Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Polarization | Applications | Size / Dimension | Base Product Number | Input Type | Approval Agency | Voltage - Input | Cord Length | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | ECCN | HTSUS | Standard Package | Power (Watts) | Voltage - Output | Current - Output (Max) | Region Utilized | Form | No Load Power Consumption | Efficiency | Output Connector | Input Connector | Standard Number |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SDI30-12-UC-P5 | 20.2301 | ![]() |
9788 | 0.00000000 | CUI Inc. | SDI30-U (30W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | SDI30 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, RCM, SIQ, TUV, UL | 90 ~ 264 VAC | 60.2" (1.53m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 30 W | 12V | 2.5A | North America | Desktop (Class I) | 75mW (Max) | Level VI | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 61204-3 | |||
SDI30-12-U2-P6R | 18.6047 | ![]() |
4355 | 0.00000000 | CUI Inc. | SDI30-U (30W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | SDI30 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, RCM, SIQ, TUV, UL | 90 ~ 264 VAC | 60.2" (1.53m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 60 | 30 W | 12V | 2.5A | Europe | Desktop (Class I) | 75mW (Max) | Level VI | Barrel Plug R/A, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 61204-3 | |||
SDI30-15-UC-P6 | 20.2301 | ![]() |
3008 | 0.00000000 | CUI Inc. | SDI30-U (30W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | SDI30 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, RCM, SIQ, TUV, UL | 90 ~ 264 VAC | 60.2" (1.53m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 60 | 30 W | 15V | 2A | North America | Desktop (Class I) | 75mW (Max) | Level VI | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 61204-3 | |||
SDI30-15-U2-P6R | 20.5256 | ![]() |
7718 | 0.00000000 | CUI Inc. | SDI30-U (30W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | SDI30 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, RCM, SIQ, TUV, UL | 90 ~ 264 VAC | 60.2" (1.53m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 60 | 30 W | 15V | 2A | Europe | Desktop (Class I) | 75mW (Max) | Level VI | Barrel Plug R/A, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 61204-3 | |||
SDI30-19-U-P6R | 17.3957 | ![]() |
1906 | 0.00000000 | CUI Inc. | SDI30-U (30W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | SDI30 | Cord (Sold Separately) | CB Scheme, CCC, CSA, EN, FCC, IEC, RCM, SIQ, TUV, UL | 90 ~ 264 VAC | 60.2" (1.53m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 54 | 30 W | 19V | 1.6A | International | Desktop (Class I) | 75mW (Max) | Level VI | Barrel Plug R/A, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 61204-3 | |||
SDI30-24-U2-P5R | 21.9630 | ![]() |
2248 | 0.00000000 | CUI Inc. | SDI30-U (30W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | SDI30 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, RCM, SIQ, TUV, UL | 90 ~ 264 VAC | 60.2" (1.53m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 60 | 30 W | 24V | 1.25A | Europe | Desktop (Class I) | 75mW (Max) | Level VI | Barrel Plug R/A, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 61204-3 | |||
SDI30-12-UD2-P5R | 21.6406 | ![]() |
8253 | 0.00000000 | CUI Inc. | SDI30-UD (30W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | SDI30 | Cord | CB Scheme, CSA, EN, FCC, IEC, SIQ, TUV, UL | 90 ~ 264 VAC | 60.2" (1.53m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 60 | 30 W | 12V | 2.5A | Europe | Desktop (Class II) | 75mW (Max) | Level VI | Barrel Plug R/A, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 61204-3 | |||
SDI30-19-UDC-P5R | 21.3316 | ![]() |
2212 | 0.00000000 | CUI Inc. | SDI30-UD (30W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | SDI30 | Cord | CB Scheme, CSA, EN, FCC, IEC, SIQ, TUV, UL | 90 ~ 264 VAC | 60.2" (1.53m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 60 | 30 W | 19V | 1.6A | North America | Desktop (Class II) | 75mW (Max) | Level VI | Barrel Plug R/A, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 61204-3 | |||
SDI30-19-UDC-P6 | 21.3316 | ![]() |
4814 | 0.00000000 | CUI Inc. | SDI30-UD (30W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | SDI30 | Cord | CB Scheme, CSA, EN, FCC, IEC, SIQ, TUV, UL | 90 ~ 264 VAC | 60.2" (1.53m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 60 | 30 W | 19V | 1.6A | North America | Desktop (Class II) | 75mW (Max) | Level VI | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 61204-3 | |||
SDI30-24-UDC-P5 | 21.3316 | ![]() |
5306 | 0.00000000 | CUI Inc. | SDI30-UD (30W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | SDI30 | Cord | CB Scheme, CSA, EN, FCC, IEC, SIQ, TUV, UL | 90 ~ 264 VAC | 60.2" (1.53m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 60 | 30 W | 24V | 1.25A | North America | Desktop (Class II) | 75mW (Max) | Level VI | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 61204-3 | |||
SDI40-15-U-P6R | 14.0912 | ![]() |
8305 | 0.00000000 | CUI Inc. | SDI40-U (40W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | SDI40 | Cord (Sold Separately) | CB Scheme, CCC, CSA, EN, FCC, IEC, RCM, SIQ, TUV, UL | 90 ~ 264 VAC | 60.2" (1.53m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 40 | 41 W | 15V | 2.7A | International | Desktop (Class I) | 75mW (Max) | Level VI | Barrel Plug R/A, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 61204-3 | |||
SDI40-19-UD-P5 | 14.2255 | ![]() |
4017 | 0.00000000 | CUI Inc. | SDI40-UD (40W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | SDI40 | Cord (Sold Separately) | CE, cULus, GS, PSE | 90 ~ 264 VAC | 60.2" (1.53m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 40 | 40 W | 19V | 2.1A | International | Desktop (Class II) | 75mW (Max) | Level VI | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | ||||
SDI40-15-UC-P5 | 18.7793 | ![]() |
7211 | 0.00000000 | CUI Inc. | SDI40-U (40W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | SDI40 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, RCM, SIQ, TUV, UL | 90 ~ 264 VAC | 60.2" (1.53m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 60 | 41 W | 15V | 2.7A | North America | Desktop (Class I) | 75mW (Max) | Level VI | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 61204-3 | |||
SDI40-15-UDC-P6R | 18.7793 | ![]() |
1101 | 0.00000000 | CUI Inc. | SDI40-UD (40W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | SDI40 | Cord | CE, cULus, GS, PSE | 90 ~ 264 VAC | 60.2" (1.53m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 60 | 41 W | 15V | 2.7A | North America | Desktop (Class II) | 75mW (Max) | Level VI | Barrel Plug R/A, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | ||||
SDI40-19-UDC-P5 | 18.7793 | ![]() |
5353 | 0.00000000 | CUI Inc. | SDI40-UD (40W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | SDI40 | Cord | CE, cULus, GS, PSE | 90 ~ 264 VAC | 60.2" (1.53m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 60 | 40 W | 19V | 2.1A | North America | Desktop (Class II) | 75mW (Max) | Level VI | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | ||||
SDI40-19-UDC-P5R | 17.1539 | ![]() |
4923 | 0.00000000 | CUI Inc. | SDI40-UD (40W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | SDI40 | Cord | CE, cULus, GS, PSE | 90 ~ 264 VAC | 60.2" (1.53m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 60 | 40 W | 19V | 2.1A | North America | Desktop (Class II) | 75mW (Max) | Level VI | Barrel Plug R/A, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | ||||
SDI40-24-UDC-P6 | 16.8584 | ![]() |
1742 | 0.00000000 | CUI Inc. | SDI40-UD (40W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | SDI40 | Cord | CE, cULus, GS, PSE | 90 ~ 264 VAC | 60.2" (1.53m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 60 | 41 W | 24V | 1.7A | North America | Desktop (Class II) | 75mW (Max) | Level VI | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | ||||
SDI40-24-UDC-P6R | 16.8584 | ![]() |
1979 | 0.00000000 | CUI Inc. | SDI40-UD (40W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | SDI40 | Cord | CE, cULus, GS, PSE | 90 ~ 264 VAC | 60.2" (1.53m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 60 | 41 W | 24V | 1.7A | North America | Desktop (Class II) | 75mW (Max) | Level VI | Barrel Plug R/A, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | ||||
SDI40-15-UD2-P5R | 23.5077 | ![]() |
4357 | 0.00000000 | CUI Inc. | SDI40-UD (40W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | SDI40 | Cord | CE, cULus, GS, PSE | 90 ~ 264 VAC | 60.2" (1.53m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 60 | 41 W | 15V | 2.7A | Europe | Desktop (Class II) | 75mW (Max) | Level VI | Barrel Plug R/A, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | ||||
SDI40-12-UD2-P6 | 23.5077 | ![]() |
1648 | 0.00000000 | CUI Inc. | SDI40-UD (40W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | SDI40 | Cord | CE, cULus, GS, PSE | 90 ~ 264 VAC | 60.2" (1.53m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 60 | 36 W | 12V | 3A | Europe | Desktop (Class II) | 75mW (Max) | Level VI | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | ||||
![]() |
SWI25-15-E-P5 | 17.9900 | ![]() |
68 | 0.00000000 | CUI Inc. | SWI25-E (25.2W) | Box | Active | -20°C ~ 40°C | Positive Center | ITE (Commercial) | 2.80" L x 1.30" W x 1.91" H (71.0mm x 33.0mm x 48.4mm) | SWI25 | Fixed Blade | EN, FCC, SIQ, TUV | 90 ~ 264 VAC | 70.9" (1.80m) | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 50 | 25 W | 15V | 1.67A | Europe | Wall Mount (Class II) | 75mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | CEE 7/16 | 55011 Class B; 60950-1; 61000-3-2; 61000-3-3; 61000-6-1; 62368-1 | |
![]() |
SWI3-5-N-P6 | 4.6814 | ![]() |
5254 | 0.00000000 | CUI Inc. | SWI3-N (3W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 2.13" L x 1.16" W x 1.49" H (54.0mm x 29.5mm x 37.9mm) | SWI3-5 | Fixed Blade | CSA, FCC, PSE, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 120 | 3 W | 5V | 600mA | North America | Wall Mount (Class II) | 75mW (Max) | Level VI | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | NEMA 1-15P | C22.2 No. 60950-1; 60950-1; 62368-1 | ||
![]() |
SWI3-5-E-P5R | 4.6814 | ![]() |
8832 | 0.00000000 | CUI Inc. | SWI3-E (3W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 2.13" L x 1.16" W x 2.20" H (54.0mm x 29.5mm x 56.0mm) | SWI3-5 | Fixed Blade | CB Scheme, IEC | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 120 | 3 W | 5V | 600mA | Europe | Wall Mount (Class II) | 75mW (Max) | Level VI, CoC Tier 2 | Barrel Plug R/A, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | CEE 7/16 | 60950-1; 62368-1 | ||
![]() |
SWM6-6-EV-P5R | 8.6509 | ![]() |
8588 | 0.00000000 | CUI Inc. | SWM6-E (6W) | Box | Active | 0°C ~ 40°C | Positive Center | Medical | 2.11" L x 1.62" W x 1.11" H (53.5mm x 41.2mm x 28.2mm) | SWM6-6 | Fixed Blade | CB Scheme, CSA, EN, FCC, IEC, PSE, TUV, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 140 | 6 W | 6V | 1A | Europe | Wall Mount (Class II) | 75mW (Max) | Level VI, CoC Tier 2 | Barrel Plug R/A, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | CEE 7/16 | C22.2 No. 60601-1; 55011 Class B; 55024; 55032 Class B; 60601-1; 60950-1; 61000-3-2; 61000-3-3 | ||
![]() |
SWM6-9-EV-P5 | 8.6509 | ![]() |
5296 | 0.00000000 | CUI Inc. | SWM6-E (6W) | Box | Active | 0°C ~ 40°C | Positive Center | Medical | 2.11" L x 1.62" W x 1.11" H (53.5mm x 41.2mm x 28.2mm) | SWM6-9 | Fixed Blade | CB Scheme, CSA, EN, FCC, IEC, PSE, TUV, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 140 | 6 W | 9V | 660mA | Europe | Wall Mount (Class II) | 75mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | CEE 7/16 | C22.2 No. 60601-1; 55011 Class B; 55024; 55032 Class B; 60601-1; 60950-1; 61000-3-2; 61000-3-3 | ||
![]() |
SWM6-5-EH-P5R | 8.6509 | ![]() |
3343 | 0.00000000 | CUI Inc. | SWM6-E (6W) | Box | Active | 0°C ~ 40°C | Positive Center | Medical | 2.17" L x 0.98" W x 1.44" H (55.0mm x 25.0mm x 36.7mm) | SWM6-5 | Fixed Blade | CB Scheme, CSA, EN, FCC, IEC, PSE, TUV, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 140 | 6 W | 5V | 1.2A | Europe | Wall Mount (Class II) | 75mW (Max) | Level VI, CoC Tier 2 | Barrel Plug R/A, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | CEE 7/16 | C22.2 No. 60601-1; 55011 Class B; 55024; 55032 Class B; 60601-1; 60950-1; 61000-3-2; 61000-3-3 | ||
![]() |
SWM6-9-EH-P6R | 8.6509 | ![]() |
3039 | 0.00000000 | CUI Inc. | SWM6-E (6W) | Box | Active | 0°C ~ 40°C | Positive Center | Medical | 2.17" L x 0.98" W x 1.44" H (55.0mm x 25.0mm x 36.7mm) | SWM6-9 | Fixed Blade | CB Scheme, CSA, EN, FCC, IEC, PSE, TUV, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 140 | 6 W | 9V | 660mA | Europe | Wall Mount (Class II) | 75mW (Max) | Level VI, CoC Tier 2 | Barrel Plug R/A, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | CEE 7/16 | C22.2 No. 60601-1; 55011 Class B; 55024; 55032 Class B; 60601-1; 60950-1; 61000-3-2; 61000-3-3 | ||
![]() |
SWM6-12-EH-P5R | 8.6509 | ![]() |
8116 | 0.00000000 | CUI Inc. | SWM6-E (6W) | Box | Active | 0°C ~ 40°C | Positive Center | Medical | 2.17" L x 0.98" W x 1.44" H (55.0mm x 25.0mm x 36.7mm) | SWM6-12 | Fixed Blade | CB Scheme, CSA, EN, FCC, IEC, PSE, TUV, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 140 | 6 W | 12V | 500mA | Europe | Wall Mount (Class II) | 75mW (Max) | Level VI, CoC Tier 2 | Barrel Plug R/A, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | CEE 7/16 | C22.2 No. 60601-1; 55011 Class B; 55024; 55032 Class B; 60601-1; 60950-1; 61000-3-2; 61000-3-3 | ||
![]() |
SWM6-5-NV-P6R | 8.6509 | ![]() |
1293 | 0.00000000 | CUI Inc. | SWM6-N (6W) | Box | Active | 0°C ~ 40°C | Positive Center | Medical | 2.11" L x 1.62" W x 1.11" H (53.5mm x 41.2mm x 28.2mm) | SWM6-5 | Fixed Blade | CB Scheme, CSA, EN, FCC, IEC, PSE, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 140 | 6 W | 5V | 1.2A | North America | Wall Mount (Class II) | 100mW (Max) | Level VI | Barrel Plug R/A, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | NEMA 1-15P | C22.2 No. 60601-1; 55011 Class B; 55024; 55032 Class B; 60601-1; 60950-1; 61000-3-2; 61000-3-3 | ||
![]() |
SWM6-6-NV-P6 | 8.6509 | ![]() |
2587 | 0.00000000 | CUI Inc. | SWM6-N (6W) | Box | Active | 0°C ~ 40°C | Positive Center | Medical | 2.11" L x 1.62" W x 1.11" H (53.5mm x 41.2mm x 28.2mm) | SWM6-6 | Fixed Blade | CB Scheme, CSA, EN, FCC, IEC, PSE, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 140 | 6 W | 6V | 1A | North America | Wall Mount (Class II) | 100mW (Max) | Level VI | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | NEMA 1-15P | C22.2 No. 60601-1; 55011 Class B; 55024; 55032 Class B; 60601-1; 60950-1; 61000-3-2; 61000-3-3 |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse