Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Features | Base Product Number | Input Type | Approval Agency | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Current - Output (Max) | Efficiency | AC Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | DC Voltage - Input (Min) | DC Voltage - Input (Max) | Voltage - Isolation | Standard Number |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
TBLC 50-112 | 80.0700 | ![]() |
10 | 0.00000000 | Traco Power | TBLC (50W) | Box | Active | -25°C ~ 70°C (With Derating) | Household Appliances, Industrial, ITE (Commercial) | 2.15" L x 2.13" W x 3.52" H (54.6mm x 54.1mm x 89.4mm) | Adjustable Output, IP20, Universal Input | TBLC 50 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 48W | 1 | 4A | 88% | 85 ~ 264 VAC | 12V | - | - | - | - | - | - | 3 kV | |||||
![]() |
TIS 150-124 SIG | - | ![]() |
4242 | 0.00000000 | Traco Power | TIS (150W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 6.18" L x 2.23" W x 4.51" H (157.0mm x 56.6mm x 114.6mm) | Adjustable Output, IP20, Remote On/Off | AC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 2 | 144W | 1 | 6A | 85% | 93 ~ 132 VAC, 187 ~ 264 VAC | 24V | - | - | - | - | - | - | |||||||
![]() |
TIS 300-148 SIG | - | ![]() |
8828 | 0.00000000 | Traco Power | TIS (300W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 8.15" L x 3.27" W x 4.51" H (207.0mm x 83.1mm x 114.6mm) | Adjustable Output, IP20, Remote On/Off | AC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9530 | 2 | 288W | 1 | 6A | 85% | 93 ~ 132 VAC, 187 ~ 264 VAC | 48V | - | - | - | - | - | - | |||||||
![]() |
TIS 500-124-230 | - | ![]() |
3419 | 0.00000000 | Traco Power | TIS (500W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 8.66" L x 3.27" W x 5.12" H (220.0mm x 83.1mm x 130.0mm) | Adjustable Output, IP20 | AC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9530 | 2 | 480W | 1 | 20A | 90% | 187 ~ 264 VAC | 24V | - | - | - | - | - | - | |||||||
![]() |
TIS 50-124 | - | ![]() |
9968 | 0.00000000 | Traco Power | TIS (50W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 2.95" L x 2.23" W x 3.94" H (74.9mm x 56.6mm x 100.1mm) | Adjustable Output, IP20 | AC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 2 | 48W | 1 | 2A | 85% | 93 ~ 264 VAC | 24V | - | - | - | - | - | - | |||||||
![]() |
TIS 600-124 | - | ![]() |
1320 | 0.00000000 | Traco Power | TIS (600W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 9.57" L x 3.25" W x 6.98" H (243.1mm x 82.6mm x 177.3mm) | Adjustable Output, IP20 | AC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 2 | 576W | 1 | 24A | 90% | 93 ~ 132 VAC, 187 ~ 264 VAC | 24V | - | - | - | - | - | - | |||||||
![]() |
TIS 600-124 RED | - | ![]() |
7190 | 0.00000000 | Traco Power | TIS (600W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 9.57" L x 3.25" W x 6.98" H (243.1mm x 82.6mm x 177.3mm) | Adjustable Output, IP20, Load Sharing | AC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 2 | 576W | 1 | 24A | 90% | 93 ~ 132 VAC, 187 ~ 264 VAC | 24V | - | - | - | - | - | - | |||||||
![]() |
TIS 75-148 | - | ![]() |
8630 | 0.00000000 | Traco Power | TIS (75W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 3.54" L x 2.23" W x 4.51" H (89.9mm x 56.6mm x 114.6mm) | Adjustable Output, IP20 | AC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 2 | 72W | 1 | 1.5A | 85% | 93 ~ 132 VAC, 187 ~ 264 VAC | 48V | - | - | - | - | - | - | |||||||
![]() |
TPC 055-112 | 86.7000 | ![]() |
10 | 0.00000000 | Traco Power | TPC (55W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.80" L x 1.77" W x 3.54" H (96.5mm x 45.0mm x 89.9mm) | Adjustable Output, IP20, Universal Input | TPC 055 | AC or DC | CB, CE, cCSAus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 42W | 1 | 3.5A | 87% | 85 ~ 264 VAC | 12V | - | - | - | - | - | - | 90V | 375V | ||||
![]() |
TSP 090-124N | 158.5900 | ![]() |
10 | 0.00000000 | Traco Power | TSP (90-96W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 4.33" L x 1.38" W x 4.33" H (110.0mm x 35.1mm x 110.0mm) | Adjustable Output, IP20, Remote On/Off, Universal Input | TSP 090 | AC | CB, CE, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 10 | 90W | 1 | 3.75A | 87% | 85 ~ 264 VAC | 24V | - | - | - | - | - | - | ||||||
![]() |
TSP240-124-3PAC500 | - | ![]() |
2613 | 0.00000000 | Traco Power | TSP-3P (240W) | Box | Obsolete | -25°C ~ 60°C | Hazardous Locations, Industrial, ITE (Commercial) | 4.33" L x 2.13" W x 4.33" H (110.0mm x 54.1mm x 110.0mm) | IP20 | AC | CB, CE, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9530 | 10 | 240W | 1 | 10A | 92% | 400 ~ 550 VAC (3 Phase) | 24V | - | - | - | - | - | - | |||||||
![]() |
TSPC 050-112 | 92.4800 | ![]() |
1806 | 0.00000000 | Traco Power | TSPC (50W) | Box | Active | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 3.56" L x 1.45" W x 4.33" H (90.4mm x 36.8mm x 110.0mm) | Adjustable Output, IP20, Universal Input | TSPC 050 | AC | CB, CE | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 48W | 1 | 4A | 93% | 85 ~ 264 VAC | 12V | - | - | - | - | - | - | ||||||
![]() |
PS-S1005 | - | ![]() |
9992 | 0.00000000 | Altech Corporation | PS-S10 (10W) | Bulk | Obsolete | -20°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.94" L x 0.89" W x 3.54" H (100.0mm x 22.5mm x 90.0mm) | Adjustable Output, Universal Input | AC or DC | CE, cULus | - | ROHS3 Compliant | 1 (Unlimited) | EAR99 | 8504.40.9510 | 1 | 10W | 1 | 2A | 77% | 85 ~ 264 VAC | 5V | - | - | - | - | - | No | 120V | 370V | 3 kV | 508; 60950-1 | ||||
![]() |
PS-S4012 | - | ![]() |
2769 | 0.00000000 | Altech Corporation | PS-S40 (40W) | Bulk | Obsolete | -20°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.94" L x 1.57" W x 3.54" H (100.0mm x 40.0mm x 90.0mm) | Adjustable Output, Universal Input | AC or DC | CE, cULus | - | ROHS3 Compliant | 1 (Unlimited) | EAR99 | 8504.40.9510 | 1 | 40W | 1 | 3.33A | 86% | 85 ~ 264 VAC | 12V | - | - | - | - | - | No | 120V | 370V | 3 kV | 508; 60950-1 | ||||
![]() |
IS.AC24VDC5ADIN | 111.6200 | ![]() |
1 | 0.00000000 | Industrial Shields | - | Box | Active | - | ITE (Commercial) | - | Universal Input | IS.AC24 | AC | - | - | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 2198-IS.AC24VDC5ADIN | EAR99 | 8504.40.9520 | 1 | 120W | 1 | 5A | - | 90 ~ 264 VAC | 24V | - | - | - | - | - | - | |||||
![]() |
DSR240PS24 | 124.0000 | ![]() |
16 | 0.00000000 | XP Power | DSR240 (240W) | Box | Active | -25°C ~ 70°C | ITE (Commercial) | 4.88" L x 1.77" W x 4.69" H (124.0mm x 45.0mm x 119.1mm) | Universal Input | DSR240 | AC | - | download | ROHS3 Compliant | Not Applicable | EAR99 | 8504.40.9530 | 1 | 240W | 1 | 10A | 94% | 85 ~ 264 VAC | 24V | - | - | - | - | - | - | 62368-1 | ||||||
![]() |
DNR480PS24 | - | ![]() |
1889 | 0.00000000 | XP Power | DNR (480W) | Box | Active | -40°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 6.89" L x 4.57" W x 4.92" H (175.0mm x 116.0mm x 125.0mm) | Adjustable Output, Standby Output, Universal Input | DNR480 | AC or DC | CE | download | ROHS3 Compliant | Not Applicable | EAR99 | 8504.40.9530 | 1 | 480W | 1 | 20A | 89% | 90 ~ 264 VAC | 24V | - | - | - | - | - | No | 120V | 375V | 3 kV | ||||
![]() |
DRB240-24-1 | 109.2600 | ![]() |
1416 | 0.00000000 | TDK-Lambda Americas Inc | DRB (120-480W) | Bulk | Active | -20°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 4.92" L x 1.61" W x 4.88" H (125.0mm x 41.0mm x 124.0mm) | Adjustable Output, PFC, Universal Input | DRB240 | AC | CE, cULus, cURus, EAC | download | RoHS Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9530 | 1 | 240W | 1 | 10A | 93% | 85 ~ 265 VAC | 24V | - | - | - | - | - | - | 3 kV | |||||
![]() |
PDQE10-Q24-D5-DIN | 29.7700 | ![]() |
1 | 0.00000000 | CUI Inc. | PDQE10 (10W) | Tray | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial) | 2.99" L x 1.24" W x 0.87" H (76.0mm x 31.5mm x 22.2mm) | Remote On/Off | PDQE10 | DC | CB Scheme, IEC, UL | download | RoHS Compliant | Not Applicable | REACH Unaffected | 102-4826 | EAR99 | 8504.40.9580 | 24 | 10W | 2 | 1A, 1A | 83% | 5V | -5V | - | - | - | - | - | 9V | 36V | 1.5 kV | 60950-1 | ||
![]() |
PDQE10-Q24-S9-DIN | 28.8900 | ![]() |
18 | 0.00000000 | CUI Inc. | PDQE10 (10W) | Tray | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial) | 2.99" L x 1.24" W x 0.87" H (76.0mm x 31.5mm x 22.2mm) | Remote On/Off | PDQE10 | DC | EN | download | RoHS Compliant | Not Applicable | REACH Unaffected | 102-4833 | EAR99 | 8504.40.9580 | 24 | 10W | 1 | 1.111A | 86% | 9V | - | - | - | - | - | - | 9V | 36V | 1.5 kV | 55024; 55032 Class A | ||
![]() |
PDQE10-Q48-S5-DIN | 29.1600 | ![]() |
9252 | 0.00000000 | CUI Inc. | PDQE10 (10W) | Tray | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial) | 2.99" L x 1.24" W x 0.87" H (76.0mm x 31.5mm x 22.2mm) | Remote On/Off | PDQE10 | DC | EN | download | RoHS Compliant | Not Applicable | REACH Unaffected | 102-4851 | EAR99 | 8504.40.9580 | 24 | 10W | 1 | 2A | 83% | 5V | - | - | - | - | - | - | 18V | 75V | 1.5 kV | 55024; 55032 Class A | ||
![]() |
SPD121001 | 396.0000 | ![]() |
6 | 0.00000000 | Carlo Gavazzi Inc. | SPD (100W) | Box | Obsolete | -35°C ~ 71°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 4.49" L x 1.59" W x 3.54" H (114.0mm x 40.5mm x 90.0mm) | Adjustable Output, IP20, PFC, Universal Input | SPD12 | AC or DC | CE, cULus, TUV | download | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 1 | 101W | 1 | 8.4A | 84% | 90 ~ 264 VAC | 12V | - | - | - | - | - | No | 120V | 375V | 3 kV | ||||
![]() |
SPD121002 | 498.0000 | ![]() |
9 | 0.00000000 | Carlo Gavazzi Inc. | SPD (100W) | Box | Obsolete | -25°C ~ 71°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 4.49" L x 2.13" W x 3.54" H (114.0mm x 54.0mm x 90.0mm) | Adjustable Output, IP20, PFC | SPD12 | AC or DC | CE, cULus, TUV | download | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 1 | 101W | 1 | 8.4A | 86% | 340 ~ 575 VAC (2 Phase) | 12V | - | - | - | - | - | No | 480V | 820V | 3 kV | ||||
![]() |
TIB 080-148EX | 109.4100 | ![]() |
8887 | 0.00000000 | Traco Power | TIB 080EX (80W) | Box | Active | -40°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 3.71" L x 1.26" W x 4.50" H (94.2mm x 32.0mm x 114.2mm) | Adjustable Output, PFC, Universal Input | TIB 080 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-3306 | EAR99 | 8504.40.9520 | 10 | 82W | 1 | 1.7A | 90% | 85 ~ 264 VAC | 48V | - | - | - | - | - | - | 4.25 kV | ||||
![]() |
TIB 120-124EX | 128.8600 | ![]() |
5 | 0.00000000 | Traco Power | TIB 120EX (120W) | Box | Active | -40°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 4.50" L x 1.42" W x 4.89" H (114.2mm x 36.0mm x 124.2mm) | Adjustable Output, PFC, Universal Input | TIB 120 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 10 | 120W | 1 | 5A | 94% | 85 ~ 264 VAC | 24V | - | - | - | - | - | - | 4.25 kV | |||||
![]() |
TIB 240-148EX | 186.2600 | ![]() |
8724 | 0.00000000 | Traco Power | TIB 240EX (240W) | Box | Active | -40°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 4.50" L x 1.89" W x 4.89" H (114.2mm x 48.0mm x 124.2mm) | Adjustable Output, PFC, Universal Input | TIB 240 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-3311 | EAR99 | 8504.40.9530 | 10 | 240W | 1 | 5A | 95% | 85 ~ 264 VAC | 48V | - | - | - | - | - | - | 4.25 kV | ||||
![]() |
TIB 080-112 | 98.8000 | ![]() |
18 | 0.00000000 | Traco Power | TIB 080 (80W) | Box | Active | -40°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.71" L x 1.26" W x 4.50" H (94.2mm x 32.0mm x 114.2mm) | Adjustable Output, PFC, Universal Input | TIB 080 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-3314 | EAR99 | 8504.40.9520 | 10 | 80W | 1 | 6.7A | 88% | 85 ~ 264 VAC | 12V | - | - | - | - | - | - | 4.25 kV | ||||
![]() |
2904617 | 560.2800 | ![]() |
7489 | 0.00000000 | Phoenix Contact | Quint | Bulk | Active | -40°C ~ 75°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 4.80" L x 2.76" W x 5.12" H (122.0mm x 70.0mm x 130.0mm) | Adjustable Output, IP20 | AC or DC | cUL, cULus, EAC, UL, UR | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9530 | 1 | 480W | 1 | 20A | 94.2% | 100 ~ 240 VAC | 24V | - | - | - | - | - | - | 110V | 250V | 4 kV | |||||
![]() |
PSK-60-48-DIN | 25.6900 | ![]() |
6 | 0.00000000 | CUI Inc. | PSK-60 (60W) | Tray | Active | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 5.39" L x 2.76" W x 1.49" H (137.0mm x 70.0mm x 37.9mm) | Universal Input | PSK-60 | AC or DC | CE, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 102-PSK-60-48-DIN | EAR99 | 8504.40.9520 | 8 | 60W | 1 | 1.25A | 90% | 85 ~ 264 VAC | 48V | - | - | - | - | - | - | 100V | 370V | 4 kV | 62368-1 | |
![]() |
WDR-60-5 | 58.6000 | ![]() |
39 | 0.00000000 | MEAN WELL USA Inc. | WDR-60 (60W) | Box | Active | -30°C ~ 85°C (With Derating) | Laboratory | 4.02" L x 1.26" W x 4.93" H (102.0mm x 32.0mm x 125.2mm) | Adjustable Output | WDR-60 | AC or DC | CE, EAC, TUV, UL | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1866-WDR-60-5 | EAR99 | 8504.40.6018 | 28 | 50W | 1 | 10A | 83.5% | 180 ~ 550 VAC | 5V | - | - | - | - | - | No | 254V | 780V | 4.7 kV |