Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Package / Case Type Features Base Product Number Voltage - Input (Max) DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status ECCN HTSUS Standard Package Power (Watts) Number of Outputs Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Isolation
VI-JW3-MX-F3 Vicor Corporation VI-JW3-MX-F3 -
RFQ
ECAD 1198 0.00000000 Vicor Corporation VI-J00™ (75W) Bulk Active -55°C ~ 100°C ITE (Commercial) 2.28" L x 1.80" W x 0.79" H (57.9mm x 45.7mm x 20.0mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JW3 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 3.13A 18V 90% 24V - - 3 kV
VI-JW3-MX-F4 Vicor Corporation VI-JW3-MX-F4 -
RFQ
ECAD 6440 0.00000000 Vicor Corporation VI-J00™ (75W) Bulk Active -55°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JW3 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 3.13A 18V 90% 24V - - 3 kV
VI-JW3-MY Vicor Corporation VI-JW3-MY 825.1600
RFQ
ECAD 3567 0.00000000 Vicor Corporation VI-J00™ (50W) Bulk Active -55°C ~ 100°C ITE (Commercial) 2.28" L x 2.40" W x 0.50" H (57.9mm x 70.0mm x 12.7mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JW3 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 2.08A 18V 90% 24V - - 3 kV
VI-JW3-MZ Vicor Corporation VI-JW3-MZ 760.5800
RFQ
ECAD 8493 0.00000000 Vicor Corporation VI-J00™ (25W) Bulk Active -55°C ~ 100°C ITE (Commercial) 2.28" L x 2.40" W x 0.50" H (57.9mm x 70.0mm x 12.7mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JW3 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 25 W 1 1.04A 18V 90% 24V - - 3 kV
VI-JW3-MZ-F2 Vicor Corporation VI-JW3-MZ-F2 -
RFQ
ECAD 8215 0.00000000 Vicor Corporation VI-J00™ (25W) Bulk Active -55°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JW3 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 25 W 1 1.04A 18V 90% 24V - - 3 kV
VI-JW3-MZ-F3 Vicor Corporation VI-JW3-MZ-F3 -
RFQ
ECAD 5774 0.00000000 Vicor Corporation VI-J00™ (25W) Bulk Active -55°C ~ 100°C ITE (Commercial) 2.28" L x 1.80" W x 0.79" H (57.9mm x 45.7mm x 20.0mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JW3 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 25 W 1 1.04A 18V 90% 24V - - 3 kV
VI-JWJ-CY-B1 Vicor Corporation VI-JWJ-CY-B1 -
RFQ
ECAD 7468 0.00000000 Vicor Corporation VI-J00™ (50W) Bulk Active -25°C ~ 100°C ITE (Commercial) 2.36" L x 2.28" W x 1.08" H (59.9mm x 57.9mm x 27.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWJ 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 1.39A 18V 90% 36V - - 3 kV
VI-JWJ-CY-F3 Vicor Corporation VI-JWJ-CY-F3 -
RFQ
ECAD 6283 0.00000000 Vicor Corporation VI-J00™ (50W) Bulk Active -25°C ~ 100°C ITE (Commercial) 2.28" L x 1.80" W x 0.79" H (57.9mm x 45.7mm x 20.0mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWJ 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 1.39A 18V 90% 36V - - 3 kV
VI-JWJ-IZ Vicor Corporation VI-JWJ-IZ -
RFQ
ECAD 7189 0.00000000 Vicor Corporation VI-J00™ (25W) Bulk Obsolete -40°C ~ 100°C ITE (Commercial) 2.28" L x 2.40" W x 0.50" H (57.9mm x 70.0mm x 12.7mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWJ 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 25 W 1 694mA 18V 90% 36V - - 3 kV
VI-JWJ-IZ-F1 Vicor Corporation VI-JWJ-IZ-F1 -
RFQ
ECAD 2660 0.00000000 Vicor Corporation VI-J00™ (25W) Bulk Active -40°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 0.79" H (57.9mm x 47.2mm x 20.1mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWJ 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 25 W 1 694mA 18V 90% 36V - - 3 kV
VI-JWJ-IZ-F4 Vicor Corporation VI-JWJ-IZ-F4 -
RFQ
ECAD 9646 0.00000000 Vicor Corporation VI-J00™ (25W) Bulk Active -40°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWJ 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 25 W 1 694mA 18V 90% 36V - - 3 kV
VI-JWJ-IZ-S Vicor Corporation VI-JWJ-IZ-S -
RFQ
ECAD 2113 0.00000000 Vicor Corporation VI-J00™ (25W) Bulk Obsolete -40°C ~ 100°C ITE (Commercial) 2.28" L x 1.80" W x 0.52" H (57.9mm x 45.7mm x 13.2mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWJ 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 25 W 1 694mA 18V 90% 36V - - 3 kV
VI-JWJ-MY-F3 Vicor Corporation VI-JWJ-MY-F3 -
RFQ
ECAD 7122 0.00000000 Vicor Corporation VI-J00™ (50W) Bulk Active -55°C ~ 100°C ITE (Commercial) 2.28" L x 1.80" W x 0.79" H (57.9mm x 45.7mm x 20.0mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWJ 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 1.39A 18V 90% 36V - - 3 kV
VI-JWJ-MY-F4 Vicor Corporation VI-JWJ-MY-F4 -
RFQ
ECAD 9178 0.00000000 Vicor Corporation VI-J00™ (50W) Bulk Active -55°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWJ 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 1.39A 18V 90% 36V - - 3 kV
VI-JWL-CX-B1 Vicor Corporation VI-JWL-CX-B1 -
RFQ
ECAD 8340 0.00000000 Vicor Corporation VI-J00™ (75W) Bulk Active -25°C ~ 100°C ITE (Commercial) 2.36" L x 2.28" W x 1.08" H (59.9mm x 57.9mm x 27.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWL 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 2.68A 18V 90% 28V - - 3 kV
VI-JWL-CY-F4 Vicor Corporation VI-JWL-CY-F4 -
RFQ
ECAD 5660 0.00000000 Vicor Corporation VI-J00™ (50W) Bulk Active -25°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWL 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 1.79A 18V 90% 28V - - 3 kV
VI-JWL-CZ-B1 Vicor Corporation VI-JWL-CZ-B1 -
RFQ
ECAD 5182 0.00000000 Vicor Corporation VI-J00™ (25W) Bulk Obsolete -25°C ~ 100°C ITE (Commercial) 2.36" L x 2.28" W x 1.08" H (59.9mm x 57.9mm x 27.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWL 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 25 W 1 893mA 18V 90% 28V - - 3 kV
VI-JWL-CZ-F2 Vicor Corporation VI-JWL-CZ-F2 464.0700
RFQ
ECAD 2749 0.00000000 Vicor Corporation VI-J00™ (25W) Bulk Active -25°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWL 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 25 W 1 893mA 18V 90% 28V - - 3 kV
VI-JWL-EX-F2 Vicor Corporation VI-JWL-EX-F2 -
RFQ
ECAD 5602 0.00000000 Vicor Corporation VI-J00™ (75W) Bulk Obsolete -10°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWL 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 2.68A 18V 88% 28V - - 3 kV
VI-JWL-EX-S Vicor Corporation VI-JWL-EX-S -
RFQ
ECAD 9770 0.00000000 Vicor Corporation VI-J00™ (75W) Bulk Obsolete -10°C ~ 100°C ITE (Commercial) 2.28" L x 1.80" W x 0.52" H (57.9mm x 45.7mm x 13.2mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWL 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 2.68A 18V 88% 28V - - 3 kV
VI-JWL-EZ-F3 Vicor Corporation VI-JWL-EZ-F3 -
RFQ
ECAD 8055 0.00000000 Vicor Corporation VI-J00™ (25W) Bulk Active -10°C ~ 100°C ITE (Commercial) 2.28" L x 1.80" W x 0.79" H (57.9mm x 45.7mm x 20.0mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWL 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 25 W 1 893mA 18V 88% 28V - - 3 kV
VI-JWL-IW-F1 Vicor Corporation VI-JWL-IW-F1 -
RFQ
ECAD 7238 0.00000000 Vicor Corporation VI-J00™ (100W) Bulk Active -40°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 0.79" H (57.9mm x 47.2mm x 20.1mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWL 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 100 W 1 3.57A 18V 90% 28V - - 3 kV
VI-JWL-IY-F1 Vicor Corporation VI-JWL-IY-F1 -
RFQ
ECAD 9165 0.00000000 Vicor Corporation VI-J00™ (50W) Bulk Obsolete -40°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 0.79" H (57.9mm x 47.2mm x 20.1mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWL 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 1.79A 18V 90% 28V - - 3 kV
VI-JWL-IZ-F2 Vicor Corporation VI-JWL-IZ-F2 -
RFQ
ECAD 9006 0.00000000 Vicor Corporation VI-J00™ (25W) Bulk Active -40°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWL 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 25 W 1 893mA 18V 90% 28V - - 3 kV
VI-JWL-IZ-S Vicor Corporation VI-JWL-IZ-S -
RFQ
ECAD 2150 0.00000000 Vicor Corporation VI-J00™ (25W) Bulk Obsolete -40°C ~ 100°C ITE (Commercial) 2.28" L x 1.80" W x 0.52" H (57.9mm x 45.7mm x 13.2mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWL 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 25 W 1 893mA 18V 90% 28V - - 3 kV
VI-JWL-MW-B1 Vicor Corporation VI-JWL-MW-B1 -
RFQ
ECAD 9903 0.00000000 Vicor Corporation VI-J00™ (100W) Bulk Active -55°C ~ 100°C ITE (Commercial) 2.36" L x 2.28" W x 1.08" H (59.9mm x 57.9mm x 27.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWL 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 100 W 1 3.57A 18V 90% 28V - - 3 kV
VI-JWL-MX-F4 Vicor Corporation VI-JWL-MX-F4 -
RFQ
ECAD 3194 0.00000000 Vicor Corporation VI-J00™ (75W) Bulk Active -55°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWL 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 2.68A 18V 90% 28V - - 3 kV
VI-JWL-MZ-B1 Vicor Corporation VI-JWL-MZ-B1 -
RFQ
ECAD 8418 0.00000000 Vicor Corporation VI-J00™ (25W) Bulk Active -55°C ~ 100°C ITE (Commercial) 2.36" L x 2.28" W x 1.08" H (59.9mm x 57.9mm x 27.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWL 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 25 W 1 893mA 18V 90% 28V - - 3 kV
VI-JWL-MZ-F1 Vicor Corporation VI-JWL-MZ-F1 -
RFQ
ECAD 6352 0.00000000 Vicor Corporation VI-J00™ (25W) Bulk Active -55°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 0.79" H (57.9mm x 47.2mm x 20.1mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWL 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 25 W 1 893mA 18V 90% 28V - - 3 kV
VI-JWL-MZ-F2 Vicor Corporation VI-JWL-MZ-F2 -
RFQ
ECAD 7943 0.00000000 Vicor Corporation VI-J00™ (25W) Bulk Active -55°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWL 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 25 W 1 893mA 18V 90% 28V - - 3 kV
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse