SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Input Type Approval Agency Voltage - Input Voltage - Input (Max) DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Current - Output (Max) Voltage - Input (Min) Efficiency AC Voltage - Input Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required DC Voltage - Input (Min) DC Voltage - Input (Max) Voltage - Isolation Standard Number Current - Output 1
LDC120-48P Bel Power Solutions LDC120-48P 145.2000
RFQ
ECAD 34 0.00000000 Bel Power Solutions LDC120 (120W) Bulk Obsolete -35°C ~ 70°C (With Derating) ITE (Commercial) 4.09" L x 1.38" W x 4.06" H (104.0mm x 35.0mm x 103.0mm) Adjustable Output, IP20, Load Sharing, PFC, Universal Input LDC120 AC or DC - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.6007 15 120W 1 2.5A 89% 90 ~ 264 VAC 48V - - - - - - 110V 345V 4.2 kV
TET2000-12-086RA Bel Power Solutions TET2000-12-086RA 788.2400
RFQ
ECAD 31 0.00000000 Bel Power Solutions TET2000 (2100W) Bulk Active 0°C ~ 50°C ITE (Commercial) 7.68" L x 3.39" W x 1.57" H (195.0mm x 86.0mm x 40.0mm) Rack Mount Front End Hot Swappable, I²C Interface, Load Sharing, PFC, PMBus™, Remote On/Off, Remote Sensing, Standby Output, Universal input CE 90 ~ 264 VAC, 180 ~ 300 VDC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9540 1 2028W 1 95.3% 12V - - - - - 4.3 kV 169 A
SFP450-S149G Bel Power Solutions SFP450-S149G -
RFQ
ECAD 3994 0.00000000 Bel Power Solutions - Box Obsolete - Not Applicable REACH Unaffected 179-SFP450-S149G EAR99 8504.40.9530 1
BM1301-9RG Bel Power Solutions BM1301-9RG 779.1000
RFQ
ECAD 5 0.00000000 Bel Power Solutions * Bulk Active - ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9580 6
FLS250-1012 Bel Power Solutions FLS250-1012 222.5200
RFQ
ECAD 24 0.00000000 Bel Power Solutions FLS250 (250W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 4.50" L x 2.50" W x 1.50" H (114.3mm x 63.5mm x 38.1mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Remote On/Off, Standby Output, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9530 24 250W (350W Forced Air) 1 94% 12V - - - - - - 4 kV 62368-1 16.6 A
MFLS250-1324 Bel Power Solutions MFLS250-1324 247.0100
RFQ
ECAD 24 0.00000000 Bel Power Solutions MFLS250 (250W) Box Active -40°C ~ 70°C (With Derating) Medical 4.50" L x 2.50" W x 1.58" H (114.3mm x 63.5mm x 40.1mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-MFLS250-1324 EAR99 8504.40.9530 24 250W (348W Forced Air) 1 94% 24V - - - - - - 4.38 kV 60601-1 14.5 A
MFLS250-1348 Bel Power Solutions MFLS250-1348 247.0100
RFQ
ECAD 24 0.00000000 Bel Power Solutions MFLS250 (250W) Box Active -40°C ~ 70°C (With Derating) Medical 4.50" L x 2.50" W x 1.58" H (114.3mm x 63.5mm x 40.1mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-MFLS250-1348 EAR99 8504.40.9530 24 250W (346W Forced Air) 1 94% 48V - - - - - - 4.38 kV 60601-1 7.2 A
MFLS400-1358-SF Bel Power Solutions MFLS400-1358-SF 302.1821
RFQ
ECAD 8667 0.00000000 Bel Power Solutions MFLS400 (400W) Box Active -40°C ~ 70°C (With Derating) Medical 5.31" L x 4.29" W x 1.97" H (135.0mm x 109.0mm x 50.0mm) Chassis Mount Enclosed Adjustable Output, PFC, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC download ROHS3 Compliant Not Applicable REACH Unaffected 179-MFLS400-1358-SF EAR99 8504.40.9530 24 400W 1 90% 58V - - - - - - 4.38 kV 60601-1 6.9 A
FLS400-1358-SF Bel Power Solutions FLS400-1358-SF 269.2763
RFQ
ECAD 1635 0.00000000 Bel Power Solutions FLS400 (400W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 5.31" L x 4.29" W x 1.97" H (135.0mm x 109.0mm x 50.0mm) Chassis Mount Enclosed Adjustable Output, PFC, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC download ROHS3 Compliant Not Applicable REACH Unaffected 179-FLS400-1358-SF EAR99 8504.40.9530 24 400W 1 90% 58V - - - - - - 4 kV 62368-1 6.9 A
MFLS250-2312 Bel Power Solutions MFLS250-2312 260.2700
RFQ
ECAD 24 0.00000000 Bel Power Solutions MFLS250 (250W) Box Active -40°C ~ 70°C (With Derating) Medical 4.50" L x 2.50" W x 1.58" H (114.3mm x 63.5mm x 40.1mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Remote On/Off, Standby Output, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-MFLS250-2312 EAR99 8504.40.9530 24 199W (216W Forced Air) 1 94% 12V - - - - - - 4.38 kV 60601-1 18 A
MFLS250-2012 Bel Power Solutions MFLS250-2012 260.2700
RFQ
ECAD 24 0.00000000 Bel Power Solutions MFLS250 (250W) Box Active -40°C ~ 70°C (With Derating) Medical 4.50" L x 2.50" W x 1.58" H (114.3mm x 63.5mm x 40.1mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Remote On/Off, Standby Output, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-MFLS250-2012 EAR99 8504.40.9530 24 199W (300W Forced Air) 1 94% 12V - - - - - - 4.38 kV 60601-1 25 A
FLS400-1315-SF Bel Power Solutions FLS400-1315-SF 269.2763
RFQ
ECAD 6609 0.00000000 Bel Power Solutions FLS400 (400W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 5.31" L x 4.29" W x 1.97" H (135.0mm x 109.0mm x 50.0mm) Chassis Mount Enclosed Adjustable Output, PFC, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC download ROHS3 Compliant Not Applicable REACH Unaffected 179-FLS400-1315-SF EAR99 8504.40.9530 24 300W 1 90% 15V - - - - - - 4 kV 62368-1 20 A
MFLS250-2058 Bel Power Solutions MFLS250-2058 244.0058
RFQ
ECAD 4837 0.00000000 Bel Power Solutions FLS250 (250W) Box Active -40°C ~ 70°C (With Derating) Medical 4.50" L x 2.50" W x 1.57" H (114.3mm x 63.5mm x 39.9mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Remote On/Off, Standby Output, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-MFLS250-2058 EAR99 8504.40.9530 24 249W (348W Forced Air) 1 94% 58V - - - - - - 4.38 kV 60601-1 6 A
FLS400-1330-TF Bel Power Solutions FLS400-1330-TF 269.2763
RFQ
ECAD 8285 0.00000000 Bel Power Solutions FLS400 (400W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 5.31" L x 4.29" W x 1.97" H (135.0mm x 109.0mm x 50.0mm) Chassis Mount Enclosed Adjustable Output, PFC, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC download ROHS3 Compliant Not Applicable REACH Unaffected 179-FLS400-1330-TF EAR99 8504.40.9530 24 399W 1 90% 30V - - - - - - 4 kV 62368-1 13.3 A
FLS400-1348-SF Bel Power Solutions FLS400-1348-SF 287.2300
RFQ
ECAD 23 0.00000000 Bel Power Solutions FLS400 (400W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 5.31" L x 4.29" W x 1.97" H (135.0mm x 109.0mm x 50.0mm) Chassis Mount Enclosed Adjustable Output, PFC, Remote Sense, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC download ROHS3 Compliant Not Applicable REACH Unaffected 179-FLS400-1348-SF EAR99 8504.40.9530 24 398W 1 90% 48V - - - - - - 4 kV 62368-1 8.3 A
MFLS250-1030 Bel Power Solutions MFLS250-1030 231.5679
RFQ
ECAD 4479 0.00000000 Bel Power Solutions FLS250 (250W) Box Active -40°C ~ 70°C (With Derating) Medical 4.50" L x 2.50" W x 1.57" H (114.3mm x 63.5mm x 39.9mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-MFLS250-1030 EAR99 8504.40.9530 24 249W (348W Forced Air) 1 94% 30V - - - - - - 4.38 kV 60601-1 11.6 A
FLS250-2015 Bel Power Solutions FLS250-2015 220.3567
RFQ
ECAD 9810 0.00000000 Bel Power Solutions FLS250 (250W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 4.50" L x 2.50" W x 1.57" H (114.3mm x 63.5mm x 39.9mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Remote On/Off, Standby Output, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-FLS250-2015 EAR99 8504.40.9530 24 200W (300W Forced Air) 1 94% 15V - - - - - - 4 kV 62368-1 20 A
MFLS250-1012 Bel Power Solutions MFLS250-1012 247.0100
RFQ
ECAD 24 0.00000000 Bel Power Solutions MFLS250 (250W) Box Active -40°C ~ 70°C (With Derating) Medical 4.50" L x 2.50" W x 1.58" H (114.3mm x 63.5mm x 40.1mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-MFLS250-1012 EAR99 8504.40.9530 24 199W (300W Forced Air) 1 94% 12V - - - - - - 4.38 kV 60601-1 25 A
MFLS250-2024 Bel Power Solutions MFLS250-2024 260.2700
RFQ
ECAD 24 0.00000000 Bel Power Solutions MFLS250 (250W) Box Active -40°C ~ 70°C (With Derating) Medical 4.50" L x 2.50" W x 1.58" H (114.3mm x 63.5mm x 40.1mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Remote On/Off, Standby Output, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-MFLS250-2024 EAR99 8504.40.9530 24 250W (348W Forced Air) 1 94% 24V - - - - - - 4.38 kV 60601-1 14.5 A
MFLS250-1315 Bel Power Solutions MFLS250-1315 231.5679
RFQ
ECAD 8925 0.00000000 Bel Power Solutions FLS250 (250W) Box Active -40°C ~ 70°C (With Derating) Medical 4.50" L x 2.50" W x 1.57" H (114.3mm x 63.5mm x 39.9mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-MFLS250-1315 EAR99 8504.40.9530 24 200W (270W Forced Air) 1 94% 15V - - - - - - 4.38 kV 60601-1 18 A
FLS250-1312 Bel Power Solutions FLS250-1312 222.5200
RFQ
ECAD 24 0.00000000 Bel Power Solutions FLS250 (250W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 4.50" L x 2.50" W x 1.58" H (114.3mm x 63.5mm x 40.1mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-FLS250-1312 EAR99 8504.40.9530 24 199W (300W Forced Air) 1 94% 12V - - - - - - 4 kV 62368-1 25 A
FLS400-1324-TF Bel Power Solutions FLS400-1324-TF 287.2300
RFQ
ECAD 23 0.00000000 Bel Power Solutions FLS400 (400W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 4.87" L x 3.04" W x 3.24" H (123.7mm x 77.2mm x 82.3mm) Chassis Mount Enclosed Adjustable Output, PFC, Remote Sense, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC download ROHS3 Compliant Not Applicable REACH Unaffected 179-FLS400-1324-TF EAR99 8504.40.9530 24 401W 1 90% 24V - - - - - - 4 kV 62368-1 16.7 A
FLS250-1324 Bel Power Solutions FLS250-1324 222.5200
RFQ
ECAD 24 0.00000000 Bel Power Solutions FLS250 (250W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 4.50" L x 2.50" W x 1.58" H (114.3mm x 63.5mm x 40.1mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-FLS250-1324 EAR99 8504.40.9530 24 250W (348W Forced Air) 1 94% 24V - - - - - - 4 kV 62368-1 14.5 A
FLS250-2324 Bel Power Solutions FLS250-2324 220.3567
RFQ
ECAD 8679 0.00000000 Bel Power Solutions FLS250 (250W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 4.50" L x 2.50" W x 1.57" H (114.3mm x 63.5mm x 39.9mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Remote On/Off, Standby Output, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-FLS250-2324 EAR99 8504.40.9530 24 250W (348W Forced Air) 1 94% 24V - - - - - - 4 kV 62368-1 14.5 A
FLS250-1315 Bel Power Solutions FLS250-1315 208.6154
RFQ
ECAD 5887 0.00000000 Bel Power Solutions FLS250 (250W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 4.50" L x 2.50" W x 1.57" H (114.3mm x 63.5mm x 39.9mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-FLS250-1315 EAR99 8504.40.9530 24 200W (270W Forced Air) 1 94% 15V - - - - - - 4 kV 62368-1 18 A
350DNC40-12-CG Bel Power Solutions 350DNC40-12-CG 5.0000
RFQ
ECAD 5 0.00000000 Bel Power Solutions DNC (3300W) Box Active -40°C ~ 45°C ITE (Commercial) 13.78" L x 13.44" W x 7.36" H (350.0mm x 341.5mm x 187.0mm) Chassis Mount Enclosed - 430VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-350DNC40-12-CG EAR99 8504.40.9580 1 3300W 1 229A 240VDC 92% 14.4V - - - 3 kV -
LWR1606-6C1G Bel Power Solutions LWR1606-6C1G -
RFQ
ECAD 1161 0.00000000 Bel Power Solutions W (125W) Bulk Active -40°C ~ 60°C Industrial, ITE (Commercial) 4.47" L x 4.05" W x 5.43" H (113.5mm x 102.9mm x 137.9mm) Adjustable Output, PFC, Universal Input AC or DC cCSAus, CE, cULus, NEMKO - ROHS3 Compliant Not Applicable REACH Unaffected 179-LWR1606-6C1G EAR99 8504.40.9520 1 - 1 - - 85 ~ 264 VAC - - - - - - - 90V 350V 4.2 kV 60950-1; 62368-1; UL 508
LXR1801-6G Bel Power Solutions LXR1801-6G -
RFQ
ECAD 7572 0.00000000 Bel Power Solutions X (375W) Bulk Active -40°C ~ 60°C ITE (Commercial), Laboratory 4.47" L x 7.64" W x 5.43" H (113.5mm x 194.1mm x 137.9mm) Adjustable Output, PFC, Universal Input AC or DC cCSAus, CE download ROHS3 Compliant Not Applicable REACH Unaffected 179-LXR1801-6G EAR99 8504.40.9530 1 371W 1 7.5A 88% 85 ~ 264 VAC 49.4V - - - - - - 90V 350V 4.2 kV 60950-1; 61010-1
LWN1701-6EM1G Bel Power Solutions LWN1701-6EM1G -
RFQ
ECAD 3226 0.00000000 Bel Power Solutions W (250W) Bulk Active -40°C ~ 60°C Industrial, ITE (Commercial) 4.47" L x 4.05" W x 5.43" H (113.5mm x 102.9mm x 137.9mm) Adjustable Output, PFC, Universal Input AC or DC cCSAus, CE, cULus, NEMKO download ROHS3 Compliant Not Applicable REACH Unaffected 179-LWN1701-6EM1G EAR99 8504.40.9530 1 245W 1 6.6A 88% 85 ~ 264 VAC 37.05V - - - - - - 90V 350V 4.2 kV 60950-1; 62368-1; UL 508
MEPG500-1230 Bel Power Solutions MEPG500-1230 330.8760
RFQ
ECAD 1216 0.00000000 Bel Power Solutions MEPG500 (500W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 5.00" L x 3.00" W x 1.58" H (127.0mm x 76.2mm x 40.0mm) Chassis Mount Open Frame Adjustable Output, I²C Interface, PFC, Remote On/Off, Remote Sense, Universal Input CE 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) 179-MEPG500-1230 EAR99 8504.40.9530 42 300W (500W Forced Air) 1 94% 30V - - - - - - 4 kV 62368-1 16.67 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse