SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Package / Case Type Features Base Product Number Approval Agency Voltage - Input (Max) Supplier Device Package RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Isolation
REM5E-2424S/R10/A/CTRL Recom Power REM5E-2424S/R10/A/CTRL 52.5300
RFQ
ECAD 4407 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP REM5E-2424 CB, cURus 36V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001164 EAR99 8504.40.9580 15 5 W 1 208mA 18V 84% 24V - - - 10 kV
REM5E-2424S/R8/A/X1 Recom Power REM5E-2424S/R8/A/X1 43.7800
RFQ
ECAD 3572 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-2424 CB, cURus 36V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001159 EAR99 8504.40.9580 15 5 W 1 208mA 18V 84% 24V - - - 8 kV
REM5E-4805D/R10/A Recom Power REM5E-4805D/R10/A 55.2900
RFQ
ECAD 2217 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM5E-4805 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001223 EAR99 8504.40.9580 15 5 W 2 500mA, 500mA 36V 82% 5V -5V - - 10 kV
REM5E-4805D/R8/A/CTRL Recom Power REM5E-4805D/R8/A/CTRL 50.7000
RFQ
ECAD 6244 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP REM5E-4805 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001218 EAR99 8504.40.9580 15 5 W 2 500mA, 500mA 36V 82% 5V -5V - - 8 kV
REM5E-4805S/R10/A/X1 Recom Power REM5E-4805S/R10/A/X1 55.2900
RFQ
ECAD 6306 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-4805 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000631 EAR99 8504.40.9580 15 5 W 1 1A 36V 82% 5V - - - 10 kV
REM5E-4805S/R8/A/CTRL Recom Power REM5E-4805S/R8/A/CTRL 46.5200
RFQ
ECAD 2459 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP REM5E-4805 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000624 EAR99 8504.40.9580 15 5 W 1 1A 36V 82% 5V - - - 8 kV
REM5E-4805S/R8/A/X1 Recom Power REM5E-4805S/R8/A/X1 46.0800
RFQ
ECAD 9633 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-4805 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000625 EAR99 8504.40.9580 15 5 W 1 1A 36V 82% 5V - - - 8 kV
REM5E-4809D/R10/A/CTRL/X1 Recom Power REM5E-4809D/R10/A/CTRL/X1 66.9300
RFQ
ECAD 2621 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM5E-4809 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001274 EAR99 8504.40.9580 15 5 W 2 277mA, 277mA 36V 83% 9V -9V - - 10 kV
REM5E-4809D/R8/A/X1 Recom Power REM5E-4809D/R8/A/X1 50.7000
RFQ
ECAD 2522 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-4809 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001267 EAR99 8504.40.9580 15 5 W 2 277mA, 277mA 36V 83% 9V -9V - - 8 kV
REM5E-4809S/R10/A Recom Power REM5E-4809S/R10/A 50.2700
RFQ
ECAD 6739 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM5E-4809 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001079 EAR99 8504.40.9580 15 5 W 1 556mA 36V 83% 9V - - - 10 kV
REM5E-4809S/R10/A/CTRL Recom Power REM5E-4809S/R10/A/CTRL 55.2900
RFQ
ECAD 6861 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP REM5E-4809 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001080 EAR99 8504.40.9580 15 5 W 1 556mA 36V 83% 9V - - - 10 kV
REM5E-4809S/R10/A/X1 Recom Power REM5E-4809S/R10/A/X1 55.2900
RFQ
ECAD 8299 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-4809 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001081 EAR99 8504.40.9580 15 5 W 1 556mA 36V 83% 9V - - - 10 kV
REM5E-4809S/R8/A/CTRL Recom Power REM5E-4809S/R8/A/CTRL 46.0800
RFQ
ECAD 4513 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP REM5E-4809 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001074 EAR99 8504.40.9580 15 5 W 1 556mA 36V 83% 9V - - - 8 kV
REM5E-4809S/R8/A/CTRL/X1 Recom Power REM5E-4809S/R8/A/CTRL/X1 50.7000
RFQ
ECAD 7620 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM5E-4809 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001076 EAR99 8504.40.9580 15 5 W 1 556mA 36V 83% 9V - - - 8 kV
REM5E-4809S/R8/A/X1 Recom Power REM5E-4809S/R8/A/X1 46.0800
RFQ
ECAD 8236 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-4809 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001075 EAR99 8504.40.9580 15 5 W 1 556mA 36V 83% 9V - - - 8 kV
REM5E-4812D/R10/A Recom Power REM5E-4812D/R10/A 55.2900
RFQ
ECAD 2314 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM5E-4812 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001319 EAR99 8504.40.9580 15 5 W 2 208mA, 208mA 36V 84% 12V -12V - - 10 kV
REM5E-4812D/R10/A/CTRL/X1 Recom Power REM5E-4812D/R10/A/CTRL/X1 66.9300
RFQ
ECAD 3946 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM5E-4812 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001322 EAR99 8504.40.9580 15 5 W 2 208mA, 208mA 36V 84% 12V -12V - - 10 kV
REM5E-4812D/R10/A/X1 Recom Power REM5E-4812D/R10/A/X1 60.8200
RFQ
ECAD 6640 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-4812 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001321 EAR99 8504.40.9580 15 5 W 2 208mA, 208mA 36V 84% 12V -12V - - 10 kV
REM5E-4812D/R8/A/X1 Recom Power REM5E-4812D/R8/A/X1 50.7000
RFQ
ECAD 4323 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-4812 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001315 EAR99 8504.40.9580 15 5 W 2 208mA, 208mA 36V 84% 12V -12V - - 8 kV
REM5E-4812S/R10/A Recom Power REM5E-4812S/R10/A 50.2700
RFQ
ECAD 7369 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM5E-4812 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000677 EAR99 8504.40.9580 15 5 W 1 417mA 36V 82% 12V - - - 10 kV
REM5E-4812S/R8/A Recom Power REM5E-4812S/R8/A 42.5500
RFQ
ECAD 8552 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM5E-4812 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000671 EAR99 8504.40.9580 15 5 W 1 417mA 36V 82% 12V - - - 8 kV
REM5E-4812S/R8/A/CTRL/X1 Recom Power REM5E-4812S/R8/A/CTRL/X1 50.7000
RFQ
ECAD 1491 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM5E-4812 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000674 EAR99 8504.40.9580 15 5 W 1 417mA 36V 82% 12V - - - 8 kV
REM5E-4815D/R10/A/X1 Recom Power REM5E-4815D/R10/A/X1 60.8200
RFQ
ECAD 4530 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-4815 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001369 EAR99 8504.40.9580 15 5 W 2 166mA, 166mA 36V 84% 15V -15V - - 10 kV
REM5E-4815D/R8/A Recom Power REM5E-4815D/R8/A 46.0800
RFQ
ECAD 6859 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM5E-4815 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001361 EAR99 8504.40.9580 15 5 W 2 166mA, 166mA 36V 84% 15V -15V - - 8 kV
REM5E-4815D/R8/A/CTRL/X1 Recom Power REM5E-4815D/R8/A/CTRL/X1 55.7600
RFQ
ECAD 6659 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM5E-4815 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001364 EAR99 8504.40.9580 15 5 W 2 166mA, 166mA 36V 84% 15V -15V - - 8 kV
REM5E-4815D/R8/A/X1 Recom Power REM5E-4815D/R8/A/X1 50.7000
RFQ
ECAD 8553 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-4815 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001363 EAR99 8504.40.9580 15 5 W 2 166mA, 166mA 36V 84% 15V -15V - - 8 kV
REM5E-4815S/R10/A Recom Power REM5E-4815S/R10/A 50.2700
RFQ
ECAD 6485 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM5E-4815 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001127 EAR99 8504.40.9580 15 5 W 1 333mA 36V 84% 15V - - - 10 kV
REM5E-4815S/R8/A/CTRL Recom Power REM5E-4815S/R8/A/CTRL 46.0800
RFQ
ECAD 8419 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP REM5E-4815 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001122 EAR99 8504.40.9580 15 5 W 1 333mA 36V 84% 15V - - - 8 kV
REM5E-4815S/R8/A/X1 Recom Power REM5E-4815S/R8/A/X1 46.0800
RFQ
ECAD 8503 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-4815 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001123 EAR99 8504.40.9580 15 5 W 1 333mA 36V 84% 15V - - - 8 kV
REM5E-4824S/R8/A/CTRL Recom Power REM5E-4824S/R8/A/CTRL 46.0800
RFQ
ECAD 8187 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP REM5E-4824 CB, cURus 75V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001170 EAR99 8504.40.9580 15 5 W 1 208mA 36V 85% 24V - - - 8 kV