SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-DAGGH0-P-A-DK00000 Advanced Energy CX10S-DAGGH0-P-A-DK00000 -
RFQ
ECAD 5239 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DAGGH0-P-A-DK00000 EAR99 8504.40.9540 1 645W 8 93% 48V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 3 A 3 A 3 A 3 A
CX10S-GHGGDG-P-A-DK00000 Advanced Energy CX10S-GHGGDG-P-A-DK00000 -
RFQ
ECAD 6666 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GHGGDG-P-A-DK00000 EAR99 8504.40.9540 1 780W 11 93% 24V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 3 A 3 A
CX10S-0C00CD-P-A-DK00000 Advanced Energy CX10S-0C00CD-P-A-DK00000 -
RFQ
ECAD 5036 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0C00CD-P-A-DK00000 EAR99 8504.40.9540 1 600W 3 93% 24V 24V 48V - - - No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 4.17 A
CX10S-GDHBDA-P-A-DK00000 Advanced Energy CX10S-GDHBDA-P-A-DK00000 -
RFQ
ECAD 7806 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GDHBDA-P-A-DK00000 EAR99 8504.40.9540 1 905W 8 93% 24V 24V 48V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 6 A 3 A 15 A
CX10S-0HBB00-P-A-DK00000 Advanced Energy CX10S-0HBB00-P-A-DK00000 -
RFQ
ECAD 6415 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0HBB00-P-A-DK00000 EAR99 8504.40.9540 1 460W 4 93% 5V 24V 12V 12V - - No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 15 A 15 A
CX10S-DGD0BH-P-A-DK00000 Advanced Energy CX10S-DGD0BH-P-A-DK00000 -
RFQ
ECAD 4695 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DGD0BH-P-A-DK00000 EAR99 8504.40.9540 1 800W 7 93% 48V 24V 24V 48V 12V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 4.17 A 15 A 6 A
CX10S-DCGH00-P-A-DK00000 Advanced Energy CX10S-DCGH00-P-A-DK00000 -
RFQ
ECAD 3902 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DCGH00-P-A-DK00000 EAR99 8504.40.9540 1 620W 6 93% 48V 24V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 3 A 3 A 6 A 3 A
CX10S-GDA0GD-P-A-DK00000 Advanced Energy CX10S-GDA0GD-P-A-DK00000 -
RFQ
ECAD 2012 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GDA0GD-P-A-DK00000 EAR99 8504.40.9540 1 745W 7 93% 24V 24V 48V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 21 A 3 A 3 A
CX10S-0DH0HH-P-A-DK00000 Advanced Energy CX10S-0DH0HH-P-A-DK00000 -
RFQ
ECAD 4200 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DH0HH-P-A-DK00000 EAR99 8504.40.9540 1 500W 7 93% 48V 5V 24V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 6 A 3 A 6 A
CX10S-CHGHDB-P-A-DK00000 Advanced Energy CX10S-CHGHDB-P-A-DK00000 -
RFQ
ECAD 1503 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CHGHDB-P-A-DK00000 EAR99 8504.40.9540 1 900W 9 93% 24V 5V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 3 A 3 A 6 A
CX10S-00DHCH-P-A-DK00000 Advanced Energy CX10S-00DHCH-P-A-DK00000 -
RFQ
ECAD 9390 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00DHCH-P-A-DK00000 EAR99 8504.40.9540 1 600W 6 93% 48V 5V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 8.3 A 6 A 3 A
CX10S-DDDDAB-P-A-DK00000 Advanced Energy CX10S-DDDDAB-P-A-DK00000 -
RFQ
ECAD 9451 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DDDDAB-P-A-DK00000 EAR99 8504.40.9540 1 1000W 6 93% 48V 48V 48V 48V 5V 12V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 4.17 A 4.17 A 21 A 15 A
CX10S-HA0B0A-P-A-DK00000 Advanced Energy CX10S-HA0B0A-P-A-DK00000 -
RFQ
ECAD 7461 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HA0B0A-P-A-DK00000 EAR99 8504.40.9540 1 490W 5 93% 5V 24V 5V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 15 A 21 A
CX10S-CHGHDA-P-A-DK00000 Advanced Energy CX10S-CHGHDA-P-A-DK00000 -
RFQ
ECAD 4564 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CHGHDA-P-A-DK00000 EAR99 8504.40.9540 1 825W 9 93% 24V 5V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 3 A 3 A 6 A
CX10S-GCGADC-P-A-DK00000 Advanced Energy CX10S-GCGADC-P-A-DK00000 -
RFQ
ECAD 8527 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GCGADC-P-A-DK00000 EAR99 8504.40.9540 1 945W 8 93% 24V 24V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 3 A 3 A 21 A
CX10S-HGA0BC-P-A-DK00000 Advanced Energy CX10S-HGA0BC-P-A-DK00000 -
RFQ
ECAD 3263 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HGA0BC-P-A-DK00000 EAR99 8504.40.9540 1 705W 7 93% 5V 24V 24V 24V 5V 12V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 3 A 3 A 21 A 15 A
CX10S-AGHHGB-P-A-DK00000 Advanced Energy CX10S-AGHHGB-P-A-DK00000 -
RFQ
ECAD 3063 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AGHHGB-P-A-DK00000 EAR99 8504.40.9540 1 725W 10 93% 5V 24V 24V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 3 A 3 A 6 A 3 A 6 A
CX10S-HGA0DA-P-A-DK00000 Advanced Energy CX10S-HGA0DA-P-A-DK00000 -
RFQ
ECAD 6090 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HGA0DA-P-A-DK00000 EAR99 8504.40.9540 1 630W 7 93% 5V 24V 24V 24V 5V 48V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 3 A 3 A 21 A 4.17 A
CX10S-DC00GD-P-A-DK00000 Advanced Energy CX10S-DC00GD-P-A-DK00000 -
RFQ
ECAD 7379 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DC00GD-P-A-DK00000 EAR99 8504.40.9540 1 720W 5 93% 48V 24V 24V 24V 48V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 3 A 3 A 4.17 A
CX10S-HD0HBG-P-A-DK00000 Advanced Energy CX10S-HD0HBG-P-A-DK00000 -
RFQ
ECAD 8702 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HD0HBG-P-A-DK00000 EAR99 8504.40.9540 1 700W 8 93% 5V 24V 48V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 4.17 A 6 A 3 A 15 A
CX10S-0DAGGA-P-A-DK00000 Advanced Energy CX10S-0DAGGA-P-A-DK00000 -
RFQ
ECAD 1725 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DAGGA-P-A-DK00000 EAR99 8504.40.9540 1 650W 7 93% 48V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 3 A 3 A 3 A 3 A
CX10S-GHHABG-P-A-DK00000 Advanced Energy CX10S-GHHABG-P-A-DK00000 -
RFQ
ECAD 4215 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GHHABG-P-A-DK00000 EAR99 8504.40.9540 1 725W 10 93% 24V 24V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 6 A 3 A
CX10S-H00000-P-A-DK00000 Advanced Energy CX10S-H00000-P-A-DK00000 -
RFQ
ECAD 3312 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-H00000-P-A-DK00000 EAR99 8504.40.9540 1 100W 2 93% 5V 24V - - - - No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A
CX10S-HAH0CA-P-A-DK00000 Advanced Energy CX10S-HAH0CA-P-A-DK00000 -
RFQ
ECAD 4698 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HAH0CA-P-A-DK00000 EAR99 8504.40.9540 1 610W 7 93% 5V 24V 5V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 6 A 3 A 8.3 A
CX10S-G0DCCB-P-A-DK00000 Advanced Energy CX10S-G0DCCB-P-A-DK00000 -
RFQ
ECAD 6476 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0DCCB-P-A-DK00000 EAR99 8504.40.9540 1 900W 6 93% 24V 24V 48V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 8.3 A 8.3 A 15 A
CX10S-CHDCHG-P-A-DK00000 Advanced Energy CX10S-CHDCHG-P-A-DK00000 -
RFQ
ECAD 3538 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CHDCHG-P-A-DK00000 EAR99 8504.40.9540 1 920W 9 93% 24V 5V 24V 48V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 4.17 A 8.3 A 6 A
CX10S-HCHBHC-P-A-DK00000 Advanced Energy CX10S-HCHBHC-P-A-DK00000 -
RFQ
ECAD 5690 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HCHBHC-P-A-DK00000 EAR99 8504.40.9540 1 880W 9 93% 5V 24V 24V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 8.3 A 6 A 3 A 15 A
CX10S-GDHBGB-P-A-DK00000 Advanced Energy CX10S-GDHBGB-P-A-DK00000 -
RFQ
ECAD 4417 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GDHBGB-P-A-DK00000 EAR99 8504.40.9540 1 900W 9 93% 24V 24V 48V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 6 A 3 A 15 A
CX10S-HBDGAH-P-A-DK00000 Advanced Energy CX10S-HBDGAH-P-A-DK00000 -
RFQ
ECAD 8041 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HBDGAH-P-A-DK00000 EAR99 8504.40.9540 1 805W 9 93% 5V 24V 12V 48V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 15 A 4.17 A 3 A 3 A
CX10S-GBACGH-P-A-DK00000 Advanced Energy CX10S-GBACGH-P-A-DK00000 -
RFQ
ECAD 7047 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GBACGH-P-A-DK00000 EAR99 8504.40.9540 1 825W 9 93% 24V 24V 12V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 21 A 8.3 A 3 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse