Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-BABAAC-P-A-DK00000 Advanced Energy CX10S-BABAAC-P-A-DK00000 -
RFQ
ECAD 7284 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BABAAC-P-A-DK00000 EAR99 8504.40.9540 1 875W 6 93% 12V 5V 12V 5V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 21 A 15 A 21 A 21 A 8.3 A
CX10S-CBBDC0-P-A-DK00000 Advanced Energy CX10S-CBBDC0-P-A-DK00000 -
RFQ
ECAD 6891 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CBBDC0-P-A-DK00000 EAR99 8504.40.9540 1 960W 5 93% 24V 12V 12V 48V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 15 A 15 A 4.17 A 8.3 A
CX10S-C00DAA-P-A-DK00000 Advanced Energy CX10S-C00DAA-P-A-DK00000 -
RFQ
ECAD 1967 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C00DAA-P-A-DK00000 EAR99 8504.40.9540 1 610W 4 93% 24V 48V 5V 5V - - No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 4.17 A 21 A 21 A
CX10S-BDBGHD-P-A-DK00000 Advanced Energy CX10S-BDBGHD-P-A-DK00000 -
RFQ
ECAD 7187 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BDBGHD-P-A-DK00000 EAR99 8504.40.9540 1 980W 8 93% 12V 48V 12V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 15 A 4.17 A 15 A 3 A 3 A 6 A
CX10S-BBHDBG-P-A-DK00000 Advanced Energy CX10S-BBHDBG-P-A-DK00000 -
RFQ
ECAD 4689 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BBHDBG-P-A-DK00000 EAR99 8504.40.9540 1 960W 8 93% 12V 12V 5V 24V 48V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 15 A 6 A 3 A 4.17 A 15 A
CX10S-BA0DG0-P-A-DK00000 Advanced Energy CX10S-BA0DG0-P-A-DK00000 -
RFQ
ECAD 1956 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BA0DG0-P-A-DK00000 EAR99 8504.40.9540 1 605W 5 93% 12V 5V 48V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 21 A 4.17 A 3 A 3 A
CX10S-CDGHGD-P-A-DK00000 Advanced Energy CX10S-CDGHGD-P-A-DK00000 -
RFQ
ECAD 8202 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CDGHGD-P-A-DK00000 EAR99 8504.40.9540 1 940W 9 93% 24V 48V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 4.17 A 3 A 3 A 6 A 3 A
CX10S-C00DAB-P-A-DK00000 Advanced Energy CX10S-C00DAB-P-A-DK00000 -
RFQ
ECAD 2975 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C00DAB-P-A-DK00000 EAR99 8504.40.9540 1 685W 4 93% 24V 48V 5V 12V - - No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 4.17 A 21 A 15 A
CX10S-BGBHHB-P-A-DK00000 Advanced Energy CX10S-BGBHHB-P-A-DK00000 -
RFQ
ECAD 6421 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BGBHHB-P-A-DK00000 EAR99 8504.40.9540 1 860W 9 93% 12V 24V 24V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 3 A 3 A 15 A 6 A 3 A
CX10S-BABA0A-P-A-DK00000 Advanced Energy CX10S-BABA0A-P-A-DK00000 -
RFQ
ECAD 3174 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BABA0A-P-A-DK00000 EAR99 8504.40.9540 1 675W 5 93% 12V 5V 12V 5V 5V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 21 A 15 A 21 A 21 A
CX10S-BH0BAC-P-A-DK00000 Advanced Energy CX10S-BH0BAC-P-A-DK00000 -
RFQ
ECAD 9079 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BH0BAC-P-A-DK00000 EAR99 8504.40.9540 1 765W 6 93% 12V 5V 24V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 6 A 3 A 15 A 21 A 8.3 A
CX10S-BHAGDC-P-A-DK00000 Advanced Energy CX10S-BHAGDC-P-A-DK00000 -
RFQ
ECAD 2726 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BHAGDC-P-A-DK00000 EAR99 8504.40.9540 1 905W 8 93% 12V 5V 24V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 6 A 3 A 21 A 3 A 3 A
CX10S-CACHCD-P-A-DK00000 Advanced Energy CX10S-CACHCD-P-A-DK00000 -
RFQ
ECAD 2484 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CACHCD-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 24V 5V 24V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 21 A 8.3 A 6 A 3 A 8.3 A
CX10S-BBHDAC-P-A-DK00000 Advanced Energy CX10S-BBHDAC-P-A-DK00000 -
RFQ
ECAD 5773 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BBHDAC-P-A-DK00000 EAR99 8504.40.9540 1 965W 7 93% 12V 12V 5V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 15 A 15 A 6 A 3 A 4.17 A 21 A
CX10S-B0DHBA-P-A-DK00000 Advanced Energy CX10S-B0DHBA-P-A-DK00000 -
RFQ
ECAD 7788 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-B0DHBA-P-A-DK00000 EAR99 8504.40.9540 1 765W 6 93% 12V 48V 5V 24V 12V 5V No 4 kV 60601-1; 60950-1; 62368-1 15 A 4.17 A 6 A 3 A 15 A 21 A
CX10S-BCCH0C-P-A-DK00000 Advanced Energy CX10S-BCCH0C-P-A-DK00000 -
RFQ
ECAD 1511 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BCCH0C-P-A-DK00000 EAR99 8504.40.9540 1 680W 6 93% 12V 24V 24V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 8.3 A 6 A 3 A 8.3 A
CX10S-BBBBHH-P-A-DK00000 Advanced Energy CX10S-BBBBHH-P-A-DK00000 -
RFQ
ECAD 3922 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BBBBHH-P-A-DK00000 EAR99 8504.40.9540 1 920W 8 93% 12V 12V 12V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 15 A 15 A 15 A 6 A 3 A
CX10S-CCGGHG-P-A-DK00000 Advanced Energy CX10S-CCGGHG-P-A-DK00000 -
RFQ
ECAD 1187 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CCGGHG-P-A-DK00000 EAR99 8504.40.9540 1 860W 10 93% 24V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 3 A 3 A 3 A 3 A
CX10S-BCGCCA-P-A-DK00000 Advanced Energy CX10S-BCGCCA-P-A-DK00000 -
RFQ
ECAD 4226 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BCGCCA-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 12V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 3 A 3 A 8.3 A 8.3 A
CX10S-CBGDCG-P-A-DK00000 Advanced Energy CX10S-CBGDCG-P-A-DK00000 -
RFQ
ECAD 6173 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CBGDCG-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 24V 12V 24V 24V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 15 A 3 A 3 A 4.17 A 8.3 A
CX10S-C00DCA-P-A-DK00000 Advanced Energy CX10S-C00DCA-P-A-DK00000 -
RFQ
ECAD 7680 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C00DCA-P-A-DK00000 EAR99 8504.40.9540 1 705W 4 93% 24V 48V 24V 5V - - No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 4.17 A 8.3 A 21 A
CX10S-BGADCG-P-A-DK00000 Advanced Energy CX10S-BGADCG-P-A-DK00000 -
RFQ
ECAD 6978 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BGADCG-P-A-DK00000 EAR99 8504.40.9540 1 925W 8 93% 12V 24V 24V 5V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 3 A 3 A 21 A 4.17 A 8.3 A
CX10S-BBGB0C-P-A-DK00000 Advanced Energy CX10S-BBGB0C-P-A-DK00000 -
RFQ
ECAD 5174 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BBGB0C-P-A-DK00000 EAR99 8504.40.9540 1 860W 6 93% 12V 12V 24V 24V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 15 A 3 A 3 A 15 A 8.3 A
CX10S-AHDGGA-P-A-DK00000 Advanced Energy CX10S-AHDGGA-P-A-DK00000 -
RFQ
ECAD 7611 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AHDGGA-P-A-DK00000 EAR99 8504.40.9540 1 750W 9 93% 5V 5V 24V 48V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 6 A 3 A 4.17 A 3 A 3 A
CX10S-AHDGGH-P-A-DK00000 Advanced Energy CX10S-AHDGGH-P-A-DK00000 -
RFQ
ECAD 5639 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AHDGGH-P-A-DK00000 EAR99 8504.40.9540 1 745W 10 93% 5V 5V 24V 48V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 6 A 3 A 4.17 A 3 A 3 A
CX10S-C0G0GA-P-A-DK00000 Advanced Energy CX10S-C0G0GA-P-A-DK00000 -
RFQ
ECAD 3772 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C0G0GA-P-A-DK00000 EAR99 8504.40.9540 1 545W 6 93% 24V 24V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 3 A 3 A 21 A
CX10S-BHAHB0-P-A-DK00000 Advanced Energy CX10S-BHAHB0-P-A-DK00000 -
RFQ
ECAD 6422 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BHAHB0-P-A-DK00000 EAR99 8504.40.9540 1 665W 7 93% 12V 5V 24V 5V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 6 A 3 A 21 A 6 A 3 A
CX10S-C00CHH-P-A-DK00000 Advanced Energy CX10S-C00CHH-P-A-DK00000 -
RFQ
ECAD 8284 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C00CHH-P-A-DK00000 EAR99 8504.40.9540 1 600W 6 93% 24V 24V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 6 A 3 A 6 A 3 A
CX10S-C0CCGH-P-A-DK00000 Advanced Energy CX10S-C0CCGH-P-A-DK00000 -
RFQ
ECAD 6235 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C0CCGH-P-A-DK00000 EAR99 8504.40.9540 1 820W 7 93% 24V 24V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 8.3 A 3 A 3 A 6 A
CX10S-CGB0B0-P-A-DK00000 Advanced Energy CX10S-CGB0B0-P-A-DK00000 -
RFQ
ECAD 1237 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CGB0B0-P-A-DK00000 EAR99 8504.40.9540 1 680W 5 93% 24V 24V 24V 12V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 15 A 15 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse