SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Package / Case Type Features Base Product Number Voltage - Input (Max) DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Control Features Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Isolation
REM3-4824S/C Recom Power REM3-4824S/C 66.0200
RFQ
ECAD 6984 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-4824 75V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000059 EAR99 8504.40.9580 7 3 W 1 125mA 36V 86.5% 24V - - 5 kV
REM3-0505D/A/CTRL Recom Power REM3-0505D/A/CTRL 76.2600
RFQ
ECAD 3888 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-0505 9V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000061 EAR99 8504.40.9580 7 3 W 2 Enable, Active Low 300mA, 300mA 4.5V 83% 5V -5V - 5 kV
REM3-2405D/A/CTRL Recom Power REM3-2405D/A/CTRL 76.2600
RFQ
ECAD 5298 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-2405 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000067 EAR99 8504.40.9580 7 3 W 2 Enable, Active Low 300mA, 300mA 18V 83% 5V -5V - 5 kV
REM3-4805D/A/CTRL Recom Power REM3-4805D/A/CTRL 76.2600
RFQ
ECAD 1968 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-4805 75V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000070 EAR99 8504.40.9580 7 3 W 2 Enable, Active Low 300mA, 300mA 36V 83% 5V -5V - 5 kV
REM3-1212D/C Recom Power REM3-1212D/C 72.6100
RFQ
ECAD 5678 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-1212 18V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000077 EAR99 8504.40.9580 7 3 W 2 125mA, 125mA 9V 87.5% 12V -12V - 5 kV
REM3-2412D/A/CTRL Recom Power REM3-2412D/A/CTRL 76.2600
RFQ
ECAD 9577 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-2412 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000079 EAR99 8504.40.9580 7 3 W 2 Enable, Active Low 125mA, 125mA 18V 86% 12V -12V - 5 kV
REM3-4812D/A Recom Power REM3-4812D/A 72.6100
RFQ
ECAD 8610 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-4812 75V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000081 EAR99 8504.40.9580 7 3 W 2 125mA, 125mA 36V 86% 12V -12V - 5 kV
REM3-4812D/A/CTRL Recom Power REM3-4812D/A/CTRL 76.2600
RFQ
ECAD 8548 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-4812 75V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000082 EAR99 8504.40.9580 7 3 W 2 Enable, Active Low 125mA, 125mA 36V 86% 12V -12V - 5 kV
REM3-1215D/C Recom Power REM3-1215D/C 72.6100
RFQ
ECAD 5329 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-1215 18V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000089 EAR99 8504.40.9580 7 3 W 2 100mA, 100mA 9V 86.5% 15V -15V - 5 kV
REM3-2415D/C Recom Power REM3-2415D/C 72.6100
RFQ
ECAD 7720 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-2415 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000092 EAR99 8504.40.9580 7 3 W 2 100mA, 100mA 18V 86% 15V -15V - 5 kV
REM3-243.3SW/A/CTRL Recom Power REM3-243.3SW/A/CTRL 72.7800
RFQ
ECAD 5619 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-243.3 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000097 EAR99 8504.40.9580 7 3 W 1 Enable, Active Low 1A 9V 82% 3.3V - - 5 kV
REM3-243.3SW/C Recom Power REM3-243.3SW/C 69.3200
RFQ
ECAD 4863 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-243.3 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000098 EAR99 8504.40.9580 7 3 W 1 1A 9V 82% 3.3V - - 5 kV
REM3-483.3SW/C Recom Power REM3-483.3SW/C 69.3200
RFQ
ECAD 6330 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-483.3 75V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000101 EAR99 8504.40.9580 7 3 W 1 1A 18V 81% 3.3V - - 5 kV
REM3-2405SW/C Recom Power REM3-2405SW/C 69.3200
RFQ
ECAD 1114 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-2405 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000104 EAR99 8504.40.9580 7 3 W 1 600mA 9V 84.5% 5V - - 5 kV
REM3-4805SW/C Recom Power REM3-4805SW/C 69.3200
RFQ
ECAD 5936 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-4805 75V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000107 EAR99 8504.40.9580 7 3 W 1 600mA 18V 84% 5V - - 5 kV
REM3-2412SW/A/CTRL Recom Power REM3-2412SW/A/CTRL 72.7800
RFQ
ECAD 4134 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-2412 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000109 EAR99 8504.40.9580 7 3 W 1 Enable, Active Low 250mA 9V 87% 12V - - 5 kV
REM3-4812SW/A Recom Power REM3-4812SW/A 69.3200
RFQ
ECAD 9724 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-4812 75V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000111 EAR99 8504.40.9580 7 3 W 1 250mA 18V 87% 12V - - 5 kV
REM3-2424SW/A Recom Power REM3-2424SW/A 69.3200
RFQ
ECAD 3543 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-2424 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000120 EAR99 8504.40.9580 7 3 W 1 125mA 9V 87% 24V - - 5 kV
REM3-2424SW/A/CTRL Recom Power REM3-2424SW/A/CTRL 72.7800
RFQ
ECAD 2711 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-2424 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000121 EAR99 8504.40.9580 7 3 W 1 Enable, Active Low 125mA 9V 87% 24V - - 5 kV
REM3-2424SW/C Recom Power REM3-2424SW/C 69.3200
RFQ
ECAD 7221 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-2424 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000122 EAR99 8504.40.9580 7 3 W 1 125mA 9V 87% 24V - - 5 kV
REM3-4824SW/A/CTRL Recom Power REM3-4824SW/A/CTRL 69.3200
RFQ
ECAD 7825 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-4824 75V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000124 EAR99 8504.40.9580 7 3 W 1 Enable, Active Low 125mA 18V 86.5% 24V - - 5 kV
REM3-4824SW/C Recom Power REM3-4824SW/C 69.3200
RFQ
ECAD 8101 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-4824 75V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000125 EAR99 8504.40.9580 7 3 W 1 125mA 18V 86.5% 24V - - 5 kV
REM3-2405DW/A/CTRL Recom Power REM3-2405DW/A/CTRL 80.0700
RFQ
ECAD 1310 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-2405 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000127 EAR99 8504.40.9580 7 3 W 2 Enable, Active Low 300mA, 300mA 9V 83% 5V -5V - 5 kV
REM3-2405DW/C Recom Power REM3-2405DW/C 76.2600
RFQ
ECAD 3436 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-2405 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000128 EAR99 8504.40.9580 7 3 W 2 300mA, 300mA 9V 83% 5V -5V - 5 kV
REM3-4805DW/A Recom Power REM3-4805DW/A 76.2600
RFQ
ECAD 4230 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-4805 75V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000129 EAR99 8504.40.9580 7 3 W 2 300mA, 300mA 18V 83% 5V -5V - 5 kV
REM3-4805DW/C Recom Power REM3-4805DW/C 76.2600
RFQ
ECAD 9021 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-4805 75V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000131 EAR99 8504.40.9580 7 3 W 2 300mA, 300mA 18V 83% 5V -5V - 5 kV
REM3-2415DW/A/CTRL Recom Power REM3-2415DW/A/CTRL 80.0700
RFQ
ECAD 2304 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-2415 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000139 EAR99 8504.40.9580 7 3 W 2 Enable, Active Low 100mA, 100mA 9V 86% 15V -15V - 5 kV
REM3-2415DW/C Recom Power REM3-2415DW/C 76.2600
RFQ
ECAD 8548 0.00000000 Recom Power MEDLINE REM3 (3W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM3-2415 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000140 EAR99 8504.40.9580 7 3 W 2 100mA, 100mA 9V 86% 15V -15V - 5 kV
REM6-053.3S/A/CTRL Recom Power REM6-053.3S/A/CTRL 77.3800
RFQ
ECAD 7725 0.00000000 Recom Power MEDLINE REM6 (6W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM6-053.3 9V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000145 EAR99 8504.40.9580 7 6 W 1 Enable, Active Low 1.8A 4.5V 81.5% 3.3V - - 5 kV
REM6-053.3S/C Recom Power REM6-053.3S/C 73.7000
RFQ
ECAD 4535 0.00000000 Recom Power MEDLINE REM6 (6W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM6-053.3 9V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000146 EAR99 8504.40.9580 7 6 W 1 1.8A 4.5V 81.5% 3.3V - - 5 kV
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse