Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Base Product Number | Approval Agency | Voltage - Input (Max) | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Current - Output (Max) | Voltage - Input (Min) | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Isolation |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TEP 150-7216WI | 249.3700 | 5170 | 0.00000000 | Traco Power | TEP 150WI (150W) | Box | Active | -40°C ~ 75°C | ITE (Commercial), Railway | 3.86" L x 2.07" W x 1.60" H (98.0mm x 52.6mm x 40.6mm) | Chassis Mount | Enclosed | TEP 150 | CB, cURus | 160V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 151W | 1 | 5.4A | 43V | 89% | 28V | - | - | - | 2.25 kV | |||
TEP 150-7218WI-F | 335.4800 | 5040 | 0.00000000 | Traco Power | TEP 150WI-F (150W) | Box | Active | -40°C ~ 75°C | ITE (Commercial), Railway | 6.32" L x 2.07" W x 1.60" H (160.5mm x 52.6mm x 40.6mm) | Chassis Mount | Enclosed | TEP 150 | CB, CE, cURus | 160V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 154W | 1 | 3.2A | 43V | 88% | 48V | - | - | - | 2.25 kV | |||
TEP 200-2413WIRCMF | 429.7700 | 1 | 0.00000000 | Traco Power | TEP 200WIRCMF (200W) | Box | Active | -40°C ~ 75°C | ITE (Commercial), Railway | 3.35" L x 2.40" W x 1.53" H (85.1mm x 61.0mm x 38.9mm) | Chassis Mount | Open Frame | TEP 200 | CB, CE, cURus | 36V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 180W | 1 | 12A | 9V | 90% | 15V | - | - | - | 3 kV | |||
TEP 200-2415WIRCMF | 429.7700 | 172 | 0.00000000 | Traco Power | TEP 200WIRCMF (200W) | Box | Active | -40°C ~ 75°C | ITE (Commercial), Railway | 3.35" L x 2.40" W x 1.53" H (85.1mm x 61.0mm x 38.9mm) | Chassis Mount | Open Frame | TEP 200 | CB, CE, cURus | 36V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 180W | 1 | 7.5A | 9V | 90% | 24V | - | - | - | 3 kV | |||
TEP 200-2416WIRCMF | 429.7700 | 6829 | 0.00000000 | Traco Power | TEP 200WIRCMF (200W) | Box | Active | -40°C ~ 75°C | ITE (Commercial), Railway | 3.35" L x 2.40" W x 1.53" H (85.1mm x 61.0mm x 38.9mm) | Chassis Mount | Open Frame | TEP 200 | CB, CE, cURus | 36V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 182W | 1 | 6.5A | 9V | 90% | 28V | - | - | - | 3 kV | |||
TEP 200-4812WIRCMF | 429.7700 | 15 | 0.00000000 | Traco Power | TEP 200WIRCMF (200W) | Box | Active | -40°C ~ 75°C | ITE (Commercial), Railway | 3.35" L x 2.40" W x 1.53" H (85.1mm x 61.0mm x 38.9mm) | Chassis Mount | Open Frame | TEP 200 | CB, CE, cURus | 75V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 216W | 1 | 18A | 18V | 90% | 12V | - | - | - | 3 kV | |||
TEP 200-4818WIRCMF | 429.7700 | 1 | 0.00000000 | Traco Power | TEP 200WIRCMF (200W) | Box | Active | -40°C ~ 75°C | ITE (Commercial), Railway | 3.35" L x 2.40" W x 1.53" H (85.1mm x 61.0mm x 38.9mm) | Chassis Mount | Open Frame | TEP 200 | CB, CE, cURus | 75V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 216W | 1 | 4.5A | 18V | 90% | 48V | - | - | - | 3 kV | |||
TEP 75-2411WI-CMF | 228.9000 | 8421 | 0.00000000 | Traco Power | TEP 75WICMF (75W) | Box | Active | -40°C ~ 75°C | ITE (Commercial), Railway | 3.35" L x 2.40" W x 1.53" H (85.1mm x 61.0mm x 38.9mm) | Chassis Mount | Open Frame | TEP 75 | CB, CE, cURus | 36V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 75W | 1 | 15A | 9V | 88% | 5V | - | - | - | 3 kV | |||
TEP 75-2412WI-CMF | 226.7400 | 8432 | 0.00000000 | Traco Power | TEP 75WICMF (75W) | Box | Active | -40°C ~ 75°C | ITE (Commercial), Railway | 3.35" L x 2.40" W x 1.53" H (85.1mm x 61.0mm x 38.9mm) | Chassis Mount | Open Frame | TEP 75 | CB, CE, cURus | 36V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 76W | 1 | 6.3A | 9V | 88% | 12V | - | - | - | 3 kV | |||
TEP 75-2413WI-CMF | 228.9000 | 1 | 0.00000000 | Traco Power | TEP 75WICMF (75W) | Box | Active | -40°C ~ 75°C | ITE (Commercial), Railway | 3.35" L x 2.40" W x 1.53" H (85.1mm x 61.0mm x 38.9mm) | Chassis Mount | Open Frame | TEP 75 | CB, CE, cURus | 36V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 75W | 1 | 5A | 9V | 88% | 15V | - | - | - | 3 kV | |||
TEP 75-2415WI-CMF | 226.7400 | 3798 | 0.00000000 | Traco Power | TEP 75WICMF (75W) | Box | Active | -40°C ~ 75°C | ITE (Commercial), Railway | 3.35" L x 2.40" W x 1.53" H (85.1mm x 61.0mm x 38.9mm) | Chassis Mount | Open Frame | TEP 75 | CB, CE, cURus | 36V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 77W | 1 | 3.2A | 9V | 87% | 24V | - | - | - | 3 kV | |||
TEP 75-4818WI-CMF | 226.7400 | 2129 | 0.00000000 | Traco Power | TEP 75WICMF (75W) | Box | Active | -40°C ~ 75°C | ITE (Commercial), Railway | 3.35" L x 2.40" W x 1.53" H (85.1mm x 61.0mm x 38.9mm) | Chassis Mount | Open Frame | TEP 75 | CB, CE, cURus | 75V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 77W | 1 | 1.6A | 18V | 87% | 48V | - | - | - | 3 kV | |||
TEP 75-7211WI-CMF | 266.3200 | 2493 | 0.00000000 | Traco Power | TEP 75WICMF (75W) | Box | Active | -40°C ~ 75°C | ITE (Commercial), Railway | 3.35" L x 2.40" W x 1.53" H (85.1mm x 61.0mm x 38.9mm) | Chassis Mount | Open Frame | TEP 75 | CB, CE, cURus | 160V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 75W | 1 | 15A | 43V | 91% | 5V | - | - | - | 3 kV | |||
TEP 75-7215WI-CMF | 253.9900 | 2 | 0.00000000 | Traco Power | TEP 75WICMF (75W) | Box | Active | -40°C ~ 75°C | ITE (Commercial), Railway | 3.35" L x 2.40" W x 1.53" H (85.1mm x 61.0mm x 38.9mm) | Chassis Mount | Open Frame | TEP 75 | CB, CE, cURus | 160V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 77W | 1 | 3.2A | 43V | 90% | 24V | - | - | - | 3 kV | |||
TEQ 100-2412WIR | 387.8000 | 2 | 0.00000000 | Traco Power | TEQ 100WIR (100W) | Box | Active | -40°C ~ 105°C | Industrial, ITE (Commercial), Railway | 4.06" L x 3.50" W x 3.45" H (103.1mm x 88.9mm x 87.6mm) | Chassis Mount | Enclosed | TEQ 100 | CB, cULus, cURus | 36V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 2 | 101W | 1 | 8.4A | 10V | 90% | 12V | - | - | - | 2.25 kV | |||
TEQ 100-4816WIR | 387.8000 | 5664 | 0.00000000 | Traco Power | TEQ 100WIR (100W) | Box | Active | -40°C ~ 105°C | Industrial, ITE (Commercial), Railway | 4.06" L x 3.50" W x 3.45" H (103.1mm x 88.9mm x 87.6mm) | Chassis Mount | Enclosed | TEQ 100 | CB, cULus, cURus | 75V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 2 | 101W | 1 | 3.6A | 19V | 90% | 28V | - | - | - | 2.25 kV | |||
TEQ 100-7212WIR | 408.6600 | 2 | 0.00000000 | Traco Power | TEQ 100WIR (100W) | Box | Active | -40°C ~ 105°C | Industrial, ITE (Commercial), Railway | 4.06" L x 3.50" W x 3.45" H (103.1mm x 88.9mm x 87.6mm) | Chassis Mount | Enclosed | TEQ 100 | CB, cULus, cURus | 160V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 2 | 101W | 1 | 8.4A | 43V | 89% | 12V | - | - | - | 2.25 kV | |||
TEQ 100-7218WIR | 408.6600 | 6022 | 0.00000000 | Traco Power | TEQ 100WIR (100W) | Box | Active | -40°C ~ 105°C | Industrial, ITE (Commercial), Railway | 4.06" L x 3.50" W x 3.45" H (103.1mm x 88.9mm x 87.6mm) | Chassis Mount | Enclosed | TEQ 100 | CB, cULus, cURus | 160V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 2 | 101W | 1 | 2.1A | 43V | 90% | 48V | - | - | - | 2.25 kV | |||
TEQ 160-4812WIR | 444.0500 | 8659 | 0.00000000 | Traco Power | TEQ 160WIR (160W) | Box | Active | -40°C ~ 105°C | Industrial, ITE (Commercial), Railway | 4.06" L x 3.50" W x 3.45" H (103.1mm x 88.9mm x 87.6mm) | Chassis Mount | Enclosed | TEQ 160 | CB, cULus, cURus | 75V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 2 | 156W | 1 | 13A | 19V | 90% | 12V | - | - | - | 2.25 kV | |||
TEQ 160-4816WIR | 444.0500 | 5046 | 0.00000000 | Traco Power | TEQ 160WIR (160W) | Box | Active | -40°C ~ 105°C | Industrial, ITE (Commercial), Railway | 4.06" L x 3.50" W x 3.45" H (103.1mm x 88.9mm x 87.6mm) | Chassis Mount | Enclosed | TEQ 160 | CB, cULus, cURus | 75V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 2 | 154W | 1 | 5.5A | 19V | 90% | 28V | - | - | - | 2.25 kV | |||
TEQ 200-4812WIR | 477.7500 | 1 | 0.00000000 | Traco Power | TEQ 20WIR (20W) | Box | Active | -40°C ~ 105°C | Industrial, ITE (Commercial), Railway | 4.06" L x 3.50" W x 3.45" H (103.1mm x 88.9mm x 87.6mm) | Chassis Mount | Enclosed | TEQ 200 | CB, cULus, cURus | 75V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 216W | 1 | 18A | 19V | 89% | 12V | - | - | - | 2.25 kV | |||
TEQ 200-4818WIR | 477.7500 | 9673 | 0.00000000 | Traco Power | TEQ 20WIR (20W) | Box | Active | -40°C ~ 105°C | Industrial, ITE (Commercial), Railway | 4.06" L x 3.50" W x 3.45" H (103.1mm x 88.9mm x 87.6mm) | Chassis Mount | Enclosed | TEQ 200 | CB, cULus, cURus | 75V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 216W | 1 | 4.5A | 19V | 89% | 48V | - | - | - | 2.25 kV | |||
TEQ 200-7212WIR | 511.2500 | 7221 | 0.00000000 | Traco Power | TEQ 20WIR (20W) | Box | Active | -40°C ~ 105°C | Industrial, ITE (Commercial), Railway | 4.06" L x 3.50" W x 3.45" H (103.1mm x 88.9mm x 87.6mm) | Chassis Mount | Enclosed | TEQ 200 | CB, cULus, cURus | 160V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 240W | 1 | 20A | 43V | 88% | 12V | - | - | - | 2.25 kV | |||
TEQ 200-7216WIR | 511.2500 | 7736 | 0.00000000 | Traco Power | TEQ 20WIR (20W) | Box | Active | -40°C ~ 105°C | Industrial, ITE (Commercial), Railway | 4.06" L x 3.50" W x 3.45" H (103.1mm x 88.9mm x 87.6mm) | Chassis Mount | Enclosed | TEQ 200 | CB, cULus, cURus | 160V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 238W | 1 | 8.5A | 43V | 89% | 28V | - | - | - | 2.25 kV | |||
TEQ 300-4816WIR | 672.0000 | 7890 | 0.00000000 | Traco Power | TEQ 300WIR (300W) | Box | Active | -40°C ~ 80°C | Industrial, ITE (Commercial), Railway | 6.00" L x 4.00" W x 1.52" H (152.4mm x 101.6mm x 38.6mm) | Chassis Mount | Enclosed | TEQ 300 | CB, CE, cULus, cURus | 75V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 302W | 1 | 10.8A | 18V | 91% | 28V | - | - | - | 3 kV | |||
TEQ 300-4818WIR | 672.0000 | 7 | 0.00000000 | Traco Power | TEQ 300WIR (300W) | Box | Active | -40°C ~ 80°C | Industrial, ITE (Commercial), Railway | 6.00" L x 4.00" W x 1.52" H (152.4mm x 101.6mm x 38.6mm) | Chassis Mount | Enclosed | TEQ 300 | CB, CE, cULus, cURus | 75V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 302W | 1 | 6.3A | 18V | 92% | 48V | - | - | - | 3 kV | |||
TEQ 300-7215WIR | 731.8500 | 7360 | 0.00000000 | Traco Power | TEQ 300WIR (300W) | Box | Active | -40°C ~ 80°C | Industrial, ITE (Commercial), Railway | 6.00" L x 4.00" W x 1.52" H (152.4mm x 101.6mm x 38.6mm) | Chassis Mount | Enclosed | TEQ 300 | CB, CE, cULus, cURus | 160V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 300W | 1 | 12.5A | 43V | 91% | 24V | - | - | - | 3 kV | |||
TMDC 20-2418 | 66.8600 | 8 | 0.00000000 | Traco Power | TMDC 20 (20W) | Box | Active | -40°C ~ 90°C (With Derating) | ITE (Commercial) | 3.78" L x 2.13" W x 0.92" H (96.0mm x 54.1mm x 23.4mm) | Chassis Mount | Enclosed | TMDC 20 | CB, CE, cURus | 36V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 10 | 20W | 1 | 420mA | 9V | 89% | 48V | - | - | - | 2.5 kV | |||
TMDC 20-4812 | 68.0300 | 181 | 0.00000000 | Traco Power | TMDC 20 (20W) | Box | Active | -40°C ~ 90°C (With Derating) | ITE (Commercial) | 3.78" L x 2.13" W x 0.92" H (96.0mm x 54.1mm x 23.4mm) | Chassis Mount | Enclosed | TMDC 20 | CB, CE, cURus | 75V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 10 | 20W | 1 | 1.67A | 18V | 91% | 12V | - | - | - | 2.5 kV | |||
TMDC 20-4815 | 67.3800 | 6 | 0.00000000 | Traco Power | TMDC 20 (20W) | Box | Active | -40°C ~ 90°C (With Derating) | ITE (Commercial) | 3.78" L x 2.13" W x 0.92" H (96.0mm x 54.1mm x 23.4mm) | Chassis Mount | Enclosed | TMDC 20 | CB, CE, cURus | 75V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 10 | 20W | 1 | 835mA | 18V | 91% | 24V | - | - | - | 2.5 kV |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse