SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4
101191101 Integrated Power Designs 101191101 486.1800
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 4 87% 5V 24V 12V -12V - - - 60601-1; 62368-1 40 A 5 A 5 A 5 A
1011010CH Integrated Power Designs 1011010CH 348.1600
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-325 (350W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 6.20" L x 4.00" W x 1.75" H (157.5mm x 101.6mm x 44.5mm) Chassis Mount Chassis Adjustable Output, Remote Sense, Universal Input 1011010 CE, cURus, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 325W 1 85% 2.5V - - - - - - 60601-1; 62368-1 65 A
1010949CH Integrated Power Designs 1010949CH 487.6400
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.28" L x 4.00" W x 1.80" H (210.4mm x 101.6mm x 45.7mm) Chassis Mount Chassis Adjustable Output, Remote Sense, Universal Input 1010949 CE, cURus, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 400W 1 85% 28V - - - - - - 60601-1; 62368-1 14.3 A
1010976 Integrated Power Designs 1010976 147.8100
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-100 (100W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.50" L x 2.50" W x 1.00" H (114.3mm x 63.5mm x 25.4mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Universal Input CE, cURus, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 100W 1 85% 3.3V - - - - - - 60601-1; 62368-1 20 A
1011353CHCO Integrated Power Designs 1011353CHCO 131.1500
RFQ
ECAD 50 0.00000000 Integrated Power Designs GRN-200 (200W) Box Active 0°C ~ 70°C (With Derating) Industrial, ITE (Commercial), Laboratory, Medical 5.00" L x 3.14" W x 1.65" H (127.0mm x 79.9mm x 41.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input 1011353 CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 200W 4 87% 3.5V 5.2V 18V -18V - - 60601-1; 62368-1 3.5 A 1 A 1.5 A 1.5 A
1011211CHCO Integrated Power Designs 1011211CHCO 129.8400
RFQ
ECAD 50 0.00000000 Integrated Power Designs REL-70 (70W) Box Active 0°C ~ 70°C (With Derating) Industrial, ITE (Commercial), Laboratory, Medical 4.79" L x 2.62" W x 1.48" H (121.6mm x 66.5mm x 37.6mm) Chassis Mount Enclosed Adjustable Output, Universal Input 1011211 CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 70W 3 78% 5V 15V - -15V - - 60601-1; 62368-1 6 A 2 A 2 A
1010985 Integrated Power Designs 1010985 144.4700
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-100 (100W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.50" L x 2.50" W x 1.00" H (114.3mm x 63.5mm x 25.4mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Universal Input CE, cURus, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 100W 1 85% 5V - - - - - - 60601-1; 62368-1 20 A
101190904 Integrated Power Designs 101190904 486.1800
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.40" L x 4.15" W x 1.61" H (213.4mm x 105.4mm x 40.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 400W 4 87% 5V 5V 15V -15V - - - 60601-1; 62368-1 40 A 15 A 5 A 5 A
1011328CH Integrated Power Designs 1011328CH 181.2400
RFQ
ECAD 50 0.00000000 Integrated Power Designs REL-110 (110W) Box Active 0°C ~ 70°C (With Derating) Industrial, ITE (Commercial), Laboratory, Medical 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) Chassis Mount Chassis Adjustable Output, Universal Input 1011328 CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 110W 4 82% 5V -9V 15V -15V - - 60601-1; 62368-1 10 A 3 A 2 A 2 A
101188003 Integrated Power Designs 101188003 437.3600
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 7.00" L x 4.00" W x 1.50" H (177.8mm x 101.6mm x 38.0mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Universal Input CE, cURus, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 400W 3 87% 5V 12V - -15V - - - 60601-1; 62368-1 50 A 10 A 5 A
1010927CHCO Integrated Power Designs 1010927CHCO 484.3100
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.28" L x 4.00" W x 1.80" H (210.4mm x 101.6mm x 45.7mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input 1010927 CE, cURus, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 400W 1 85% 2.5V - - - - - - 60601-1; 62368-1 80 A
1010872CHCO Integrated Power Designs 1010872CHCO 248.8300
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-225 (225W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 5.24" L x 3.12" W x 1.75" H (133.1mm x 79.2mm x 44.5mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input 1010872 CE, cURus, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 225W 1 85% 5V - - - - - - 60601-1; 62368-1 45 A
1010918CHCO Integrated Power Designs 1010918CHCO 187.9100
RFQ
ECAD 50 0.00000000 Integrated Power Designs REL-110 (110W) Box Active 0°C ~ 70°C (With Derating) Industrial, ITE (Commercial), Laboratory, Medical 5.25" L x 3.12" W x 1.48" H (133.4mm x 79.2mm x 37.6mm) Chassis Mount Enclosed Adjustable Output, Universal Input 1010918 CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 110W 4 82% 9V 24V 15V 15V - - 60601-1; 62368-1 6 A 2 A 2 A 2 A
1010391 Integrated Power Designs 1010391 68.1500
RFQ
ECAD 37 0.00000000 Integrated Power Designs SRP-40A (40W) Box Active 0°C ~ 70°C (With Derating) Industrial, ITE (Commercial), Medical 4.25" L x 2.50" W x 1.20" H (107.9mm x 63.5mm x 30.5mm) Chassis Mount Open Frame Adjustable Output, Universal Input CE, cURus, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 40W 2 73% 15V -15V - - - - - 60601-1; 62368-1 2.5 A 2 A
1010189 Integrated Power Designs 1010189 648.8900
RFQ
ECAD 50 0.00000000 Integrated Power Designs CE-300 (300W) Box Not For New Designs 0°C ~ 50°C (With Derating) ITE (Commercial) 8.50" L x 4.90" W x 1.95" H (215.9mm x 124.5mm x 49.5mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input CE, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 1 300W 1 55% 5V - - - - - 62368-1 60 A
1010414CHCO Integrated Power Designs 1010414CHCO 219.0300
RFQ
ECAD 50 0.00000000 Integrated Power Designs SRW-100 (100W) Box Active 0°C ~ 70°C (With Derating) Industrial, ITE (Commercial), Medical 5.00" L x 3.30" W x 1.75" H (127.0mm x 83.8mm x 44.5mm) Chassis Mount Enclosed Adjustable Output, Universal Input 1010414 CE, cURus, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 100W 4 76% 5V 15V 12V -12V - - - 60601-1; 62368-1 10 A 3 A 2 A 1 A
1011377 Integrated Power Designs 1011377 116.7500
RFQ
ECAD 50 0.00000000 Integrated Power Designs GRN-110 (110W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 5.00" L x 3.00" W x 1.06" H (127.0mm x 76.2mm x 26.9mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Universal Input CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 110W 2 85% 5V 24V - - - - No 60601-1; 62368-1 12 A 3 A
1011362 Integrated Power Designs 1011362 89.6800
RFQ
ECAD 50 0.00000000 Integrated Power Designs GRN-80 (80W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.25" L x 2.50" W x 0.83" H (108.0mm x 63.5mm x 21.1mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Universal Input CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 80W 1 82% 3.3V - - - - - No 60601-1; 62368-1 16 A
1011407 Integrated Power Designs 1011407 62.7200
RFQ
ECAD 1 0.00000000 Integrated Power Designs GRN-60 (60W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 3.00" L x 2.00" W x 0.83" H (76.2mm x 50.8mm x 21.1mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Universal Input CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 60W 1 87% 48V - - - - - No 60601-1; 62368-1 1.3 A
1011377CH Integrated Power Designs 1011377CH 123.4200
RFQ
ECAD 50 0.00000000 Integrated Power Designs GRN-110 (110W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 5.25" L x 3.25" W x 1.50" H (133.4mm x 82.6mm x 38.1mm) Chassis Mount Chassis Adjustable Output, Remote Sense, Universal Input GRN-110 CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 132W 2 85% 5V 24V - - - - No 60601-1; 62368-1 12 A 3 A
1011277CHCO Integrated Power Designs 1011277CHCO 96.3500
RFQ
ECAD 50 0.00000000 Integrated Power Designs GRN-80 (80W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.50" L x 2.75" W x 1.28" H (114.3mm x 69.9mm x 32.5mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input GRN-80 CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 53W 1 82% 3.3V - - - - - No 60601-1; 62368-1 16 A
1011396CH Integrated Power Designs 1011396CH 90.7500
RFQ
ECAD 50 0.00000000 Integrated Power Designs GRN-45 (45W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.50" L x 2.75" W x 1.28" H (114.3mm x 69.9mm x 32.5mm) Chassis Mount Chassis Adjustable Output, Universal Input GRN-45 CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 45W 3 85% 5V 15V -15V - - - No 60601-1; 62368-1 5 A 1 A 1 A
1011409CH Integrated Power Designs 1011409CH 117.5200
RFQ
ECAD 50 0.00000000 Integrated Power Designs GRN-110 (110W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 5.25" L x 3.25" W x 1.50" H (133.4mm x 82.6mm x 38.1mm) Chassis Mount Chassis Adjustable Output, Remote Sense, Universal Input GRN-110 CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 73W 1 82% 3.3V - - - - - No 60601-1; 62368-1 22 A
1011246CHCO Integrated Power Designs 1011246CHCO 131.6400
RFQ
ECAD 50 0.00000000 Integrated Power Designs GRN-110 (110W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 5.25" L x 3.25" W x 1.50" H (133.4mm x 82.6mm x 38.1mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input GRN-110 CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 150W 3 85% 5V 15V -15V - - - No 60601-1; 62368-1 12 A 3 A 3 A
1011241CHCO Integrated Power Designs 1011241CHCO 140.0700
RFQ
ECAD 50 0.00000000 Integrated Power Designs GRN-110 (110W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 5.25" L x 3.25" W x 1.50" H (133.4mm x 82.6mm x 38.1mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input GRN-110 CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 106W 4 85% 3.3V 5V 12V -12V - - No 60601-1; 62368-1 10 A 5 A 2 A 2 A
1011414CHCO Integrated Power Designs 1011414CHCO 124.1900
RFQ
ECAD 50 0.00000000 Integrated Power Designs GRN-110 (110W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 5.25" L x 3.25" W x 1.50" H (133.4mm x 82.6mm x 38.1mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input GRN-110 CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 110W 1 87% 28V - - - - - No 60601-1; 62368-1 3.9 A
1011280CHCO Integrated Power Designs 1011280CHCO 96.3500
RFQ
ECAD 50 0.00000000 Integrated Power Designs GRN-80 (80W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.50" L x 2.75" W x 1.28" H (114.3mm x 69.9mm x 32.5mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input GRN-80 CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 80W 1 87% 15V - - - - - No 60601-1; 62368-1 5.3 A
1011362CH Integrated Power Designs 1011362CH 96.3500
RFQ
ECAD 50 0.00000000 Integrated Power Designs GRN-80 (80W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 4.50" L x 2.75" W x 1.28" H (114.3mm x 69.9mm x 32.5mm) Chassis Mount Chassis Adjustable Output, Remote Sense, Universal Input GRN-80 CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 53W 1 82% 3.3V - - - - - No 60601-1; 62368-1 16 A
1011372CH Integrated Power Designs 1011372CH 140.0700
RFQ
ECAD 50 0.00000000 Integrated Power Designs GRN-110 (110W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 5.25" L x 3.25" W x 1.50" H (133.4mm x 82.6mm x 38.1mm) Chassis Mount Chassis Adjustable Output, Remote Sense, Universal Input GRN-110 CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 123W 4 85% 5V -5V 12V -12V - - No 60601-1; 62368-1 10 A 5 A 2 A 2 A
1011439CHCO Integrated Power Designs 1011439CHCO 235.7100
RFQ
ECAD 50 0.00000000 Integrated Power Designs GRN-200 (200W) Box Active -20°C ~ 70°C (With Derating) ITE (Commercial), Medical 5.00" L x 3.14" W x 1.65" H (127.0mm x 79.9mm x 41.9mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input GRN-200 CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 200W 3 89% 5V 15V -15V - - - No 60601-1; 62368-1 30 A 5 A 2 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse