Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
NMP1K2-CEH#EK-00 | 728.6700 | ![]() |
8076 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 5V | 12V | 24V | 12V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 36 A | 20 A | 10 A | 20 A | 5 A | ||
![]() |
NMP1K2-HEHE#C-00 | 728.6700 | ![]() |
5435 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 24V | 12V | 24V | 12V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 10 A | 20 A | 36 A | ||
![]() |
NMP1K2-KKEECH-01 | 782.3100 | ![]() |
8497 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 48V | 12V | 12V | 5V | 24V | - | 4 kV | 60601-1; 62368-1 | 5 A | 5 A | 20 A | 20 A | 36 A | 10 A | |
![]() |
NMP1K2-HECC#K-00 | 694.3000 | ![]() |
8772 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 24V | 12V | 5V | 5V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 36 A | 36 A | 5 A | ||
![]() |
NES-200-36 | - | ![]() |
6962 | 0.00000000 | MEAN WELL USA Inc. | NES-200 (200W) | Box | Obsolete | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 8.46" L x 4.53" W x 1.97" H (215.0mm x 115.0mm x 50.0mm) | Chassis Mount | Enclosed | Adjustable Output | cURus | 90 ~ 132 VAC, 180 ~ 264 VAC, 254 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9530 | 1 | 212W | 1 | 89% | 36V | - | - | - | - | No | 3 kV | 5.9 A | |||||||||
![]() |
NMP1K2-#KKKHE-03 | 733.5900 | ![]() |
8916 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 4 | 88.5% | 48V | 48V | 24V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 5 A | 10 A | 10 A | 20 A | ||||
![]() |
NMP1K2-#HHHEK-00 | 728.6700 | ![]() |
8417 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 24V | 24V | 24V | 12V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 10 A | 20 A | 5 A | ||
![]() |
NMP1K2-HKCCC#-04 | 733.5900 | ![]() |
7656 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1020W | 4 | 88.5% | 24V | 48V | 5V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 36 A | 72 A | ||||
![]() |
NMP1K2-CCH##H-00 | 610.9800 | ![]() |
8176 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 840W | 4 | 88.5% | 5V | 5V | 24V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 36 A | 36 A | 10 A | 10 A | ||||
![]() |
NMP1K2-KEKHEE-05 | 821.0300 | ![]() |
3575 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 48V | 12V | 48V | 24V | 12V | 12V | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 5 A | 10 A | 20 A | 20 A | |
![]() |
NMP1K2-KE#KCC-05 | 733.5900 | ![]() |
3445 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 4 | 88.5% | 48V | 12V | 48V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 5 A | 72 A | ||||
![]() |
NMP1K2-KCCEEE-00 | 816.1200 | ![]() |
3974 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 48V | 5V | 5V | 12V | 12V | 12V | - | 4 kV | 60601-1; 62368-1 | 5 A | 36 A | 36 A | 20 A | 20 A | 20 A | |
![]() |
NMP1K2-H##CHK-00 | 641.2200 | ![]() |
1945 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 900W | 4 | 88.5% | 24V | 5V | 24V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 36 A | 10 A | 5 A | ||||
![]() |
NMP650-#KEE-00 | 473.5900 | ![]() |
6339 | 0.00000000 | MEAN WELL USA Inc. | NMP (650W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 3.50" W x 1.61" H (250.0mm x 89.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP650 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 650W | 3 | 88.5% | 48V | 12V | 12V | - | - | - | 4 kV | 60601-1; 62368-1 | 5 A | 20 A | 20 A | |||||
![]() |
NMP1K2-CC#E##-00 | 553.7800 | ![]() |
9177 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 600W | 3 | 88.5% | 5V | 5V | 12V | - | - | - | 4 kV | 60601-1; 62368-1 | 36 A | 36 A | 20 A | |||||
![]() |
NMP650-EHCE-00 | 534.5700 | ![]() |
3417 | 0.00000000 | MEAN WELL USA Inc. | NMP (650W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 3.50" W x 1.61" H (250.0mm x 89.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP650 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 650W | 4 | 88.5% | 12V | 24V | 5V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 10 A | 36 A | 20 A | ||||
![]() |
NMP1K2-#HCCH#-00 | 641.2200 | ![]() |
8722 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 840W | 4 | 88.5% | 24V | 5V | 5V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 36 A | 36 A | 10 A | ||||
![]() |
NMP1K2-HEEC##-02 | 615.6600 | ![]() |
7862 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 900W | 3 | 88.5% | 24V | 12V | 5V | - | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 40 A | 36 A | |||||
![]() |
NMP1K2-KKE#EK-01 | 733.5900 | ![]() |
6197 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 4 | 88.5% | 48V | 12V | 12V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 20 A | 5 A | ||||
![]() |
NMP1K2-HH#HHH-05 | 698.9800 | ![]() |
4931 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 4 | 88.5% | 24V | 24V | 24V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 10 A | 20 A | ||||
![]() |
NMP1K2-HKK#KC-02 | 733.5900 | ![]() |
5906 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 4 | 88.5% | 24V | 48V | 48V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 5 A | 36 A | ||||
![]() |
NMP1K2-#HCEEE-05 | 733.5900 | ![]() |
6706 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 4 | 88.5% | 24V | 5V | 12V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 36 A | 20 A | 40 A | ||||
![]() |
RPT-60C | 22.7400 | ![]() |
81 | 0.00000000 | MEAN WELL USA Inc. | RPT-60 (60W) | Box | Active | -20°C ~ 65°C (With Derating) | ITE (Commercial), Medical | 4.00" L x 2.00" W x 1.14" H (101.6mm x 50.8mm x 29.0mm) | Chassis Mount | Open Frame | Adjustable Output, Universal Input | RPT-60 | CB, CE, cURus, TUV | 90 ~ 264 VAC, 127 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9510 | 96 | 50W | 3 | 79% | 5V | 15V | -15V | - | - | Yes | 4 kV | 4 A | 1.5 A | 500 mA | ||||||
![]() |
NMP1K2-HE##CK-00 | 641.2200 | ![]() |
4310 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 900W | 4 | 88.5% | 24V | 12V | 5V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 36 A | 5 A | ||||
![]() |
NMP1K2-###HCC-00 | 553.7800 | ![]() |
1626 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 600W | 3 | 88.5% | 24V | 5V | 5V | - | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 36 A | 36 A | |||||
![]() |
NMP650-CH##-00 | 398.2100 | ![]() |
3448 | 0.00000000 | MEAN WELL USA Inc. | NMP (650W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 3.50" W x 1.61" H (250.0mm x 89.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP650 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 420W | 2 | 88.5% | 5V | 24V | - | - | - | - | 4 kV | 60601-1; 62368-1 | 36 A | 10 A | ||||||
![]() |
NMP650-HHHE-02 | 565.9600 | ![]() |
2435 | 0.00000000 | MEAN WELL USA Inc. | NMP (650W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 3.50" W x 1.61" H (250.0mm x 89.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP650 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 650W | 3 | 88.5% | 24V | 24V | 12V | - | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 20 A | |||||
![]() |
NMP1K2-C#HCHK-00 | 728.6700 | ![]() |
8978 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 5V | 24V | 5V | 24V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 36 A | 10 A | 36 A | 10 A | 5 A | ||
![]() |
NMP1K2-KKKCC#-02 | 733.5900 | ![]() |
8657 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 4 | 88.5% | 48V | 48V | 5V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 5 A | 10 A | 36 A | 36 A | ||||
![]() |
NMP1K2-K#HHHC-08 | 735.9300 | ![]() |
4758 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 3 | 88.5% | 48V | 24V | 5V | - | - | - | 4 kV | 60601-1; 62368-1 | 5 A | 30 A | 36 A |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse