SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-H0DDHC-P-A-DK00000 Advanced Energy CX10S-H0DDHC-P-A-DK00000 -
RFQ
ECAD 2265 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-H0DDHC-P-A-DK00000 EAR99 8504.40.9540 1 800W 7 93% 5V 24V 48V 48V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 4.17 A 4.17 A 6 A 3 A
CX10S-DDGGGC-P-A-DK00000 Advanced Energy CX10S-DDGGGC-P-A-DK00000 -
RFQ
ECAD 1247 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DDGGGC-P-A-DK00000 EAR99 8504.40.9540 1 960W 9 93% 48V 48V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 3 A 3 A 3 A 3 A
CX10S-DAADAH-P-A-DK00000 Advanced Energy CX10S-DAADAH-P-A-DK00000 -
RFQ
ECAD 3625 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DAADAH-P-A-DK00000 EAR99 8504.40.9540 1 815W 7 93% 48V 5V 5V 48V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 21 A 4.17 A 21 A 6 A
CX10S-GCGA0G-P-A-DK00000 Advanced Energy CX10S-GCGA0G-P-A-DK00000 -
RFQ
ECAD 7251 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GCGA0G-P-A-DK00000 EAR99 8504.40.9540 1 465W 8 93% 24V 24V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 3 A 3 A 21 A
CX10S-D0HCBH-P-A-DK00000 Advanced Energy CX10S-D0HCBH-P-A-DK00000 -
RFQ
ECAD 5888 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-D0HCBH-P-A-DK00000 EAR99 8504.40.9540 1 780W 7 93% 48V 5V 24V 24V 12V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 8.3 A 15 A 6 A
CX10S-DD0GHB-P-A-DK00000 Advanced Energy CX10S-DD0GHB-P-A-DK00000 -
RFQ
ECAD 2217 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DD0GHB-P-A-DK00000 EAR99 8504.40.9540 1 800W 7 93% 48V 48V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 3 A 3 A 6 A 3 A
CX10S-DADBGB-P-A-DK00000 Advanced Energy CX10S-DADBGB-P-A-DK00000 -
RFQ
ECAD 8990 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DADBGB-P-A-DK00000 EAR99 8504.40.9540 1 985W 7 93% 48V 5V 48V 12V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 4.17 A 15 A 3 A 3 A
CX10S-GH0CHH-P-A-DK00000 Advanced Energy CX10S-GH0CHH-P-A-DK00000 -
RFQ
ECAD 4307 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GH0CHH-P-A-DK00000 EAR99 8504.40.9540 1 620W 9 93% 24V 24V 5V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 8.3 A 6 A
CX10S-HC0DB0-P-A-DK00000 Advanced Energy CX10S-HC0DB0-P-A-DK00000 -
RFQ
ECAD 7800 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HC0DB0-P-A-DK00000 EAR99 8504.40.9540 1 680W 5 93% 5V 24V 24V 48V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 8.3 A 4.17 A 15 A
CX10S-DDCDBG-P-A-DK00000 Advanced Energy CX10S-DDCDBG-P-A-DK00000 -
RFQ
ECAD 6703 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DDCDBG-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 48V 48V 24V 48V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 8.3 A 4.17 A 15 A 3 A
CX10S-GDDDC0-P-A-DK00000 Advanced Energy CX10S-GDDDC0-P-A-DK00000 -
RFQ
ECAD 4474 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GDDDC0-P-A-DK00000 EAR99 8504.40.9540 1 920W 6 93% 24V 24V 48V 48V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 4.17 A 4.17 A 8.3 A
CX10S-DC0CGD-P-A-DK00000 Advanced Energy CX10S-DC0CGD-P-A-DK00000 -
RFQ
ECAD 2283 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DC0CGD-P-A-DK00000 EAR99 8504.40.9540 1 720W 6 93% 48V 24V 24V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 8.3 A 3 A 3 A 4.17 A
CX10S-CHGGDD-P-A-DK00000 Advanced Energy CX10S-CHGGDD-P-A-DK00000 -
RFQ
ECAD 1402 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CHGGDD-P-A-DK00000 EAR99 8504.40.9540 1 940W 9 93% 24V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 3 A 3 A 3 A
CX10S-HCHCHA-P-A-DK00000 Advanced Energy CX10S-HCHCHA-P-A-DK00000 -
RFQ
ECAD 7729 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HCHCHA-P-A-DK00000 EAR99 8504.40.9540 1 805W 9 93% 5V 24V 24V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 8.3 A 6 A 3 A 8.3 A
CX10S-DABCCC-P-A-DK00000 Advanced Energy CX10S-DABCCC-P-A-DK00000 -
RFQ
ECAD 9697 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DABCCC-P-A-DK00000 EAR99 8504.40.9540 1 1000W 6 93% 48V 5V 12V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 15 A 8.3 A 8.3 A 8.3 A
CX10S-HHABBG-P-A-DK00000 Advanced Energy CX10S-HHABBG-P-A-DK00000 -
RFQ
ECAD 7840 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HHABBG-P-A-DK00000 EAR99 8504.40.9540 1 785W 9 93% 5V 24V 5V 24V 5V 12V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 6 A 3 A 21 A 15 A
CX10S-G0G0HC-P-A-DK00000 Advanced Energy CX10S-G0G0HC-P-A-DK00000 -
RFQ
ECAD 5541 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0G0HC-P-A-DK00000 EAR99 8504.40.9540 1 540W 7 93% 24V 24V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 6 A 3 A
CX10S-H0GHH0-P-A-DK00000 Advanced Energy CX10S-H0GHH0-P-A-DK00000 -
RFQ
ECAD 2363 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-H0GHH0-P-A-DK00000 EAR99 8504.40.9540 1 420W 8 93% 5V 24V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 3 A 3 A 6 A 3 A
CX10S-CGDC0H-P-A-DK00000 Advanced Energy CX10S-CGDC0H-P-A-DK00000 -
RFQ
ECAD 7545 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CGDC0H-P-A-DK00000 EAR99 8504.40.9540 1 820W 7 93% 24V 24V 24V 48V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 4.17 A 8.3 A 6 A
CX10S-HHD0DC-P-A-DK00000 Advanced Energy CX10S-HHD0DC-P-A-DK00000 -
RFQ
ECAD 1000 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HHD0DC-P-A-DK00000 EAR99 8504.40.9540 1 800W 7 93% 5V 24V 5V 24V 48V 48V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 6 A 3 A 4.17 A 4.17 A
CX10S-HGBCBD-P-A-DK00000 Advanced Energy CX10S-HGBCBD-P-A-DK00000 -
RFQ
ECAD 7680 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HGBCBD-P-A-DK00000 EAR99 8504.40.9540 1 980W 8 93% 5V 24V 24V 24V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 3 A 3 A 15 A 8.3 A
CX10S-DC0CGC-P-A-DK00000 Advanced Energy CX10S-DC0CGC-P-A-DK00000 -
RFQ
ECAD 2853 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DC0CGC-P-A-DK00000 EAR99 8504.40.9540 1 720W 6 93% 48V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 8.3 A 3 A 3 A 8.3 A
CX10S-DG0BC0-P-A-DK00000 Advanced Energy CX10S-DG0BC0-P-A-DK00000 -
RFQ
ECAD 6324 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DG0BC0-P-A-DK00000 EAR99 8504.40.9540 1 700W 5 93% 48V 24V 24V 12V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 15 A 8.3 A
CX10S-DCABAH-P-A-DK00000 Advanced Energy CX10S-DCABAH-P-A-DK00000 -
RFQ
ECAD 7802 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DCABAH-P-A-DK00000 EAR99 8504.40.9540 1 890W 7 93% 48V 24V 5V 12V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 21 A 15 A 21 A 6 A
CX10S-DA0AAC-P-A-DK00000 Advanced Energy CX10S-DA0AAC-P-A-DK00000 -
RFQ
ECAD 1078 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DA0AAC-P-A-DK00000 EAR99 8504.40.9540 1 715W 5 93% 48V 5V 5V 5V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 21 A 21 A 8.3 A
CX10S-DBGHGG-P-A-DK00000 Advanced Energy CX10S-DBGHGG-P-A-DK00000 -
RFQ
ECAD 8298 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DBGHGG-P-A-DK00000 EAR99 8504.40.9540 1 840W 10 93% 48V 12V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 15 A 3 A 3 A 6 A 3 A
CX10S-DABCCG-P-A-DK00000 Advanced Energy CX10S-DABCCG-P-A-DK00000 -
RFQ
ECAD 8622 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DABCCG-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 48V 5V 12V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 15 A 8.3 A 8.3 A 3 A
CX10S-DD0H0C-P-A-DK00000 Advanced Energy CX10S-DD0H0C-P-A-DK00000 -
RFQ
ECAD 1703 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DD0H0C-P-A-DK00000 EAR99 8504.40.9540 1 700W 5 93% 48V 48V 5V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 6 A 3 A 8.3 A
CX10S-GAHH0D-P-A-DK00000 Advanced Energy CX10S-GAHH0D-P-A-DK00000 -
RFQ
ECAD 4689 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GAHH0D-P-A-DK00000 EAR99 8504.40.9540 1 625W 8 93% 24V 24V 5V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 6 A 3 A 6 A
CX10S-DABCGC-P-A-DK00000 Advanced Energy CX10S-DABCGC-P-A-DK00000 -
RFQ
ECAD 6030 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DABCGC-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 48V 5V 12V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 15 A 8.3 A 3 A 3 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse