Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Base Product Number | Approval Agency | Voltage - Input (Max) | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Current - Output (Max) | Voltage - Input (Min) | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Isolation | Standard Number |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CQ1001-7R | - | ![]() |
3424 | 0.00000000 | Bel Power Solutions | Melcher Q (66 ~ 132W) | Bulk | Active | -25°C ~ 71°C | ITE (Commercial), Railway | 6.73" L x 4.37" W x 0.78" H (171.0mm x 111.0mm x 19.8mm) | Chassis Mount | Enclosed, Conformal Coated | CQ1001 | CE, CSA, EN, IEC, TUV, UL | 75V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9580 | 10 | 102W | 1 | 20A | 33.6V | 87% | 5.1V | - | - | - | ||||
![]() |
VI-PCW20-CVY | - | ![]() |
5910 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VI-PCW20 | - | Not Applicable | REACH Affected | EAR99 | 8504.40.9580 | 1 | |||||||||||||||||||||
![]() |
VE-PW33-IVV | - | ![]() |
9144 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VE-PW33 | - | Not Applicable | REACH Affected | EAR99 | 8504.40.9580 | 1 | |||||||||||||||||||||
![]() |
VI-RN011-MUXX | - | ![]() |
2650 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VI-RN011 | - | Not Applicable | REACH Affected | EAR99 | 8504.40.9580 | 1 | |||||||||||||||||||||
![]() |
VI-RC1001-CYYY | - | ![]() |
6542 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VI-RC1001 | - | Not Applicable | EAR99 | 8504.40.9580 | 1 | ||||||||||||||||||||||
![]() |
1/2A24-P30-25PPM-F-C | 1.0000 | ![]() |
3519 | 0.00000000 | Advanced Energy | Ultravolt® A | Bulk | Active | 10°C ~ 45°C | ITE (Commercial) | 4.75" L x 2.00" W x 1.00" H (120.7mm x 50.8mm x 25.4mm) | Chassis Mount | Enclosed | 1/2A24 | CE, cURus | 30V | download | ROHS3 Compliant | Not Applicable | 633-1/2A24-P30-25PPM-F-C | EAR99 | 8504.40.9580 | 1 | 30W | 1 | 60mA | 23V | - | 500V | - | - | - | 60950-1; 62368-1 | |||
![]() |
VI-LJ41-EY | - | ![]() |
9340 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VI-LJ41 | - | RoHS non-compliant | Not Applicable | REACH Affected | EAR99 | 8504.40.9580 | 1 | ||||||||||||||||||||
![]() |
VI-LCW3-CY-H1 | - | ![]() |
3561 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VI-LCW3 | - | Not Applicable | EAR99 | 8504.40.9580 | 1 | ||||||||||||||||||||||
![]() |
VI-L34-IV | - | ![]() |
6782 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VI-L34 | - | Not Applicable | EAR99 | 8504.40.9580 | 1 | ||||||||||||||||||||||
![]() |
MP2412-150 | 2.0000 | ![]() |
3 | 0.00000000 | Prodrive Technologies | MP | Retail Package | Active | -40°C ~ 75°C | ITE (Commercial) | - | Chassis Mount | Enclosed, Bidirectional | - | 36V | - | 4881-MP2412-150 | 1 | 1.8kW | 1 | 150A | 20V | 95% | 8 ~ 16V | - | - | - | - | ||||||||
![]() |
VI-PJN23-EZZ | - | ![]() |
5143 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VI-PJN23 | - | Not Applicable | REACH Affected | EAR99 | 8504.40.9580 | 1 | |||||||||||||||||||||
![]() |
15C24-P60-I10-AD | 1.0000 | ![]() |
7698 | 0.00000000 | Advanced Energy | * | Bulk | Active | 15C24 | - | ROHS3 Compliant | Not Applicable | 633-15C24-P60-I10-AD | EAR99 | 8504.40.9580 | 1 | ||||||||||||||||||||
![]() |
VI-P5X3-EWY | - | ![]() |
9941 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VI-P5X3 | - | Not Applicable | EAR99 | 8504.40.9580 | 1 | ||||||||||||||||||||||
![]() |
20C24-P125-I10-H | 2.0000 | ![]() |
8175 | 0.00000000 | Advanced Energy | * | Bulk | Active | 20C24 | - | ROHS3 Compliant | Not Applicable | 633-20C24-P125-I10-H | EAR99 | 8504.40.9580 | 1 | ||||||||||||||||||||
![]() |
MI-NC62-IS | - | ![]() |
5257 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | MI-NC62 | - | Not Applicable | REACH Affected | EAR99 | 8504.40.9580 | 1 | |||||||||||||||||||||
![]() |
VI-MCNL-ES | - | ![]() |
1484 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VI-MCNL | - | Not Applicable | REACH Affected | EAR99 | 8504.40.9580 | 1 | |||||||||||||||||||||
![]() |
1010643 | 137.0400 | ![]() |
50 | 0.00000000 | Integrated Power Designs | DC4-110 (110W) | Box | Active | 0°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 5.00" L x 3.00" W x 1.32" H (127.0mm x 76.2mm x 33.5mm) | Chassis Mount | Open Frame | CE, cURus, TUV, UKCA | 72V | download | ROHS3 Compliant | 1 (Unlimited) | EAR99 | 8504.40.6007 | 1 | 110W | 1 | 7.3A | 36V | 82% | 15V | - | - | - | 60601-1; 62368-1 | |||||
![]() |
MI-P502-MYY | - | ![]() |
6535 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | MI-P502 | - | Not Applicable | REACH Affected | EAR99 | 8504.40.9580 | 1 | |||||||||||||||||||||
![]() |
VE-RU1N3-EWYW | - | ![]() |
4305 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VE-RU1N3 | - | Not Applicable | EAR99 | 8504.40.9580 | 1 | ||||||||||||||||||||||
![]() |
VI-L74-IW | - | ![]() |
5272 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VI-L74 | - | Not Applicable | REACH Affected | EAR99 | 8504.40.9580 | 1 | |||||||||||||||||||||
![]() |
VI-MCN3-EU-H1 | - | ![]() |
2306 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VI-MCN3 | - | Not Applicable | REACH Affected | EAR99 | 8504.40.9580 | 1 | |||||||||||||||||||||
![]() |
VI-Q030-CVY | - | ![]() |
1167 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VI-Q030 | - | Not Applicable | EAR99 | 8504.40.9580 | 1 | ||||||||||||||||||||||
![]() |
VI-LC62-CU | - | ![]() |
3430 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VI-LC62 | - | Not Applicable | REACH Affected | EAR99 | 8504.40.9580 | 1 | |||||||||||||||||||||
![]() |
VI-PJW00-EZZ | - | ![]() |
8522 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VI-PJW00 | - | Not Applicable | EAR99 | 8504.40.9580 | 1 | ||||||||||||||||||||||
![]() |
TMDC 10-2422 | 57.1400 | ![]() |
3715 | 0.00000000 | Traco Power | TMDC 10 (10W) | Tube | Active | -40°C ~ 92.5°C (With Derating) | ITE (Commercial) | 3.11" L x 1.34" W x 0.87" H (79.0mm x 34.0mm x 22.0mm) | Chassis Mount | Enclosed | TMDC 10 | CB, CE, cURus | 36V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 10 | 10W | 2 | 416mA, 416mA | 9V | 86% | 12V | -12V | - | - | 3 kV | |||
![]() |
50C24-P250-I5-AQ-WS-DAR-H | 3.0000 | ![]() |
6321 | 0.00000000 | Advanced Energy | * | Bulk | Active | 50C24 | - | ROHS3 Compliant | Not Applicable | 633-50C24-P250-I5-AQ-WS-DAR-H | EAR99 | 8504.40.9580 | 1 | ||||||||||||||||||||
![]() |
VI-PJ722-CYY | - | ![]() |
8983 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VI-PJ722 | - | Not Applicable | EAR99 | 8504.40.9580 | 1 | ||||||||||||||||||||||
![]() |
MI-NC20-IS | - | ![]() |
3064 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | MI-NC20 | - | Not Applicable | REACH Affected | EAR99 | 8504.40.9580 | 1 | |||||||||||||||||||||
![]() |
VI-RJ6022-IXWW | - | ![]() |
7907 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VI-RJ6022 | - | Not Applicable | REACH Affected | EAR99 | 8504.40.9580 | 1 | |||||||||||||||||||||
![]() |
50C24-N125-I5-WS-H | 2.0000 | ![]() |
7447 | 0.00000000 | Advanced Energy | * | Bulk | Active | 50C24 | - | ROHS3 Compliant | Not Applicable | 633-50C24-N125-I5-WS-H | EAR99 | 8504.40.9580 | 1 |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse