Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
NMP1K2-HH#KEE-00 | 728.6700 | ![]() |
7591 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 24V | 24V | 48V | 12V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 5 A | 20 A | 20 A | ||
![]() |
NMP1K2-HH#KH#-00 | 641.2200 | ![]() |
7855 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 960W | 4 | 88.5% | 24V | 24V | 48V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 5 A | 10 A | ||||
![]() |
NMP1K2-HH#KHE-00 | 728.6700 | ![]() |
3690 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 24V | 24V | 48V | 24V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 5 A | 10 A | 20 A | ||
![]() |
NMP1K2-HH#KK#-00 | 610.9800 | ![]() |
1117 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 960W | 4 | 88.5% | 24V | 24V | 48V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 5 A | 5 A | ||||
![]() |
NMP1K2-HHC#C#-00 | 641.2200 | ![]() |
8122 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 840W | 4 | 88.5% | 24V | 24V | 5V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 36 A | ||||
![]() |
NMP1K2-HHC#CK-00 | 728.6700 | ![]() |
9008 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 24V | 24V | 5V | 5V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 36 A | 5 A | ||
![]() |
NMP1K2-HHC#EC-00 | 728.6700 | ![]() |
5192 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 24V | 24V | 5V | 12V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 20 A | 36 A | ||
![]() |
NMP1K2-HHC#H#-00 | 641.2200 | ![]() |
3635 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 900W | 4 | 88.5% | 24V | 24V | 5V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 10 A | ||||
![]() |
NMP1K2-HHC#HC-00 | 728.6700 | ![]() |
7170 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 24V | 24V | 5V | 24V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 10 A | 36 A | ||
![]() |
NMP1K2-HHC#HK-00 | 728.6700 | ![]() |
4507 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 24V | 24V | 5V | 24V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 10 A | 5 A | ||
![]() |
NMP1K2-HHC#KE-00 | 728.6700 | ![]() |
7323 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 24V | 24V | 5V | 48V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 5 A | 20 A | ||
![]() |
NMP1K2-HHCC#H-00 | 728.6700 | ![]() |
5610 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 24V | 24V | 5V | 5V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 36 A | 10 A | ||
![]() |
NMP1K2-HHCCCE-00 | 816.1200 | ![]() |
7414 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 24V | 5V | 5V | 5V | 12V | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 36 A | 36 A | 20 A | |
![]() |
NMP1K2-HHCCE#-00 | 728.6700 | ![]() |
2663 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 24V | 24V | 5V | 5V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 36 A | 20 A | ||
![]() |
NMP1K2-HHCCEE-00 | 777.6200 | ![]() |
5333 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 24V | 5V | 5V | 12V | 12V | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 36 A | 20 A | 20 A | |
![]() |
NMP1K2-HHCCEH-00 | 816.1200 | ![]() |
5601 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 24V | 5V | 5V | 12V | 24V | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 36 A | 20 A | 10 A | |
![]() |
NMP1K2-HHCCH#-00 | 728.6700 | ![]() |
8966 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 24V | 24V | 5V | 5V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 36 A | 10 A | ||
![]() |
NMP1K2-HHCCK#-00 | 728.6700 | ![]() |
3405 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 24V | 24V | 5V | 5V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 36 A | 5 A | ||
![]() |
NMP1K2-HHCCKC-00 | 816.1200 | ![]() |
7679 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 24V | 5V | 5V | 48V | 5V | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 36 A | 5 A | 36 A | |
![]() |
NMP1K2-HHCCKH-00 | 777.6200 | ![]() |
6764 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 24V | 5V | 5V | 48V | 24V | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 36 A | 5 A | 10 A | |
![]() |
NMP1K2-HHCE##-00 | 641.2200 | ![]() |
3108 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 900W | 4 | 88.5% | 24V | 24V | 5V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 20 A | ||||
![]() |
NMP1K2-HHCE#K-00 | 728.6700 | ![]() |
6013 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 24V | 24V | 5V | 12V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 20 A | 5 A | ||
![]() |
NMP1K2-HHCEC#-00 | 728.6700 | ![]() |
4195 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 24V | 24V | 5V | 12V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 20 A | 36 A | ||
![]() |
NMP1K2-HHCECC-00 | 816.1200 | ![]() |
1217 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 24V | 5V | 12V | 5V | 5V | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 20 A | 36 A | 36 A | |
![]() |
NMP1K2-HHCECK-00 | 816.1200 | ![]() |
8324 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 24V | 5V | 12V | 5V | 48V | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 20 A | 36 A | 5 A | |
![]() |
NMP1K2-HHCEEE-00 | 816.1200 | ![]() |
2561 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 24V | 5V | 12V | 12V | 12V | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 20 A | 20 A | 20 A | |
![]() |
NMP1K2-HHCEEH-00 | 816.1200 | ![]() |
6858 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 24V | 5V | 12V | 12V | 24V | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 20 A | 20 A | 10 A | |
![]() |
NMP1K2-HHCEEK-00 | 816.1200 | ![]() |
6886 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 24V | 5V | 12V | 12V | 48V | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 20 A | 20 A | 5 A | |
![]() |
NMP1K2-HHCEHC-00 | 816.1200 | ![]() |
1491 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 24V | 5V | 12V | 24V | 5V | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 20 A | 10 A | 36 A | |
![]() |
NMP1K2-HHCEHE-00 | 816.1200 | ![]() |
9891 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 24V | 5V | 12V | 24V | 12V | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 20 A | 10 A | 20 A |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse