SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 6 Minimum Load Required Voltage - Isolation Current - Output 1 Current - Output 2 Current - Output 3
ABC450-1T15G Bel Power Solutions ABC450-1T15G -
RFQ
ECAD 9457 0.00000000 Bel Power Solutions ABC450 (450W) Box Not For New Designs -20°C ~ 70°C (With Derating) ITE (Commercial) 6.50" L x 4.00" W x 1.61" H (165.1mm x 101.6mm x 41.0mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input ABC450 CE 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 12 250W (450W Forced Air) 1 86% 15V - - - - No 4.242 kV 16.6 A
MBC450-1T12G Bel Power Solutions MBC450-1T12G -
RFQ
ECAD 6367 0.00000000 Bel Power Solutions MBC450 (450W) Box Not For New Designs 0°C ~ 70°C (With Derating) Medical 6.50" L x 4.00" W x 1.61" H (165.1mm x 101.6mm x 41.0mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, Remote Sense, Standby Output, Universal Input MBC450 CE 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 12 250W (450W Forced Air) 1 83% 12V - - - - - 4.242 kV 37.5 A
MBC450-1T30G Bel Power Solutions MBC450-1T30G -
RFQ
ECAD 8627 0.00000000 Bel Power Solutions MBC450 (450W) Box Not For New Designs 0°C ~ 70°C (With Derating) Medical 6.50" L x 4.00" W x 1.61" H (165.1mm x 101.6mm x 41.0mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, Remote Sense, Standby Output, Universal Input MBC450 CE 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 12 300W (450W Forced Air) 1 83% 30V - - - - - 4.242 kV 15 A
MBC60-1015G-2 Bel Power Solutions MBC60-1015G-2 -
RFQ
ECAD 8825 0.00000000 Bel Power Solutions MBC60 (60W) Box Active -20°C ~ 70°C (With Derating) Medical 4.00" L x 2.00" W x 1.20" H (101.6mm x 50.8mm x 30.5mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Universal Input MBC60 CE, CSA 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 32 60W 1 85% 15V - - - - No 4.242 kV 4.33 A
MBC60-3001G-2 Bel Power Solutions MBC60-3001G-2 -
RFQ
ECAD 7549 0.00000000 Bel Power Solutions MBC60 (60W) Box Active -20°C ~ 70°C (With Derating) Medical 4.00" L x 2.00" W x 1.20" H (101.6mm x 50.8mm x 30.5mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Universal Input MBC60 CE, CSA 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 32 60W 3 85% 5.2V 24V -12.8V - - Yes 4.242 kV 8 A 1.5 A 500 mA
ABC150-1T15G Bel Power Solutions ABC150-1T15G 80.8300
RFQ
ECAD 72 0.00000000 Bel Power Solutions ABC150 (150W) Box Not For New Designs -20°C ~ 70°C (With Derating) ITE (Commercial) 4.00" L x 2.00" W x 1.32" H (101.6mm x 50.8mm x 33.6mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, Standby Output, Universal Input ABC150 CE 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 24 110W (150W Forced Air) 1 86% 15V - - - - No 4.242 kV 6.67 A
ABC150-1T48G Bel Power Solutions ABC150-1T48G -
RFQ
ECAD 9332 0.00000000 Bel Power Solutions ABC150 (150W) Box Not For New Designs -20°C ~ 70°C (With Derating) ITE (Commercial) 4.00" L x 2.00" W x 1.32" H (101.6mm x 50.8mm x 33.6mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, Standby Output, Universal Input ABC150 CE 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 24 110W (150W Forced Air) 1 86% 48V - - - - No 4.242 kV 2.08 A
MBC150-1T12G Bel Power Solutions MBC150-1T12G -
RFQ
ECAD 8984 0.00000000 Bel Power Solutions MBC150 (150W) Box Not For New Designs -20°C ~ 70°C (With Derating) Medical 4.00" L x 2.00" W x 1.32" H (101.6mm x 50.8mm x 33.6mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, Standby Output, Universal Input MBC150 - 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 24 110W (150W Forced Air) 1 86% 12V - - - - No 5.9 kV 8.33 A
MBC150-1T48G Bel Power Solutions MBC150-1T48G -
RFQ
ECAD 8446 0.00000000 Bel Power Solutions MBC150 (150W) Box Not For New Designs -20°C ~ 70°C (With Derating) Medical 4.00" L x 2.00" W x 1.32" H (101.6mm x 50.8mm x 33.6mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, Standby Output, Universal Input MBC150 - 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 24 110W (150W Forced Air) 1 86% 48V - - - - No 5.9 kV 2.08 A
MBC201-1T12G-2 Bel Power Solutions MBC201-1T12G-2 -
RFQ
ECAD 42 0.00000000 Bel Power Solutions MBC201 (200W) Box Active -20°C ~ 70°C (With Derating) Medical 5.00" L x 3.00" W x 1.50" H (127.0mm x 76.2mm x 38.1mm) Chassis Mount Open Frame Adjustable Output, PFC, Standby Output, Universal Input MBC201 CE 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 21 160W (200W Forced Air) 1 - 12V - - - - No 4.242 kV 13.33 A
MBC201-1T15G-2 Bel Power Solutions MBC201-1T15G-2 -
RFQ
ECAD 9740 0.00000000 Bel Power Solutions MBC201 (200W) Box Active -20°C ~ 70°C (With Derating) Medical 5.00" L x 3.00" W x 1.50" H (127.0mm x 76.2mm x 38.1mm) Chassis Mount Open Frame Adjustable Output, PFC, Standby Output, Universal Input MBC201 CE 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 21 160W (200W Forced Air) 1 - 15V - - - - No 4.242 kV 10.66 A
MBC201-1T24G-2 Bel Power Solutions MBC201-1T24G-2 -
RFQ
ECAD 14 0.00000000 Bel Power Solutions MBC201 (200W) Box Active -20°C ~ 70°C (With Derating) Medical 5.00" L x 3.00" W x 1.50" H (127.0mm x 76.2mm x 38.1mm) Chassis Mount Open Frame Adjustable Output, PFC, Standby Output, Universal Input MBC201 CE 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 21 160W (200W Forced Air) 1 - 24V - - - - No 4.242 kV 6.66 A
MBC201-1T05G-2 Bel Power Solutions MBC201-1T05G-2 -
RFQ
ECAD 3543 0.00000000 Bel Power Solutions MBC201 (200W) Box Active -20°C ~ 70°C (With Derating) Medical 5.00" L x 3.00" W x 1.50" H (127.0mm x 76.2mm x 38.1mm) Chassis Mount Open Frame Adjustable Output, PFC, Standby Output, Universal Input MBC201 CE 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9520 21 160W (200W Forced Air) 1 - 5V - - - - No 4.242 kV 26 A
ABC40-1005G Bel Power Solutions ABC40-1005G 26.7700
RFQ
ECAD 13 0.00000000 Bel Power Solutions ABC40 (40W) Box Not For New Designs -20°C ~ 70°C (With Derating) ITE (Commercial) 4.00" L x 2.00" W x 1.20" H (101.6mm x 50.8mm x 30.5mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Standby Output, Universal Input ABC40 - 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 179-2567 EAR99 8504.40.9510 32 40W 1 85% 5.1V - - - - No 4.242 kV 8 A
ABC40-1012G Bel Power Solutions ABC40-1012G -
RFQ
ECAD 7907 0.00000000 Bel Power Solutions ABC40 (40W) Box Not For New Designs -20°C ~ 70°C (With Derating) ITE (Commercial) 4.00" L x 2.00" W x 1.20" H (101.6mm x 50.8mm x 30.5mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Standby Output, Universal Input ABC40 - 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 32 42W 1 85% 12V - - - - No 4.242 kV 3.5 A
ABC40-1024G Bel Power Solutions ABC40-1024G -
RFQ
ECAD 6774 0.00000000 Bel Power Solutions ABC40 (40W) Box Not For New Designs -20°C ~ 70°C (With Derating) ITE (Commercial) 4.00" L x 2.00" W x 1.20" H (101.6mm x 50.8mm x 30.5mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Standby Output, Universal Input ABC40 - 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 32 40W 1 85% 24V - - - - No 4.242 kV 1.7 A
MBC40-1012G Bel Power Solutions MBC40-1012G -
RFQ
ECAD 5736 0.00000000 Bel Power Solutions MBC40 (40W) Box Not For New Designs -20°C ~ 70°C (With Derating) Medical 4.00" L x 2.00" W x 1.20" H (101.6mm x 50.8mm x 30.5mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Standby Output, Universal Input MBC40 - 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 32 40W 1 85% 12V - - - - No 4.242 kV 3.5 A
MBC40-1024G Bel Power Solutions MBC40-1024G -
RFQ
ECAD 5438 0.00000000 Bel Power Solutions MBC40 (40W) Box Not For New Designs -20°C ~ 70°C (With Derating) Medical 4.00" L x 2.00" W x 1.20" H (101.6mm x 50.8mm x 30.5mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Standby Output, Universal Input MBC40 - 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 32 40W 1 85% 24V - - - - No 4.242 kV 1.7 A
MBC40-1048G Bel Power Solutions MBC40-1048G -
RFQ
ECAD 7832 0.00000000 Bel Power Solutions MBC40 (40W) Box Not For New Designs -20°C ~ 70°C (With Derating) Medical 4.00" L x 2.00" W x 1.20" H (101.6mm x 50.8mm x 30.5mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Standby Output, Universal Input MBC40 - 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9510 32 40W 1 85% 48V - - - - No 4.242 kV 830 mA
MBC40-3002G Bel Power Solutions MBC40-3002G -
RFQ
ECAD 7805 0.00000000 Bel Power Solutions MBC40 (40W) Box Not For New Designs -20°C ~ 70°C (With Derating) Medical 4.00" L x 2.00" W x 1.20" H (101.6mm x 50.8mm x 30.5mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Standby Output, Universal Input MBC40 - 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9510 32 40W 3 85% 5.2V 14.6V -14.8V - - No 4.242 kV 6 A 1.5 A 500 mA
MBC60-3000G Bel Power Solutions MBC60-3000G -
RFQ
ECAD 2320 0.00000000 Bel Power Solutions MBC60 (60W) Box Not For New Designs -20°C ~ 70°C (With Derating) Medical 4.00" L x 2.00" W x 1.20" H (101.6mm x 50.8mm x 30.5mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Universal Input MBC60 CE, CSA 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 32 60W 3 85% 5.2V 12.5V -12.8V - - Yes 4.242 kV 8 A 3 A 500 mA
ABC60-1012G Bel Power Solutions ABC60-1012G -
RFQ
ECAD 9194 0.00000000 Bel Power Solutions ABC60 (60W) Box Not For New Designs -20°C ~ 70°C (With Derating) ITE (Commercial) 4.00" L x 2.00" W x 1.20" H (101.6mm x 50.8mm x 30.5mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Universal Input ABC60 CE 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 32 60W 1 85% 12V - - - - No 4.242 kV 5.4 A
ABC60-1015G Bel Power Solutions ABC60-1015G -
RFQ
ECAD 6358 0.00000000 Bel Power Solutions ABC60 (60W) Box Not For New Designs -20°C ~ 70°C (With Derating) ITE (Commercial) 4.00" L x 2.00" W x 1.20" H (101.6mm x 50.8mm x 30.5mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Universal Input ABC60 CE 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 179-2605 EAR99 8504.40.6018 32 60W 1 85% 15V - - - - No 4.242 kV 4.33 A
ABC60-1024G Bel Power Solutions ABC60-1024G 37.2600
RFQ
ECAD 431 0.00000000 Bel Power Solutions ABC60 (60W) Box Not For New Designs -20°C ~ 70°C (With Derating) ITE (Commercial) 4.00" L x 2.00" W x 1.20" H (101.6mm x 50.8mm x 30.5mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Universal Input ABC60 CE 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 179-2619 EAR99 8504.40.6018 32 60W 1 85% 24V - - - - No 4.242 kV 2.7 A
ABC60-1048G Bel Power Solutions ABC60-1048G -
RFQ
ECAD 6380 0.00000000 Bel Power Solutions ABC60 (60W) Box Not For New Designs -20°C ~ 70°C (With Derating) ITE (Commercial) 4.00" L x 2.00" W x 1.20" H (101.6mm x 50.8mm x 30.5mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Universal Input ABC60 CE 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 32 60W 1 85% 48V - - - - No 4.242 kV 1.35 A
ABC60-3001G Bel Power Solutions ABC60-3001G -
RFQ
ECAD 4351 0.00000000 Bel Power Solutions ABC60 (60W) Box Not For New Designs -20°C ~ 70°C (With Derating) ITE (Commercial) 4.00" L x 2.00" W x 1.20" H (101.6mm x 50.8mm x 30.5mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Universal Input ABC60 CE 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 32 60W 3 85% 5.2V 24V -12.8V - - Yes 4.242 kV 8 A 1.5 A 500 mA
ABC60-3002G Bel Power Solutions ABC60-3002G -
RFQ
ECAD 4337 0.00000000 Bel Power Solutions ABC60 (60W) Box Not For New Designs -20°C ~ 70°C (With Derating) ITE (Commercial) 4.00" L x 2.00" W x 1.20" H (101.6mm x 50.8mm x 30.5mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Universal Input ABC60 CE 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6007 32 60W 3 85% 5.2V 14.6V -16.2V - - Yes 4.242 kV 8 A 2.5 A 500 mA
MBC150-1005G-2 Bel Power Solutions MBC150-1005G-2 -
RFQ
ECAD 6544 0.00000000 Bel Power Solutions MBC150 (150W) Box Active -20°C ~ 70°C (With Derating) Medical 4.00" L x 2.00" W x 1.32" H (101.6mm x 50.8mm x 33.6mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, Standby Output, Universal Input MBC150 - 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9520 24 110W (150W Forced Air) 1 86% 5V - - - - No 5.9 kV 16 A
MBC150-1012G Bel Power Solutions MBC150-1012G 90.2700
RFQ
ECAD 64 0.00000000 Bel Power Solutions MBC150 (150W) Box Not For New Designs -20°C ~ 70°C (With Derating) Medical 4.00" L x 2.00" W x 1.32" H (101.6mm x 50.8mm x 33.6mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, Standby Output, Universal Input MBC150 - 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 24 110W (150W Forced Air) 1 86% 12V - - - - No 5.9 kV 8.33 A
MBC150-1048G Bel Power Solutions MBC150-1048G -
RFQ
ECAD 5071 0.00000000 Bel Power Solutions MBC150 (150W) Box Not For New Designs -20°C ~ 70°C (With Derating) Medical 4.00" L x 2.00" W x 1.32" H (101.6mm x 50.8mm x 33.6mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, Standby Output, Universal Input MBC150 - 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 24 110W (150W Forced Air) 1 86% 48V - - - - No 5.9 kV 2.08 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse