Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 | Current - Output 3 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
RAC60-24S/OF | - | ![]() |
5806 | 0.00000000 | Recom Power | POWERLINE RAC60 (60W) | Box | Obsolete | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.18" H (101.6mm x 50.8mm x 30.0mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | CB, CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 30 | 60W | 1 | 85% | 24V | - | - | - | - | - | 3 kV | 2.5 A | |||||||
![]() |
RAC40-3.3SA-ST | - | ![]() |
2044 | 0.00000000 | Recom Power | POWERLINE RAC40-A (40W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Medical | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 2 | 40W | 1 | 76% | 3.3V | - | - | - | - | - | 4 kV | 8 A | |||||||
![]() |
RAC15-15DB-ST | - | ![]() |
6134 | 0.00000000 | Recom Power | POWERLINE RAC15-B (15W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.14" H (96.0mm x 53.9mm x 29.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 15W | 2 | 82% | 15V | -15V | - | - | - | - | 4 kV | 500 mA | 500 mA | ||||||
![]() |
RAC40-05SA-ST | - | ![]() |
8337 | 0.00000000 | Recom Power | POWERLINE RAC40-A (40W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Medical | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 2 | 40W | 1 | 79% | 5V | - | - | - | - | - | 4 kV | 8 A | |||||||
RAC06-05SC/W | 21.5700 | ![]() |
30 | 0.00000000 | Recom Power | POWERLINE RAC06-C (6W) | Bag | Obsolete | -25°C ~ 75°C (With Derating) | ITE (Commercial) | 2.11" L x 1.09" W x 0.62" H (53.5mm x 27.8mm x 15.7mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 80 ~ 264 VAC, 115 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9580 | 20 | 6W | 1 | 75% | 5V | - | - | - | - | Yes | 3 kV | 1.2 A | ||||||||
![]() |
RAC15-12SB-ST | - | ![]() |
9217 | 0.00000000 | Recom Power | POWERLINE RAC15-B (15W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.14" H (96.0mm x 53.9mm x 29.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 5 | 15W | 1 | 81% | 12V | - | - | - | - | - | 4 kV | 1.25 A | |||||||
![]() |
RACM550-56SG/ENC | 153.5900 | ![]() |
8923 | 0.00000000 | Recom Power | POWERLINE RACM550-G (550W) | Box | Active | -40°C ~ 70°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 5.91" L x 3.43" W x 1.77" H (150.0mm x 87.0mm x 45.0mm) | Chassis Mount | Enclosed | Adjustable Output, Baseplate, Remote On/Off, Remote Sense, Universal Input | RACM550-56 | CE, cURus | 80 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 550W | 1 | 94% | 56V | - | - | - | - | - | - | 4 kV | 9.82 A | |||||
![]() |
RAC10-05SA-ST | - | ![]() |
2566 | 0.00000000 | Recom Power | POWERLINE RAC10-A (10W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.06" H (96.0mm x 53.9mm x 27.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 10W | 1 | 71% | 5V | - | - | - | - | - | 3 kV | 2 A | |||||||
![]() |
RAC10-15DA-E-ST | - | ![]() |
6569 | 0.00000000 | Recom Power | POWERLINE RAC10-A (10W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.06" H (96.0mm x 53.9mm x 27.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 10W | 2 | 72% | 15V | -15V | - | - | - | - | 3 kV | 300 mA | 300 mA | ||||||
![]() |
RACM65-48S | 109.9600 | ![]() |
4566 | 0.00000000 | Recom Power | MEDLINE RACM65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.38" W x 1.31" H (91.4mm x 60.5mm x 33.3mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | RACM65-48 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000242 | EAR99 | 8504.40.6007 | 1 | 65W | 1 | 93% | 48V | - | - | - | - | No | 4 kV | 1.36 A | |||||
RAC05-09SC/W | - | ![]() |
9345 | 0.00000000 | Recom Power | POWERLINE RAC05-C (5W) | Bulk | Obsolete | -25°C ~ 75°C (With Derating) | ITE (Commercial) | 2.00" L x 1.00" W x 0.62" H (50.8mm x 25.4mm x 15.7mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 20000938 | EAR99 | 8504.40.6001 | 20 | 5W | 1 | 75% | 9V | - | - | - | - | No | 3 kV | 556 mA | |||||||
RAC05-05SC/W | - | ![]() |
6363 | 0.00000000 | Recom Power | POWERLINE RAC05-C (5W) | Bulk | Obsolete | -25°C ~ 75°C (With Derating) | ITE (Commercial) | 2.00" L x 1.00" W x 0.62" H (50.8mm x 25.4mm x 15.7mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 20000937 | EAR99 | 8504.40.6001 | 20 | 5W | 1 | 73% | 5V | - | - | - | - | No | 3 kV | 1 A | |||||||
![]() |
RACM40-12SK/OF-CTN | 16.9458 | ![]() |
6944 | 0.00000000 | Recom Power | POWERLINE RACM40-K/OF (40W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.08" L x 1.60" W x 1.00" H (78.3mm x 40.6mm x 25.5mm) | Chassis Mount | Open Frame | Standby Output, Universal Input | RACM40-12 | CE, cURus, CSA | 80 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6001 | 64 | 40W | 1 | 90% | 12V | - | - | - | - | - | No | 4 kV | 60601-1 | 3.334 A | ||||
![]() |
RAC20-0512TA-ST | - | ![]() |
2947 | 0.00000000 | Recom Power | POWERLINE RAC20-A (20W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.08" H (111.9mm x 63.7mm x 27.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 20W | 3 | 79% | 5V | 12V | -12V | - | - | - | 3 kV | 3 A | 250 mA | 250 mA | |||||
![]() |
RAC30-15DA-ST | - | ![]() |
7224 | 0.00000000 | Recom Power | POWERLINE RAC30-A (30W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 30W | 2 | 82% | 15V | -15V | - | - | - | - | 3 kV | 1 A | 1 A | ||||||
![]() |
RAC20-09SA-ST | - | ![]() |
6709 | 0.00000000 | Recom Power | POWERLINE RAC20-A (20W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.08" H (111.9mm x 63.7mm x 27.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 20W | 1 | 83% | 9V | - | - | - | - | - | 3 kV | 2.23 A | |||||||
![]() |
RACM40-36SK/OF | 21.6000 | ![]() |
4 | 0.00000000 | Recom Power | POWERLINE RACM40-K/OF (40W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.08" L x 1.60" W x 1.00" H (78.3mm x 40.6mm x 25.5mm) | Chassis Mount | Open Frame | Standby Output, Universal Input | RACM40-36 | CE, cURus, CSA | 80 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6001 | 1 | 40W | 1 | 90% | 36V | - | - | - | - | - | No | 4 kV | 60601-1 | 1.111 A | ||||
![]() |
RAC04-09SC/W | - | ![]() |
6516 | 0.00000000 | Recom Power | POWERLINE RAC04-SC/W (4W) | Box | Obsolete | -25°C ~ 85°C (With Derating) | ITE (Commercial) | 1.49" L x 0.94" W x 0.65" H (37.8mm x 23.9mm x 16.4mm) | Chassis Mount | Enclosed | DC Input Capable, Remote Sense, Universal Input | CB, CE, cURus | 80 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6001 | 30 | 4W | 1 | 76% | 9V | - | - | - | - | No | 3 kV | 444 mA | |||||||
![]() |
RAC60-05S/OF | - | ![]() |
2169 | 0.00000000 | Recom Power | POWERLINE RAC60 (60W) | Box | Obsolete | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.18" H (101.6mm x 50.8mm x 30.0mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | CB, CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6001 | 30 | 60W | 1 | 80% | 5V | - | - | - | - | - | 3 kV | 10 A | |||||||
![]() |
RAC03-05SC/277/W | - | ![]() |
3839 | 0.00000000 | Recom Power | POWERLINE RAC03-SC/277/W (3W) | Box | Obsolete | -25°C ~ 85°C (With Derating) | ITE (Commercial) | 1.51" L x 0.96" W x 0.69" H (38.3mm x 24.4mm x 17.4mm) | Chassis Mount | Enclosed | DC Input Capable, Remote Sense, Universal Input | CB, CE, cURus | 80 ~ 305 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6001 | 30 | 3W | 1 | 76% | 5V | - | - | - | - | No | 3 kV | 600 mA | |||||||
![]() |
RAC03-24SE/277/W | 22.5800 | ![]() |
8691 | 0.00000000 | Recom Power | POWERLINE RAC03-E/277/W (3W) | Box | Not For New Designs | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial) | 1.50" L x 0.96" W x 0.69" H (38.1mm x 24.3mm x 17.4mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | RAC03-24 | CE, cURus | 85 ~ 305 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 30 | 3W | 1 | 80% | 24V | - | - | - | - | Yes | 3 kV | 125 mA | ||||||
![]() |
RAC03-3.3SC/277/W | - | ![]() |
3178 | 0.00000000 | Recom Power | POWERLINE RAC03-SC/277/W (3W) | Box | Obsolete | -25°C ~ 85°C (With Derating) | ITE (Commercial) | 1.51" L x 0.96" W x 0.69" H (38.3mm x 24.4mm x 17.4mm) | Chassis Mount | Enclosed | DC Input Capable, Remote Sense, Universal Input | CB, CE, cURus | 80 ~ 305 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 30 | 3W | 1 | 71% | 3.3V | - | - | - | - | No | 3 kV | 900 mA | |||||||
![]() |
RAC03-24SER/277 | 28.7400 | ![]() |
2074 | 0.00000000 | Recom Power | POWERLINE RAC03-SER/277 (3W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial) | 1.98" L x 1.98" W x 0.43" H (50.3mm x 50.3mm x 11.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | RAC03-24 | CE, cURus | 85 ~ 305 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 12 | 3W | 1 | 76% | 24V | - | - | - | - | Yes | 3 kV | 125 mA | ||||||
RACM130E-24SK/ENC | 38.6000 | ![]() |
4 | 0.00000000 | Recom Power | RACM130E-K (130W) | Tray | Active | -40°C ~ 90°C (With Derating) | ITE (Commercial) | 4.66" L x 2.47" W x 1.52" H (118.3mm x 62.7mm x 38.7mm) | Chassis Mount | Enclosed | Baseplate, DC Input Capable, PFC, Universal Input | CE, EAC | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9520 | 18 | 130W | 1 | 88% | 24V | - | - | - | - | - | No | 4 kV | - | 5.42 A | ||||||
![]() |
RACM1200-36SAV/ENC | 429.3900 | ![]() |
1 | 0.00000000 | Recom Power | RACM1200-V (1200W) | Box | Active | -40°C ~ 80°C (With Derating) | ITE (Commercial), Laboratory | 8.98" L x 3.79" W x 1.57" H (228.0mm x 96.2mm x 40.0mm) | Chassis Mount | Enclosed | Adjustable Output, Baseplate, PFC, Remote On/Off, Remote Sense, Standby Output | CE, cURus, EAC | 80 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Affected | EAR99 | 8504.40.9540 | 1 | 1440W | 1 | 95% | 36V | - | - | - | - | - | No | 4 kV | 61010-1; 62368-1 | 40 A | |||||
![]() |
RAC15-15SA-ST | - | ![]() |
1338 | 0.00000000 | Recom Power | POWERLINE RAC15-A (15W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.09" H (111.9mm x 63.7mm x 27.6mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 15W | 1 | 73% | 15V | - | - | - | - | - | 3 kV | 1 A | |||||||
RACM40-15S | 99.6900 | ![]() |
2 | 0.00000000 | Recom Power | MEDLINE RACM40 (40W) | Box | Not For New Designs | -40°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.38" W x 1.31" H (91.4mm x 60.5mm x 33.3mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | RACM40-15 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6001 | 1 | 40W | 1 | 92% | 15V | - | - | - | - | No | 4 kV | 2.67 A | |||||||
![]() |
RAC15-12SB-E-ST | - | ![]() |
1083 | 0.00000000 | Recom Power | POWERLINE RAC15-B (15W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.14" H (96.0mm x 53.9mm x 29.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 5 | 15W | 1 | 81% | 12V | - | - | - | - | - | 4 kV | 1.25 A | |||||||
![]() |
RACM150-15S | 153.1320 | ![]() |
8741 | 0.00000000 | Recom Power | MEDLINE RACM150 (150W) | Box | Not For New Designs | -25°C ~ 80°C (With Derating) | Medical | 4.60" L x 2.44" W x 1.94" H (116.8mm x 62.0mm x 49.2mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, PFC, Universal Input | RACM150 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 10 | 150W | 1 | 92% | 15V | - | - | - | - | No | 4 kV | 9 A | ||||||
![]() |
RAC30-15SA-E-ST | - | ![]() |
1841 | 0.00000000 | Recom Power | POWERLINE RAC30-A (30W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 30W | 1 | 82% | 15V | - | - | - | - | - | 3 kV | 2 A |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse