Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NMP1K2-#EEC#E-00 | 641.2200 | 6562 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 900W | 4 | 88.5% | 12V | 12V | 5V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 36 A | 20 A | |||||
NMP1K2-#EEC#K-00 | 641.2200 | 9689 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 900W | 4 | 88.5% | 12V | 12V | 5V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 36 A | 5 A | |||||
NMP1K2-#EECCC-00 | 728.6700 | 6353 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1020W | 5 | 88.5% | 12V | 12V | 5V | 5V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 36 A | 36 A | 36 A | |||
NMP1K2-#EECCH-00 | 728.6700 | 8966 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 12V | 12V | 5V | 5V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 36 A | 36 A | 10 A | |||
NMP1K2-#EECEE-00 | 728.6700 | 2637 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 12V | 12V | 5V | 12V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 36 A | 20 A | 20 A | |||
NMP1K2-#EECHK-00 | 728.6700 | 4747 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 12V | 12V | 5V | 24V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 36 A | 10 A | 5 A | |||
NMP1K2-#EECKC-00 | 694.3000 | 7113 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 12V | 12V | 5V | 48V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 36 A | 5 A | 36 A | |||
NMP1K2-#EECKE-00 | 728.6700 | 7868 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 12V | 12V | 5V | 48V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 36 A | 5 A | 20 A | |||
NMP1K2-#EECKK-00 | 728.6700 | 5416 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 12V | 12V | 5V | 48V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 36 A | 5 A | 5 A | |||
NMP1K2-#EEE#E-00 | 641.2200 | 9396 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 960W | 4 | 88.5% | 12V | 12V | 12V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 20 A | 20 A | |||||
NMP1K2-#EEE#H-00 | 641.2200 | 7467 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 960W | 4 | 88.5% | 12V | 12V | 12V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 20 A | 10 A | |||||
NMP1K2-#EEECC-00 | 694.3000 | 3861 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 12V | 12V | 12V | 5V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 20 A | 36 A | 36 A | |||
NMP1K2-#EEEE#-00 | 641.2200 | 1082 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 960W | 4 | 88.5% | 12V | 12V | 12V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 20 A | 20 A | |||||
NMP1K2-#EEEEC-00 | 728.6700 | 9422 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 12V | 12V | 12V | 12V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 20 A | 20 A | 36 A | |||
NMP1K2-#EEEEK-00 | 728.6700 | 7092 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 12V | 12V | 12V | 12V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 20 A | 20 A | 5 A | |||
NMP1K2-#EEEH#-00 | 641.2200 | 3043 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 960W | 4 | 88.5% | 12V | 12V | 12V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 20 A | 10 A | |||||
NMP1K2-#EEEHC-00 | 728.6700 | 1083 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 12V | 12V | 12V | 24V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 20 A | 10 A | 36 A | |||
NMP1K2-#EEEHE-00 | 728.6700 | 9562 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 12V | 12V | 12V | 24V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 20 A | 10 A | 20 A | |||
NMP1K2-#EEEHK-00 | 728.6700 | 4753 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 12V | 12V | 12V | 24V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 20 A | 10 A | 5 A | |||
NMP1K2-#EEEK#-00 | 641.2200 | 5221 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 960W | 4 | 88.5% | 12V | 12V | 12V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 20 A | 5 A | |||||
NMP1K2-#EEEKE-00 | 728.6700 | 4219 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 12V | 12V | 12V | 48V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 20 A | 5 A | 20 A | |||
NMP1K2-#EEH#E-00 | 641.2200 | 8416 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 960W | 4 | 88.5% | 12V | 12V | 24V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 10 A | 20 A | |||||
NMP1K2-#EEH#H-00 | 641.2200 | 4231 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 960W | 4 | 88.5% | 12V | 12V | 24V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 10 A | 10 A | |||||
NMP1K2-#EEH#K-00 | 641.2200 | 5717 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 960W | 4 | 88.5% | 12V | 12V | 24V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 10 A | 5 A | |||||
NMP1K2-#EEHCC-00 | 728.6700 | 4110 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 12V | 12V | 24V | 5V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 10 A | 36 A | 36 A | |||
NMP1K2-#EEHCE-00 | 728.6700 | 4173 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 12V | 12V | 24V | 5V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 10 A | 36 A | 20 A | |||
NMP1K2-#EEHCH-00 | 728.6700 | 8819 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 12V | 12V | 24V | 5V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 10 A | 36 A | 10 A | |||
NMP1K2-#EEHCK-00 | 728.6700 | 1444 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 12V | 12V | 24V | 5V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 10 A | 36 A | 5 A | |||
NMP1K2-#EEHH#-00 | 641.2200 | 7295 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 960W | 4 | 88.5% | 12V | 12V | 24V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 10 A | 10 A | |||||
NMP1K2-#EEHKH-00 | 728.6700 | 9386 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 12V | 12V | 24V | 48V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 10 A | 5 A | 10 A |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse