SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Base Product Number Approval Agency Voltage - Input (Max) DataSheet RoHS Status Moisture Sensitivity Level (MSL) ECCN HTSUS Standard Package Power (Watts) Number of Outputs Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Standard Number
1010816CH Integrated Power Designs 1010816CH 115.4300
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC2-70 (70W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.79" L x 2.62" W x 1.48" H (121.6mm x 66.5mm x 37.6mm) Chassis Mount Chassis 1010816 CE, cURus, TUV, UKCA 36V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 70W 1 1.5A 18V 78% 48V - - - 60601-1; 62368-1
1010787 Integrated Power Designs 1010787 108.7600
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-70 (70W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.50" L x 2.50" W x 1.22" H (114.3mm x 63.5mm x 31.0mm) Chassis Mount Open Frame CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 35W 1 14A 36V 78% 2.5V - - - 60601-1; 62368-1
1010649CHCO Integrated Power Designs 1010649CHCO 159.5000
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-110 (110W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 5.25" L x 3.12" W x 1.48" H (133.4mm x 79.2mm x 37.6mm) Chassis Mount Enclosed 1010649 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 110W 2 10A, 3A 36V 82% 5V 24V - - 60601-1; 62368-1
1010813 Integrated Power Designs 1010813 108.7600
RFQ
ECAD 183 0.00000000 Integrated Power Designs DC2-70 (70W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.50" L x 2.50" W x 1.22" H (114.3mm x 63.5mm x 31.0mm) Chassis Mount Open Frame CE, cURus, TUV, UKCA 36V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 70W 1 4.7A 18V 78% 15V - - - 60601-1; 62368-1
1010645CH Integrated Power Designs 1010645CH 143.7100
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-110 (110W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 5.25" L x 3.12" W x 1.48" H (133.4mm x 79.2mm x 37.6mm) Chassis Mount Chassis 1010645 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 110W 1 3.9A 36V 82% 28V - - - 60601-1; 62368-1
1010662CH Integrated Power Designs 1010662CH 172.1900
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC2-150 (150W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) Chassis Mount Chassis 1010662 CE, cURus, TUV, UKCA 36V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 99W 1 30A 18V 82% 3.3V - - - 60601-1; 62368-1
1010664CHCO Integrated Power Designs 1010664CHCO 178.8600
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC2-150 (150W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) Chassis Mount Enclosed 1010664 CE, cURus, TUV, UKCA 36V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 150W 1 12.5A 18V 82% 12V - - - 60601-1; 62368-1
1011524 Integrated Power Designs 1011524 105.8700
RFQ
ECAD 5 0.00000000 Integrated Power Designs DC1-80 (80W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.50" L x 2.50" W x 1.17" H (114.3mm x 63.5mm x 29.7mm) Chassis Mount Open Frame CE, cURus, TUV, UKCA 18V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 80W 1 5.3A 9V 82% 15V - - - 60601-1; 62368-1
1010634CHCO Integrated Power Designs 1010634CHCO 187.9100
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC2-110 (110W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 5.25" L x 3.12" W x 1.48" H (133.4mm x 79.2mm x 37.6mm) Chassis Mount Enclosed 1010634 CE, cURus, TUV, UKCA 36V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 110W 4 10A, 6A, 2A, 2A 18V 82% 5V 3.3V 15V -15V 60601-1; 62368-1
1010655CHCO Integrated Power Designs 1010655CHCO 187.9100
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-110 (110W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 5.25" L x 3.12" W x 1.48" H (133.4mm x 79.2mm x 37.6mm) Chassis Mount Enclosed 1010655 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 110W 4 10A, 6A, 2A, 2A 36V 82% 5V 3.3V 12V -12V 60601-1; 62368-1
1010729 Integrated Power Designs 1010729 227.5600
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-185 (185W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 7.00" L x 4.25" W x 1.31" H (177.8mm x 107.9mm x 33.3mm) Chassis Mount Open Frame CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 116W 2 20A, 10A 36V 84% 3.3V 5V - - 60601-1; 62368-1
1010799 Integrated Power Designs 1010799 118.7900
RFQ
ECAD 10 0.00000000 Integrated Power Designs DC2-70 (70W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.50" L x 2.50" W x 1.22" H (114.3mm x 63.5mm x 31.0mm) Chassis Mount Open Frame CE, cURus, TUV, UKCA 36V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 70W 4 6A, 5A, 2A, 2A 18V 78% 5V -5V 15V -15V 60601-1; 62368-1
1010803CHCO Integrated Power Designs 1010803CHCO 129.8400
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC2-70 (70W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.79" L x 2.62" W x 1.48" H (121.6mm x 66.5mm x 37.6mm) Chassis Mount Enclosed 1010803 CE, cURus, TUV, UKCA 36V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 70W 3 6A, 2A, 2A 18V 78% 5V 15V - -15V 60601-1; 62368-1
1010666CHCO Integrated Power Designs 1010666CHCO 178.8600
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC2-150 (150W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) Chassis Mount Enclosed 1010666 CE, cURus, TUV, UKCA 36V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 150W 1 6.3A 18V 82% 24V - - - 60601-1; 62368-1
1011539CH Integrated Power Designs 1011539CH 120.8200
RFQ
ECAD 5837 0.00000000 Integrated Power Designs DC1-80 (80W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.70" L x 2.70" W x 1.48" H (119.4mm x 68.9mm x 37.6mm) Chassis Mount Chassis 1011539 CE, cURus, TUV, UKCA 18V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 80W 4 6A, 2A, 2A, 2A 9V 82% 5V 24V 12V -12V 60601-1; 62368-1
1010686 Integrated Power Designs 1010686 165.5200
RFQ
ECAD 104 0.00000000 Integrated Power Designs DC4-150 (150W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 6.00" L x 3.83" W x 1.32" H (152.4mm x 97.3mm x 33.5mm) Chassis Mount Open Frame CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 150W 1 12.5A 36V 82% 12V - - - 60601-1; 62368-1
1010704CHCO Integrated Power Designs 1010704CHCO 225.9800
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-150 (150W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) Chassis Mount Enclosed 1010704 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 150W 4 15A, 3A, 2A, 2A 36V 82% 5V 24V 15V -15V 60601-1; 62368-1
1010688CHCO Integrated Power Designs 1010688CHCO 178.8600
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-150 (150W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) Chassis Mount Enclosed 1010688 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 150W 1 6.3A 36V 82% 24V - - - 60601-1; 62368-1
1010794CHCO Integrated Power Designs 1010794CHCO 122.1000
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-70 (70W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.79" L x 2.62" W x 1.48" H (121.6mm x 66.5mm x 37.6mm) Chassis Mount Enclosed 1010794 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 70W 2 1.5A 36V 78% 48V - - - 60601-1; 62368-1
1010811CH Integrated Power Designs 1010811CH 115.4300
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC2-70 (70W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.79" L x 2.62" W x 1.48" H (121.6mm x 66.5mm x 37.6mm) Chassis Mount Chassis 1010811 CE, cURus, TUV, UKCA 36V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 70W 1 14A 18V 78% 5V - - - 60601-1; 62368-1
1010686CH Integrated Power Designs 1010686CH 172.1900
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-150 (150W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) Chassis Mount Chassis 1010686 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 150W 1 12.5A 36V 82% 12V - - - 60601-1; 62368-1
1010736CH Integrated Power Designs 1010736CH 206.0700
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-185 (185W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 7.23" L x 4.36" W x 1.74" H (183.6mm x 110.7mm x 44.2mm) Chassis Mount Chassis 1010736 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 185W 1 37A 36V 84% 5V - - - 60601-1; 62368-1
1010638 Integrated Power Designs 1010638 174.5700
RFQ
ECAD 9 0.00000000 Integrated Power Designs DC2-110 (110W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 5.00" L x 3.00" W x 1.32" H (127.0mm x 76.2mm x 33.5mm) Chassis Mount Open Frame CE, cURus, TUV, UKCA 36V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 110W 4 10A, 2A, 2A, 2A 18V 82% 5V 24V 15V -15V 60601-1; 62368-1
1010752CH Integrated Power Designs 1010752CH 251.1400
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC2-185 (185W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 7.23" L x 4.36" W x 1.74" H (183.6mm x 110.7mm x 44.2mm) Chassis Mount Chassis 1010752 CE, cURus, TUV, UKCA 36V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 185W 4 20A, 3A, 2A, 2A 18V 84% 5V 24V 15V -15V 60601-1; 62368-1
1010721CH Integrated Power Designs 1010721CH 251.1400
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-185 (185W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 7.23" L x 4.36" W x 1.74" H (183.6mm x 110.7mm x 44.2mm) Chassis Mount Chassis 1010721 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 181W 4 20A, 10A, 2A, 2A 36V 84% 5V 3.3V 12V -12V 60601-1; 62368-1
1011530 Integrated Power Designs 1011530 111.6500
RFQ
ECAD 1 0.00000000 Integrated Power Designs DC1-80 (80W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.50" L x 2.50" W x 1.17" H (114.3mm x 63.5mm x 29.7mm) Chassis Mount Open Frame CE, cURus, TUV, UKCA 18V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 80W 2 6A, 2A 9V 82% 5V 24V - - 60601-1; 62368-1
1010639CHCO Integrated Power Designs 1010639CHCO 150.3800
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-110 (110W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 5.25" L x 3.12" W x 1.48" H (133.4mm x 79.2mm x 37.6mm) Chassis Mount Enclosed 1010639 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 55W 1 22A 36V 82% 2.5V - - - 60601-1; 62368-1
1010728CHCO Integrated Power Designs 1010728CHCO 254.9900
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-185 (185W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 7.23" L x 4.36" W x 1.74" H (183.6mm x 110.7mm x 44.2mm) Chassis Mount Enclosed 1010728 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 185W 3 20A, 4A, 3A 36V 84% 5V 15V - -15V 60601-1; 62368-1
1010700CHCO Integrated Power Designs 1010700CHCO 225.9800
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-150 (150W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) Chassis Mount Enclosed 1010700 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 150W 4 15A, 8A, 2A, 2A 36V 82% 5V 3.3V 15V -15V 60601-1; 62368-1
1010736CHCO Integrated Power Designs 1010736CHCO 212.7400
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-185 (185W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 7.23" L x 4.36" W x 1.74" H (183.6mm x 110.7mm x 44.2mm) Chassis Mount Enclosed 1010736 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 185W 1 37A 36V 84% 5V - - - 60601-1; 62368-1
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse