SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-ABACGG-P-A-DK00000 Advanced Energy CX10S-ABACGG-P-A-DK00000 -
RFQ
ECAD 9714 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ABACGG-P-A-DK00000 EAR99 8504.40.9540 1 830W 8 93% 5V 12V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 21 A 8.3 A 3 A 3 A
CX10S-HHG0DB-P-A-DK00000 Advanced Energy CX10S-HHG0DB-P-A-DK00000 -
RFQ
ECAD 4176 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HHG0DB-P-A-DK00000 EAR99 8504.40.9540 1 700W 8 93% 5V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 6 A 3 A 3 A 3 A
CX10S-0DDCBH-P-A-DK00000 Advanced Energy CX10S-0DDCBH-P-A-DK00000 -
RFQ
ECAD 8951 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DDCBH-P-A-DK00000 EAR99 8504.40.9540 1 880W 6 93% 48V 48V 24V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 8.3 A 15 A 6 A 3 A
CX10S-AAD0GH-P-A-DK00000 Advanced Energy CX10S-AAD0GH-P-A-DK00000 -
RFQ
ECAD 8552 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AAD0GH-P-A-DK00000 EAR99 8504.40.9540 1 630W 7 93% 5V 5V 48V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 4.17 A 3 A 3 A 6 A
CX10S-ACDGBC-P-A-DK00000 Advanced Energy CX10S-ACDGBC-P-A-DK00000 -
RFQ
ECAD 8947 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ACDGBC-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 5V 24V 48V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 4.17 A 3 A 3 A 15 A
CX10S-0DC00G-P-A-DK00000 Advanced Energy CX10S-0DC00G-P-A-DK00000 -
RFQ
ECAD 2353 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DC00G-P-A-DK00000 EAR99 8504.40.9540 1 520W 4 93% 48V 24V 24V 24V - - No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 3 A 3 A
CX10S-0DD0D0-P-A-DK00000 Advanced Energy CX10S-0DD0D0-P-A-DK00000 -
RFQ
ECAD 9193 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DD0D0-P-A-DK00000 EAR99 8504.40.9540 1 600W 3 93% 48V 48V 48V - - - No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 4.17 A
CX10S-0DGHCB-P-A-DK00000 Advanced Energy CX10S-0DGHCB-P-A-DK00000 -
RFQ
ECAD 9717 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DGHCB-P-A-DK00000 EAR99 8504.40.9540 1 800W 7 93% 48V 24V 24V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 6 A 3 A 8.3 A
CX10S-0DDCDG-P-A-DK00000 Advanced Energy CX10S-0DDCDG-P-A-DK00000 -
RFQ
ECAD 3682 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DDCDG-P-A-DK00000 EAR99 8504.40.9540 1 920W 6 93% 48V 48V 24V 48V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 8.3 A 4.17 A 3 A 3 A
CX10S-ACH0HG-P-A-DK00000 Advanced Energy CX10S-ACH0HG-P-A-DK00000 -
RFQ
ECAD 7805 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ACH0HG-P-A-DK00000 EAR99 8504.40.9540 1 425W 8 93% 5V 24V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 6 A 3 A 6 A 3 A
CX10S-0GBHD0-P-A-DK00000 Advanced Energy CX10S-0GBHD0-P-A-DK00000 -
RFQ
ECAD 1970 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0GBHD0-P-A-DK00000 EAR99 8504.40.9540 1 600W 6 93% 24V 24V 12V 5V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 6 A 3 A 4.17 A
CX10S-0H0AHD-P-A-DK00000 Advanced Energy CX10S-0H0AHD-P-A-DK00000 -
RFQ
ECAD 2980 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0H0AHD-P-A-DK00000 EAR99 8504.40.9540 1 505W 6 93% 5V 24V 5V 5V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 6 A 3 A 4.17 A
CX10S-AAGADA-P-A-DK00000 Advanced Energy CX10S-AAGADA-P-A-DK00000 -
RFQ
ECAD 5389 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AAGADA-P-A-DK00000 EAR99 8504.40.9540 1 740W 7 93% 5V 5V 24V 24V 5V 48V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 3 A 3 A 21 A 4.17 A
CX10S-AC000C-P-A-DK00000 Advanced Energy CX10S-AC000C-P-A-DK00000 -
RFQ
ECAD 5268 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AC000C-P-A-DK00000 EAR99 8504.40.9540 1 505W 3 93% 5V 24V 24V - - - No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 8.3 A
CX10S-0HAGD0-P-A-DK00000 Advanced Energy CX10S-0HAGD0-P-A-DK00000 -
RFQ
ECAD 7086 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0HAGD0-P-A-DK00000 EAR99 8504.40.9540 1 525W 6 93% 5V 24V 5V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 3 A 3 A 4.17 A
CX10S-0AH0HG-P-A-DK00000 Advanced Energy CX10S-0AH0HG-P-A-DK00000 -
RFQ
ECAD 7549 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0AH0HG-P-A-DK00000 EAR99 8504.40.9540 1 425W 7 93% 5V 5V 24V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 6 A 3 A 6 A 3 A 3 A
CX10S-0GGGHG-P-A-DK00000 Advanced Energy CX10S-0GGGHG-P-A-DK00000 -
RFQ
ECAD 6090 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0GGGHG-P-A-DK00000 EAR99 8504.40.9540 1 580W 10 93% 24V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 3 A 3 A
CX10S-0B0DBH-P-A-DK00000 Advanced Energy CX10S-0B0DBH-P-A-DK00000 -
RFQ
ECAD 4777 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0B0DBH-P-A-DK00000 EAR99 8504.40.9540 1 660W 5 93% 12V 48V 12V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 4.17 A 15 A 6 A 3 A
CX10S-ABC0CD-P-A-DK00000 Advanced Energy CX10S-ABC0CD-P-A-DK00000 -
RFQ
ECAD 6819 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ABC0CD-P-A-DK00000 EAR99 8504.40.9540 1 885W 5 93% 5V 12V 24V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 8.3 A 8.3 A 4.17 A
CX10S-0AAGDB-P-A-DK00000 Advanced Energy CX10S-0AAGDB-P-A-DK00000 -
RFQ
ECAD 6728 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0AAGDB-P-A-DK00000 EAR99 8504.40.9540 1 710W 6 93% 5V 5V 24V 24V 48V 12V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 3 A 3 A 4.17 A 15 A
CX10S-ADG0D0-P-A-DK00000 Advanced Energy CX10S-ADG0D0-P-A-DK00000 -
RFQ
ECAD 9852 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ADG0D0-P-A-DK00000 EAR99 8504.40.9540 1 625W 5 93% 5V 48V 24V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 3 A 3 A 4.17 A
CX10S-0HHABA-P-A-DK00000 Advanced Energy CX10S-0HHABA-P-A-DK00000 -
RFQ
ECAD 5217 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0HHABA-P-A-DK00000 EAR99 8504.40.9540 1 590W 7 93% 5V 24V 5V 24V 5V 12V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 6 A 3 A 21 A 15 A
CX10S-AABGAH-P-A-DK00000 Advanced Energy CX10S-AABGAH-P-A-DK00000 -
RFQ
ECAD 5771 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AABGAH-P-A-DK00000 EAR99 8504.40.9540 1 715W 8 93% 5V 5V 12V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 15 A 3 A 3 A 21 A
CX10S-0CGBAA-P-A-DK00000 Advanced Energy CX10S-0CGBAA-P-A-DK00000 -
RFQ
ECAD 1288 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0CGBAA-P-A-DK00000 EAR99 8504.40.9540 1 710W 6 93% 24V 24V 24V 12V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 15 A 21 A 21 A
CX10S-0HHCCH-P-A-DK00000 Advanced Energy CX10S-0HHCCH-P-A-DK00000 -
RFQ
ECAD 8112 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0HHCCH-P-A-DK00000 EAR99 8504.40.9540 1 700W 8 93% 5V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 6 A 3 A 8.3 A 8.3 A
CX10S-AGA0BC-P-A-DK00000 Advanced Energy CX10S-AGA0BC-P-A-DK00000 -
RFQ
ECAD 3916 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AGA0BC-P-A-DK00000 EAR99 8504.40.9540 1 710W 6 93% 5V 24V 24V 5V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 3 A 3 A 21 A 15 A 8.3 A
CX10S-0A0BG0-P-A-DK00000 Advanced Energy CX10S-0A0BG0-P-A-DK00000 -
RFQ
ECAD 3553 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0A0BG0-P-A-DK00000 EAR99 8504.40.9540 1 405W 4 93% 5V 12V 24V 24V - - No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 3 A 3 A
CX10S-00B0A0-P-A-DK00000 Advanced Energy CX10S-00B0A0-P-A-DK00000 -
RFQ
ECAD 7680 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00B0A0-P-A-DK00000 EAR99 8504.40.9540 1 285W 2 93% 12V 5V - - - - No 4 kV 60601-1; 60950-1; 62368-1 15 A 21 A
CX10S-00ACHH-P-A-DK00000 Advanced Energy CX10S-00ACHH-P-A-DK00000 -
RFQ
ECAD 9720 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00ACHH-P-A-DK00000 EAR99 8504.40.9540 1 505W 6 93% 5V 24V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 6 A 3 A 6 A 3 A
CX10S-ABDA0G-P-A-DK00000 Advanced Energy CX10S-ABDA0G-P-A-DK00000 -
RFQ
ECAD 1995 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ABDA0G-P-A-DK00000 EAR99 8504.40.9540 1 710W 6 93% 5V 12V 48V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 4.17 A 21 A 3 A 3 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse