SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Features Base Product Number Input Type Approval Agency DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Current - Output (Max) Efficiency AC Voltage - Input Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required DC Voltage - Input (Min) DC Voltage - Input (Max) Voltage - Isolation Standard Number
TBLC 50-112 Traco Power TBLC 50-112 80.0700
RFQ
ECAD 10 0.00000000 Traco Power TBLC (50W) Box Active -25°C ~ 70°C (With Derating) Household Appliances, Industrial, ITE (Commercial) 2.15" L x 2.13" W x 3.52" H (54.6mm x 54.1mm x 89.4mm) Adjustable Output, IP20, Universal Input TBLC 50 AC CB, CE, cULus, cURus, SIQ download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 10 48W 1 4A 88% 85 ~ 264 VAC 12V - - - - - - 3 kV
TIS 150-124 SIG Traco Power TIS 150-124 SIG -
RFQ
ECAD 4242 0.00000000 Traco Power TIS (150W) Box Obsolete -25°C ~ 70°C (With Derating) Hazardous Locations, Industrial, ITE (Commercial) 6.18" L x 2.23" W x 4.51" H (157.0mm x 56.6mm x 114.6mm) Adjustable Output, IP20, Remote On/Off AC CB, CE, cCSAus, cULus, cURus download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9520 2 144W 1 6A 85% 93 ~ 132 VAC, 187 ~ 264 VAC 24V - - - - - -
TIS 300-148 SIG Traco Power TIS 300-148 SIG -
RFQ
ECAD 8828 0.00000000 Traco Power TIS (300W) Box Obsolete -25°C ~ 70°C (With Derating) Hazardous Locations, Industrial, ITE (Commercial) 8.15" L x 3.27" W x 4.51" H (207.0mm x 83.1mm x 114.6mm) Adjustable Output, IP20, Remote On/Off AC CB, CE, cCSAus, cULus, cURus download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9530 2 288W 1 6A 85% 93 ~ 132 VAC, 187 ~ 264 VAC 48V - - - - - -
TIS 500-124-230 Traco Power TIS 500-124-230 -
RFQ
ECAD 3419 0.00000000 Traco Power TIS (500W) Box Obsolete -25°C ~ 70°C (With Derating) Hazardous Locations, Industrial, ITE (Commercial) 8.66" L x 3.27" W x 5.12" H (220.0mm x 83.1mm x 130.0mm) Adjustable Output, IP20 AC CB, CE, cCSAus, cULus, cURus download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9530 2 480W 1 20A 90% 187 ~ 264 VAC 24V - - - - - -
TIS 50-124 Traco Power TIS 50-124 -
RFQ
ECAD 9968 0.00000000 Traco Power TIS (50W) Box Obsolete -25°C ~ 70°C (With Derating) Hazardous Locations, Industrial, ITE (Commercial) 2.95" L x 2.23" W x 3.94" H (74.9mm x 56.6mm x 100.1mm) Adjustable Output, IP20 AC CB, CE, cCSAus, cULus, cURus download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 2 48W 1 2A 85% 93 ~ 264 VAC 24V - - - - - -
TIS 600-124 Traco Power TIS 600-124 -
RFQ
ECAD 1320 0.00000000 Traco Power TIS (600W) Box Obsolete -25°C ~ 70°C (With Derating) Hazardous Locations, Industrial, ITE (Commercial) 9.57" L x 3.25" W x 6.98" H (243.1mm x 82.6mm x 177.3mm) Adjustable Output, IP20 AC CB, CE, cCSAus, cULus, cURus download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 2 576W 1 24A 90% 93 ~ 132 VAC, 187 ~ 264 VAC 24V - - - - - -
TIS 600-124 RED Traco Power TIS 600-124 RED -
RFQ
ECAD 7190 0.00000000 Traco Power TIS (600W) Box Obsolete -25°C ~ 70°C (With Derating) Hazardous Locations, Industrial, ITE (Commercial) 9.57" L x 3.25" W x 6.98" H (243.1mm x 82.6mm x 177.3mm) Adjustable Output, IP20, Load Sharing AC CB, CE, cCSAus, cULus, cURus download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 2 576W 1 24A 90% 93 ~ 132 VAC, 187 ~ 264 VAC 24V - - - - - -
TIS 75-148 Traco Power TIS 75-148 -
RFQ
ECAD 8630 0.00000000 Traco Power TIS (75W) Box Obsolete -25°C ~ 70°C (With Derating) Hazardous Locations, Industrial, ITE (Commercial) 3.54" L x 2.23" W x 4.51" H (89.9mm x 56.6mm x 114.6mm) Adjustable Output, IP20 AC CB, CE, cCSAus, cULus, cURus download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9520 2 72W 1 1.5A 85% 93 ~ 132 VAC, 187 ~ 264 VAC 48V - - - - - -
TPC 055-112 Traco Power TPC 055-112 86.7000
RFQ
ECAD 10 0.00000000 Traco Power TPC (55W) Box Active -25°C ~ 70°C (With Derating) Industrial, ITE (Commercial) 3.80" L x 1.77" W x 3.54" H (96.5mm x 45.0mm x 89.9mm) Adjustable Output, IP20, Universal Input TPC 055 AC or DC CB, CE, cCSAus, SIQ download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 10 42W 1 3.5A 87% 85 ~ 264 VAC 12V - - - - - - 90V 375V
TSP 090-124N Traco Power TSP 090-124N 158.5900
RFQ
ECAD 10 0.00000000 Traco Power TSP (90-96W) Box Active -25°C ~ 70°C (With Derating) Industrial, ITE (Commercial) 4.33" L x 1.38" W x 4.33" H (110.0mm x 35.1mm x 110.0mm) Adjustable Output, IP20, Remote On/Off, Universal Input TSP 090 AC CB, CE, cURus, SIQ download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9520 10 90W 1 3.75A 87% 85 ~ 264 VAC 24V - - - - - -
TSP240-124-3PAC500 Traco Power TSP240-124-3PAC500 -
RFQ
ECAD 2613 0.00000000 Traco Power TSP-3P (240W) Box Obsolete -25°C ~ 60°C Hazardous Locations, Industrial, ITE (Commercial) 4.33" L x 2.13" W x 4.33" H (110.0mm x 54.1mm x 110.0mm) IP20 AC CB, CE, SIQ download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9530 10 240W 1 10A 92% 400 ~ 550 VAC (3 Phase) 24V - - - - - -
TSPC 050-112 Traco Power TSPC 050-112 92.4800
RFQ
ECAD 1806 0.00000000 Traco Power TSPC (50W) Box Active -25°C ~ 70°C (With Derating) Hazardous Locations, Industrial, ITE (Commercial) 3.56" L x 1.45" W x 4.33" H (90.4mm x 36.8mm x 110.0mm) Adjustable Output, IP20, Universal Input TSPC 050 AC CB, CE download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 10 48W 1 4A 93% 85 ~ 264 VAC 12V - - - - - -
PS-S1005 Altech Corporation PS-S1005 -
RFQ
ECAD 9992 0.00000000 Altech Corporation PS-S10 (10W) Bulk Obsolete -20°C ~ 70°C (With Derating) Industrial, ITE (Commercial) 3.94" L x 0.89" W x 3.54" H (100.0mm x 22.5mm x 90.0mm) Adjustable Output, Universal Input AC or DC CE, cULus - ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.9510 1 10W 1 2A 77% 85 ~ 264 VAC 5V - - - - - No 120V 370V 3 kV 508; 60950-1
PS-S4012 Altech Corporation PS-S4012 -
RFQ
ECAD 2769 0.00000000 Altech Corporation PS-S40 (40W) Bulk Obsolete -20°C ~ 70°C (With Derating) Industrial, ITE (Commercial) 3.94" L x 1.57" W x 3.54" H (100.0mm x 40.0mm x 90.0mm) Adjustable Output, Universal Input AC or DC CE, cULus - ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.9510 1 40W 1 3.33A 86% 85 ~ 264 VAC 12V - - - - - No 120V 370V 3 kV 508; 60950-1
IS.AC24VDC5ADIN Industrial Shields IS.AC24VDC5ADIN 111.6200
RFQ
ECAD 1 0.00000000 Industrial Shields - Box Active - ITE (Commercial) - Universal Input IS.AC24 AC - - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 2198-IS.AC24VDC5ADIN EAR99 8504.40.9520 1 120W 1 5A - 90 ~ 264 VAC 24V - - - - - -
DSR240PS24 XP Power DSR240PS24 124.0000
RFQ
ECAD 16 0.00000000 XP Power DSR240 (240W) Box Active -25°C ~ 70°C ITE (Commercial) 4.88" L x 1.77" W x 4.69" H (124.0mm x 45.0mm x 119.1mm) Universal Input DSR240 AC - download ROHS3 Compliant Not Applicable EAR99 8504.40.9530 1 240W 1 10A 94% 85 ~ 264 VAC 24V - - - - - - 62368-1
DNR480PS24 XP Power DNR480PS24 -
RFQ
ECAD 1889 0.00000000 XP Power DNR (480W) Box Active -40°C ~ 70°C (With Derating) Hazardous Locations, Industrial, ITE (Commercial) 6.89" L x 4.57" W x 4.92" H (175.0mm x 116.0mm x 125.0mm) Adjustable Output, Standby Output, Universal Input DNR480 AC or DC CE download ROHS3 Compliant Not Applicable EAR99 8504.40.9530 1 480W 1 20A 89% 90 ~ 264 VAC 24V - - - - - No 120V 375V 3 kV
DRB240-24-1 TDK-Lambda Americas Inc DRB240-24-1 109.2600
RFQ
ECAD 1416 0.00000000 TDK-Lambda Americas Inc DRB (120-480W) Bulk Active -20°C ~ 70°C (With Derating) Industrial, ITE (Commercial) 4.92" L x 1.61" W x 4.88" H (125.0mm x 41.0mm x 124.0mm) Adjustable Output, PFC, Universal Input DRB240 AC CE, cULus, cURus, EAC download RoHS Compliant Not Applicable REACH Unaffected EAR99 8504.40.9530 1 240W 1 10A 93% 85 ~ 265 VAC 24V - - - - - - 3 kV
PDQE10-Q24-D5-DIN CUI Inc. PDQE10-Q24-D5-DIN 29.7700
RFQ
ECAD 1 0.00000000 CUI Inc. PDQE10 (10W) Tray Active -40°C ~ 85°C (With Derating) ITE (Commercial) 2.99" L x 1.24" W x 0.87" H (76.0mm x 31.5mm x 22.2mm) Remote On/Off PDQE10 DC CB Scheme, IEC, UL download RoHS Compliant Not Applicable REACH Unaffected 102-4826 EAR99 8504.40.9580 24 10W 2 1A, 1A 83% 5V -5V - - - - - 9V 36V 1.5 kV 60950-1
PDQE10-Q24-S9-DIN CUI Inc. PDQE10-Q24-S9-DIN 28.8900
RFQ
ECAD 18 0.00000000 CUI Inc. PDQE10 (10W) Tray Active -40°C ~ 85°C (With Derating) ITE (Commercial) 2.99" L x 1.24" W x 0.87" H (76.0mm x 31.5mm x 22.2mm) Remote On/Off PDQE10 DC EN download RoHS Compliant Not Applicable REACH Unaffected 102-4833 EAR99 8504.40.9580 24 10W 1 1.111A 86% 9V - - - - - - 9V 36V 1.5 kV 55024; 55032 Class A
PDQE10-Q48-S5-DIN CUI Inc. PDQE10-Q48-S5-DIN 29.1600
RFQ
ECAD 9252 0.00000000 CUI Inc. PDQE10 (10W) Tray Active -40°C ~ 85°C (With Derating) ITE (Commercial) 2.99" L x 1.24" W x 0.87" H (76.0mm x 31.5mm x 22.2mm) Remote On/Off PDQE10 DC EN download RoHS Compliant Not Applicable REACH Unaffected 102-4851 EAR99 8504.40.9580 24 10W 1 2A 83% 5V - - - - - - 18V 75V 1.5 kV 55024; 55032 Class A
SPD121001 Carlo Gavazzi Inc. SPD121001 396.0000
RFQ
ECAD 6 0.00000000 Carlo Gavazzi Inc. SPD (100W) Box Obsolete -35°C ~ 71°C (With Derating) Hazardous Locations, Industrial, ITE (Commercial) 4.49" L x 1.59" W x 3.54" H (114.0mm x 40.5mm x 90.0mm) Adjustable Output, IP20, PFC, Universal Input SPD12 AC or DC CE, cULus, TUV download Not Applicable REACH Unaffected EAR99 8504.40.9520 1 101W 1 8.4A 84% 90 ~ 264 VAC 12V - - - - - No 120V 375V 3 kV
SPD121002 Carlo Gavazzi Inc. SPD121002 498.0000
RFQ
ECAD 9 0.00000000 Carlo Gavazzi Inc. SPD (100W) Box Obsolete -25°C ~ 71°C (With Derating) Hazardous Locations, Industrial, ITE (Commercial) 4.49" L x 2.13" W x 3.54" H (114.0mm x 54.0mm x 90.0mm) Adjustable Output, IP20, PFC SPD12 AC or DC CE, cULus, TUV download Not Applicable REACH Unaffected EAR99 8504.40.9520 1 101W 1 8.4A 86% 340 ~ 575 VAC (2 Phase) 12V - - - - - No 480V 820V 3 kV
TIB 080-148EX Traco Power TIB 080-148EX 109.4100
RFQ
ECAD 8887 0.00000000 Traco Power TIB 080EX (80W) Box Active -40°C ~ 70°C (With Derating) Hazardous Locations, Industrial, ITE (Commercial) 3.71" L x 1.26" W x 4.50" H (94.2mm x 32.0mm x 114.2mm) Adjustable Output, PFC, Universal Input TIB 080 AC CB, CE, cULus, cURus, SIQ download ROHS3 Compliant Not Applicable REACH Unaffected 1951-3306 EAR99 8504.40.9520 10 82W 1 1.7A 90% 85 ~ 264 VAC 48V - - - - - - 4.25 kV
TIB 120-124EX Traco Power TIB 120-124EX 128.8600
RFQ
ECAD 5 0.00000000 Traco Power TIB 120EX (120W) Box Active -40°C ~ 70°C (With Derating) Hazardous Locations, Industrial, ITE (Commercial) 4.50" L x 1.42" W x 4.89" H (114.2mm x 36.0mm x 124.2mm) Adjustable Output, PFC, Universal Input TIB 120 AC CB, CE, cULus, cURus, SIQ download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9520 10 120W 1 5A 94% 85 ~ 264 VAC 24V - - - - - - 4.25 kV
TIB 240-148EX Traco Power TIB 240-148EX 186.2600
RFQ
ECAD 8724 0.00000000 Traco Power TIB 240EX (240W) Box Active -40°C ~ 70°C (With Derating) Hazardous Locations, Industrial, ITE (Commercial) 4.50" L x 1.89" W x 4.89" H (114.2mm x 48.0mm x 124.2mm) Adjustable Output, PFC, Universal Input TIB 240 AC CB, CE, cULus, cURus, SIQ download ROHS3 Compliant Not Applicable REACH Unaffected 1951-3311 EAR99 8504.40.9530 10 240W 1 5A 95% 85 ~ 264 VAC 48V - - - - - - 4.25 kV
TIB 080-112 Traco Power TIB 080-112 98.8000
RFQ
ECAD 18 0.00000000 Traco Power TIB 080 (80W) Box Active -40°C ~ 70°C (With Derating) Industrial, ITE (Commercial) 3.71" L x 1.26" W x 4.50" H (94.2mm x 32.0mm x 114.2mm) Adjustable Output, PFC, Universal Input TIB 080 AC CB, CE, cULus, cURus, SIQ download ROHS3 Compliant Not Applicable REACH Unaffected 1951-3314 EAR99 8504.40.9520 10 80W 1 6.7A 88% 85 ~ 264 VAC 12V - - - - - - 4.25 kV
2904617 Phoenix Contact 2904617 560.2800
RFQ
ECAD 7489 0.00000000 Phoenix Contact Quint Bulk Active -40°C ~ 75°C (With Derating) Hazardous Locations, Industrial, ITE (Commercial) 4.80" L x 2.76" W x 5.12" H (122.0mm x 70.0mm x 130.0mm) Adjustable Output, IP20 AC or DC cUL, cULus, EAC, UL, UR download RoHS Compliant Not Applicable EAR99 8504.40.9530 1 480W 1 20A 94.2% 100 ~ 240 VAC 24V - - - - - - 110V 250V 4 kV
PSK-60-48-DIN CUI Inc. PSK-60-48-DIN 25.6900
RFQ
ECAD 6 0.00000000 CUI Inc. PSK-60 (60W) Tray Active -40°C ~ 70°C (With Derating) ITE (Commercial) 5.39" L x 2.76" W x 1.49" H (137.0mm x 70.0mm x 37.9mm) Universal Input PSK-60 AC or DC CE, cURus download ROHS3 Compliant Not Applicable REACH Unaffected 102-PSK-60-48-DIN EAR99 8504.40.9520 8 60W 1 1.25A 90% 85 ~ 264 VAC 48V - - - - - - 100V 370V 4 kV 62368-1
WDR-60-5 MEAN WELL USA Inc. WDR-60-5 58.6000
RFQ
ECAD 39 0.00000000 MEAN WELL USA Inc. WDR-60 (60W) Box Active -30°C ~ 85°C (With Derating) Laboratory 4.02" L x 1.26" W x 4.93" H (102.0mm x 32.0mm x 125.2mm) Adjustable Output WDR-60 AC or DC CE, EAC, TUV, UL download ROHS3 Compliant Not Applicable REACH Unaffected 1866-WDR-60-5 EAR99 8504.40.6018 28 50W 1 10A 83.5% 180 ~ 550 VAC 5V - - - - - No 254V 780V 4.7 kV
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse