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 6 A | 3 A | 21 A | 21 A | 3 A | |||
CX10S-0CCHBC-P-A-DK00000 | - | 5001 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0CCHBC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 880W | 6 | 93% | 24V | 24V | 5V | 24V | 12V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 8.3 A | 6 A | 3 A | 15 A | 8.3 A | |||
CX10S-00CBDC-P-A-DK00000 | - | 7997 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-00CBDC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 780W | 4 | 93% | 24V | 12V | 48V | 24V | - | - | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 15 A | 4.17 A | 8.3 A | |||||
CX10S-AAGB0A-P-A-DK00000 | - | 7391 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AAGB0A-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 615W | 6 | 93% | 5V | 5V | 24V | 24V | 12V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 21 A | 3 A | 3 A | 15 A | 21 A | |||
CX10S-0HHAAB-P-A-DK00000 | - | 9686 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0HHAAB-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 590W | 7 | 93% | 5V | 24V | 5V | 24V | 5V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 6 A | 3 A | 21 A | 21 A | |||
CX10S-0A0BBH-P-A-DK00000 | - | 2643 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0A0BBH-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 565W | 5 | 93% | 5V | 12V | 12V | 5V | 24V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 15 A | 15 A | 6 A | 3 A | ||||
CX10S-ACAHB0-P-A-DK00000 | - | 5634 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-ACAHB0-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 490W | 6 | 93% | 5V | 24V | 5V | 5V | 24V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 8.3 A | 21 A | 6 A | 3 A | 15 A | |||
CX10S-AGBA0B-P-A-DK00000 | - | 5903 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AGBA0B-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 690W | 6 | 93% | 5V | 24V | 24V | 12V | 5V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 3 A | 3 A | 15 A | 21 A | 15 A | |||
CX10S-ACDBHD-P-A-DK00000 | - | 3991 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-ACDBHD-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 985W | 7 | 93% | 5V | 24V | 48V | 12V | 5V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 8.3 A | 4.17 A | 15 A | 6 A | 3 A | |||
CX10S-AGBCDC-P-A-DK00000 | - | 7653 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AGBCDC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 1000W | 7 | 93% | 5V | 24V | 24V | 12V | 24V | 48V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 3 A | 3 A | 15 A | 8.3 A | 4.17 A | |||
CX10S-000CAG-P-A-DK00000 | - | 2215 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-000CAG-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 325W | 4 | 93% | 24V | 5V | 24V | 24V | - | - | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 21 A | 3 A | 3 A | |||||
CX10S-00BHHG-P-A-DK00000 | - | 5675 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-00BHHG-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 500W | 7 | 93% | 12V | 5V | 24V | 5V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 15 A | 6 A | 3 A | 6 A | 3 A | 3 A | |||
CX10S-A0HCBH-P-A-DK00000 | - | 7341 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-A0HCBH-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 685W | 7 | 93% | 5V | 5V | 24V | 24V | 12V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 6 A | 3 A | 8.3 A | 15 A | 6 A | |||
CX10S-00B0CH-P-A-DK00000 | - | 3928 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-00B0CH-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 480W | 4 | 93% | 12V | 24V | 5V | 24V | - | - | No | 4 kV | 60601-1; 60950-1; 62368-1 | 15 A | 8.3 A | 6 A | 3 A | |||||
CX10S-AGA0CG-P-A-DK00000 | - | 5372 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AGA0CG-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 650W | 7 | 93% | 5V | 24V | 24V | 5V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 3 A | 3 A | 21 A | 8.3 A | 3 A | |||
CX10S-0DDAAC-P-A-DK00000 | - | 8070 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0DDAAC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 810W | 5 | 93% | 48V | 48V | 5V | 5V | 24V | 48V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 4.17 A | 4.17 A | 21 A | 21 A | 8.3 A | ||||
CX10S-AABGGB-P-A-DK00000 | - | 3748 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AABGGB-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 810W | 8 | 93% | 5V | 5V | 12V | 24V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 21 A | 15 A | 3 A | 3 A | 3 A | |||
CX10S-0BB0GB-P-A-DK00000 | - | 8161 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0BB0GB-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 660W | 5 | 93% | 12V | 12V | 24V | 24V | 12V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 15 A | 15 A | 3 A | 3 A | 15 A | ||||
CX10S-0CBGGA-P-A-DK00000 | - | 5117 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0CBGGA-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 725W | 7 | 93% | 24V | 12V | 24V | 24V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 15 A | 3 A | 3 A | 3 A | 3 A | |||
CX10S-AG0DHB-P-A-DK00000 | - | 4184 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AG0DHB-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 705W | 7 | 93% | 5V | 24V | 24V | 48V | 5V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 3 A | 3 A | 4.17 A | 6 A | 3 A | |||
CX10S-AGHCBC-P-A-DK00000 | - | 1232 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AGHCBC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 905W | 8 | 93% | 5V | 24V | 24V | 5V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 3 A | 3 A | 6 A | 3 A | 8.3 A | |||
CX10S-0HHCH0-P-A-DK00000 | - | 9075 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0HHCH0-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 500W | 7 | 93% | 5V | 24V | 5V | 24V | 24V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 6 A | 3 A | 8.3 A | 6 A | |||
CX10S-AD0GGH-P-A-DK00000 | - | 7727 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AD0GGH-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 645W | 8 | 93% | 5V | 48V | 24V | 24V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 4.17 A | 3 A | 3 A | 3 A | 3 A |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse