SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4
ABC275-1058L Bel Power Solutions ABC275-1058L -
RFQ
ECAD 1827 0.00000000 Bel Power Solutions ABC275 (275W) Box Not For New Designs -40°C ~ 70°C (With Derating) ITE (Commercial) 5.00" L x 3.00" W x 0.75" H (127.0mm x 76.2mm x 19.0mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Standby Output, Universal Input ABC275 CE 80 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 179-2954 EAR99 8504.40.6012 18 160W (275W Forced Air) 1 92% 58V - - - - No 3 kV 2.76 A
ABC275-1T12L Bel Power Solutions ABC275-1T12L 130.9700
RFQ
ECAD 2 0.00000000 Bel Power Solutions ABC275 (275W) Box Not For New Designs -40°C ~ 70°C (With Derating) ITE (Commercial) 5.00" L x 3.00" W x 0.75" H (127.0mm x 76.2mm x 19.0mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Standby Output, Universal Input ABC275 CE 80 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6012 18 160W (275W Forced Air) 1 88% 12V - - - - No 3 kV 13.33 A
MBC180-1024L Bel Power Solutions MBC180-1024L 121.7800
RFQ
ECAD 24 0.00000000 Bel Power Solutions MBC180 (180W) Box Not For New Designs -40°C ~ 70°C (With Derating) Medical 4.00" L x 2.00" W x 0.75" H (101.6mm x 50.8mm x 19.1mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Standby Output, Universal Input MBC180 CE 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6012 24 120W (180W Forced Air) 1 90% 24V - - - - No 4 kV 5 A
MBC180-1048L Bel Power Solutions MBC180-1048L 121.7800
RFQ
ECAD 5 0.00000000 Bel Power Solutions MBC180 (180W) Box Not For New Designs -40°C ~ 70°C (With Derating) Medical 4.00" L x 2.00" W x 0.75" H (101.6mm x 50.8mm x 19.1mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Standby Output, Universal Input MBC180 CE 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6012 24 120W (180W Forced Air) 1 92% 48V - - - - No 4 kV 2.5 A
MBC275-1024L Bel Power Solutions MBC275-1024L -
RFQ
ECAD 4264 0.00000000 Bel Power Solutions MBC275 (275W) Box Not For New Designs -40°C ~ 70°C (With Derating) Medical 5.00" L x 3.00" W x 0.75" H (127.0mm x 76.2mm x 19.0mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Standby Output, Universal Input MBC275 CE 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 179-2967 EAR99 8504.40.6012 18 160W (275W Forced Air) 1 90% 24V - - - - No 4 kV 6.67 A
MBC275-1T12L Bel Power Solutions MBC275-1T12L 144.1000
RFQ
ECAD 3 0.00000000 Bel Power Solutions MBC275 (275W) Box Not For New Designs -40°C ~ 70°C (With Derating) Medical 5.00" L x 3.00" W x 0.75" H (127.0mm x 76.2mm x 19.0mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Standby Output, Universal Input MBC275 CE 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6012 18 160W (275W Forced Air) 1 88% 12V - - - - No 4 kV 13.33 A
MBC275-1T24L Bel Power Solutions MBC275-1T24L 144.1000
RFQ
ECAD 15 0.00000000 Bel Power Solutions MBC275 (275W) Box Not For New Designs -40°C ~ 70°C (With Derating) Medical 5.00" L x 3.00" W x 0.75" H (127.0mm x 76.2mm x 19.0mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Standby Output, Universal Input MBC275 CE 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6012 18 160W (275W Forced Air) 1 90% 24V - - - - No 4 kV 6.67 A
ABC120-1012L Bel Power Solutions ABC120-1012L -
RFQ
ECAD 6142 0.00000000 Bel Power Solutions ABC120 (120W) Bulk Not For New Designs -40°C ~ 70°C (With Derating) ITE (Commercial) 3.00" L x 2.00" W x 1.18" H (76.2mm x 50.8mm x 30.1mm) Chassis Mount Open Frame Adjustable Output, PFC, Standby Output, Universal Input ABC120 CE, CCC, cUL, UL, NEMKO 85 ~ 264 VAC download ROHS3 Compliant Not Applicable REACH Unaffected 2266-ABC120-1012L EAR99 8504.40.9520 42 100W (120W Forced Air) 1 90% 12V - - - - - 3 kV 8.33 A
MBC120-1012L-2 Bel Power Solutions MBC120-1012L-2 -
RFQ
ECAD 9732 0.00000000 Bel Power Solutions MBC120 (120W) Bulk Active -40°C ~ 70°C (With Derating) Medical 3.00" L x 2.00" W x 1.18" H (76.2mm x 50.8mm x 30.1mm) Chassis Mount Open Frame Adjustable Output, PFC, Standby Output, Universal Input MBC120 CB, CE, cULus, NEMKO 85 ~ 264 VAC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9520 42 100W (120W Forced Air) 1 90% 12V - - - - - 4 kV 8.33 A
MBC350-1T15L Bel Power Solutions MBC350-1T15L -
RFQ
ECAD 9127 0.00000000 Bel Power Solutions MBC350 (350W) Bulk Not For New Designs -40°C ~ 70°C (With Derating) Medical 5.00" L x 3.00" W x 1.00" H (127.0mm x 76.2mm x 25.4mm) Chassis Mount Open Frame Adjustable Output, PFC, Standby Output, Universal Input MBC350 CE, cUL, UL, NEMKO 90 ~ 264 VAC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9530 18 180W (350W Forced Air) 1 92% 15V - - - - - 4 kV 12 A
TET2500-12-086NA Bel Power Solutions TET2500-12-086NA 855.4700
RFQ
ECAD 4321 0.00000000 Bel Power Solutions TET2500 (2500W) Bulk Active 0°C ~ 45°C ITE (Commercial) 7.68" L x 3.39" W x 1.57" H (195.0mm x 86.0mm x 40.0mm) Rack Mount Front End Adjustable Output, PFC, Standby Output TET2500 CE 90 ~ 264 VAC, 180 ~ 300 VDC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 179-3069 EAR99 8504.40.9540 5 2436W 1 - 12V - - - - - 4.3 kV 203 A
ACC600-1T24 Bel Power Solutions ACC600-1T24 271.4900
RFQ
ECAD 15 0.00000000 Bel Power Solutions ACC600 (600W) Bulk Not For New Designs -40°C ~ 70°C (With Derating) ITE (Commercial) 8.50" L x 5.00" W x 1.61" H (216.0mm x 127.0mm x 41.0mm) Chassis Mount Open Frame Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input ACC600 CE, NEMKO 85 ~ 264 VAC, 120 ~ 390 VDC - ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9540 16 600W 1 93% 24V - - - - - No 4 kV 25 A
ACC600-1T48 Bel Power Solutions ACC600-1T48 271.4900
RFQ
ECAD 15 0.00000000 Bel Power Solutions ACC600 (600W) Bulk Not For New Designs -40°C ~ 70°C (With Derating) ITE (Commercial) 8.50" L x 5.00" W x 1.61" H (216.0mm x 127.0mm x 41.0mm) Chassis Mount Open Frame Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input ACC600 CE, NEMKO 85 ~ 264 VAC, 120 ~ 390 VDC - ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9540 16 600W 1 93% 48V - - - - - No 4 kV 12.5 A
MCC600-1T12 Bel Power Solutions MCC600-1T12 302.1900
RFQ
ECAD 16 0.00000000 Bel Power Solutions MCC600 (600W) Bulk Not For New Designs -40°C ~ 70°C (With Derating) Medical 8.50" L x 5.00" W x 1.61" H (216.0mm x 127.0mm x 41.0mm) Chassis Mount Open Frame Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input MCC600 CE, NEMKO 85 ~ 264 VAC, 120 ~ 390 VDC - ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9540 16 300W 1 93% 12V - - - - - No 4.245 kV 25 A
MCC600-1T24 Bel Power Solutions MCC600-1T24 302.1900
RFQ
ECAD 21 0.00000000 Bel Power Solutions MCC600 (600W) Bulk Not For New Designs -40°C ~ 70°C (With Derating) Medical 8.50" L x 5.00" W x 1.61" H (216.0mm x 127.0mm x 41.0mm) Chassis Mount Open Frame Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input MCC600 CE, NEMKO 85 ~ 264 VAC, 120 ~ 390 VDC - ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9540 16 600W 1 93% 24V - - - - - No 4.245 kV 25 A
ABC800-1T24 Bel Power Solutions ABC800-1T24 -
RFQ
ECAD 1684 0.00000000 Bel Power Solutions ABC800 (800W) Box Not For New Designs -40°C ~ 70°C (With Derating) ITE (Commercial) 8.50" L x 5.00" W x 1.61" H (216.0mm x 127.0mm x 41.0mm) Chassis Mount Open Frame Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input ABC800 CE, cUL, Nemko, UL 85 ~ 264 VAC, 120 ~ 390 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 600W (800W Forced Air) 1 93% 24V - - - - - No 4 kV 25 A
MBC800-1T24 Bel Power Solutions MBC800-1T24 317.7100
RFQ
ECAD 1 0.00000000 Bel Power Solutions MBC800 (800W) Box Not For New Designs -40°C ~ 70°C (With Derating) Medical 8.50" L x 5.00" W x 1.61" H (216.0mm x 127.0mm x 41.0mm) Chassis Mount Open Frame Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input MBC800 CE, cUL, Nemko, UL 85 ~ 264 VAC, 120 ~ 390 VDC - ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 600W (800W Forced Air) 1 93% 24V - - - - - No 4.245 kV 25 A
MPU150-4000M Bel Power Solutions MPU150-4000M -
RFQ
ECAD 9604 0.00000000 Bel Power Solutions MPU150 (150W) Bulk Obsolete 0°C ~ 70°C (With Derating) ITE (Commercial) 8.00" L x 4.20" W x 1.50" H (203.2mm x 106.7mm x 38.1mm) Chassis Mount Open Frame Adjustable Output, Load Sharing, PFC, Remote Sense, Universal Input - 85 ~ 264 VAC - ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9520 250 150W 4 75% 5V 12V 12V 5V - - Yes 2.6 kV 30 A 8 A 3 A 2 A
MPU150-4350M Bel Power Solutions MPU150-4350M -
RFQ
ECAD 1450 0.00000000 Bel Power Solutions MPU150 (150W) Bulk Obsolete 0°C ~ 70°C (With Derating) ITE (Commercial) 8.00" L x 4.20" W x 1.50" H (203.2mm x 106.7mm x 38.1mm) Chassis Mount Open Frame Adjustable Output, Load Sharing, PFC, Remote Sense, Universal Input - 85 ~ 264 VAC - ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9520 250 150W 4 75% 3.3V 5V 12V 12V - - Yes 2.6 kV 30 A 15 A 3 A 3 A
FXP1500-32S202G Bel Power Solutions FXP1500-32S202G -
RFQ
ECAD 2434 0.00000000 Bel Power Solutions FXP1500 (1500W) Bulk Obsolete 0°C ~ 70°C (With Derating) ITE (Commercial) 12.00" L x 5.60" W x 1.60" H (304.8mm x 142.2mm x 40.6mm) Rack Mount Front End Adjustable Output, Hot Swappable, I²C Interface, Load Sharing, PFC, Remote Sense, Standby Output, Universal Input CE 85 ~ 264 VAC - ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1506W 2 89.5% 32V 5V - - - - - 4.2 kV 46.9 A 1 A
TET2200-12-086NA Bel Power Solutions TET2200-12-086NA 793.2500
RFQ
ECAD 4 0.00000000 Bel Power Solutions TET2200 (2200W) Box Active 0°C ~ 55°C ITE (Commercial) 7.74" L x 3.40" W x 1.57" H (196.5mm x 86.3mm x 40.0mm) Rack Mount Front End Adjustable Output, Remote Sense, Standby Output TET2200 CE 100 ~ 240 VAC, 180 ~ 300 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 6 2196W 1 96% 12V - - - - - - 4.242 kV 183 A
TET1500-12-054NA Bel Power Solutions TET1500-12-054NA 709.9300
RFQ
ECAD 15 0.00000000 Bel Power Solutions TET1500 (1500W) Bulk Active -5°C ~ 50°C ITE (Commercial) 12.66" L x 2.15" W x 1.57" H (321.5mm x 54.5mm x 40.0mm) Rack Mount Front End Hot Swappable, I²C Interface, Load Sharing, PFC, Standby Output TET1500 CB, CE 90 ~ 305 VAC, 180 ~ 400 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-TET1500-12-054NA EAR99 8504.40.9540 5 1500W 1 96% 12V - - - - - - 125 A
ABC400-S314G Bel Power Solutions ABC400-S314G -
RFQ
ECAD 9554 0.00000000 Bel Power Solutions ABC400 (400W) Bulk Obsolete -10°C ~ 70°C (With Derating) ITE (Commercial) 5.00" L x 3.00" W x 1.50" H (127.0mm x 76.2mm x 38.1mm) Chassis Mount Open Frame Adjustable Output, PFC, Remote Sense, Universal Input CB, CE 90 ~ 264 VAC - ROHS3 Compliant 1 (Unlimited) 179-ABC400-S314G EAR99 8504.40.9530 1 - - - - - - - - - 4.242 kV 60950-1; 62368-1
FLS250-1058 Bel Power Solutions FLS250-1058 208.6154
RFQ
ECAD 2620 0.00000000 Bel Power Solutions FLS250 (250W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 4.50" L x 2.50" W x 1.57" H (114.3mm x 63.5mm x 39.9mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-FLS250-1058 EAR99 8504.40.9530 24 249W (348W Forced Air) 1 94% 58V - - - - - - 4 kV 62368-1 6 A
FLS250-2315 Bel Power Solutions FLS250-2315 220.3567
RFQ
ECAD 4655 0.00000000 Bel Power Solutions FLS250 (250W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 4.50" L x 2.50" W x 1.57" H (114.3mm x 63.5mm x 39.9mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Remote On/Off, Standby Output, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-FLS250-2315 EAR99 8504.40.9530 24 200W (270W Forced Air) 1 94% 15V - - - - - - 4 kV 62368-1 18 A
MFLS250-1358 Bel Power Solutions MFLS250-1358 231.5679
RFQ
ECAD 2199 0.00000000 Bel Power Solutions FLS250 (250W) Box Active -40°C ~ 70°C (With Derating) Medical 4.50" L x 2.50" W x 1.57" H (114.3mm x 63.5mm x 39.9mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-MFLS250-1358 EAR99 8504.40.9530 24 249W (348W Forced Air) 1 94% 58V - - - - - - 4.38 kV 60601-1 6 A
MFLS250-2315 Bel Power Solutions MFLS250-2315 244.0058
RFQ
ECAD 3286 0.00000000 Bel Power Solutions FLS250 (250W) Box Active -40°C ~ 70°C (With Derating) Medical 4.50" L x 2.50" W x 1.57" H (114.3mm x 63.5mm x 39.9mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Remote On/Off, Standby Output, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-MFLS250-2315 EAR99 8504.40.9530 24 200W (270W Forced Air) 1 94% 15V - - - - - - 4.38 kV 60601-1 18 A
FLS250-2030 Bel Power Solutions FLS250-2030 220.3567
RFQ
ECAD 3337 0.00000000 Bel Power Solutions FLS250 (250W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 4.50" L x 2.50" W x 1.57" H (114.3mm x 63.5mm x 39.9mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Remote On/Off, Standby Output, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-FLS250-2030 EAR99 8504.40.9530 24 249W (348W Forced Air) 1 94% 30V - - - - - - 4 kV 62368-1 11.6 A
FLS250-2058 Bel Power Solutions FLS250-2058 220.3567
RFQ
ECAD 8460 0.00000000 Bel Power Solutions FLS250 (250W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 4.50" L x 2.50" W x 1.57" H (114.3mm x 63.5mm x 39.9mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Remote On/Off, Standby Output, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-FLS250-2058 EAR99 8504.40.9530 24 249W (348W Forced Air) 1 94% 58V - - - - - - 4 kV 62368-1 6 A
MFLS250-2015 Bel Power Solutions MFLS250-2015 244.0058
RFQ
ECAD 4199 0.00000000 Bel Power Solutions FLS250 (250W) Box Active -40°C ~ 70°C (With Derating) Medical 4.50" L x 2.50" W x 1.57" H (114.3mm x 63.5mm x 39.9mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Remote On/Off, Standby Output, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-MFLS250-2015 EAR99 8504.40.9530 24 200W (300W Forced Air) 1 94% 15V - - - - - - 4.38 kV 60601-1 20 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse