Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CX10S-0HCBAH-P-A-DK00000 | - | ![]() |
8142 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0HCBAH-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 685W | 7 | 93% | 5V | 24V | 24V | 12V | 5V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 8.3 A | 15 A | 21 A | 6 A | |
![]() |
CX10S-CDC0CH-P-A-DK00000 | - | ![]() |
9039 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-CDC0CH-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 900W | 6 | 93% | 24V | 48V | 24V | 24V | 5V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 4.17 A | 8.3 A | 8.3 A | 6 A | 3 A | |
![]() |
CX10S-CADADC-P-A-DK00000 | - | ![]() |
2682 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-CADADC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 1000W | 6 | 93% | 24V | 5V | 48V | 5V | 48V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 21 A | 4.17 A | 21 A | 4.17 A | 8.3 A | |
![]() |
CX10S-BABCHB-P-A-DK00000 | - | ![]() |
7859 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-BABCHB-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 945W | 7 | 93% | 12V | 5V | 12V | 24V | 5V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 15 A | 21 A | 15 A | 8.3 A | 6 A | 3 A | |
![]() |
CX10S-BHHACD-P-A-DK00000 | - | ![]() |
5536 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-BHHACD-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 885W | 8 | 93% | 12V | 5V | 24V | 5V | 24V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 15 A | 6 A | 3 A | 6 A | 3 A | 21 A | |
![]() |
CX10S-HGBGDA-P-A-DK00000 | - | ![]() |
3956 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-HGBGDA-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 825W | 9 | 93% | 5V | 24V | 24V | 24V | 12V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 3 A | 3 A | 15 A | 3 A | |
![]() |
CX10S-HCG0BD-P-A-DK00000 | - | ![]() |
4795 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-HCG0BD-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 600W | 7 | 93% | 5V | 24V | 24V | 24V | 24V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 8.3 A | 3 A | 3 A | 15 A | |
![]() |
CX10S-CDDHDH-P-A-DK00000 | - | ![]() |
6435 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-CDDHDH-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 1000W | 8 | 93% | 24V | 48V | 48V | 5V | 24V | 48V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 4.17 A | 4.17 A | 6 A | 3 A | 4.17 A | |
![]() |
CX10S-00GAGC-P-A-DK00000 | - | ![]() |
4853 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-00GAGC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 545W | 6 | 93% | 24V | 24V | 5V | 24V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 3 A | 3 A | 21 A | 3 A | 3 A | 8.3 A | |
![]() |
CX10S-0H0CHD-P-A-DK00000 | - | ![]() |
9824 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0H0CHD-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 600W | 6 | 93% | 5V | 24V | 24V | 5V | 24V | 48V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 8.3 A | 6 A | 3 A | 4.17 A | |
![]() |
CX10S-DCH0AC-P-A-DK00000 | - | ![]() |
7069 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-DCH0AC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 605W | 6 | 93% | 48V | 24V | 5V | 24V | 5V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 4.17 A | 8.3 A | 6 A | 3 A | 21 A | 8.3 A | |
![]() |
CX10S-BBBAA0-P-A-DK00000 | - | ![]() |
9723 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-BBBAA0-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 750W | 5 | 93% | 12V | 12V | 12V | 5V | 5V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 15 A | 15 A | 15 A | 21 A | 21 A | ||
![]() |
CX10S-HGCHHC-P-A-DK00000 | - | ![]() |
6074 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-HGCHHC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 820W | 10 | 93% | 5V | 24V | 24V | 24V | 24V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 3 A | 3 A | 8.3 A | 6 A | |
![]() |
CX10S-B0ABG0-P-A-DK00000 | - | ![]() |
2291 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-B0ABG0-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 585W | 5 | 93% | 12V | 5V | 12V | 24V | 24V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 15 A | 21 A | 15 A | 3 A | 3 A | ||
![]() |
CX10S-HHABDB-P-A-DK00000 | - | ![]() |
6715 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-HHABDB-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 865W | 8 | 93% | 5V | 24V | 5V | 24V | 5V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 6 A | 3 A | 21 A | 15 A | |
![]() |
CX10S-HDBBHG-P-A-DK00000 | - | ![]() |
9207 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-HDBBHG-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 880W | 9 | 93% | 5V | 24V | 48V | 12V | 12V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 4.17 A | 15 A | 15 A | 6 A | |
![]() |
CX10S-ADH0G0-P-A-DK00000 | - | ![]() |
7560 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-ADH0G0-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 525W | 6 | 93% | 5V | 48V | 5V | 24V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 4.17 A | 6 A | 3 A | 3 A | 3 A | |
![]() |
CX10S-HDAG0H-P-A-DK00000 | - | ![]() |
8459 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-HDAG0H-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 625W | 8 | 93% | 5V | 24V | 48V | 5V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 4.17 A | 21 A | 3 A | 3 A | |
![]() |
CX10S-HDCDHC-P-A-DK00000 | - | ![]() |
8949 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-HDCDHC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 1000W | 8 | 93% | 5V | 24V | 48V | 24V | 48V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 4.17 A | 8.3 A | 4.17 A | 6 A | |
![]() |
CX10S-0BCHHG-P-A-DK00000 | - | ![]() |
4550 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0BCHHG-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 700W | 8 | 93% | 12V | 24V | 5V | 24V | 5V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 15 A | 8.3 A | 6 A | 3 A | 6 A | 3 A | |
![]() |
CX10S-HCCCCB-P-A-DK00000 | - | ![]() |
5460 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-HCCCCB-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 1000W | 7 | 93% | 5V | 24V | 24V | 24V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 8.3 A | 8.3 A | 8.3 A | 8.3 A | |
![]() |
CX10S-HDCGHG-P-A-DK00000 | - | ![]() |
2183 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-HDCGHG-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 840W | 10 | 93% | 5V | 24V | 48V | 24V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 4.17 A | 8.3 A | 3 A | 3 A | |
![]() |
CX10S-ADAHHH-P-A-DK00000 | - | ![]() |
1785 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-ADAHHH-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 710W | 9 | 93% | 5V | 48V | 5V | 5V | 24V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 4.17 A | 21 A | 6 A | 3 A | 6 A | |
![]() |
CX10S-0DB0HB-P-A-DK00000 | - | ![]() |
1411 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0DB0HB-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 660W | 5 | 93% | 48V | 12V | 5V | 24V | 12V | 48V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 4.17 A | 15 A | 6 A | 3 A | 15 A | ||
![]() |
CX10S-BGH0BH-P-A-DK00000 | - | ![]() |
9480 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-BGH0BH-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 680W | 8 | 93% | 12V | 24V | 24V | 5V | 24V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 15 A | 3 A | 3 A | 6 A | 3 A | 15 A | |
![]() |
CX10S-A0GDGD-P-A-DK00000 | - | ![]() |
6933 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-A0GDGD-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 745W | 7 | 93% | 5V | 24V | 24V | 48V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 3 A | 3 A | 4.17 A | 3 A | 3 A | |
![]() |
CX10S-BGDBDG-P-A-DK00000 | - | ![]() |
9361 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-BGDBDG-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 1000W | 8 | 93% | 12V | 24V | 24V | 48V | 12V | 48V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 15 A | 3 A | 3 A | 4.17 A | 15 A | 4.17 A | |
![]() |
CX10S-DHH0CH-P-A-DK00000 | - | ![]() |
5720 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-DHH0CH-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 700W | 8 | 93% | 48V | 5V | 24V | 5V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 4.17 A | 6 A | 3 A | 6 A | 3 A | 8.3 A | |
![]() |
CX10S-CD00BC-P-A-DK00000 | - | ![]() |
8977 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-CD00BC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 780W | 4 | 93% | 24V | 48V | 12V | 24V | - | - | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 4.17 A | 15 A | 8.3 A | |||
![]() |
CX10S-B0ACBA-P-A-DK00000 | - | ![]() |
7005 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-B0ACBA-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 770W | 5 | 93% | 12V | 5V | 24V | 12V | 5V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 15 A | 21 A | 8.3 A | 15 A | 21 A |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse