Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Approval Agency Voltage - Input DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4
101190104 Integrated Power Designs 101190104 472.8500
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 4 87% 5V 15V 15V -15V - - - 60601-1; 62368-1 40 A 10 A 5 A 5 A
101189502 Integrated Power Designs 101189502 420.1800
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 2 87% 5V 28V - - - - - 60601-1; 62368-1 40 A 5 A
101190702 Integrated Power Designs 101190702 433.5100
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 2 87% 15V -15V - - - - - 60601-1; 62368-1 20 A 10 A
101189501 Integrated Power Designs 101189501 420.1800
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 2 87% 5V 24V - - - - - 60601-1; 62368-1 40 A 5 A
101191002 Integrated Power Designs 101191002 486.1800
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 4 87% 5V 15V 12V -12V - - - 60601-1; 62368-1 40 A 10 A 5 A 5 A
101191302 Integrated Power Designs 101191302 440.1800
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 2 87% 5V 28V - - - - - 60601-1; 62368-1 40 A 5 A
101189003 Integrated Power Designs 101189003 446.9800
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 3 87% 5V 12V - -15V - - - 60601-1; 62368-1 40 A 10 A 5 A
101190602 Integrated Power Designs 101190602 433.5100
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 2 87% 12V -15V - - - - - 60601-1; 62368-1 25 A 10 A
101189903 Integrated Power Designs 101189903 453.6500
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 3 87% 5V 12V - -15V - - - 60601-1; 62368-1 40 A 10 A 5 A
101189001 Integrated Power Designs 101189001 446.9800
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 3 87% 5V 12V - - - - - 60601-1; 62368-1 40 A 10 A 5 A
101190802 Integrated Power Designs 101190802 466.9800
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 3 87% 5V 15V - -12V - - - 60601-1; 62368-1 40 A 10 A 5 A
101191501 Integrated Power Designs 101191501 440.1800
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 2 87% 12V -12V - - - - - 60601-1; 62368-1 25 A 10 A
101191703 Integrated Power Designs 101191703 473.6500
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 3 87% 5V 12V - -15V - - - 60601-1; 62368-1 40 A 10 A 5 A
101190902 Integrated Power Designs 101190902 486.1800
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 4 87% 5V 5V 12V -12V - - - 60601-1; 62368-1 40 A 15 A 5 A 5 A
101188801 Integrated Power Designs 101188801 413.5100
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 2 87% 12V -12V - - - - - 60601-1; 62368-1 25 A 10 A
101192104 Integrated Power Designs 101192104 492.8500
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 4 87% 24V -28V 15V -15V - - - 60601-1; 62368-1 12.5 A 5 A 5 A 5 A
101189401 Integrated Power Designs 101189401 466.1800
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 4 87% 24V -24V 12V -12V - - - 60601-1; 62368-1 12.5 A 5 A 5 A 5 A
101189404 Integrated Power Designs 101189404 466.1800
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 4 87% 24V -28V 15V -15V - - - 60601-1; 62368-1 12.5 A 5 A 5 A 5 A
101188602 Integrated Power Designs 101188602 413.5100
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 2 87% 5V 28V - - - - - 60601-1; 62368-1 40 A 5 A
101190903 Integrated Power Designs 101190903 486.1800
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 4 87% 5V 3.3V 15V -15V - - - 60601-1; 62368-1 40 A 15 A 5 A 5 A
101190402 Integrated Power Designs 101190402 433.5100
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 2 87% 5V 28V - - - - - 60601-1; 62368-1 40 A 5 A
101188702 Integrated Power Designs 101188702 413.5100
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 2 87% 5V 15V - - - - - 60601-1; 62368-1 40 A 10 A
101191704 Integrated Power Designs 101191704 473.6500
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 3 87% 5V 15V - -15V - - - 60601-1; 62368-1 40 A 10 A 5 A
101190301 Integrated Power Designs 101190301 472.8500
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 4 87% 24V -24V 12V -12V - - - 60601-1; 62368-1 12.5 A 5 A 5 A 5 A
101190901 Integrated Power Designs 101190901 486.1800
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 4 87% 5V 3.3V 12V -12V - - - 60601-1; 62368-1 40 A 15 A 5 A 5 A
101189102 Integrated Power Designs 101189102 466.1800
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 4 87% 5V 5V 12V -12V - - - 60601-1; 62368-1 40 A 15 A 5 A 5 A
1011768CHCO Integrated Power Designs 1011768CHCO 209.0300
RFQ
ECAD 50 0.00000000 Integrated Power Designs GRN-360 (360W) Box Active -20°C ~ 70°C (With Derating) Industrial, ITE (Commercial), Laboratory, Medical 5.10" L x 3.16" W x 1.80" H (129.54mm x 80.26mm x 45.72mm) Chassis Mount Enclosed Universal Input CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 2625-1011768CHCO EAR99 8504.40.6007 1 360W 1 93% 24V - - - - 60601-1; 62368-1 15 A
1011767CHCO Integrated Power Designs 1011767CHCO 209.0300
RFQ
ECAD 50 0.00000000 Integrated Power Designs GRN-360 (360W) Box Active -20°C ~ 70°C (With Derating) Industrial, ITE (Commercial), Laboratory, Medical 5.10" L x 3.16" W x 1.80" H (129.54mm x 80.26mm x 45.72mm) Chassis Mount Enclosed Universal Input CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 2625-1011767CHCO EAR99 8504.40.6007 1 360W 1 93% 18V - - - - 60601-1; 62368-1 20 A
1011765 Integrated Power Designs 1011765 185.6900
RFQ
ECAD 1 0.00000000 Integrated Power Designs GRN-360 (360W) Box Active -20°C ~ 70°C (With Derating) Industrial, ITE (Commercial), Laboratory, Medical 5.00" L x 3.00" W x 1.49" H (127.0mm x 76.1mm x 37.8mm) Chassis Mount Open Frame Universal Input CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 2625-1011765 EAR99 8504.40.6007 1 360W 1 93% 12V - - - - 60601-1; 62368-1 30 A
1011770CHCO Integrated Power Designs 1011770CHCO 209.0300
RFQ
ECAD 40 0.00000000 Integrated Power Designs GRN-360 (360W) Box Active -20°C ~ 70°C (With Derating) Industrial, ITE (Commercial), Laboratory, Medical 5.10" L x 3.16" W x 1.80" H (129.54mm x 80.26mm x 45.72mm) Chassis Mount Enclosed Universal Input CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 2625-1011770CHCO EAR99 8504.40.6007 1 360W 1 93% 48V - - - - 60601-1; 62368-1 7.5 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse