Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Polarization | Applications | Size / Dimension | Base Product Number | Input Type | Approval Agency | Voltage - Input | Cord Length | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | ECCN | HTSUS | Standard Package | Power (Watts) | Voltage - Output | Current - Output (Max) | Region Utilized | Form | No Load Power Consumption | Efficiency | Output Connector | Input Connector | Standard Number |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
DT12PW190A | - | ![]() |
7943 | 0.00000000 | TDK-Lambda Americas Inc | DT12 (12W) | Bulk | Obsolete | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 3.62" L x 2.32" W x 1.30" H (91.9mm x 58.9mm x 33.0mm) | Cord (Sold Separately) | CE | 90 ~ 264 VAC | 59" (1.50m) | - | Not Applicable | EAR99 | 8504.40.7001 | 1 | 12 W | 19V | 650mA | International | Desktop (Class I) | - | 75% | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 10.0mm | IEC 320-C14 | ||||
![]() |
DT12PW240B | - | ![]() |
3856 | 0.00000000 | TDK-Lambda Americas Inc | DT12 (12W) | Bulk | Obsolete | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 3.62" L x 2.32" W x 1.30" H (91.9mm x 58.9mm x 33.0mm) | Cord (Sold Separately) | CE | 90 ~ 264 VAC | 59" (1.50m) | - | Not Applicable | EAR99 | 8504.40.7001 | 1 | 12 W | 24V | 500mA | International | Desktop (Class I) | - | 75% | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 10.0mm | IEC 320-C14 | ||||
![]() |
DT15W120P | - | ![]() |
7756 | 0.00000000 | TDK-Lambda Americas Inc | DT15W (15W) | Bulk | Obsolete | 0°C ~ 50°C | Positive Center | ITE (Commercial) | 4.33" L x 2.56" W x 1.00" H (110.0mm x 65.0mm x 25.4mm) | Cord (Sold Separately) | - | 90 ~ 264 VAC | 39.4" (1.00m) | download | Not Applicable | EAR99 | 8504.40.7001 | 1 | 15 W | 12V | 1.25A | International | Desktop (Class II) | - | 75% | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. | IEC 320-C8 | ||||
![]() |
DT15W180P | - | ![]() |
5482 | 0.00000000 | TDK-Lambda Americas Inc | DT15W (15W) | Bulk | Obsolete | 0°C ~ 50°C | Positive Center | ITE (Commercial) | 4.33" L x 2.56" W x 1.00" H (110.0mm x 65.0mm x 25.4mm) | Cord (Sold Separately) | - | 90 ~ 264 VAC | 39.4" (1.00m) | download | Not Applicable | EAR99 | 8504.40.7001 | 1 | 14 W | 18V | 800mA | International | Desktop (Class II) | - | 75% | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. | IEC 320-C8 | ||||
![]() |
DT30U050P | - | ![]() |
5147 | 0.00000000 | TDK-Lambda Americas Inc | DT30U-P (30W) | Bulk | Obsolete | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.41" L x 2.36" W x 1.42" H (112.0mm x 59.9mm x 36.1mm) | Cord (Sold Separately) | - | 90 ~ 264 VAC | 39.4" (1.00m) | download | Not Applicable | EAR99 | 8504.40.7001 | 1 | 20 W | 5V | 4A | International | Desktop (Class I) | - | 75% | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. | IEC 320-C14 | ||||
![]() |
DT30U150P | - | ![]() |
3637 | 0.00000000 | TDK-Lambda Americas Inc | DT30U-P (30W) | Bulk | Obsolete | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.41" L x 2.36" W x 1.42" H (112.0mm x 59.9mm x 36.1mm) | Cord (Sold Separately) | - | 90 ~ 264 VAC | 39.4" (1.00m) | download | Not Applicable | EAR99 | 8504.40.7001 | 1 | 30 W | 15V | 2A | International | Desktop (Class I) | - | 75% | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. | IEC 320-C14 | ||||
![]() |
DT36PW060P | - | ![]() |
1053 | 0.00000000 | TDK-Lambda Americas Inc | DT36PW (36W) | Bulk | Obsolete | - | Not Applicable | EAR99 | 8504.40.7001 | 1 | |||||||||||||||||||||
![]() |
DT36PW150P | - | ![]() |
5276 | 0.00000000 | TDK-Lambda Americas Inc | DT36PW (36W) | Bulk | Obsolete | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.17" L x 2.36" W x 1.18" H (105.9mm x 59.9mm x 30.0mm) | Cord (Sold Separately) | - | 90 ~ 264 VAC | 39.4" (1.00m) | download | Not Applicable | EAR99 | 8504.40.7001 | 1 | 36 W | 15V | 2.4A | International | Desktop (Class II) | - | 75% | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. | IEC 320-C8 | ||||
![]() |
SDI50-12-U2-P5 | 22.9570 | ![]() |
4738 | 0.00000000 | CUI Inc. | SDI50-U (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 50 W | 12V | 4.2A | Europe | Desktop (Class I) | 150mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | |
![]() |
SDI50-12-U2-P5R | 22.9570 | ![]() |
8918 | 0.00000000 | CUI Inc. | SDI50-U (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 50 W | 12V | 4.2A | Europe | Desktop (Class I) | 150mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | |
![]() |
SDI50-12-U2-P6 | 23.2660 | ![]() |
1480 | 0.00000000 | CUI Inc. | SDI50-U (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 50 W | 12V | 4.2A | Europe | Desktop (Class I) | 150mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | |
![]() |
SDI50-12-U2-P6R | 23.2660 | ![]() |
1989 | 0.00000000 | CUI Inc. | SDI50-U (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 50 W | 12V | 4.2A | Europe | Desktop (Class I) | 150mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | |
![]() |
SDI50-15-UC-P5 | 22.5137 | ![]() |
5157 | 0.00000000 | CUI Inc. | SDI50-U (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 50 W | 15V | 3.34A | North America | Desktop (Class I) | 150mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | |
![]() |
SDI50-15-UC-P5R | 22.5137 | ![]() |
3441 | 0.00000000 | CUI Inc. | SDI50-U (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 50 W | 15V | 3.34A | North America | Desktop (Class I) | 150mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | |
![]() |
SDI50-19-U2-P5R | 22.5271 | ![]() |
1027 | 0.00000000 | CUI Inc. | SDI50-U (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 50 W | 19V | 2.64A | Europe | Desktop (Class I) | 150mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | |
SDI50-19-UD2-P5 | 22.5271 | ![]() |
5041 | 0.00000000 | CUI Inc. | SDI50-UD (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CSA, EN, FCC, IEC, PSE, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 50 W | 19V | 2.64A | Europe | Desktop (Class II) | 150mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
SDI50-19-UD2-P6 | 22.5271 | ![]() |
9967 | 0.00000000 | CUI Inc. | SDI50-UD (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CSA, EN, FCC, IEC, PSE, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 50 W | 19V | 2.64A | Europe | Desktop (Class II) | 150mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
SDI50-24-UD2-P5R | 22.5271 | ![]() |
8740 | 0.00000000 | CUI Inc. | SDI50-UD (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CSA, EN, FCC, IEC, PSE, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 50 W | 24V | 2.1A | Europe | Desktop (Class II) | 150mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
![]() |
SDI50-9-UC-P6R | 24.1257 | ![]() |
6678 | 0.00000000 | CUI Inc. | SDI50-U (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 45 W | 9V | 5A | North America | Desktop (Class I) | 100mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | |
SDI50-9-UD2-P5R | 24.2600 | ![]() |
1349 | 0.00000000 | CUI Inc. | SDI50-UD (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CSA, EN, FCC, IEC, PSE, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 45 W | 9V | 5A | Europe | Desktop (Class II) | 100mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
SDI50-9-UD2-P6 | 24.2600 | ![]() |
2783 | 0.00000000 | CUI Inc. | SDI50-UD (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CSA, EN, FCC, IEC, PSE, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 45 W | 9V | 5A | Europe | Desktop (Class II) | 100mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
SDI50-9-UDC-P6 | 23.1048 | ![]() |
6138 | 0.00000000 | CUI Inc. | SDI50-UD (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CSA, EN, FCC, IEC, PSE, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 45 W | 9V | 5A | North America | Desktop (Class II) | 100mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
![]() |
SDI65-12-U-P11 | 22.0301 | ![]() |
2678 | 0.00000000 | CUI Inc. | SDI65-U (65W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI65 | Cord (Sold Separately) | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9520 | 40 | 60 W | 12V | 5A | International | Desktop (Class I) | 210mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | |
![]() |
SDI65-15-UD2-P6 | 24.9988 | ![]() |
5434 | 0.00000000 | CUI Inc. | SDI65-UD (65W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI65 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9520 | 30 | 65 W | 15V | 4.34A | Europe | Desktop (Class II) | 210mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | |
![]() |
SDI65-18-UD2-P5 | 24.0048 | ![]() |
4920 | 0.00000000 | CUI Inc. | SDI65-UD (65W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI65 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9520 | 30 | 65 W | 18V | 3.62A | Europe | Desktop (Class II) | 210mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | |
![]() |
SDI65-18-UDC-P5 | 22.8630 | ![]() |
8265 | 0.00000000 | CUI Inc. | SDI65-UD (65W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI65 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9520 | 30 | 65 W | 18V | 3.62A | North America | Desktop (Class II) | 210mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | |
![]() |
SDI65-19-UD2-P5 | 24.0048 | ![]() |
5710 | 0.00000000 | CUI Inc. | SDI65-UD (65W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI65 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9520 | 30 | 65 W | 19V | 3.43A | Europe | Desktop (Class II) | 210mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | |
![]() |
SDI65-19-UD2-P6R | 24.0048 | ![]() |
3910 | 0.00000000 | CUI Inc. | SDI65-UD (65W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI65 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9520 | 30 | 65 W | 19V | 3.43A | Europe | Desktop (Class II) | 210mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | |
![]() |
SDI65-24-UD2-P5 | 24.0048 | ![]() |
8182 | 0.00000000 | CUI Inc. | SDI65-UD (65W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI65 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9520 | 30 | 65 W | 24V | 2.71A | Europe | Desktop (Class II) | 210mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | |
![]() |
SDI65-24-UD2-P6 | 24.0048 | ![]() |
2043 | 0.00000000 | CUI Inc. | SDI65-UD (65W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI65 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9520 | 30 | 65 W | 24V | 2.71A | Europe | Desktop (Class II) | 210mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse