SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Package / Case Type Features Base Product Number Approval Agency Voltage - Input (Max) Supplier Device Package RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Isolation
REM5E-4815D/R10/A/X1 Recom Power REM5E-4815D/R10/A/X1 60.8200
RFQ
ECAD 4530 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-4815 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001369 EAR99 8504.40.9580 15 5 W 2 166mA, 166mA 36V 84% 15V -15V - - 10 kV
REM5E-4815D/R8/A Recom Power REM5E-4815D/R8/A 46.0800
RFQ
ECAD 6859 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM5E-4815 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001361 EAR99 8504.40.9580 15 5 W 2 166mA, 166mA 36V 84% 15V -15V - - 8 kV
REM5E-4815S/R10/A Recom Power REM5E-4815S/R10/A 50.2700
RFQ
ECAD 6485 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM5E-4815 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001127 EAR99 8504.40.9580 15 5 W 1 333mA 36V 84% 15V - - - 10 kV
REM5E-4815S/R8/A/CTRL Recom Power REM5E-4815S/R8/A/CTRL 46.0800
RFQ
ECAD 8419 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP REM5E-4815 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001122 EAR99 8504.40.9580 15 5 W 1 333mA 36V 84% 15V - - - 8 kV
REM5E-4815S/R8/A/X1 Recom Power REM5E-4815S/R8/A/X1 46.0800
RFQ
ECAD 8503 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-4815 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001123 EAR99 8504.40.9580 15 5 W 1 333mA 36V 84% 15V - - - 8 kV
REM5E-4824S/R8/A/CTRL Recom Power REM5E-4824S/R8/A/CTRL 46.0800
RFQ
ECAD 8187 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP REM5E-4824 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001170 EAR99 8504.40.9580 15 5 W 1 208mA 36V 85% 24V - - - 8 kV
REM6E-1209D/R10/A/CTRL Recom Power REM6E-1209D/R10/A/CTRL 62.5100
RFQ
ECAD 5141 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP REM6E-1209 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000936 EAR99 8504.40.9580 15 6 W 2 335mA, 335mA 9V 81% 9V -9V - - 10 kV
REM6E-1209S/R10/A Recom Power REM6E-1209S/R10/A 51.6400
RFQ
ECAD 1730 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM6E-1209 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000827 EAR99 8504.40.9580 15 6 W 1 667mA 9V 81% 9V - - - 10 kV
REM6E-1209S/R10/A/CTRL/X1 Recom Power REM6E-1209S/R10/A/CTRL/X1 62.5100
RFQ
ECAD 3761 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM6E-1209 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000830 EAR99 8504.40.9580 15 6 W 1 667mA 9V 81% 9V - - - 10 kV
REM6E-1212D/R10/A Recom Power REM6E-1212D/R10/A 56.8200
RFQ
ECAD 8669 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM6E-1212 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000971 EAR99 8504.40.9580 15 6 W 2 250mA, 250mA 9V 82% 12V -12V - - 10 kV
REM6E-1212D/R8/A/CTRL/X1 Recom Power REM6E-1212D/R8/A/CTRL/X1 57.2900
RFQ
ECAD 9536 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM6E-1212 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000968 EAR99 8504.40.9580 15 6 W 2 250mA, 250mA 9V 82% 12V -12V - - 8 kV
REM6E-1212D/R8/A/X1 Recom Power REM6E-1212D/R8/A/X1 52.0800
RFQ
ECAD 8334 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM6E-1212 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000967 EAR99 8504.40.9580 15 6 W 2 250mA, 250mA 9V 82% 12V -12V - - 8 kV
REM6E-1215D/R10/A Recom Power REM6E-1215D/R10/A 56.8200
RFQ
ECAD 5487 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM6E-1215 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001007 EAR99 8504.40.9580 15 6 W 2 200mA, 200mA 9V 83% 15V -15V - - 10 kV
REM6E-1215D/R10/A/X1 Recom Power REM6E-1215D/R10/A/X1 62.5100
RFQ
ECAD 5223 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM6E-1215 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001009 EAR99 8504.40.9580 15 6 W 2 200mA, 200mA 9V 83% 15V -15V - - 10 kV
REM6E-1215D/R8/A Recom Power REM6E-1215D/R8/A 47.3600
RFQ
ECAD 1177 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM6E-1215 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001001 EAR99 8504.40.9580 15 6 W 2 200mA, 200mA 9V 83% 15V -15V - - 8 kV
REM6E-1215D/R8/A/X1 Recom Power REM6E-1215D/R8/A/X1 52.0800
RFQ
ECAD 2563 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM6E-1215 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001003 EAR99 8504.40.9580 15 6 W 2 200mA, 200mA 9V 83% 15V -15V - - 8 kV
REM6E-1215S/R8/A/CTRL/X1 Recom Power REM6E-1215S/R8/A/CTRL/X1 52.0800
RFQ
ECAD 3742 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM6E-1215 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000860 EAR99 8504.40.9580 15 6 W 1 400mA 9V 83% 15V - - - 8 kV
REM6E-1224S/R8/A/X1 Recom Power REM6E-1224S/R8/A/X1 47.3600
RFQ
ECAD 6215 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM6E-1224 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000895 EAR99 8504.40.9580 15 6 W 1 250mA 9V 83% 24V - - - 8 kV
REM6E-2409D/R10/A/X1 Recom Power REM6E-2409D/R10/A/X1 62.5100
RFQ
ECAD 8921 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM6E-2409 CB, cURus 36V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000949 EAR99 8504.40.9580 15 6 W 2 335mA, 335mA 18V 82% 9V -9V - - 10 kV
REM6E-2409D/R8/A Recom Power REM6E-2409D/R8/A 47.3600
RFQ
ECAD 3625 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM6E-2409 CB, cURus 36V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000941 EAR99 8504.40.9580 15 6 W 2 335mA, 335mA 18V 82% 9V -9V - - 8 kV
REM6E-2409D/R8/A/CTRL/X1 Recom Power REM6E-2409D/R8/A/CTRL/X1 57.2900
RFQ
ECAD 6999 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM6E-2409 CB, cURus 36V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000944 EAR99 8504.40.9580 15 6 W 2 335mA, 335mA 18V 82% 9V -9V - - 8 kV
REM6E-2409S/R8/A Recom Power REM6E-2409S/R8/A 43.0400
RFQ
ECAD 6159 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM6E-2409 CB, cURus 36V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000833 EAR99 8504.40.9580 15 6 W 1 667mA 18V 82% 9V - - - 8 kV
REM6E-2412D/R10/A/CTRL/X1 Recom Power REM6E-2412D/R10/A/CTRL/X1 68.7500
RFQ
ECAD 3384 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM6E-2412 CB, cURus 36V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000986 EAR99 8504.40.9580 15 6 W 2 250mA, 250mA 18V 83% 12V -12V - - 10 kV
REM6E-2412S/R10/A/CTRL Recom Power REM6E-2412S/R10/A/CTRL 56.8200
RFQ
ECAD 2448 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP REM6E-2412 CB, cURus 36V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000762 EAR99 8504.40.9580 15 6 W 1 500mA 18V 83% 12V - - - 10 kV
REM6E-2415D/R10/A/X1 Recom Power REM6E-2415D/R10/A/X1 62.5100
RFQ
ECAD 6717 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM6E-2415 CB, cURus 36V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001021 EAR99 8504.40.9580 15 6 W 2 200mA, 200mA 18V 84% 15V -15V - - 10 kV
REM6E-2415S/R10/A/X1 Recom Power REM6E-2415S/R10/A/X1 56.8200
RFQ
ECAD 7481 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM6E-2415 CB, cURus 36V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000877 EAR99 8504.40.9580 15 6 W 1 400mA 18V 84% 15V - - - 10 kV
REM6E-2424S/R8/A/CTRL Recom Power REM6E-2424S/R8/A/CTRL 47.3600
RFQ
ECAD 4654 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP REM6E-2424 CB, cURus 36V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000906 EAR99 8504.40.9580 15 6 W 1 250mA 18V 84% 24V - - - 8 kV
REM6E-4809D/R10/A Recom Power REM6E-4809D/R10/A 59.6600
RFQ
ECAD 4282 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM6E-4809 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000959 EAR99 8504.40.9580 15 6 W 2 335mA, 335mA 36V 83% 9V -9V - - 10 kV
REM6E-4809D/R10/A/CTRL Recom Power REM6E-4809D/R10/A/CTRL 65.6400
RFQ
ECAD 9409 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP REM6E-4809 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000960 EAR99 8504.40.9580 15 6 W 2 335mA, 335mA 36V 83% 9V -9V - - 10 kV
REM6E-4809D/R8/A/CTRL Recom Power REM6E-4809D/R8/A/CTRL 54.6800
RFQ
ECAD 1155 0.00000000 Recom Power MEDLINE REM6E (6W) Tube Active -40°C ~ 75°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP REM6E-4809 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000954 EAR99 8504.40.9580 15 6 W 2 335mA, 335mA 36V 83% 9V -9V - - 8 kV
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse