Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Polarization | Applications | Size / Dimension | Base Product Number | Input Type | Approval Agency | Voltage - Input | Cord Length | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Voltage - Output | Current - Output (Max) | Region Utilized | Form | No Load Power Consumption | Efficiency | Output Connector | Input Connector | Standard Number |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
SWM30-12-NV-P6R | 16.9524 | ![]() |
8896 | 0.00000000 | CUI Inc. | SWM30-N (30W) | Box | Active | 0°C ~ 40°C | Positive Center | Medical | 2.99" L x 1.69" W x 1.16" H (75.9mm x 42.9mm x 29.5mm) | SWM30 | Fixed Blade | CB Scheme, CSA, EN, FCC, IEC, PSE, UL | 90 ~ 264 VAC | 47.2" (1.20m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 80 | 36 W | 12V | 3A | North America | Wall Mount (Class II) | 100mW (Max) | Level VI | Barrel Plug R/A, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | NEMA 1-15P | C22.2 No. 60601-1; 55024; 55032 Class B; 60601-1; 60950-1; 61000-3-2; 61000-3-3 | ||
![]() |
SWM30-36-NV-P6 | 16.9524 | ![]() |
5727 | 0.00000000 | CUI Inc. | SWM30-N (30W) | Box | Active | 0°C ~ 40°C | Positive Center | Medical | 2.99" L x 1.69" W x 1.16" H (75.9mm x 42.9mm x 29.5mm) | SWM30 | Fixed Blade | CB Scheme, CSA, EN, FCC, IEC, PSE, UL | 90 ~ 264 VAC | 47.2" (1.20m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 80 | 30 W | 36V | 830mA | North America | Wall Mount (Class II) | 100mW (Max) | Level VI | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | NEMA 1-15P | C22.2 No. 60601-1; 55024; 55032 Class B; 60601-1; 60950-1; 61000-3-2; 61000-3-3 | ||
![]() |
SWM30-15-EV-P6 | 16.9524 | ![]() |
6985 | 0.00000000 | CUI Inc. | SWM30-E (30W) | Box | Active | 0°C ~ 40°C | Positive Center | Medical | 2.99" L x 1.69" W x 1.16" H (75.9mm x 42.9mm x 29.5mm) | SWM30 | Fixed Blade | CB Scheme, CSA, EN, FCC, IEC, UL | 90 ~ 264 VAC | 47.2" (1.20m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 80 | 30 W | 15V | 2A | Europe | Wall Mount (Class II) | 75mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | CEE 7/16 | C22.2 No. 60601-1; 55024; 55032 Class B; 60601-1; 60950-1; 61000-3-2; 61000-3-3 | ||
![]() |
SWM30-48-EV-P6R | 16.9524 | ![]() |
7160 | 0.00000000 | CUI Inc. | SWM30-E (30W) | Box | Active | 0°C ~ 40°C | Positive Center | Medical | 2.99" L x 1.69" W x 1.16" H (75.9mm x 42.9mm x 29.5mm) | SWM30 | Fixed Blade | CB Scheme, CSA, EN, FCC, IEC, UL | 90 ~ 264 VAC | 47.2" (1.20m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 80 | 30 W | 48V | 620mA | Europe | Wall Mount (Class II) | 75mW (Max) | Level VI, CoC Tier 2 | Barrel Plug R/A, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | CEE 7/16 | C22.2 No. 60601-1; 55024; 55032 Class B; 60601-1; 60950-1; 61000-3-2; 61000-3-3 | ||
![]() |
SDI50-12-U2-P5 | 22.9570 | ![]() |
4738 | 0.00000000 | CUI Inc. | SDI50-U (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 50 W | 12V | 4.2A | Europe | Desktop (Class I) | 150mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
![]() |
SDI50-12-U2-P5R | 22.9570 | ![]() |
8918 | 0.00000000 | CUI Inc. | SDI50-U (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 50 W | 12V | 4.2A | Europe | Desktop (Class I) | 150mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
![]() |
SDI50-12-U2-P6 | 23.2660 | ![]() |
1480 | 0.00000000 | CUI Inc. | SDI50-U (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 50 W | 12V | 4.2A | Europe | Desktop (Class I) | 150mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
![]() |
SDI50-12-U2-P6R | 23.2660 | ![]() |
1989 | 0.00000000 | CUI Inc. | SDI50-U (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 50 W | 12V | 4.2A | Europe | Desktop (Class I) | 150mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
![]() |
SDI50-15-UC-P5 | 22.5137 | ![]() |
5157 | 0.00000000 | CUI Inc. | SDI50-U (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 50 W | 15V | 3.34A | North America | Desktop (Class I) | 150mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
![]() |
SDI50-15-UC-P5R | 22.5137 | ![]() |
3441 | 0.00000000 | CUI Inc. | SDI50-U (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 50 W | 15V | 3.34A | North America | Desktop (Class I) | 150mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
SDI50-19-UD2-P5 | 22.5271 | ![]() |
5041 | 0.00000000 | CUI Inc. | SDI50-UD (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CSA, EN, FCC, IEC, PSE, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 50 W | 19V | 2.64A | Europe | Desktop (Class II) | 150mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | |||
SDI50-19-UD2-P6 | 22.5271 | ![]() |
9967 | 0.00000000 | CUI Inc. | SDI50-UD (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CSA, EN, FCC, IEC, PSE, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 50 W | 19V | 2.64A | Europe | Desktop (Class II) | 150mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | |||
SDI50-24-UD2-P5R | 22.5271 | ![]() |
8740 | 0.00000000 | CUI Inc. | SDI50-UD (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CSA, EN, FCC, IEC, PSE, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 50 W | 24V | 2.1A | Europe | Desktop (Class II) | 150mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | |||
![]() |
SDI50-9-UC-P6R | 24.1257 | ![]() |
6678 | 0.00000000 | CUI Inc. | SDI50-U (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 45 W | 9V | 5A | North America | Desktop (Class I) | 100mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
SDI50-9-UD2-P5R | 24.2600 | ![]() |
1349 | 0.00000000 | CUI Inc. | SDI50-UD (50W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI50 | Cord | CB Scheme, CSA, EN, FCC, IEC, PSE, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 30 | 45 W | 9V | 5A | Europe | Desktop (Class II) | 100mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | |||
![]() |
SDI65-12-U-P11 | 22.0301 | ![]() |
2678 | 0.00000000 | CUI Inc. | SDI65-U (65W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI65 | Cord (Sold Separately) | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9520 | 40 | 60 W | 12V | 5A | International | Desktop (Class I) | 210mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
![]() |
SDI65-15-UD2-P6 | 24.9988 | ![]() |
5434 | 0.00000000 | CUI Inc. | SDI65-UD (65W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI65 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9520 | 30 | 65 W | 15V | 4.34A | Europe | Desktop (Class II) | 210mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
![]() |
SDI65-19-UD2-P5 | 24.0048 | ![]() |
5710 | 0.00000000 | CUI Inc. | SDI65-UD (65W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI65 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9520 | 30 | 65 W | 19V | 3.43A | Europe | Desktop (Class II) | 210mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
![]() |
SDI65-24-UD2-P5 | 24.0048 | ![]() |
8182 | 0.00000000 | CUI Inc. | SDI65-UD (65W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI65 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9520 | 30 | 65 W | 24V | 2.71A | Europe | Desktop (Class II) | 210mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
![]() |
SDI65-24-UD2-P6 | 24.0048 | ![]() |
2043 | 0.00000000 | CUI Inc. | SDI65-UD (65W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI65 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9520 | 30 | 65 W | 24V | 2.71A | Europe | Desktop (Class II) | 210mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
![]() |
SDI65-48-UD2-P5R | 24.7436 | ![]() |
8774 | 0.00000000 | CUI Inc. | SDI65-UD (65W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI65 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9520 | 30 | 65 W | 48V | 1.36A | Europe | Desktop (Class II) | 210mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
![]() |
SDI65-48-UD2-P6 | 24.7436 | ![]() |
2931 | 0.00000000 | CUI Inc. | SDI65-UD (65W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI65 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9520 | 30 | 65 W | 48V | 1.36A | Europe | Desktop (Class II) | 210mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
![]() |
SDI65-48-UD2-P6R | 24.7436 | ![]() |
5050 | 0.00000000 | CUI Inc. | SDI65-UD (65W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | SDI65 | Cord | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9520 | 30 | 65 W | 48V | 1.36A | Europe | Desktop (Class II) | 210mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C8 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
![]() |
SDI90-19-U-P6R | - | ![]() |
1714 | 0.00000000 | CUI Inc. | SDI90-U (90W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 5.94" L x 2.52" W x 1.42" H (151.0mm x 64.0mm x 36.0mm) | SDI90 | Cord (Sold Separately) | CB Scheme, CSA, EN, FCC, IEC, PSE, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 24 | 90 W | 19V | 4.74A | International | Desktop (Class I) | 210mW (Max) | Level VI | Barrel Plug R/A, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
![]() |
SDI90-24-U-ST | - | ![]() |
2800 | 0.00000000 | CUI Inc. | SDI90-U (90W) | Box | Active | 0°C ~ 40°C | - | ITE (Commercial) | 5.94" L x 2.52" W x 1.42" H (151.0mm x 64.0mm x 36.0mm) | SDI90 | Cord (Sold Separately) | CB Scheme, CSA, EN, FCC, IEC, PSE, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 24 | 90 W | 24V | 3.75A | International | Desktop (Class I) | 210mW (Max) | Level VI | Stripped, Tinned Wire Leads | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
![]() |
SDI90-24-UC-P6R | - | ![]() |
6757 | 0.00000000 | CUI Inc. | SDI90-U (90W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 5.94" L x 2.52" W x 1.42" H (151.0mm x 64.0mm x 36.0mm) | SDI90 | Cord | CB Scheme, CSA, EN, FCC, IEC, PSE, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 24 | 90 W | 24V | 3.75A | North America | Desktop (Class I) | 210mW (Max) | Level VI | Barrel Plug R/A, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
![]() |
SDI90-48-UC-P6R | - | ![]() |
8601 | 0.00000000 | CUI Inc. | SDI90-U (90W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 5.94" L x 2.52" W x 1.42" H (151.0mm x 64.0mm x 36.0mm) | SDI90 | Cord | CB Scheme, CSA, EN, FCC, IEC, PSE, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 24 | 90 W | 48V | 1.88A | North America | Desktop (Class I) | 210mW (Max) | Level VI | Barrel Plug R/A, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | IEC 320-C14 | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
![]() |
SMI18-5-N-P7 | 12.6405 | ![]() |
2607 | 0.00000000 | CUI Inc. | SMI18 (18W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 2.95" L x 1.41" W x 2.58" H (75.0mm x 35.8mm x 65.6mm) | SMI18 | Multi-Blade (Included) | CB Scheme, CCC, CSA, EN, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 100 | 15 W | 5V | 3A | North America | Wall Mount (Class II) | 100mW (Max) | Level VI, CoC Tier 2 | Barrel Plug, 1.35mm I.D. x 3.5mm O.D. x 9.5mm | Multi-Blade (Included) | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
![]() |
SMI18-9-K-ST | 11.9016 | ![]() |
6309 | 0.00000000 | CUI Inc. | SMI18 (18W) | Box | Active | 0°C ~ 40°C | - | ITE (Commercial) | 2.95" L x 1.41" W x 2.58" H (75.0mm x 35.8mm x 65.6mm) | SMI18 | Multi-Blade (Sold Separately) | CB Scheme, CCC, CSA, EN, IEC, PSE, RCM, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | EAR99 | 8504.40.9510 | 100 | 20 W | 9V | 2.2A | International | Wall Mount (Class II) | 100mW (Max) | Level VI, CoC Tier 2 | Stripped, Tinned Wire Leads | Multi-Blade (Sold Separately) | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | ||
![]() |
SWI6-7.5-N-P7 | 8.1164 | ![]() |
2563 | 0.00000000 | CUI Inc. | SWI6-N (6W) | Box | Active | 0°C ~ 40°C | Positive Center | ITE (Commercial) | 2.20" L x 1.10" W x 1.65" H (56.0mm x 28.0mm x 42.0mm) | SWI6-7.5 | Fixed Blade | CB Scheme, CSA, FCC, IEC, PSE, UL | 90 ~ 264 VAC | 59" (1.50m) | download | RoHS Compliant | Not Applicable | 2266-SWI6-7.5-N-P7 | EAR99 | 8504.40.9510 | 100 | 7.5 W | 7.5V | 1A | North America | Wall Mount (Class II) | 100mW (Max) | Level VI | Barrel Plug, 1.35mm I.D. x 3.5mm O.D. x 9.5mm | NEMA 1-15P | C22.2 No. 60950-1; 60950-1; 62368-1 |