Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Base Product Number Approval Agency Voltage - Input (Max) DataSheet RoHS Status Moisture Sensitivity Level (MSL) ECCN HTSUS Standard Package Power (Watts) Number of Outputs Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Standard Number
1010624 Integrated Power Designs 1010624 137.0400
RFQ
ECAD 9 0.00000000 Integrated Power Designs DC2-110 (110W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 5.00" L x 3.00" W x 1.32" H (127.0mm x 76.2mm x 33.5mm) Chassis Mount Open Frame CE, cURus, TUV, UKCA 36V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 110W 1 2.3A 18V 82% 48V - - - 60601-1; 62368-1
1010692 Integrated Power Designs 1010692 198.2100
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-150 (150W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 6.00" L x 3.83" W x 1.32" H (152.4mm x 97.3mm x 33.5mm) Chassis Mount Open Frame CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 135W 2 15A, 5A 36V 82% 5V 12V - - 60601-1; 62368-1
1010730CHCO Integrated Power Designs 1010730CHCO 240.9000
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-185 (185W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 7.23" L x 4.36" W x 1.74" H (183.6mm x 110.7mm x 44.2mm) Chassis Mount Enclosed 1010730 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 185W 2 20A, 8A 36V 84% 5V 12V - - 60601-1; 62368-1
1010793 Integrated Power Designs 1010793 108.7600
RFQ
ECAD 114 0.00000000 Integrated Power Designs DC4-70 (70W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.50" L x 2.50" W x 1.22" H (114.3mm x 63.5mm x 31.0mm) Chassis Mount Open Frame CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 70W 1 2.5A 36V 78% 28V - - - 60601-1; 62368-1
1010694CHCO Integrated Power Designs 1010694CHCO 211.5500
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-150 (150W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) Chassis Mount Enclosed 1010694 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 147W 2 7.5A, 5A 36V 82% 12V 2V - - 60601-1; 62368-1
1011531CH Integrated Power Designs 1011531CH 116.8200
RFQ
ECAD 7876 0.00000000 Integrated Power Designs DC1-80 (80W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.70" L x 2.70" W x 1.48" H (119.4mm x 68.9mm x 37.6mm) Chassis Mount Chassis 1011531 CE, cURus, TUV, UKCA 18V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 80W 2 3.5A, 3.5A 9V 82% 12V -12V - - 60601-1; 62368-1
1010667 Integrated Power Designs 1010667 165.5200
RFQ
ECAD 1 0.00000000 Integrated Power Designs DC2-150 (150W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 6.00" L x 3.83" W x 1.32" H (152.4mm x 97.3mm x 33.5mm) Chassis Mount Open Frame CE, cURus, TUV, UKCA 36V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 150W 1 5.4A 18V 82% 28V - - - 60601-1; 62368-1
1010810CHCO Integrated Power Designs 1010810CHCO 122.1000
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC2-70 (70W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.79" L x 2.62" W x 1.48" H (121.6mm x 66.5mm x 37.6mm) Chassis Mount Enclosed 1010810 CE, cURus, TUV, UKCA 36V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 46W 1 14A 18V 78% 3.3V - - - 60601-1; 62368-1
1010700CHCO Integrated Power Designs 1010700CHCO 225.9800
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-150 (150W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) Chassis Mount Enclosed 1010700 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 150W 4 15A, 8A, 2A, 2A 36V 82% 5V 3.3V 15V -15V 60601-1; 62368-1
1010664 Integrated Power Designs 1010664 165.5200
RFQ
ECAD 5 0.00000000 Integrated Power Designs DC2-150 (150W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 6.00" L x 3.83" W x 1.32" H (152.4mm x 97.3mm x 33.5mm) Chassis Mount Open Frame CE, cURus, TUV, UKCA 36V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 150W 1 12.5A 18V 82% 12V - - - 60601-1; 62368-1
1010727CHCO Integrated Power Designs 1010727CHCO 254.9900
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-185 (185W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 7.23" L x 4.36" W x 1.74" H (183.6mm x 110.7mm x 44.2mm) Chassis Mount Enclosed 1010727 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 185W 3 20A, 5A, 3A 36V 84% 5V 12V - -12V 60601-1; 62368-1
1010674CHCO Integrated Power Designs 1010674CHCO 222.9500
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC2-150 (150W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) Chassis Mount Enclosed 1010674 CE, cURus, TUV, UKCA 36V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 150W 3 15A, 4A, 3A 18V 82% 5V 12V - -12V 60601-1; 62368-1
1010748CHCO Integrated Power Designs 1010748CHCO 257.8000
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC2-185 (185W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 7.23" L x 4.36" W x 1.74" H (183.6mm x 110.7mm x 44.2mm) Chassis Mount Enclosed 1010748 CE, cURus, TUV, UKCA 36V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 185W 4 20A, 10A, 2A, 2A 18V 84% 5V 3.3V 15V -15V 60601-1; 62368-1
1011539 Integrated Power Designs 1011539 115.6500
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC1-80 (80W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.50" L x 2.50" W x 1.17" H (114.3mm x 63.5mm x 29.7mm) Chassis Mount Open Frame CE, cURus, TUV, UKCA 18V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 80W 4 6A, 2A, 2A, 2A 9V 82% 5V 24V 12V -12V 60601-1; 62368-1
1010648CH Integrated Power Designs 1010648CH 152.8300
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-110 (110W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 5.25" L x 3.12" W x 1.48" H (133.4mm x 79.2mm x 37.6mm) Chassis Mount Chassis 1010648 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 63W 2 10A, 5A 36V 82% 5V 12V - - 60601-1; 62368-1
1010647 Integrated Power Designs 1010647 146.1600
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-110 (110W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 5.00" L x 3.00" W x 1.32" H (127.0mm x 76.2mm x 33.5mm) Chassis Mount Open Frame CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 63W 2 10A, 6A 36V 82% 3.3V 5V - - 60601-1; 62368-1
1010622CH Integrated Power Designs 1010622CH 143.7100
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC2-110 (110W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 5.25" L x 3.12" W x 1.48" H (133.4mm x 79.2mm x 37.6mm) Chassis Mount Chassis 1010622 CE, cURus, TUV, UKCA 36V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 110W 1 4.6A 18V 82% 24V - - - 60601-1; 62368-1
1011525CH Integrated Power Designs 1011525CH 111.0400
RFQ
ECAD 8605 0.00000000 Integrated Power Designs DC1-80 (80W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.70" L x 2.70" W x 1.48" H (119.4mm x 68.9mm x 37.6mm) Chassis Mount Chassis 1011525 CE, cURus, TUV, UKCA 18V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 80W 1 3.3A 9V 82% 24V - - - 60601-1; 62368-1
1010791CHCO Integrated Power Designs 1010791CHCO 122.1000
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-70 (70W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.79" L x 2.62" W x 1.48" H (121.6mm x 66.5mm x 37.6mm) Chassis Mount Enclosed 1010791 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 70W 1 4.7A 36V 78% 15V - - - 60601-1; 62368-1
1010677 Integrated Power Designs 1010677 212.6400
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC2-150 (150W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 6.00" L x 3.83" W x 1.32" H (152.4mm x 97.3mm x 33.5mm) Chassis Mount Open Frame CE, cURus, TUV, UKCA 36V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 150W 4 15A, 8A, 2A, 2A 18V 82% 5V 3.3V 12V -12V 60601-1; 62368-1
1010796CHCO Integrated Power Designs 1010796CHCO 132.1200
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC2-70 (70W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.79" L x 2.62" W x 1.48" H (121.6mm x 66.5mm x 37.6mm) Chassis Mount Enclosed 1010796 CE, cURus, TUV, UKCA 36V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 70W 4 6A, 5A, 2A, 2A 18V 78% 5V 3.3V 12V -12V 60601-1; 62368-1
1010839 Integrated Power Designs 1010839 212.6400
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-150 (150W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 6.00" L x 3.83" W x 1.32" H (152.4mm x 97.3mm x 33.5mm) Chassis Mount Open Frame CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 134W 4 10A, 9A, 1A, 3A 36V 82% 3.5V 5.2V 12.5V 13.3V 60601-1; 62368-1
1010693CH Integrated Power Designs 1010693CH 204.8800
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-150 (150W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) Chassis Mount Chassis 1010693 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 147W 2 15A, 3A 36V 82% 5V 24V - - 60601-1; 62368-1
1010696 Integrated Power Designs 1010696 209.6100
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-150 (150W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 6.00" L x 3.83" W x 1.32" H (152.4mm x 97.3mm x 33.5mm) Chassis Mount Open Frame CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 150W 3 15A, 4A, 3A 36V 82% 5V 12V - -12V 60601-1; 62368-1
1010658CHCO Integrated Power Designs 1010658CHCO 187.9100
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-110 (110W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 5.25" L x 3.12" W x 1.48" H (133.4mm x 79.2mm x 37.6mm) Chassis Mount Enclosed 1010658 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 110W 4 10A, 6A, 2A, 2A 36V 82% 5V -5V 15V -15V 60601-1; 62368-1
1010783CH Integrated Power Designs 1010783CH 121.3500
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-70 (70W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.79" L x 2.62" W x 1.48" H (121.6mm x 66.5mm x 37.6mm) Chassis Mount Chassis 1010783 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 70W 2 6A, 4A 36V 78% 5V 12V - - 60601-1; 62368-1
1010650CH Integrated Power Designs 1010650CH 152.8300
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-110 (110W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 5.25" L x 3.12" W x 1.48" H (133.4mm x 79.2mm x 37.6mm) Chassis Mount Chassis 1010650 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 110W 2 5A, 4A 36V 82% 12V -12V - - 60601-1; 62368-1
1010776 Integrated Power Designs 1010776 118.7900
RFQ
ECAD 35 0.00000000 Integrated Power Designs DC4-70 (70W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.50" L x 2.50" W x 1.22" H (114.3mm x 63.5mm x 31.0mm) Chassis Mount Open Frame CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 70W 4 6A, 5A, 2A, 2A 36V 78% 5V -5V 12V -12V 60601-1; 62368-1
1011525 Integrated Power Designs 1011525 105.8700
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC1-80 (80W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.50" L x 2.50" W x 1.17" H (114.3mm x 63.5mm x 29.7mm) Chassis Mount Open Frame CE, cURus, TUV, UKCA 18V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 80W 1 3.3A 9V 82% 24V - - - 60601-1; 62368-1
1010741CH Integrated Power Designs 1010741CH 206.0700
RFQ
ECAD 50 0.00000000 Integrated Power Designs DC4-185 (185W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 7.23" L x 4.36" W x 1.74" H (183.6mm x 110.7mm x 44.2mm) Chassis Mount Chassis 1010741 CE, cURus, TUV, UKCA 72V download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 185W 1 3.8A 36V 84% 48V - - - 60601-1; 62368-1
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse