SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input Voltage - Input (Max) DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-AAACGC-P-A-DK00000 Advanced Energy CX10S-AAACGC-P-A-DK00000 -
RFQ
ECAD 6160 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AAACGC-P-A-DK00000 EAR99 8504.40.9540 1 835W 7 93% 5V 5V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 21 A 8.3 A 3 A 3 A
6A12-N4-I5-25PPM-F-M-C Advanced Energy 6A12-N4-I5-25PPM-F-M-C 1.0000
RFQ
ECAD 3 0.00000000 Advanced Energy UltraVolt® A Bulk Active -10°C ~ 45°C ITE (Commercial) 4.75" L x 2.00" W x 1.00" H (120.7mm x 50.8mm x 25.4mm) Chassis Mount Enclosed 6A12-N4 CE, cURus 16V - ROHS3 Compliant Not Applicable 633-6A12-N4-I5-25PPM-F-M-C EAR99 8504.40.9580 1 4W 1 670µA 11V - 0 ~ 6000V - - - 6 kV -
CX10S-CB0DDH-P-A-DK00000 Advanced Energy CX10S-CB0DDH-P-A-DK00000 -
RFQ
ECAD 7083 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CB0DDH-P-A-DK00000 EAR99 8504.40.9540 1 880W 6 93% 24V 12V 48V 48V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 15 A 4.17 A 4.17 A 6 A 3 A
CX10S-CCCGHG-P-A-DK00000 Advanced Energy CX10S-CCCGHG-P-A-DK00000 -
RFQ
ECAD 3858 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CCCGHG-P-A-DK00000 EAR99 8504.40.9540 1 940W 9 93% 24V 24V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 8.3 A 3 A 3 A 6 A
CX10S-C0HGHB-P-A-DK00000 Advanced Energy CX10S-C0HGHB-P-A-DK00000 -
RFQ
ECAD 8552 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C0HGHB-P-A-DK00000 EAR99 8504.40.9540 1 700W 8 93% 24V 5V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 3 A 3 A 6 A
CX10S-GD0HHG-P-A-DK00000 Advanced Energy CX10S-GD0HHG-P-A-DK00000 -
RFQ
ECAD 1691 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GD0HHG-P-A-DK00000 EAR99 8504.40.9540 1 640W 9 93% 24V 24V 48V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 6 A 3 A 6 A
CX10S-HDHCHG-P-A-DK00000 Advanced Energy CX10S-HDHCHG-P-A-DK00000 -
RFQ
ECAD 4342 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HDHCHG-P-A-DK00000 EAR99 8504.40.9540 1 820W 10 93% 5V 24V 48V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 4.17 A 6 A 3 A 8.3 A
CX10S-AG0HAD-P-A-DK00000 Advanced Energy CX10S-AG0HAD-P-A-DK00000 -
RFQ
ECAD 3362 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AG0HAD-P-A-DK00000 EAR99 8504.40.9540 1 630W 7 93% 5V 24V 24V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 3 A 3 A 6 A 3 A 21 A
CX10S-HHDACC-P-A-DK00000 Advanced Energy CX10S-HHDACC-P-A-DK00000 -
RFQ
ECAD 9332 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HHDACC-P-A-DK00000 EAR99 8504.40.9540 1 905W 8 93% 5V 24V 5V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 6 A 3 A 4.17 A 21 A
CX10S-DBGAC0-P-A-DK00000 Advanced Energy CX10S-DBGAC0-P-A-DK00000 -
RFQ
ECAD 4992 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DBGAC0-P-A-DK00000 EAR99 8504.40.9540 1 805W 6 93% 48V 12V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 15 A 3 A 3 A 21 A 8.3 A
CX10S-CBADAB-P-A-DK00000 Advanced Energy CX10S-CBADAB-P-A-DK00000 -
RFQ
ECAD 8278 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CBADAB-P-A-DK00000 EAR99 8504.40.9540 1 970W 6 93% 24V 12V 5V 48V 5V 12V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 15 A 21 A 4.17 A 21 A 15 A
CX10S-ADBAC0-P-A-DK00000 Advanced Energy CX10S-ADBAC0-P-A-DK00000 -
RFQ
ECAD 6692 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ADBAC0-P-A-DK00000 EAR99 8504.40.9540 1 790W 5 93% 5V 48V 12V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 15 A 21 A 8.3 A
CX10S-HDBBCA-P-A-DK00000 Advanced Energy CX10S-HDBBCA-P-A-DK00000 -
RFQ
ECAD 4133 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HDBBCA-P-A-DK00000 EAR99 8504.40.9540 1 965W 7 93% 5V 24V 48V 12V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 4.17 A 15 A 15 A 8.3 A
CX10S-0GDGB0-P-A-DK00000 Advanced Energy CX10S-0GDGB0-P-A-DK00000 -
RFQ
ECAD 7719 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0GDGB0-P-A-DK00000 EAR99 8504.40.9540 1 620W 6 93% 24V 24V 48V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 3 A 3 A 15 A
CX10S-BHHGGH-P-A-DK00000 Advanced Energy CX10S-BHHGGH-P-A-DK00000 -
RFQ
ECAD 3247 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BHHGGH-P-A-DK00000 EAR99 8504.40.9540 1 720W 11 93% 12V 5V 24V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 6 A 3 A 6 A 3 A 3 A
CX10S-CGGABA-P-A-DK00000 Advanced Energy CX10S-CGGABA-P-A-DK00000 -
RFQ
ECAD 6063 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CGGABA-P-A-DK00000 EAR99 8504.40.9540 1 830W 8 93% 24V 24V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 3 A 3 A 21 A
CX10S-CB0GHC-P-A-DK00000 Advanced Energy CX10S-CB0GHC-P-A-DK00000 -
RFQ
ECAD 8326 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CB0GHC-P-A-DK00000 EAR99 8504.40.9540 1 800W 7 93% 24V 12V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 15 A 3 A 3 A 6 A 3 A
CX10S-HDGGHG-P-A-DK00000 Advanced Energy CX10S-HDGGHG-P-A-DK00000 -
RFQ
ECAD 8308 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HDGGHG-P-A-DK00000 EAR99 8504.40.9540 1 760W 11 93% 5V 24V 48V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 4.17 A 3 A 3 A 3 A
CX10S-B0GGHB-P-A-DK00000 Advanced Energy CX10S-B0GGHB-P-A-DK00000 -
RFQ
ECAD 1032 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-B0GGHB-P-A-DK00000 EAR99 8504.40.9540 1 700W 8 93% 12V 24V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 15 A 3 A 3 A 3 A 3 A 6 A
CX10S-D0DDC0-P-A-DK00000 Advanced Energy CX10S-D0DDC0-P-A-DK00000 -
RFQ
ECAD 4186 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-D0DDC0-P-A-DK00000 EAR99 8504.40.9540 1 800W 4 93% 48V 48V 48V 24V - - No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 4.17 A 8.3 A
CX10S-0DBC00-P-A-DK00000 Advanced Energy CX10S-0DBC00-P-A-DK00000 -
RFQ
ECAD 9805 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DBC00-P-A-DK00000 EAR99 8504.40.9540 1 580W 3 93% 48V 12V 24V - - - No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 15 A 8.3 A
CX10S-DCACDH-P-A-DK00000 Advanced Energy CX10S-DCACDH-P-A-DK00000 -
RFQ
ECAD 1168 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DCACDH-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 48V 24V 5V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 21 A 8.3 A 4.17 A 6 A
CX10S-HHDADA-P-A-DK00000 Advanced Energy CX10S-HHDADA-P-A-DK00000 -
RFQ
ECAD 5640 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HHDADA-P-A-DK00000 EAR99 8504.40.9540 1 810W 8 93% 5V 24V 5V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 6 A 3 A 4.17 A 21 A
CX10S-BBB0CC-P-A-DK00000 Advanced Energy CX10S-BBB0CC-P-A-DK00000 -
RFQ
ECAD 7390 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BBB0CC-P-A-DK00000 EAR99 8504.40.9540 1 940W 5 93% 12V 12V 12V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 15 A 15 A 8.3 A 8.3 A
CX10S-BAHBDA-P-A-DK00000 Advanced Energy CX10S-BAHBDA-P-A-DK00000 -
RFQ
ECAD 9376 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BAHBDA-P-A-DK00000 EAR99 8504.40.9540 1 870W 7 93% 12V 5V 5V 24V 12V 48V No 4 kV 60601-1; 60950-1; 62368-1 15 A 21 A 6 A 3 A 15 A 4.17 A
CX10S-0H000B-P-A-DK00000 Advanced Energy CX10S-0H000B-P-A-DK00000 -
RFQ
ECAD 2804 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0H000B-P-A-DK00000 EAR99 8504.40.9540 1 280W 3 93% 5V 24V 12V - - - No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 15 A
CX10S-CDGBGB-P-A-DK00000 Advanced Energy CX10S-CDGBGB-P-A-DK00000 -
RFQ
ECAD 3343 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CDGBGB-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 24V 48V 24V 24V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 4.17 A 3 A 3 A 15 A 3 A
CX10S-HABHCB-P-A-DK00000 Advanced Energy CX10S-HABHCB-P-A-DK00000 -
RFQ
ECAD 3690 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HABHCB-P-A-DK00000 EAR99 8504.40.9540 1 865W 8 93% 5V 24V 5V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 15 A 6 A 3 A
CX10S-A0DHBC-P-A-DK00000 Advanced Energy CX10S-A0DHBC-P-A-DK00000 -
RFQ
ECAD 5556 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-A0DHBC-P-A-DK00000 EAR99 8504.40.9540 1 785W 6 93% 5V 48V 5V 24V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 6 A 3 A 15 A 8.3 A
CX10S-DDACB0-P-A-DK00000 Advanced Energy CX10S-DDACB0-P-A-DK00000 -
RFQ
ECAD 2899 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DDACB0-P-A-DK00000 EAR99 8504.40.9540 1 885W 5 93% 48V 48V 5V 24V 12V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 21 A 8.3 A 15 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse