Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-GDAAHH-P-A-DK00000 Advanced Energy CX10S-GDAAHH-P-A-DK00000 -
RFQ
ECAD 5683 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GDAAHH-P-A-DK00000 EAR99 8504.40.9540 1 730W 9 93% 24V 24V 48V 5V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 21 A 21 A 6 A
CX10S-CAAGAH-P-A-DK00000 Advanced Energy CX10S-CAAGAH-P-A-DK00000 -
RFQ
ECAD 9953 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CAAGAH-P-A-DK00000 EAR99 8504.40.9540 1 735W 8 93% 24V 5V 5V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 21 A 21 A 3 A 3 A 21 A
CX10S-CGACB0-P-A-DK00000 Advanced Energy CX10S-CGACB0-P-A-DK00000 -
RFQ
ECAD 2618 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CGACB0-P-A-DK00000 EAR99 8504.40.9540 1 805W 6 93% 24V 24V 24V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 21 A 8.3 A 15 A
CX10S-HBDAGB-P-A-DK00000 Advanced Energy CX10S-HBDAGB-P-A-DK00000 -
RFQ
ECAD 5434 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HBDAGB-P-A-DK00000 EAR99 8504.40.9540 1 885W 8 93% 5V 24V 12V 48V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 15 A 4.17 A 21 A 3 A
CX10S-DBCDCB-P-A-DK00000 Advanced Energy CX10S-DBCDCB-P-A-DK00000 -
RFQ
ECAD 4976 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DBCDCB-P-A-DK00000 EAR99 8504.40.9540 1 1000W 6 93% 48V 12V 24V 48V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 15 A 8.3 A 4.17 A 8.3 A 15 A
CX10S-BGGBBD-P-A-DK00000 Advanced Energy CX10S-BGGBBD-P-A-DK00000 -
RFQ
ECAD 9446 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BGGBBD-P-A-DK00000 EAR99 8504.40.9540 1 980W 8 93% 12V 24V 24V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 3 A 3 A 3 A 3 A 15 A
CX10S-DGGDAD-P-A-DK00000 Advanced Energy CX10S-DGGDAD-P-A-DK00000 -
RFQ
ECAD 5002 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DGGDAD-P-A-DK00000 EAR99 8504.40.9540 1 945W 8 93% 48V 24V 24V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 3 A 3 A 4.17 A
CX10S-BGCHBG-P-A-DK00000 Advanced Energy CX10S-BGCHBG-P-A-DK00000 -
RFQ
ECAD 4486 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BGCHBG-P-A-DK00000 EAR99 8504.40.9540 1 900W 9 93% 12V 24V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 3 A 3 A 8.3 A 6 A 3 A
CX10S-HBBGAC-P-A-DK00000 Advanced Energy CX10S-HBBGAC-P-A-DK00000 -
RFQ
ECAD 7228 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HBBGAC-P-A-DK00000 EAR99 8504.40.9540 1 885W 8 93% 5V 24V 12V 12V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 15 A 15 A 3 A 3 A
CX10S-DCAGBD-P-A-DK00000 Advanced Energy CX10S-DCAGBD-P-A-DK00000 -
RFQ
ECAD 8106 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DCAGBD-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 48V 24V 5V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 21 A 3 A 3 A 15 A
CX10S-G0AGDA-P-A-DK00000 Advanced Energy CX10S-G0AGDA-P-A-DK00000 -
RFQ
ECAD 5589 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0AGDA-P-A-DK00000 EAR99 8504.40.9540 1 650W 7 93% 24V 24V 5V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 3 A 3 A 4.17 A
CX10S-DCG0HH-P-A-DK00000 Advanced Energy CX10S-DCG0HH-P-A-DK00000 -
RFQ
ECAD 5491 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DCG0HH-P-A-DK00000 EAR99 8504.40.9540 1 520W 8 93% 48V 24V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 3 A 3 A 6 A 3 A
CX10S-CHC0BG-P-A-DK00000 Advanced Energy CX10S-CHC0BG-P-A-DK00000 -
RFQ
ECAD 8455 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CHC0BG-P-A-DK00000 EAR99 8504.40.9540 1 800W 7 93% 24V 5V 24V 24V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 8.3 A 15 A 3 A
CX10S-C0BHCC-P-A-DK00000 Advanced Energy CX10S-C0BHCC-P-A-DK00000 -
RFQ
ECAD 1208 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C0BHCC-P-A-DK00000 EAR99 8504.40.9540 1 880W 6 93% 24V 12V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 15 A 6 A 3 A 8.3 A 8.3 A
CX10S-GHCDHC-P-A-DK00000 Advanced Energy CX10S-GHCDHC-P-A-DK00000 -
RFQ
ECAD 6575 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GHCDHC-P-A-DK00000 EAR99 8504.40.9540 1 920W 9 93% 24V 24V 5V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 8.3 A 4.17 A
CX10S-G0GDCD-P-A-DK00000 Advanced Energy CX10S-G0GDCD-P-A-DK00000 -
RFQ
ECAD 8723 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0GDCD-P-A-DK00000 EAR99 8504.40.9540 1 840W 7 93% 24V 24V 24V 24V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 4.17 A 8.3 A
CX10S-DDCBHB-P-A-DK00000 Advanced Energy CX10S-DDCBHB-P-A-DK00000 -
RFQ
ECAD 6771 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DDCBHB-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 48V 48V 24V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 8.3 A 15 A 6 A 3 A
CX10S-D0DCHA-P-A-DK00000 Advanced Energy CX10S-D0DCHA-P-A-DK00000 -
RFQ
ECAD 1776 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-D0DCHA-P-A-DK00000 EAR99 8504.40.9540 1 805W 6 93% 48V 48V 24V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 8.3 A 6 A 3 A 21 A
CX10S-CCGAHG-P-A-DK00000 Advanced Energy CX10S-CCGAHG-P-A-DK00000 -
RFQ
ECAD 7124 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CCGAHG-P-A-DK00000 EAR99 8504.40.9540 1 845W 9 93% 24V 24V 24V 24V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 3 A 3 A 21 A 6 A
CX10S-HABDDD-P-A-DK00000 Advanced Energy CX10S-HABDDD-P-A-DK00000 -
RFQ
ECAD 6889 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HABDDD-P-A-DK00000 EAR99 8504.40.9540 1 985W 7 93% 5V 24V 5V 12V 48V 48V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 15 A 4.17 A 4.17 A
CX10S-CDGCDC-P-A-DK00000 Advanced Energy CX10S-CDGCDC-P-A-DK00000 -
RFQ
ECAD 7495 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CDGCDC-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 24V 48V 24V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 4.17 A 3 A 3 A 8.3 A 4.17 A
CX10S-DBHBDD-P-A-DK00000 Advanced Energy CX10S-DBHBDD-P-A-DK00000 -
RFQ
ECAD 8803 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DBHBDD-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 48V 12V 5V 24V 12V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 15 A 6 A 3 A 15 A 4.17 A
CX10S-HDAGAB-P-A-DK00000 Advanced Energy CX10S-HDAGAB-P-A-DK00000 -
RFQ
ECAD 2763 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HDAGAB-P-A-DK00000 EAR99 8504.40.9540 1 810W 8 93% 5V 24V 48V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 4.17 A 21 A 3 A 3 A
CX10S-D0DD0B-P-A-DK00000 Advanced Energy CX10S-D0DD0B-P-A-DK00000 -
RFQ
ECAD 6596 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-D0DD0B-P-A-DK00000 EAR99 8504.40.9540 1 780W 4 93% 48V 48V 48V 12V - - No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 4.17 A 15 A
CX10S-HBABGC-P-A-DK00000 Advanced Energy CX10S-HBABGC-P-A-DK00000 -
RFQ
ECAD 5559 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HBABGC-P-A-DK00000 EAR99 8504.40.9540 1 885W 8 93% 5V 24V 12V 5V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 15 A 21 A 15 A 3 A
CX10S-DGGDAA-P-A-DK00000 Advanced Energy CX10S-DGGDAA-P-A-DK00000 -
RFQ
ECAD 5637 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DGGDAA-P-A-DK00000 EAR99 8504.40.9540 1 850W 8 93% 48V 24V 24V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 3 A 3 A 4.17 A
CX10S-CCBC0A-P-A-DK00000 Advanced Energy CX10S-CCBC0A-P-A-DK00000 -
RFQ
ECAD 4412 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CCBC0A-P-A-DK00000 EAR99 8504.40.9540 1 885W 5 93% 24V 24V 12V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 15 A 8.3 A 21 A
CX10S-DBBB0C-P-A-DK00000 Advanced Energy CX10S-DBBB0C-P-A-DK00000 -
RFQ
ECAD 2267 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DBBB0C-P-A-DK00000 EAR99 8504.40.9540 1 940W 5 93% 48V 12V 12V 12V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 15 A 15 A 15 A 8.3 A
CX10S-CHBCH0-P-A-DK00000 Advanced Energy CX10S-CHBCH0-P-A-DK00000 -
RFQ
ECAD 5435 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CHBCH0-P-A-DK00000 EAR99 8504.40.9540 1 780W 7 93% 24V 5V 24V 12V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 15 A 8.3 A 6 A
CX10S-H0A0G0-P-A-DK00000 Advanced Energy CX10S-H0A0G0-P-A-DK00000 -
RFQ
ECAD 6205 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-H0A0G0-P-A-DK00000 EAR99 8504.40.9540 1 325W 5 93% 5V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 3 A 3 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse