Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Ratings | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Termination Style | Weight | Voltage - Input (Max) | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Topology | Dimming | Voltage - Output | Current - Output (Max) | Voltage - Input (Min) | Efficiency | SIC Programmable |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
LED12W-36-C0250-D | 28.8917 | ![]() |
5144 | 0.00000000 | Thomas Research Products | LED-12W | Box | Active | - | IP66 | 4.04" L x 1.48" W x 0.95" H (102.6mm x 37.6mm x 24.1mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | LED12W | CE, cURus | Wire Leads | 0.363 lb (164.65 g) | 305VAC | download | RoHS Compliant | 1 (Unlimited) | EAR99 | 8504.40.9510 | 1 | 9 W | 1 | AC DC Converter | Analog | 18 ~ 36V | 250mA | 108VAC | 77% | Not Verified | |||
![]() |
BLED12W-024-C0500 | - | ![]() |
6832 | 0.00000000 | Thomas Research Products | BLED-12W | Box | Obsolete | - | IP64 | 3.00" L x 1.23" W x 0.98" H (76.2mm x 31.2mm x 24.9mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | Wire Leads | 0.243 lbs (110.0 g) | 305VAC | download | RoHS Compliant | 1 (Unlimited) | 93056272 | OBSOLETE | 0000.00.0000 | 1 | 12 W | 1 | AC DC Converter | - | 15 ~ 24V | 500mA | 90VAC | 85% | Not Verified | |||
![]() |
BLED25W-012-C2100 | - | ![]() |
5274 | 0.00000000 | Thomas Research Products | BLED-25W | Box | Obsolete | - | IP64 | 3.44" L x 1.44" W x 0.94" H (87.4mm x 36.6mm x 23.9mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | Wire Leads | 0.282 lbs (128.0 g) | 305VAC | download | RoHS Compliant | 1 (Unlimited) | 93056280 | OBSOLETE | 0000.00.0000 | 1 | 25 W | 1 | AC DC Converter | - | 7 ~ 12V | 2.1A | 90VAC | 83% | Not Verified | |||
![]() |
BLED25W-048-C0520 | - | ![]() |
6119 | 0.00000000 | Thomas Research Products | BLED-25W | Box | Obsolete | - | IP64 | 3.44" L x 1.44" W x 0.94" H (87.4mm x 36.6mm x 23.9mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | Wire Leads | 0.282 lbs (128.0 g) | 305VAC | download | RoHS Compliant | 1 (Unlimited) | 93056282 | OBSOLETE | 0000.00.0000 | 1 | 25 W | 1 | AC DC Converter | - | 29 ~ 48V | 520mA | 90VAC | 87% | Not Verified | |||
![]() |
BLED40W-114-C0350 | - | ![]() |
5798 | 0.00000000 | Thomas Research Products | BLED-40W | Box | Obsolete | - | IP64 | 3.15" L x 2.44" W x 0.99" H (80.0mm x 62.0mm x 25.1mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | Wire Leads | 0.437 lbs (198.0 g) | 305VAC | download | RoHS Compliant | 1 (Unlimited) | 93057259 | OBSOLETE | 0000.00.0000 | 1 | 40 W | 1 | AC DC Converter | - | 68 ~ 114V | 350mA | 90VAC | 90% | Not Verified | |||
![]() |
LED100W-041-C2000-D-SP06 | - | ![]() |
1480 | 0.00000000 | Thomas Research Products | - | Box | Obsolete | download | RoHS Compliant | 1 (Unlimited) | 93056313 | OBSOLETE | 0000.00.0000 | 1 | Not Verified | ||||||||||||||||||||
![]() |
LED40W-024-C1400-AU | - | ![]() |
8656 | 0.00000000 | Thomas Research Products | LED-40W | Box | Obsolete | - | IP66, NEMA 4 | 3.74" L x 2.76" W x 1.26" H (95.0mm x 70.1mm x 32.0mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | Wire Leads | - | 305VAC | - | RoHS Compliant | 1 (Unlimited) | 93056473 | OBSOLETE | 0000.00.0000 | 1 | 33.6 W | 1 | AC DC Converter | - | 8 ~ 24V | 1.4A | 90VAC | 85% | Not Verified | |||
![]() |
LED60W-043-C1400-PD | - | ![]() |
2889 | 0.00000000 | Thomas Research Products | LED-60W | Box | Obsolete | - | IP66 | 6.42" L x 2.81" W x 1.83" H (163.1mm x 71.4mm x 46.5mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | Wire Leads | - | 305VAC | - | RoHS Compliant | 1 (Unlimited) | 93056565 | OBSOLETE | 0000.00.0000 | 1 | 60 W | 1 | AC DC Converter | Analog | 14 ~ 43V | 1.4A | 90VAC | 91% | Not Verified | |||
![]() |
LED60W-170-C0350-PD | - | ![]() |
2189 | 0.00000000 | Thomas Research Products | LED-60W | Box | Obsolete | - | IP66 | 6.42" L x 2.81" W x 1.83" H (163.1mm x 71.4mm x 46.5mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | Wire Leads | - | 305VAC | - | RoHS Compliant | 1 (Unlimited) | 93056583 | OBSOLETE | 0000.00.0000 | 1 | 59.5 W | 1 | AC DC Converter | Analog | 56 ~ 170V | 350mA | 90VAC | 92% | Not Verified | |||
![]() |
LED90W-022-C4090-D | - | ![]() |
9634 | 0.00000000 | Thomas Research Products | LED-90W | Box | Obsolete | - | IP66 | 6.42" L x 2.81" W x 1.83" H (163.1mm x 71.4mm x 46.5mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | Wire Leads | - | 305VAC | download | RoHS Compliant | 1 (Unlimited) | 93056622 | OBSOLETE | 0000.00.0000 | 1 | 90 W | 1 | AC DC Converter | Analog | 7 ~ 22V | 4.09A | 90VAC | 89% | Not Verified | |||
![]() |
LED90W-025 | - | ![]() |
9027 | 0.00000000 | Thomas Research Products | LED-90W | Box | Obsolete | - | IP66 | 6.42" L x 2.81" W x 1.83" H (163.1mm x 71.4mm x 46.5mm) | Chassis Mount | Constant Voltage | OCP, OVP, SCP | Wire Leads | - | 305VAC | download | RoHS Compliant | 1 (Unlimited) | 93056623 | OBSOLETE | 0000.00.0000 | 1 | 90 W | 1 | AC DC Converter | - | 25V | 3.5A | 90VAC | 89% | Not Verified | |||
![]() |
LED90W-027-C3330-D | - | ![]() |
3328 | 0.00000000 | Thomas Research Products | LED-90W | Box | Obsolete | - | IP66 | 6.42" L x 2.81" W x 1.83" H (163.1mm x 71.4mm x 46.5mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | Wire Leads | - | 305VAC | download | RoHS Compliant | 1 (Unlimited) | 93056625 | OBSOLETE | 0000.00.0000 | 1 | 90 W | 1 | AC DC Converter | Analog | 9 ~ 27V | 3.33A | 90VAC | 89% | Not Verified | |||
![]() |
LED90W-056-C1600 | - | ![]() |
7304 | 0.00000000 | Thomas Research Products | LED-90W | Box | Obsolete | - | IP66 | 6.42" L x 2.81" W x 1.83" H (163.1mm x 71.4mm x 46.5mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | Wire Leads | - | 305VAC | download | RoHS Compliant | 1 (Unlimited) | 93056628 | OBSOLETE | 0000.00.0000 | 1 | 90 W | 1 | AC DC Converter | - | 18 ~ 56V | 1.6A | 90VAC | 91% | Not Verified | |||
![]() |
LEG100W-143-C0700-D | - | ![]() |
6437 | 0.00000000 | Thomas Research Products | LEG-100W | Box | Obsolete | - | IP66 | 8.30" L x 1.80" W x 1.32" H (210.8mm x 45.7mm x 33.5mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | Wire Leads | 1.627 lbs (738.0 g) | 305VAC | download | RoHS Compliant | 1 (Unlimited) | 93056646 | OBSOLETE | 0000.00.0000 | 1 | 100 W | 1 | AC DC Converter | Analog | 48 ~ 143V | 700mA | 108VAC | 90% | Not Verified | |||
![]() |
LEG100W-286-C0350 | - | ![]() |
1507 | 0.00000000 | Thomas Research Products | LEG-100W | Box | Obsolete | - | IP66 | 8.30" L x 1.80" W x 1.32" H (210.8mm x 45.7mm x 33.5mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | Wire Leads | 1.627 lbs (738.0 g) | 305VAC | download | RoHS Compliant | 1 (Unlimited) | 93056649 | OBSOLETE | 0000.00.0000 | 1 | 100 W | 1 | AC DC Converter | - | 95 ~ 286V | 286mA | 108VAC | 92% | Not Verified | |||
![]() |
LEG100W-286-C0350-D | - | ![]() |
3813 | 0.00000000 | Thomas Research Products | LEG-100W | Box | Obsolete | - | IP66 | 8.30" L x 1.80" W x 1.32" H (210.8mm x 45.7mm x 33.5mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | Wire Leads | 1.627 lbs (738.0 g) | 305VAC | download | RoHS Compliant | 1 (Unlimited) | 93056650 | OBSOLETE | 0000.00.0000 | 1 | 100 W | 1 | AC DC Converter | Analog | 95 ~ 286V | 286mA | 108VAC | 92% | Not Verified | |||
![]() |
LEG120W-114-C1050-D | - | ![]() |
9992 | 0.00000000 | Thomas Research Products | LEG-120W | Box | Obsolete | - | IP66 | 8.30" L x 1.80" W x 1.32" H (210.8mm x 45.7mm x 33.5mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | Wire Leads | 1.627 lbs (738.0 g) | 305VAC | download | RoHS Compliant | 1 (Unlimited) | 93056654 | OBSOLETE | 0000.00.0000 | 1 | 120 W | 1 | AC DC Converter | Analog | 38 ~ 114V | 1.05A | 108VAC | 88% | Not Verified | |||
![]() |
LEG120W-343-C0350 | - | ![]() |
6787 | 0.00000000 | Thomas Research Products | LEG-120W | Box | Obsolete | - | IP66 | 8.30" L x 1.80" W x 1.32" H (210.8mm x 45.7mm x 33.5mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | Wire Leads | 1.627 lbs (738.0 g) | 305VAC | download | RoHS Compliant | 1 (Unlimited) | 93056659 | OBSOLETE | 0000.00.0000 | 1 | 120 W | 1 | AC DC Converter | - | 114 ~ 343V | 350mA | 108VAC | 91% | Not Verified | |||
![]() |
LEG75W-108-C0700 | - | ![]() |
4800 | 0.00000000 | Thomas Research Products | LEG-75W | Box | Obsolete | - | IP66 | 8.30" L x 1.80" W x 1.32" H (210.8mm x 45.7mm x 33.5mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | Wire Leads | 1.627 lbs (738.0 g) | 305VAC | download | RoHS Compliant | 1 (Unlimited) | 93056670 | OBSOLETE | 0000.00.0000 | 1 | 75 W | 1 | AC DC Converter | - | 36 ~ 108V | 700mA | 108VAC | 90% | Not Verified | |||
![]() |
TSC-150S350DT | - | ![]() |
4929 | 0.00000000 | Thomas Research Products | TSC-150W | Box | Obsolete | -35°C ~ 65°C | IP67 | 7.40" L x 3.46" W x 1.50" H (188.0mm x 88.0mm x 38.0mm) | Chassis Mount | Constant Current | OTP, OVP, SCP | Wire Leads | 528VAC | download | RoHS Compliant | 1 (Unlimited) | 93056995 | OBSOLETE | 0000.00.0000 | 1 | 150 W | 1 | AC DC Converter | Analog | 21 ~ 43V | 3.5A | 249VAC | 89% | Not Verified | ||||
![]() |
TRV-200S048ST | - | ![]() |
8830 | 0.00000000 | Thomas Research Products | TRV-200 (200W) | Bulk | Obsolete | - | IP67 | 8.90" L x 2.66" W x 1.57" H (226.0mm x 67.5mm x 40.0mm) | Chassis Mount | Constant Voltage | OCP, OTP, OVP, SCP | CE, cURus | Wire Leads | 305VAC | download | RoHS Compliant | 1 (Unlimited) | EAR99 | 8504.40.9530 | 1 | 200 W | 1 | AC DC Converter | - | 48V | 4.17A | 90VAC | 92.5% | Not Verified | ||||
BLED12W-016-C0800 | - | ![]() |
6766 | 0.00000000 | Thomas Research Products | BLED-12W | Box | Obsolete | - | IP64 | 3.00" L x 1.23" W x 0.98" H (75.9mm x 31.2mm x 25.0mm) | Chassis Mount | Constant Current | - | cURus | Wire Leads | 305VAC | download | RoHS Compliant | 1 (Unlimited) | EAR99 | 8504.40.9510 | 50 | 12 W | 1 | AC DC Converter | - | 10 ~ 16V | 800mA | 90VAC | 83% | Not Verified | |||||
BLED20W-022-C0900 | 10.3300 | ![]() |
403 | 0.00000000 | Thomas Research Products | BLED-20W | Box | Obsolete | - | IP64 | 2.72" L x 2.04" W x 1.03" H (69.0mm x 51.8mm x 26.0mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | cURus | Wire Leads | 0.243 lb (110.22 g) | 305VAC | download | RoHS Compliant | 1 (Unlimited) | EAR99 | 8504.40.9510 | 50 | 20 W | 1 | AC DC Converter | - | 13 ~ 22V | 900mA | 90VAC | 83% | Not Verified | ||||
BLED20W-028-C0700 | - | ![]() |
7037 | 0.00000000 | Thomas Research Products | BLED-20W | Box | Obsolete | - | IP64 | 2.72" L x 2.04" W x 1.03" H (69.0mm x 51.8mm x 26.0mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | cURus | Wire Leads | 0.243 lb (110.22 g) | 305VAC | download | RoHS Compliant | 1 (Unlimited) | EAR99 | 8504.40.9510 | 50 | 20 W | 1 | AC DC Converter | - | 17 ~ 28V | 700mA | 90VAC | 84% | Not Verified | ||||
BLED20W-036-C0550 | 14.9200 | ![]() |
33 | 0.00000000 | Thomas Research Products | BLED-20W | Box | Obsolete | - | IP64 | 2.72" L x 2.04" W x 1.03" H (69.0mm x 51.8mm x 26.0mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | cURus | Wire Leads | 0.243 lb (110.22 g) | 305VAC | download | RoHS Compliant | 1 (Unlimited) | EAR99 | 8504.40.9510 | 50 | 20 W | 1 | AC DC Converter | - | 21 ~ 36V | 550mA | 90VAC | 85% | Not Verified | ||||
LED12W-48-C0250-D | 34.8500 | ![]() |
53 | 0.00000000 | Thomas Research Products | LED-12W | Box | Active | - | IP66 | - | Chassis Mount | Constant Current | OCP, OVP, SCP | LED12W | CE, cURus | Wire Leads | 0.282 lb (127.91 g) | 305VAC | download | RoHS Compliant | 1 (Unlimited) | EAR99 | 8504.40.9510 | 1 | 12 W | 1 | AC DC Converter | Analog | 24 ~ 48V | 250mA | 90VAC | 80% | Not Verified | |||
LED25W-12-C2080 | 11.9600 | ![]() |
124 | 0.00000000 | Thomas Research Products | LED-25W | Box | Active | - | IP66 | 3.15" L x 2.44" W x 0.99" H (80.0mm x 62.0mm x 25.2mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | LED25W | CE, cURus | Wire Leads | 0.437 lb (198.00 g) | 305VAC | download | RoHS Compliant | 1 (Unlimited) | EAR99 | 8504.40.9510 | 500 | 25 W | 1 | AC DC Converter | - | 4 ~ 12V | 2.08A | 90VAC | 81% | Not Verified | |||
LED40W230-036-C1100-LT | 51.6902 | ![]() |
8027 | 0.00000000 | Thomas Research Products | LED-40W-LT | Box | Active | - | IP66, NEMA 4 | 3.78" L x 2.80" W x 1.26" H (96.0mm x 71.0mm x 32.0mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | LED40W | CE, cURus | Wire Leads | 277VAC | download | RoHS Compliant | 1 (Unlimited) | EAR99 | 8504.40.9510 | 500 | 40 W | 1 | AC DC Converter | - | 22 ~ 36V | 1.1A | 220VAC | 85% | Not Verified | ||||
![]() |
LED40W230-054-C0700-LT | 51.6902 | ![]() |
9819 | 0.00000000 | Thomas Research Products | LED-40W-LT | Box | Active | - | IP66, NEMA 4 | 3.78" L x 2.80" W x 1.26" H (96.0mm x 71.0mm x 32.0mm) | Chassis Mount | Constant Current | OCP, OVP, SCP | LED40W | CE, cURus | Wire Leads | 277VAC | download | RoHS Compliant | 1 (Unlimited) | EAR99 | 8504.40.9510 | 500 | 40 W | 1 | AC DC Converter | - | 34 ~ 54V | 700mA | 220VAC | 86% | Not Verified | |||
![]() |
LED60W-024 | 40.6700 | ![]() |
187 | 0.00000000 | Thomas Research Products | LED-60W | Box | Obsolete | - | IP66 | 6.81" L x 2.81" W x 1.83" H (173.0mm x 71.3mm x 46.5mm) | Chassis Mount | Constant Voltage | OCP, OVP, SCP | CE, cURus | Wire Leads | 305VAC | download | RoHS Compliant | 1 (Unlimited) | EAR99 | 8504.40.9520 | 25 | 60 W | 1 | AC DC Converter | - | 24V | 2.5A | 90VAC | 90% | Not Verified |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse