Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NMP1K2-KE#EKK-05 | 698.9800 | 9273 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 4 | 88.5% | 48V | 12V | 12V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 20 A | 10 A | ||||||
NMP1K2-KE#KEE-05 | 733.5900 | 1233 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 4 | 88.5% | 48V | 12V | 48V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 5 A | 40 A | ||||||
NMP1K2-KE#KHH-05 | 733.5900 | 3806 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 4 | 88.5% | 48V | 12V | 48V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 5 A | 20 A | ||||||
NMP1K2-KEC#HH-05 | 733.5900 | 4859 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 4 | 88.5% | 48V | 12V | 5V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 36 A | 20 A | ||||||
NMP1K2-KECCHH-05 | 821.0300 | 6648 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 5V | 5V | 24V | 24V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 36 A | 36 A | 10 A | 10 A | |||
NMP1K2-KECHCC-05 | 821.0300 | 9658 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 5V | 24V | 5V | 5V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 36 A | 10 A | 36 A | 36 A | |||
NMP1K2-KECKHH-05 | 782.3100 | 7851 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 5V | 48V | 24V | 24V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 36 A | 5 A | 10 A | 10 A | |||
NMP1K2-KECKKK-05 | 821.0300 | 4878 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 5V | 48V | 48V | 48V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 36 A | 5 A | 5 A | 5 A | |||
NMP1K2-KEE#EE-05 | 733.5900 | 2185 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 4 | 88.5% | 48V | 12V | 12V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 20 A | 40 A | ||||||
NMP1K2-KEECHH-05 | 782.3100 | 6663 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 12V | 5V | 24V | 24V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 20 A | 36 A | 10 A | 10 A | |||
NMP1K2-KEEHCC-05 | 821.0300 | 4154 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 12V | 24V | 5V | 5V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 20 A | 10 A | 36 A | 36 A | |||
NMP1K2-KEEHEE-05 | 821.0300 | 5674 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 12V | 24V | 12V | 12V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 20 A | 10 A | 20 A | 20 A | |||
NMP1K2-KEEKKK-05 | 821.0300 | 6062 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 12V | 48V | 48V | 48V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 20 A | 5 A | 5 A | 5 A | |||
NMP1K2-KEHCEE-05 | 821.0300 | 4209 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 24V | 5V | 12V | 12V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 10 A | 36 A | 20 A | 20 A | |||
NMP1K2-KEHCKK-05 | 821.0300 | 9044 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 24V | 5V | 48V | 48V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 10 A | 36 A | 5 A | 5 A | |||
NMP1K2-KEHEKK-05 | 821.0300 | 4977 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 24V | 12V | 48V | 48V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 10 A | 20 A | 5 A | 5 A | |||
NMP1K2-KEHHCC-05 | 821.0300 | 4721 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 24V | 24V | 5V | 5V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 10 A | 10 A | 36 A | 36 A | |||
NMP1K2-KEK#EE-05 | 733.5900 | 7562 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 4 | 88.5% | 48V | 12V | 48V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 5 A | 40 A | ||||||
NMP1K2-KEK#HH-05 | 733.5900 | 3821 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 4 | 88.5% | 48V | 12V | 48V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 5 A | 20 A | ||||||
NMP1K2-KEKCCC-05 | 821.0300 | 7465 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 48V | 5V | 5V | 5V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 5 A | 36 A | 36 A | 36 A | |||
NMP1K2-KEKCHH-05 | 821.0300 | 7272 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 48V | 5V | 24V | 24V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 5 A | 36 A | 10 A | 10 A | |||
NMP1K2-KEKEHH-05 | 821.0300 | 5733 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 48V | 12V | 24V | 24V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 5 A | 20 A | 10 A | 10 A | |||
NMP1K2-KEKHCC-05 | 821.0300 | 6021 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 48V | 24V | 5V | 5V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 5 A | 10 A | 36 A | 36 A | |||
NMP1K2-KEKHHH-05 | 821.0300 | 8179 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 48V | 24V | 24V | 24V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 5 A | 10 A | 10 A | 10 A | |||
NMP1K2-KEKHKK-05 | 782.3100 | 9765 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 48V | 24V | 48V | 48V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 5 A | 10 A | 5 A | 5 A | |||
NMP1K2-KEKKCC-05 | 821.0300 | 2048 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 48V | 48V | 5V | 5V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 5 A | 5 A | 36 A | 36 A | |||
NMP1K2-KEKKHH-05 | 821.0300 | 8349 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 48V | 48V | 24V | 24V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 5 A | 5 A | 10 A | 10 A | |||
NMP1K2-KEKKKK-05 | 821.0300 | 9862 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 48V | 48V | 48V | 48V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 5 A | 5 A | 5 A | 5 A | |||
NMP1K2-KH##EE-05 | 615.6600 | 5885 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 960W | 3 | 88.5% | 48V | 24V | 12V | - | - | - | 4 kV | 60601-1; 62368-1 | 5 A | 10 A | 40 A | |||||||
NMP1K2-KH#CCC-05 | 733.5900 | 3535 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1020W | 4 | 88.5% | 48V | 24V | 5V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 5 A | 10 A | 36 A | 72 A |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse