SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-HBCA0B-P-A-DK00000 Advanced Energy CX10S-HBCA0B-P-A-DK00000 -
RFQ
ECAD 8224 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HBCA0B-P-A-DK00000 EAR99 8504.40.9540 1 765W 6 93% 5V 24V 12V 24V 5V 12V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 15 A 8.3 A 21 A 15 A
CX10S-H0DDGC-P-A-DK00000 Advanced Energy CX10S-H0DDGC-P-A-DK00000 -
RFQ
ECAD 2671 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-H0DDGC-P-A-DK00000 EAR99 8504.40.9540 1 820W 7 93% 5V 24V 48V 48V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 4.17 A 4.17 A 3 A 3 A
CX10S-DCHCCG-P-A-DK00000 Advanced Energy CX10S-DCHCCG-P-A-DK00000 -
RFQ
ECAD 6929 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DCHCCG-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 48V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 6 A 3 A 8.3 A 8.3 A
CX10S-DGB0GD-P-A-DK00000 Advanced Energy CX10S-DGB0GD-P-A-DK00000 -
RFQ
ECAD 9872 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DGB0GD-P-A-DK00000 EAR99 8504.40.9540 1 820W 7 93% 48V 24V 24V 12V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 15 A 3 A 3 A
CX10S-CHAG0C-P-A-DK00000 Advanced Energy CX10S-CHAG0C-P-A-DK00000 -
RFQ
ECAD 5625 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CHAG0C-P-A-DK00000 EAR99 8504.40.9540 1 725W 7 93% 24V 5V 24V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 21 A 3 A 3 A
CX10S-ADBCAC-P-A-DK00000 Advanced Energy CX10S-ADBCAC-P-A-DK00000 -
RFQ
ECAD 6525 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ADBCAC-P-A-DK00000 EAR99 8504.40.9540 1 990W 6 93% 5V 48V 12V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 15 A 8.3 A 21 A 8.3 A
CX10S-D0GGC0-P-A-DK00000 Advanced Energy CX10S-D0GGC0-P-A-DK00000 -
RFQ
ECAD 6172 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-D0GGC0-P-A-DK00000 EAR99 8504.40.9540 1 640W 6 93% 48V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 3 A 3 A 8.3 A
CX10S-0C00G0-P-A-DK00000 Advanced Energy CX10S-0C00G0-P-A-DK00000 -
RFQ
ECAD 9686 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0C00G0-P-A-DK00000 EAR99 8504.40.9540 1 320W 3 93% 24V 24V 24V - - - No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A
CX10S-HAGAGC-P-A-DK00000 Advanced Energy CX10S-HAGAGC-P-A-DK00000 -
RFQ
ECAD 2917 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HAGAGC-P-A-DK00000 EAR99 8504.40.9540 1 750W 9 93% 5V 24V 5V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 3 A 3 A 21 A
CX10S-GAAH0G-P-A-DK00000 Advanced Energy CX10S-GAAH0G-P-A-DK00000 -
RFQ
ECAD 8218 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GAAH0G-P-A-DK00000 EAR99 8504.40.9540 1 550W 8 93% 24V 24V 5V 5V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 21 A 6 A 3 A
CX10S-GHBBBC-P-A-DK00000 Advanced Energy CX10S-GHBBBC-P-A-DK00000 -
RFQ
ECAD 6021 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GHBBBC-P-A-DK00000 EAR99 8504.40.9540 1 960W 8 93% 24V 24V 5V 24V 12V 12V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 15 A 15 A
CX10S-AAGHCG-P-A-DK00000 Advanced Energy CX10S-AAGHCG-P-A-DK00000 -
RFQ
ECAD 6665 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AAGHCG-P-A-DK00000 EAR99 8504.40.9540 1 750W 9 93% 5V 5V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 3 A 3 A 6 A 3 A
CX10S-HAH0DD-P-A-DK00000 Advanced Energy CX10S-HAH0DD-P-A-DK00000 -
RFQ
ECAD 3361 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HAH0DD-P-A-DK00000 EAR99 8504.40.9540 1 705W 7 93% 5V 24V 5V 5V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 6 A 3 A 4.17 A
CX10S-GDHBDH-P-A-DK00000 Advanced Energy CX10S-GDHBDH-P-A-DK00000 -
RFQ
ECAD 5651 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GDHBDH-P-A-DK00000 EAR99 8504.40.9540 1 900W 9 93% 24V 24V 48V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 6 A 3 A 15 A
CX10S-0DDGAC-P-A-DK00000 Advanced Energy CX10S-0DDGAC-P-A-DK00000 -
RFQ
ECAD 7259 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DDGAC-P-A-DK00000 EAR99 8504.40.9540 1 825W 6 93% 48V 48V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 3 A 3 A 21 A 8.3 A
CX10S-GAGDAH-P-A-DK00000 Advanced Energy CX10S-GAGDAH-P-A-DK00000 -
RFQ
ECAD 6253 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GAGDAH-P-A-DK00000 EAR99 8504.40.9540 1 750W 9 93% 24V 24V 5V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 3 A 3 A 4.17 A
CX10S-HCDHBC-P-A-DK00000 Advanced Energy CX10S-HCDHBC-P-A-DK00000 -
RFQ
ECAD 9954 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HCDHBC-P-A-DK00000 EAR99 8504.40.9540 1 980W 8 93% 5V 24V 24V 48V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 8.3 A 4.17 A 6 A 3 A
CX10S-0BGDDC-P-A-DK00000 Advanced Energy CX10S-0BGDDC-P-A-DK00000 -
RFQ
ECAD 6134 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0BGDDC-P-A-DK00000 EAR99 8504.40.9540 1 900W 6 93% 12V 24V 24V 48V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 3 A 3 A 4.17 A 4.17 A 8.3 A
CX10S-HACADA-P-A-DK00000 Advanced Energy CX10S-HACADA-P-A-DK00000 -
RFQ
ECAD 1632 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HACADA-P-A-DK00000 EAR99 8504.40.9540 1 815W 7 93% 5V 24V 5V 24V 5V 48V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 8.3 A 21 A 4.17 A
CX10S-CH0BBA-P-A-DK00000 Advanced Energy CX10S-CH0BBA-P-A-DK00000 -
RFQ
ECAD 8956 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CH0BBA-P-A-DK00000 EAR99 8504.40.9540 1 765W 6 93% 24V 5V 24V 12V 12V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 15 A 15 A 21 A
CX10S-H00GAH-P-A-DK00000 Advanced Energy CX10S-H00GAH-P-A-DK00000 -
RFQ
ECAD 8670 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-H00GAH-P-A-DK00000 EAR99 8504.40.9540 1 425W 7 93% 5V 24V 24V 24V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 3 A 3 A 21 A 6 A
CX10S-ACHBGH-P-A-DK00000 Advanced Energy CX10S-ACHBGH-P-A-DK00000 -
RFQ
ECAD 7391 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ACHBGH-P-A-DK00000 EAR99 8504.40.9540 1 805W 9 93% 5V 24V 5V 24V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 6 A 3 A 15 A 3 A
CX10S-0A0HDA-P-A-DK00000 Advanced Energy CX10S-0A0HDA-P-A-DK00000 -
RFQ
ECAD 6240 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0A0HDA-P-A-DK00000 EAR99 8504.40.9540 1 510W 5 93% 5V 5V 24V 48V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 6 A 3 A 4.17 A 21 A
CX10S-GHGHG0-P-A-DK00000 Advanced Energy CX10S-GHGHG0-P-A-DK00000 -
RFQ
ECAD 5937 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GHGHG0-P-A-DK00000 EAR99 8504.40.9540 1 560W 10 93% 24V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 3 A 3 A
CX10S-00BBBB-P-A-DK00000 Advanced Energy CX10S-00BBBB-P-A-DK00000 -
RFQ
ECAD 1387 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00BBBB-P-A-DK00000 EAR99 8504.40.9540 1 720W 4 93% 12V 12V 12V 12V - - No 4 kV 60601-1; 60950-1; 62368-1 15 A 15 A 15 A 15 A
CX10S-HDGABB-P-A-DK00000 Advanced Energy CX10S-HDGABB-P-A-DK00000 -
RFQ
ECAD 1193 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HDGABB-P-A-DK00000 EAR99 8504.40.9540 1 885W 8 93% 5V 24V 48V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 4.17 A 3 A 3 A 21 A
CX10S-G0BDD0-P-A-DK00000 Advanced Energy CX10S-G0BDD0-P-A-DK00000 -
RFQ
ECAD 5700 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0BDD0-P-A-DK00000 EAR99 8504.40.9540 1 700W 5 93% 24V 24V 12V 48V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 4.17 A 4.17 A
CX10S-HADG0C-P-A-DK00000 Advanced Energy CX10S-HADG0C-P-A-DK00000 -
RFQ
ECAD 5669 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HADG0C-P-A-DK00000 EAR99 8504.40.9540 1 725W 7 93% 5V 24V 5V 48V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 4.17 A 3 A 3 A
CX10S-GBC0BA-P-A-DK00000 Advanced Energy CX10S-GBC0BA-P-A-DK00000 -
RFQ
ECAD 7702 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GBC0BA-P-A-DK00000 EAR99 8504.40.9540 1 785W 6 93% 24V 24V 12V 24V 12V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 8.3 A 15 A 21 A
CX10S-GDHBDG-P-A-DK00000 Advanced Energy CX10S-GDHBDG-P-A-DK00000 -
RFQ
ECAD 6590 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GDHBDG-P-A-DK00000 EAR99 8504.40.9540 1 920W 9 93% 24V 24V 48V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 6 A 3 A 15 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse