Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
RAC05-3.3SC/W | - | ![]() |
4323 | 0.00000000 | Recom Power | POWERLINE RAC05-C (5W) | Bulk | Obsolete | -25°C ~ 75°C (With Derating) | ITE (Commercial) | 2.00" L x 1.00" W x 0.62" H (50.8mm x 25.4mm x 15.7mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 20000936 | EAR99 | 8504.40.6018 | 20 | 5W | 1 | 70% | 3.3V | - | - | - | - | No | 3 kV | 1.25 A | |||||
![]() |
RAC10-12SB-ST | - | ![]() |
9916 | 0.00000000 | Recom Power | POWERLINE RAC10-B (10W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.15" H (96.0mm x 53.9mm x 29.1mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 10W | 1 | 82% | 12V | - | - | - | - | - | 3 kV | 833 mA | ||||||
![]() |
RAC02-3.3SE/277/W | 20.3800 | ![]() |
489 | 0.00000000 | Recom Power | POWERLINE RAC02-SE/277/W (2W) | Box | Not For New Designs | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial) | 1.33" L x 0.96" W x 0.70" H (33.7mm x 24.4mm x 17.8mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | RAC02-3.3 | CE, cURus | 85 ~ 305 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 30 | 2W | 1 | 67% | 3.3V | - | - | - | - | Yes | 3 kV | 600 mA | |||||
![]() |
RAC04-3.3SC/W | 15.6400 | ![]() |
6 | 0.00000000 | Recom Power | POWERLINE RAC04-SC/W (4W) | Box | Obsolete | -25°C ~ 85°C (With Derating) | ITE (Commercial) | 1.49" L x 0.94" W x 0.65" H (37.8mm x 23.9mm x 16.4mm) | Chassis Mount | Enclosed | DC Input Capable, Remote Sense, Universal Input | CB, CE, cURus | 80 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 30 | 4W | 1 | 67% | 3.3V | - | - | - | - | No | 3 kV | 1.2 A | ||||||
![]() |
RACM65-05S/OF | 106.6400 | ![]() |
6796 | 0.00000000 | Recom Power | MEDLINE RACM65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.00" L x 2.00" W x 1.04" H (76.2mm x 50.8mm x 26.5mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | RACM65-05 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000261 | EAR99 | 8504.40.6007 | 1 | 65W | 1 | 90% | 5V | - | - | - | - | No | 4 kV | 10 A | ||||
![]() |
RAC60-15S/OF | - | ![]() |
4010 | 0.00000000 | Recom Power | POWERLINE RAC60 (60W) | Box | Obsolete | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.18" H (101.6mm x 50.8mm x 30.0mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | CB, CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 30 | 60W | 1 | 84% | 15V | - | - | - | - | - | 3 kV | 4 A | ||||||
![]() |
RAC03-05SER/277 | 28.2100 | ![]() |
8326 | 0.00000000 | Recom Power | POWERLINE RAC03-SER/277 (3W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial) | 1.98" L x 1.98" W x 0.43" H (50.3mm x 50.3mm x 11.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | RAC03-05 | CE, cURus | 85 ~ 305 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6001 | 12 | 3W | 1 | 70% | 5V | - | - | - | - | Yes | 3 kV | 600 mA | |||||
![]() |
RAC48-12S/OF | - | ![]() |
9507 | 0.00000000 | Recom Power | POWERLINE RAC48/OF (48W) | Box | Obsolete | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.18" H (101.6mm x 50.8mm x 30.0mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | CB, CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 30 | 48W | 1 | 82% | 12V | - | - | - | - | - | 3 kV | 4 A | ||||||
RAC05-12SC/W | 19.4500 | ![]() |
4 | 0.00000000 | Recom Power | POWERLINE RAC05-C (5W) | Bulk | Obsolete | -25°C ~ 75°C (With Derating) | ITE (Commercial) | 2.00" L x 1.00" W x 0.62" H (50.8mm x 25.4mm x 15.7mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 20 | 5W | 1 | 76% | 12V | - | - | - | - | No | 3 kV | 420 mA | |||||||
![]() |
RAC10-24SB-ST | - | ![]() |
2239 | 0.00000000 | Recom Power | POWERLINE RAC10-B (10W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.15" H (96.0mm x 53.9mm x 29.1mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 10W | 1 | 80% | 24V | - | - | - | - | - | 3 kV | 417 mA | ||||||
![]() |
RAC03-3.3SE/277/W | 23.5400 | ![]() |
18 | 0.00000000 | Recom Power | POWERLINE RAC03-E/277/W (3W) | Box | Not For New Designs | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial) | 1.50" L x 0.96" W x 0.69" H (38.1mm x 24.3mm x 17.4mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | RAC03-3.3 | CE, cURus | 85 ~ 305 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 30 | 3W | 1 | 71% | 3.3V | - | - | - | - | Yes | 3 kV | 900 mA | |||||
![]() |
RAC30-24SA-E-ST | - | ![]() |
6530 | 0.00000000 | Recom Power | POWERLINE RAC30-A (30W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 30W | 1 | 82% | 24V | - | - | - | - | - | 3 kV | 1.25 A | ||||||
![]() |
RACM150-15S/F | 193.4600 | ![]() |
8 | 0.00000000 | Recom Power | MEDLINE RACM150 (150W) | Box | Obsolete | -25°C ~ 80°C (With Derating) | Medical | 4.60" L x 2.44" W x 1.94" H (116.8mm x 62.0mm x 49.2mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, PFC, Universal Input | RACM150 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 10 | 150W | 1 | 92% | 15V | - | - | - | - | No | 4 kV | 10 A | |||||
![]() |
RAC05-15SC/W | 20.3300 | ![]() |
16 | 0.00000000 | Recom Power | POWERLINE RAC05-C (5W) | Bulk | Obsolete | -25°C ~ 75°C (With Derating) | ITE (Commercial) | 2.00" L x 1.00" W x 0.62" H (50.8mm x 25.4mm x 15.7mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 20 | 5W | 1 | 76% | 15V | - | - | - | - | No | 3 kV | 340 mA | ||||||
![]() |
RAC40-15DA-E-ST | - | ![]() |
4635 | 0.00000000 | Recom Power | POWERLINE RAC40-A (40W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | Medical | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 2 | 40W | 2 | 83% | 15V | -15V | - | - | - | - | 4 kV | 1.32 A | 1.32 A | |||||
![]() |
RAC10-15SB-E-ST | - | ![]() |
3755 | 0.00000000 | Recom Power | POWERLINE RAC10-B (10W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.15" H (96.0mm x 53.9mm x 29.1mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 10W | 1 | 78% | 15V | - | - | - | - | - | 3 kV | 667 mA | ||||||
![]() |
RAC10-12DA-ST | - | ![]() |
1049 | 0.00000000 | Recom Power | POWERLINE RAC10-A (10W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.06" H (96.0mm x 53.9mm x 27.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 10W | 2 | 75% | 12V | -12V | - | - | - | - | 3 kV | 380 mA | 380 mA | |||||
![]() |
RAC20-12DA-ST | - | ![]() |
8114 | 0.00000000 | Recom Power | POWERLINE RAC20-A (20W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.08" H (111.9mm x 63.7mm x 27.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 20W | 2 | 82% | 12V | -12V | - | - | - | - | 3 kV | 833 mA | 833 mA | |||||
![]() |
RAC40-05DA-E-ST | - | ![]() |
7479 | 0.00000000 | Recom Power | POWERLINE RAC40-A (40W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | Medical | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 2 | 40W | 2 | 80% | 5V | -5V | - | - | - | - | 4 kV | 4 A | 4 A | |||||
![]() |
RACM40-12SK/OF/2X3 | 23.4300 | ![]() |
15 | 0.00000000 | Recom Power | POWERLINE RACM40-K/OF (40W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.08" L x 2.09" W x 1.00" H (78.3mm x 53.0mm x 25.5mm) | Chassis Mount | Open Frame | Standby Output, Universal Input | RACM40-12 | CE, cURus, CSA | 80 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6001 | 1 | 40W | 1 | 90% | 12V | - | - | - | - | - | No | 4 kV | 60601-1 | 3.334 A | |||
![]() |
RAC40-12SA-E-ST | - | ![]() |
9153 | 0.00000000 | Recom Power | POWERLINE RAC40-A (40W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | Medical | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 2 | 40W | 1 | 83% | 12V | - | - | - | - | - | 4 kV | 3.33 A | ||||||
![]() |
RAC10-12SA-E-ST | - | ![]() |
2948 | 0.00000000 | Recom Power | POWERLINE RAC10-A (10W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.06" H (96.0mm x 53.9mm x 27.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 10W | 1 | 74% | 12V | - | - | - | - | - | 3 kV | 833 mA | ||||||
RAC05-24SC/W | - | ![]() |
4740 | 0.00000000 | Recom Power | POWERLINE RAC05-C (5W) | Bulk | Obsolete | -25°C ~ 75°C (With Derating) | ITE (Commercial) | 2.00" L x 1.00" W x 0.62" H (50.8mm x 25.4mm x 15.7mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 20 | 5W | 1 | 77% | 24V | - | - | - | - | No | 3 kV | 210 mA | |||||||
![]() |
RAC40-12DA-E-ST | - | ![]() |
2306 | 0.00000000 | Recom Power | POWERLINE RAC40-A (40W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | Medical | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 2 | 40W | 2 | 83% | 12V | -12V | - | - | - | - | 4 kV | 1.67 A | 1.67 A | |||||
![]() |
RACM65-15S | 115.4800 | ![]() |
6538 | 0.00000000 | Recom Power | MEDLINE RACM65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.38" W x 1.31" H (91.4mm x 60.5mm x 33.3mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | RACM65-15 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000240 | EAR99 | 8504.40.6007 | 1 | 65W | 1 | 93.5% | 15V | - | - | - | - | No | 4 kV | 4.33 A | ||||
![]() |
RACM40-15SK/OF/2X3 | 19.1733 | ![]() |
9656 | 0.00000000 | Recom Power | POWERLINE RACM40-K/OF (40W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.08" L x 2.09" W x 1.00" H (78.3mm x 53.0mm x 25.5mm) | Chassis Mount | Open Frame | Standby Output, Universal Input | RACM40-15 | CE, cURus, CSA | 80 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6001 | 1 | 40W | 1 | 90% | 15V | - | - | - | - | - | No | 4 kV | 60601-1 | 2.667 A | |||
![]() |
RACM40-24SK/OF-CTN | 17.3828 | ![]() |
3076 | 0.00000000 | Recom Power | POWERLINE RACM40-K/OF (40W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.08" L x 1.60" W x 1.00" H (78.3mm x 40.6mm x 25.5mm) | Chassis Mount | Open Frame | Standby Output, Universal Input | RACM40-24 | CE, cURus, CSA | 80 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6001 | 64 | 40W | 1 | 90% | 24V | - | - | - | - | - | No | 4 kV | 60601-1 | 1.667 A | |||
![]() |
RACM40-18SK/OF | 22.1500 | ![]() |
14 | 0.00000000 | Recom Power | POWERLINE RACM40-K/OF (40W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.08" L x 1.60" W x 1.00" H (78.3mm x 40.6mm x 25.5mm) | Chassis Mount | Open Frame | Standby Output, Universal Input | RACM40-18 | CE, cURus, CSA | 80 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6001 | 1 | 40W | 1 | 90% | 18V | - | - | - | - | - | No | 4 kV | 60601-1 | 2.222 A | |||
![]() |
RAC10-05DA-ST | - | ![]() |
5193 | 0.00000000 | Recom Power | POWERLINE RAC10-A (10W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.06" H (96.0mm x 53.9mm x 27.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 10W | 2 | 73% | 5V | -5V | - | - | - | - | 3 kV | 800 mA | 800 mA | |||||
![]() |
RAC10-12SB-E-ST | - | ![]() |
1080 | 0.00000000 | Recom Power | POWERLINE RAC10-B (10W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.15" H (96.0mm x 53.9mm x 29.1mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 10W | 1 | 82% | 12V | - | - | - | - | - | 3 kV | 833 mA |