Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
NMP1K2-H#HC#K-00 MEAN WELL USA Inc. NMP1K2-H#HC#K-00 610.9800
RFQ
ECAD 5462 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 900W 4 88.5% 24V 24V 5V 48V - - 4 kV 60601-1; 62368-1 10 A 10 A 36 A 5 A
CX10S-CDDDDG-P-A-DK00000 Advanced Energy CX10S-CDDDDG-P-A-DK00000 -
RFQ
ECAD 8059 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CDDDDG-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 24V 48V 48V 48V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 4.17 A 4.17 A 4.17 A 4.17 A 3 A
CX10S-0A0CHC-P-A-DK00000 Advanced Energy CX10S-0A0CHC-P-A-DK00000 -
RFQ
ECAD 4996 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0A0CHC-P-A-DK00000 EAR99 8504.40.9540 1 605W 5 93% 5V 24V 5V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 6 A 3 A 8.3 A
CX10S-000BC0-P-A-DK00000 Advanced Energy CX10S-000BC0-P-A-DK00000 -
RFQ
ECAD 6350 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-000BC0-P-A-DK00000 EAR99 8504.40.9540 1 380W 2 93% 12V 24V - - - - No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A
PBA100F-5-V Cosel USA, Inc. PBA100F-5-V 117.1800
RFQ
ECAD 7192 0.00000000 Cosel USA, Inc. PBA (100W) Box Active -10°C ~ 71°C (With Derating) ITE (Commercial) 5.79" L x 1.26" W x 3.66" H (147.1mm x 32.0mm x 93.0mm) Chassis Mount Open Frame PBA100 CE, cURus, TUV 85 ~ 264 VAC download ROHS3 Compliant Not Applicable EAR99 8504.40.9520 1 1 84% 5V - - - - No 3 kV 20 A
CX10S-HAGDB0-P-A-DK00000 Advanced Energy CX10S-HAGDB0-P-A-DK00000 -
RFQ
ECAD 9511 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HAGDB0-P-A-DK00000 EAR99 8504.40.9540 1 705W 7 93% 5V 24V 5V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 3 A 3 A 4.17 A
CX10S-DHCGBC-P-A-DK00000 Advanced Energy CX10S-DHCGBC-P-A-DK00000 -
RFQ
ECAD 4844 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DHCGBC-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 48V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 8.3 A 3 A 3 A
CX10S-GGBH0A-P-A-DK00000 Advanced Energy CX10S-GGBH0A-P-A-DK00000 -
RFQ
ECAD 8582 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GGBH0A-P-A-DK00000 EAR99 8504.40.9540 1 625W 8 93% 24V 24V 24V 24V 12V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 15 A 6 A
VCCM600M-0C0A-DK000 Vox Power Ltd. VCCM600M-0C0A-DK000 405.2567
RFQ
ECAD 2659 0.00000000 Vox Power Ltd. VCCM600M Box Active -40°C ~ 70°C Medical 7.00" L x 4.00" W x 1.57" H (177.8mm x 101.6mm x 40.0mm) Chassis Mount Open Frame Adjustable Output, Load Sharing, PFC, Remote Sense, Universal Input VCCM600 CB, CE, CSA, UL 85 ~ 264 VAC, 120 ~ 370 VDC download Not Applicable REACH Unaffected 2050-VCCM600M-0C0A-DK000 EAR99 8504.40.9540 1 275W 2 90% 24V 5V - - - - No 4 kV 60601-1 7.5 A 25 A
CX10S-DGDHHD-P-A-DK00000 Advanced Energy CX10S-DGDHHD-P-A-DK00000 -
RFQ
ECAD 8979 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DGDHHD-P-A-DK00000 EAR99 8504.40.9540 1 920W 9 93% 48V 24V 24V 48V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 4.17 A 6 A 3 A
NEVO+600S-4541-DK000 Vox Power Ltd. NEVO+600S-4541-DK000 460.3067
RFQ
ECAD 7303 0.00000000 Vox Power Ltd. NEVO+600S Box Active -20°C ~ 70°C ITE (Commercial) 3.06" L x 3.06" W x 1.61" H (77.7mm x 77.7mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote Sense, Universal Input NEVO+600 CB, CE, CSA, IEC, UL 85 ~ 264 VAC, 120 ~ 370 VDC download Not Applicable REACH Unaffected 2050-NEVO+600S-4541-DK000 EAR99 8504.40.9540 1 425W 4 86% 48V 12V 12V 48V 5V - No 4 kV 60950-1; 62368-1 3.75 A 5 A 5 A 3.75 A 25 A
CX10S-AACDBH-P-A-DK00000 Advanced Energy CX10S-AACDBH-P-A-DK00000 -
RFQ
ECAD 8654 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AACDBH-P-A-DK00000 EAR99 8504.40.9540 1 890W 7 93% 5V 5V 24V 48V 12V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 8.3 A 4.17 A 15 A 6 A
CX10S-DA0CGC-P-A-DK00000 Advanced Energy CX10S-DA0CGC-P-A-DK00000 -
RFQ
ECAD 8185 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DA0CGC-P-A-DK00000 EAR99 8504.40.9540 1 825W 6 93% 48V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 8.3 A 3 A 3 A 8.3 A
HDM240E-112 Digital Power Corporation HDM240E-112 137.4900
RFQ
ECAD 9030 0.00000000 Digital Power Corporation HDM240 (240W) Bulk Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.10" L x 2.44" W x 1.99" H (104.1mm x 62.0mm x 50.5mm) Chassis Mount Enclosed Adjustable Output, DC Input Capable, PFC, Standby Output, Universal Input CB, CE, cURus 90 ~ 264 VAC download RoHS Compliant Vendor Undefined 2647-HDM240E-112 EAR99 8504.40.6018 1 240W 1 92% 12V - - - - - No 4 kV 60601-1; 60950-1 20 A
NMP650-##H#-00 MEAN WELL USA Inc. NMP650-##H#-00 308.0300
RFQ
ECAD 1124 0.00000000 MEAN WELL USA Inc. NMP (650W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 3.50" W x 1.61" H (250.0mm x 89.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP650 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 240W 1 88.5% 24V - - - - - 4 kV 60601-1; 62368-1 10 A
CX10S-BACCD0-P-A-DK00000 Advanced Energy CX10S-BACCD0-P-A-DK00000 -
RFQ
ECAD 1246 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BACCD0-P-A-DK00000 EAR99 8504.40.9540 1 885W 5 93% 12V 5V 24V 24V 48V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 21 A 8.3 A 8.3 A 4.17 A
CX10S-HDHCG0-P-A-DK00000 Advanced Energy CX10S-HDHCG0-P-A-DK00000 -
RFQ
ECAD 7464 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HDHCG0-P-A-DK00000 EAR99 8504.40.9540 1 720W 8 93% 5V 24V 48V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 4.17 A 6 A 3 A 8.3 A
AMES100-48SNZ aimtec AMES100-48SNZ 27.3200
RFQ
ECAD 2 0.00000000 aimtec AMES100-NZ Box Active -30°C ~ 70°C (With Derating) Household Appliances, ITE (Commercial) 5.08" L x 3.82" W x 1.18" H (129.0mm x 97.0mm x 30.0mm) Chassis Mount Enclosed Adjustable Output, DC Input Capable, Universal Input cURus 85 ~ 264 VAC, 120 ~ 373 VDC download ROHS3 Compliant Not Applicable REACH info available upon request 2721-AMES100-48SNZ 8504.40.9530 5 110W 1 91% 48V - - - - - - 4 kV 60335-1; 62368-1 2.3 A
CX10S-HGD0DB-P-A-DK00000 Advanced Energy CX10S-HGD0DB-P-A-DK00000 -
RFQ
ECAD 7604 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HGD0DB-P-A-DK00000 EAR99 8504.40.9540 1 800W 7 93% 5V 24V 24V 24V 48V 48V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 3 A 3 A 4.17 A 4.17 A
CX10S-DGGAGB-P-A-DK00000 Advanced Energy CX10S-DGGAGB-P-A-DK00000 -
RFQ
ECAD 2417 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DGGAGB-P-A-DK00000 EAR99 8504.40.9540 1 845W 9 93% 48V 24V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 3 A 3 A 21 A
IMP4-1Q0-1W0-1W0-1Y0-0M Artesyn Embedded Power IMP4-1Q0-1W0-1W0-1Y0-0M -
RFQ
ECAD 1091 0.00000000 Artesyn Embedded Power iMP® (1158W) Bulk Active -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 10.00" L x 5.00" W x 2.50" H (254.0mm x 127.0mm x 63.5mm) Chassis Mount Enclosed Adjustable Output, I²C Interface, PFC, PMBus™, Remote Sense, Universal Input IMP4-1Q0 CB, CE, CSA, UL 85 ~ 264 VAC, 120 ~ 300 VDC - RoHS Compliant Not Applicable EAR99 8504.40.9540 1 798W 4 85% 24V 48V 48V 60V - - No 2 kV 8.5 A 4 A 4 A 3.5 A
CX10S-A0DAGD-P-A-DK00000 Advanced Energy CX10S-A0DAGD-P-A-DK00000 -
RFQ
ECAD 2098 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-A0DAGD-P-A-DK00000 EAR99 8504.40.9540 1 730W 6 93% 5V 48V 5V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 21 A 3 A 3 A 4.17 A
NMP1K2-#CE#EC-00 MEAN WELL USA Inc. NMP1K2-#CE#EC-00 641.2200
RFQ
ECAD 9425 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 840W 4 88.5% 5V 12V 12V 5V - - 4 kV 60601-1; 62368-1 36 A 20 A 20 A 36 A
CX10S-HG0CCB-P-A-DK00000 Advanced Energy CX10S-HG0CCB-P-A-DK00000 -
RFQ
ECAD 1268 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HG0CCB-P-A-DK00000 EAR99 8504.40.9540 1 800W 7 93% 5V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 3 A 3 A 8.3 A 8.3 A
CX10S-GG0ACG-P-A-DK00000 Advanced Energy CX10S-GG0ACG-P-A-DK00000 -
RFQ
ECAD 4752 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GG0ACG-P-A-DK00000 EAR99 8504.40.9540 1 665W 8 93% 24V 24V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 21 A 8.3 A
CX10S-0BCAAH-P-A-DK00000 Advanced Energy CX10S-0BCAAH-P-A-DK00000 -
RFQ
ECAD 2372 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0BCAAH-P-A-DK00000 EAR99 8504.40.9540 1 690W 6 93% 12V 24V 5V 5V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 21 A 21 A 6 A 3 A
CX10S-GAHBCG-P-A-DK00000 Advanced Energy CX10S-GAHBCG-P-A-DK00000 -
RFQ
ECAD 1898 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GAHBCG-P-A-DK00000 EAR99 8504.40.9540 1 825W 9 93% 24V 24V 5V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 6 A 3 A 15 A
PS3N-D12A1DN IDEC PS3N-D12A1DN -
RFQ
ECAD 8960 0.00000000 IDEC PS3N (150W) Bulk Obsolete -10°C ~ 60°C (With Derating) ITE (Commercial) 4.67" L x 1.30" W x 3.35" H (118.5mm x 33.0mm x 85.0mm) Chassis Mount Enclosed Adjustable Output FCC, VCCI 85 ~ 132 VAC, 105 ~ 170 VDC - ROHS3 Compliant Not Applicable 1885-PS3N-D12A1DN EAR99 8504.40.9520 1 54W 1 80% 12V - - - - - - 2 kV 60950-1 4.5 A
WX1-7412423-2 Vicor Corporation WX1-7412423-2 -
RFQ
ECAD 4259 0.00000000 Vicor Corporation - Bulk Obsolete - Not Applicable 1102-WX1-7412423-2 OBSOLETE 1
CX10S-GDG0GC-P-A-DK00000 Advanced Energy CX10S-GDG0GC-P-A-DK00000 -
RFQ
ECAD 3450 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GDG0GC-P-A-DK00000 EAR99 8504.40.9540 1 760W 8 93% 24V 24V 48V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 3 A 3 A 3 A